• Title/Summary/Keyword: aortic aneurysm

Search Result 337, Processing Time 0.022 seconds

Bentall's Operation -5 Case Report- (Teflon felt를 이용한 Bentall 술식 치험 5례)

  • 정철하
    • Journal of Chest Surgery
    • /
    • v.27 no.2
    • /
    • pp.153-156
    • /
    • 1994
  • Bentall`s operation for repair of annuloaortic ectasia has been associated with postoperative bleeding and with false aneurysm of the anastomotic site between the coronary orifice and composite graft.Among 5 cases, 2 cases have been operated direct anastomosis between coronary artery and vascular graft.Remained 3 cases have been operated with doughnutlike Teflon felt buttress.The technique of sandwiching the freed button of aortic wall bearing the coronary artery ostium between an outer Teflon felt doughnutlike buttress and the inner composite graft provides a leak-proof anastomosis.We experienced one case reoperation for bleeding at coronary anastomotic site above method.

  • PDF

The Influence of Unfavorable Aortoiliac Anatomy on Short-Term Outcomes after Endovascular Aortic Repair

  • Lee, Jae Hang;Choi, Jin-Ho;Kim, Eung-Joong
    • Journal of Chest Surgery
    • /
    • v.51 no.3
    • /
    • pp.180-186
    • /
    • 2018
  • Background: Endovascular aortic repair (EVAR) is widely performed to treat infrarenal abdominal aortic aneurysms (AAAs), and related techniques and devices continue to be developed. Although continuous attempts have been made to perform EVAR in patients with unfavorable aortic anatomy, the outcomes are still controversial. This study examined the short-term outcomes of EVAR for the treatment of infrarenal AAAs in patients with a 'hostile' neck and unfavorable iliac anatomy. Methods: Thirty-eight patients who underwent EVAR from January 2012 to December 2017 were enrolled in this study. A hostile neck was defined based on neck length, angulation, the presence of an associated thrombus, or a conical shape. Unfavorable iliac anatomy was considered to be present in patients with a short common iliac artery (<15 mm) or the presence of aneurysmal changes. Results: No perioperative mortality was recorded. No significant differences were found depending on the presence of a hostile neck, but aneurysmal sac shrinkage was significantly less common in the group with unfavorable iliac anatomy (p=0.04). A multivariate analysis performed to analyze the risk factors for aneurysmal progression revealed only unfavorable iliac anatomy to be a risk factor (p=0.02). Conclusion: Patients with unfavorable aortic anatomy showed relatively satisfactory short-term outcomes after EVAR. No difference in the surgical outcomes was observed in patients with a hostile neck. However, unfavorable iliac anatomy was found to inhibit the shrinkage of the aneurysmal sac.

Reoperation of Prosthetic Heart Valve; An Analysis of Operative Risks and Late Results (인공 심장판막의 재치환술 -수술 위험인자와 수술 결과의 분석-)

  • 김관민
    • Journal of Chest Surgery
    • /
    • v.28 no.1
    • /
    • pp.23-30
    • /
    • 1995
  • From January 1985 to December 1992, of 1257 patients who underwent a heart valve replacement 210 [16.8% underwent reoperation on prosthetic heart valves, and 6 of them had a second valve reoperation. The indications for reoperation were structural deterioration [176 cases, 81.5% , prosthetic valve endocarditis [25 cases, 11.6% , paravalvular leak [12 cases, 5.6% , valve thrombosis [2 cases, 0.9% and ascending aortic aneurysm [1 case, 0.4% . Prosthetic valve failure developed most frequently in mitral position [57.9% and prosthetic valve endocarditis and paravalvular leak developed significantly in the aortic valve [40%, 75% [P<0.02 . Mean intervals between the primary valve operation and reoperation were 105.3$\pm$28.4 months in the case of prosthetic valve failure, 61.5$\pm$38.5 months in prosthetic valve endocarditis, 26.8$\pm$31.2 months in paravalvualr leak, and 25.0$\pm$7.0 months in valve thrombosis. In bioprostheses, the intervals were in 102.0$\pm$23.9 months in the aortic valve, and 103.6$\pm$30.8 months in the mitral valve. The overall hospital mortality rate was 7.9% [17/26 : 15% in aortic valve reoperation [6/40 , 6.5% in reoperation on the mitral prostheses [9/135 and 5.7% in multiple valve replacement [2.35 . Low cardiac output syndrome was the most common cause of death [70.6% . Advanced New York Heart Association class [P=0.00298 , explant period [P=0.0031 , aortic cross-clamp time [P=0.0070 , prosthetic valve endocarditis [P=0.0101 , paravalvularr leak [P=0.0096 , and second reoperation [P=0.00036 were the independent risk factors, but age, sex, valve position and multiple valve replacement did not have any influence on operative mortality. Mean follow up period was 38.6$\pm$24.5 months and total patient follow up period was 633.3 patient year. Actuarial survival at 8 year was 97.3$\pm$3.0% and 5 year event-free survival was 80.0$\pm$13.7%. The surgical risk of reoperation on heart valve prostheses in the advanced NYHA class patients is higher, so reoperation before severe hemodynamic impairment occurs is recommended.

