• 제목/요약/키워드: antigen test kit

검색결과 60건 처리시간 0.028초

면역크로마토그라피 기법을 이용한 Salmonella 속균 신속 검출킷트 개발 (Development of the rapid detection kit for Salmonella spp. using immunochromatographic assay)

  • 정병열;정석찬
    • 대한수의학회지
    • /
    • 제45권2호
    • /
    • pp.191-197
    • /
    • 2005
  • An immunochromatographic (IC) strip for the rapid detection of Salmonella spp. in the enriched sample was developed. Affinity purified Salmonella polyclonal antibody was conjugated with 40 nm colloidal gold particles which were prepared by citrate method in our laboratory. The antigen-antibody-gold complex was captured by Salmonella antibody attached to test line of nitrocellulose membrane during the capillary migration of sample. Specificity of the IC strip was calculated to be 100% (12/12) and sensitivity was 97.6% (41/42) in the test with pure cultured bacteria. Salmonella was artificially inoculated into raw pork macerated with enrichment broth. And then it was 10-fold diluted from $5.2{\times}10^{8}CFU/ml$ to 5.2 CFU/ml. The IC strip could detect $5.2{\times}10^{6}CFU/ml$ before enrichment. However, the lowest limit of detection was 5.2 CFU/ml after overnight incubation. The results indicated that the IC assay was a rapid, economical and simple method with high specificity and sensitivity for the detection of Salmonella spp. without using any equipment.

면역글로불린제제 효능평가를 위한 5종 B형간염 표면항원항체검출법의 비교 (Comparison of 5 Assays for Quantification of Antibody to Hepatitis B Virus Surface Antigen with Immunoglobulin G Preparations)

  • 신인수;이유경;김오정;반상자
    • KSBB Journal
    • /
    • 제26권2호
    • /
    • pp.157-164
    • /
    • 2011
  • Five assays for anti-HBs were compared to improve potency test of Human lgG preparations. The three commercial EIA kits were optimized including dose response curve ranges and compared by conducting a co-laboratory study. After selecting the most reproducible EIA kit, methods comparison was performed with 22 samples in 5 different days. As a result, EIA (7.7 ${\pm}$ 5.3%) and MEIA (AxSYM: 3.7 ${\pm}$ 1.9%, IMx: 1.6 ${\pm}$ 0.8%) showed precision and accuracy (100.1 ${\pm}$ 12.6%). Therefore, the validated EIA assay was established and it is believed to be comparable to current MEIA.

자동화 매독검사 키트의 임상적 유용성 및 생물학적 위양성률의 평가 (Evaluation of Clinical Utility and Biologic False Positive (BFP) Rates in Automated Syphilis Test Kits for Syphilis Screening)

  • 김성만;이제훈
    • 대한임상검사과학회지
    • /
    • 제41권1호
    • /
    • pp.42-46
    • /
    • 2009
  • Unlike most bacteria, Treponema pallidum subspecies cannot be readily isolated or sustained in cell culture for numerous generations. In korea, two non treponemal tests are currently considered as standard; the VDRL slide test and RPR card test. These tests are based on an antigen composed of an alcoholic solution containing measured amount of cardiolipin, cholesterol, and sufficient purified lecithin to produce reactivity. The nontreponemal reagin tests measure immunoglobulin M (IgM) and IgG to lipoidal material released from damaged host cells as well as to lipoprotein-like material and possibly by cardiolipin released from the treponemes. The object of the evaluation was to evaluate the performance of the Mediace RPR kit on the automated biochemistry analyzer system as a method for screen method of syphilis as well as to identify BFP possibility. For evaluation of routine screening test, a total 2,380 specimens tested by Mediace RPR from 28th Oct, 2007 to 22th Feb, 2008. For evaluation of BFP possiblility, we measured samples which have potential BFP reaction in Syphilis test such as ANA (anti-nuclear antibody) positive (135 samples), CRP (C-reactive protein) positive (100 samples), RF (Rheumatoid factor) positive (26 samples), and other potential BFP cases (17 samples) including total 278 samples. These samples were tested quantitative test Mediace RPR with Hitachi 7600 P module. For comparison with current manual test, VDRL slide test were performed. Of these 2380 specimens, 2350 were negative, 30 were positive, and one were positive with TPHA. Both methods agreed for 2356 (98.9%) samples. Of the 30 samples showed positive results over 1.0 R.U, 6 samples showed positive results with VDRL test. Of these 6 samples, 1 samples showed positive with TPHA test. The combination of the Automated Biochemistry analyzer and VDRL test for retest can be increase efficiency of syphilis screening test.