  • PDF

Open Heart Surgery:Clinical Analysis of 180 Cases (개심술 180례에 대한 임상적 고찰)

  • 나명훈
    • Journal of Chest Surgery
    • /
    • v.27 no.6
    • /
    • pp.460-471
    • /
    • 1994
  • Between Feb. 1990 and Aug. 1993, 180 cases of the open heart surgery were performed under cardiopulmonary bypass in the Department of Thoracic & Cardiovascular surgery, Gil General Hospital. There were 83 cases with congenital heart diseases [CHD] and 97 cases with acquired heart diseases [AHD]. The CHD consisted of 78 acyanotic[mortality: 3.8 %] and 5 cyanotic cases with heart anomaly[mortality:l case]. The AHD were 97 cases, which contained 53 valvular, 27 ischemic heart diseases, 10 aortic diseases, 5 cases with myxoma, 1 case with post-infarct VSD, and 1 case with removal of infected pacing wire in right ventricle. In the 53 valvular heart diseases, there were 45 cases with valve replacement[MVR 27, AVR 9,MVR + AVR 9] and 8 cases with valvuloplasty. The number of the implanted prosthetic valves were 53. In MVR, 25 St. Jude, 6 Sorin, 3 Carpentier-Edward and 2 Intact medical valves were used. In aortic position, 13 St. Jude, 3 Sorin and 1 Intact medical valves were applied. The operative mortality was 5.6 % [3/53]. The annuloplasty applying artificial ring was performed in 17 patients[4 cases associated with MVR] and the number of the implanted ring was 19, which included 14 Duran ring[10 mitral, 4 tricuspid] and 5 Carpentier ring [3 mitral, 22 tricuspid]. In the 27 ischemic heart diseases, there were 9 cases with left main coronary artery lesions, 7 one vessel, 5 two vessels, and 6 three vessels. Average number of anastomosis was 2.8 per patient. The operative mortality was 14.3 % [4/27]. Among the 10 patients with aortic diseases, 7 cases were aortic dissection[type A: 5, type B: 2] and 3 cases were descending thoracic aortic aneurysm. The operative morality occurred in 3 cases. The overall mortality and the operative mortality of congenital and acquired heart disease was 7.8 %, 4.8% and 10.4%, respectively.

  • PDF

Nicardipine Hydrochloride Injectable Phase IV Clinical Trial-Study on the antihypertensive effect and safely of nicardipine for acute aortic dissection (급성대동맥해리에 대한 혈압강하요법으로서의 Nicardipine.HCI 주사액(Perdipine$^{circledR}$)의 유효성 및 안전성을 검토하기 위한 다기관 공동, 공개 제4상 임상시험)

  • Kim, Kyung-Hwan;Moon, In-Sung;Park, Jang-Sang;Koh, Yong-Bok;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.35 no.4
    • /
    • pp.267-273
    • /
    • 2002
  • Background: We performed a phase IV clinical trial to examine the usefulness of a continuous infusion of nicardipine hydrochloride to control hypertension in patients with acute aortic dissection. material and Method: Systolic/diastolic blood pressure, and heart rate were monitored before and after the intravenous administration of nicardipine in 31 patients with aortic diseases. The period of nicardipine administration in each patient was from 3 to 14 days. Efficacy was evaluated by determining the average amount of blood pressure reduction on the 3rd day of drug administration. The dosage of another antihypertensive agent was slowly tapered down, and ultimately replaced by the test drug. Result: 28 patients were diagnosed as acute aortic dissection, 2 patients as rupture of the aortic arch aneurysm, and 1 patient as traumatic aortic rupture. Mean age was 53.9 $\pm$ 14.9(29~89) years, and 21 patients(67.7%) were male. 14 patients(32.3%) had complications associated with underlying aortic disease: aortic insufficiency in 7, hemopericardium in 6, acute renal failure in 1, paraplegia in 1, lower extremity ischemia in 1, and hemothorax in 1. The time needed to reach the target blood pressure was within 15 minutes in 16, from 15 to 30 minutes in 10, from 30 to 45 minutes in 3 and from 45 to 60 minutes in 2, and their baseline average systolic, diastolic, and mean arterial blood pressures(mmHg) were 147$\pm$23, 82.3$\pm$ 18.6, and 104 $\pm$ 18, respectively. Average systolic, diastolic, and mean arterial blood pressures(mmHg) on the third day of nicardipine infusion were 119$\pm$ 12, 69$\pm$9, and 86$\pm$8, and they all showed statistically significant decrease(p<0.05). The average systolic, diastolic, and mean arterial blood pressure(mmHg) after the discontinuation of the nicardipine infusion were 119 $\pm$ 15, 71 $\pm$ 14, and 86$\pm$ 13, respectively. No significant difference was observed between the average pressures measured on the third day and those measured after the discontinuation of the nicardipine infusion, and no definite side effects were observed during the study period. Conclusion: Nicardipine hydrochloride was both effective and safe at controlling blood pressure in patients with acute aortic dissection.

Early and Midterm Results of Hybrid Endovascular Repair for Thoracic Aortic Disease (흉부대동맥 질환에서 시행된 하이브리드 혈관내 성형술의 중단기 성적)

  • Youn, Young-Nam;Kim, Kwan-Wook;Hong, Soon-Chang;Lee, Sak;Chang, Byung-Chul;Song, Seung-Jun
    • Journal of Chest Surgery
    • /
    • v.43 no.5
    • /
    • pp.490-498
    • /
    • 2010
  • Background: A hybrid procedure using an open surgical extra-anatomic bypass of aortic arch vessels and thoracic endovascular aortic repair (TEVAR) is less invasive than open surgery, and provides a suitable proximal landing zone. Here we report our experience with a hybrid TEVAR procedure at a single center. Material and Method: We retrospectively reviewed consecutive patients with thoracic aortic disease who received a hybrid TEVAR procedure between August 2008 and January 2010. Patients' data were prospectively collected and mean follow-up was $10.8{\pm}5.5$ months (range 3~20). Result: Nine patients (7 males and 2 females) with a mean age of $63.8{\pm}15.8$ years (range 38~84) underwent a hybrid procedure. Five patients had an arch or a proximal descending aortic aneurysm, two had a dissecting aneurysm of the descending aorta, and two had an aneurysm of the ascending arch and descending aorta. Mean expected mortality calculated by logistic EuroSCORE was 21%. Six patients underwent debranching and rerouting from ascending aorta to arch vessels, 2 had carotid-carotid bypass grafting, and 1 underwent carotid-axillary bypass grafting. Mean operation time was $221.4{\pm}84.0$ min (range 94~364). Deployment success of endovascular stent grafting was 100% with no endoleak on completion angiography. There was no mortality, and a small embolism in the branch of the right opthalmic artery in one patient. During follow-up, one intervention was required for the endoleak. Actuarial survival at 20 months was 100%. Conclusion: Early and mid-term results are encouraging and suggest that hybrid TEVAR procedures are less invasive and safer and represent an effective technique for treating thoracic aortic disease.