  • PDF

Respiratory Syncytial Virus 감염의 조기 진단 kit "바이오라인 알에스브이TM"의 평가 (Evaluation of a rapid diagnostic kit "BIOLINE RSVTM" for the detection of respiratory syncytial virus)

  • 김소희;성지연;양미애;은병욱;이진아;최은화;이환종
    • Pediatric Infection and Vaccine
    • /
    • 제14권1호
    • /
    • pp.91-96
    • /
    • 2007
  • 목 적 : RSV 감염증 진단을 위한 여러 가지 신속 진단법이 이용되고 있다. 본 연구는 하기도 감염 소아의 비인두흡인물에서 RSV를 검출하는데 있어서 lateral-flow immunoassay 법을 이용하여 국내에서 개발된 RSV 조기 진단 kit인 바이오라인 알에스브이$^{TM}$(Standard Diagnostics, Inc., 용인, 대한민국)의 성적을 세포배양과 면역 형광법 결과와 비교 평가하기 위하여 수행되었다. 방 법 : 2002년 7월부터 2007년 2월까지 서울대학교 어린이병원의 응급실을 방문하거나 입원한 하기도 감염소아로부터 채취한 비인두 흡인물 319개를 대상으로 하여 RSV를 검출하는데 있어서 바이러스 배양과 면역 형광법을 기준으로 하여 바이오라인 알에스브이$^{TM}$ 검사의 성적을 평가하였다. 바이오라인 알에스브이$^{TM}$ 검사는 각 검체의 바이러스 배양과 면역 형광법 결과를 모르는 검사자에 의해서 두번 이상씩 시행되었다. 결 과 : 면역 형광법과 바이러스 배양이 모두 양성인 검체 110개 중 107개(97.3%), 면역 형광법만 양성인 검체 33개 중 29개(87.9%), 바이러스 배양법만 양성인 검체 26개 중 20개(76.9%)가 바이오라인 알에스브이$^{TM}$로 검사한 결과 양성으로 나타났으며, 두 가지 기준 검사에서 모두 음성인 검체 150개 중 140개(93.3%)가 바이오라인 알에스브이$^{TM}$ 검사 결과 음성이었다. 면역 형광법 또는 바이러스 배양법에 대한 바이오라인 알에스브이$^{TM}$ 검사의 민감도는 92.3%(156/169, 95% confidence interval[CI], 87.1-97.5%), 특이도는 93.3%(140/150, 95% CI, 88.4-98.2%), 양성 예측도는 94.0%(156/166, 89.5-98.5%), 음성 예측도는 91.5%(140/143, 95% CI, 86.0-97.0%), 일치도는 95.9%(306/319, 92.1-99.7%)이었다. 결 론 : 국내에서 개발된 RSV 감염 조기 진단 kit인 바이오라인 알에스브이$^{TM}$는 높은 민감도와 특이도를 보였다. 간단한 검사 방법과 신속한 결과라는 장점이 있어 향후 유행 시기에 유용한 진단법으로 사용될 수 있을 것으로 보인다.

  • PDF

결핵 진단에서 ICT Tuberculosis Test Kit의 효용성 (Evaluating the Usefulness of the ICT Tuberculosis Test Kit for the Diagnosis of Tuberculosis)