Aortic Arch Aneurysm Repair using a Prosthetic Graft with a Pre-mounted Distal Stent (Frozen Elephant Trunk) (원위부에 스텐트가 포함된 인조혈관 (Frozen Elephant Trunk)을 이용한 대동맥궁 동맥류 수술)

  • Chang, Hyoung-Woo;Chung, Eui-Suk;Choi, Jin-Ho;Lim, Cheong;Park, Kay-Hyun
    • Journal of Chest Surgery
    • /
    • v.42 no.3
    • /
    • pp.375-379
    • /
    • 2009
  • Difficulty in exposing anastomotic sites is a frequently encountered problem during surgical repair of a distal aortic arch aneurysm via median sternotomy or lateral thoracotomy. Endovascular repair has th limitation that it usually requires surgical rerouting of some of the brachiocephalic branches in order to get sufficient length for proximal fixation of the stent-graft. To take advantage of each approach, we fixed the distal end of the prosthetic graft by means of a pre-mounted metallic stent instead of performing conventional surgical anastomosis during the repair of distal arch aneurysms with using median sternotomy and hypothermic circulatory arrest. We report here on our experience with such 3 patients.

Recurrent Aortobronchial Fistula after Endovascular Stenting for Infected Pseudoaneurysm of the Proximal Descending Thoracic Aorta: Case Report

  • Lee, Sun-Geun;Lee, Seung Hyong;Park, Won Kyoun;Kim, Dae Hyun;Song, Jae Won;Cho, Sang-Ho
    • Journal of Chest Surgery
    • /
    • v.54 no.5
    • /
    • pp.425-428
    • /
    • 2021
  • Aortobronchial fistula (ABF) induced by an infected pseudoaneurysm of the thoracic aorta is a life-threatening condition. As surgical treatment is associated with significant mortality and morbidity, thoracic endovascular aneurysm repair (TEVAR) may be an alternative for the treatment of ABF. However, the long-term durability of this intervention is largely unknown and the recurrence of ABF is a potential complication. We experienced a case of recurrent ABF after stent grafting as an early procedure for an infected pseudoaneurysm of the thoracic aorta. Remnant ABF, bronchial and/or aortic wall erosion, vasa vasorum connected with ABF, and recurrent local inflammation of the thin aortic wall around ABF might cause recurrent hemoptysis. As a result, we suggest that TEVAR should be considered as a bridge therapy for the initial treatment of ABF resulting from an infected pseudoaneurysm, and that several options, such as second-stage surgery, should be considered to prevent the recurrence of ABF.

Trends in Regional Disparities in Cardiovascular Surgery and Mortality in Korea: A National Cross-sectional Study

  • Dal-Lae Jin;Kyoung-Hoon Kim;Euy Suk Chung;Seok-Jun Yoon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.57 no.3
    • /
    • pp.260-268
    • /
    • 2024
  • Objectives: Regional disparities in cardiovascular care in Korea have led to uneven patient outcomes. Despite the growing need for and access to procedures, few studies have linked regional service availability to mortality rates. This study analyzed regional variation in the utilization of major cardiovascular procedures and their associations with short-term mortality to provide better evidence regarding the relationship between healthcare resource distribution and patient survival. Methods: A cross-sectional study was conducted using nationwide claims data for patients who underwent coronary artery bypass grafting (CABG), percutaneous coronary intervention (PCI), stent insertion, or aortic aneurysm resection in 2022. Regional variation was assessed by the relevance index (RI). The associations between the regional RI and 30-day mortality were analyzed. Results: The RI was lowest for aortic aneurysm resection (mean, 26.2; standard deviation, 26.1), indicating the most uneven regional distribution among the surgical procedures. Patients undergoing this procedure in regions with higher RIs showed significantly lower 30-day mortality (adjusted odds ratio [aOR], 0.73; 95% confidence interval, 0.55 to 0.96; p=0.026) versus those with lower RIs. This suggests that cardiovascular surgery regional availability, as measured by RI, has an impact on mortality rates for certain complex surgical procedures. The RI was not associated with significant mortality differences for more widely available procedures like CABG (aOR, 0.96), PCI (aOR, 1.00), or stent insertion (aOR, 0.91). Conclusions: Significant regional variation and underutilization of cardiovascular surgery were found, with reduced access linked to worse mortality for complex procedures. Disparities should be addressed through collaboration among hospitals and policy efforts to improve outcomes.