  • 장철훈;손한철;류기찬;박순규;이선호;김성률;박기형;김우석;구경수
    • Tuberculosis and Respiratory Diseases
    • /
    • 제46권4호
    • /
    • pp.473-480
    • /
    • 1999
  • 배 경: 우리 나라는 결핵의 유병률이 높기 때문에 간편하고 민감도가 높은 결핵 진단 방법이 필요하나, 결핵균의 특정한 균체 항원에 대한 항체 생성의 정도가 지역마다 다르고, 국가별로 BCG 예방 접종에 대한 정책이나 결핵의 유병률이 다르므로 우리 나라의 경우에도 외국에서 개발된 혈청 항체 검사 kit를 결핵 환자의 진단에 이용할 수 있을지 알 수 없다. 그래서 38-kDa 단백을 포함한 5가지 항원을 nitrocellulose 막에 고착시킨 항체 검사 kit인 ICT가 최근 소개되었기에 이를 이용한 항체 검사가 결핵의 진단에 유용하게 이용될 수 있는지를 알아보고자 하였다. 방 법: 결핵 환자군으로 진단 당시 과거력상 결핵 병력이 없는 초발 결핵 환자 37명, 과거의 결핵 병력이 있고 초치료에 실패했거나 완치 후 재발한 환자 31명과, 건강 대조군으로 건강 성인 25명, 병원의 결핵균 노출 지역 근무자 35명, 비결핵 호흡기 질환 환자 17명의 혈청으로 ICT 검사를 실시하여 결핵 진단의 민감도와 특이도를 확인하였다. 결 과: 결핵 초발 환자 (37명), 재발 환자 (31명)는 각각 73, 87%의 민감도를 보였다. 진단 당시의 항산균 염색 음성인 환자 (15명) 중 73%, 염색 양성인 환자 (53명) 중 81%에서 ICT 항체 양성을 보였다. 결핵성 뇌막염, 결핵성 림프절염 등 폐외결핵 환자 2명은 모두 ICT 항체검사에서 양성이었다. 건강 성인 (25명), 결핵균 노출 지역 근무자 (35명), 비결핵 호흡기질환 환자 (17명)는 각각 88%, 94%, 94%의 특이도를 보여 전체적으로 특이도 92%였다. 결 론: ICT 항체 검사는 38-kDa 항원을 포함한 5가지 항원을 막에 부착시켜 항체를 검사함으로써 결핵을 진단하는 kit로, 별도의 장비가 필요없이 간편하고 쉽게 수행할 수 있으며, 결핵의 진단에 73%의 민감도, 92%의 특이도를 보여서 전통적으로 결핵을 진단하는데 사용하던 X-선, 항산균 염색, 배양과 함께 보조적인 도구로 사용하면 폐결핵의 진단에 도움을 줄 수 있을 것으로 생각된다.

  • PDF

진행된 두경부암 환자에서 혈청 SCC 항원, CA 19-9, CA 125, DNA Microsatellite 변이와 재발 여부와의 관계 (Relationship between SCC Antigen, CA 19-9, CA 125 and DNA Microsatellite Alterations and Recurrence in Advanced Head and Neck Cancer Patients)

  • 최종욱;최정철;주형로
    • 대한두경부종양학회지
    • /
    • 제17권2호
    • /
    • pp.148-154
    • /
    • 2001
  • Objectives: This study was designed to investigate the significance of serum SCC antigen, CA 19-9, CA 125 level and DNA microsatellite alterations (MSA) as prognostic factors and indicators for recurrences in the pre-treatment and post-treatment state, respectively in head and neck cancer patients. Materials and Methods: 120 patients who received curative treatment for head and neck cancer from 1995 to 2000 were followed up successfully, and were analyzed retrospectively. Thirty healthy subjects served as normal controls. Serum SCC Ag levels were measured by microparticle enzyme immunoassay technique via IMX SCC assay, CA 19-9 levels were measured by CA 19-9 RIA test kit, and CA 125 levels were measured by CA 125 IRMA kit. MSA were identified after PCR amplification. Heterozygosity was considered lost if the ratio of one allele was significantly decreased (>50%) in serum DNA compared with normal DNA from lymphocytes. Results: Preoperative tumor markers were higher in cancer patients than control, but not significant. Postoperative SCC Ag levels were lower than preoperative levels. The SCC Ag levels were remained low in no evidence of disease (NED) group, but increased in locoregional recurrence and distant metastasis group. CA 19-9 and CA 125 levels showed no correlation between levels and recurrences and were not decreased significantly after primary tumor removal. MSA were detected in five out of 21 cases, and highly detected in distant metastasis group. Conclusion: SCC Ag seems to be a helpful serum tumor marker for early detection of recurrence and distant metastasis of head and neck cancer after curative treatment. But, CA 19-9 and CA 125 were not reliable markers for head and neck tumors. MSA were not statistically significant because of the small number of study group. However they may be helpful for screening serum molecular markers for early detection of distant metastasis of head and neck cancers.

  • PDF

RT-PCR과 ELISA를 이용한 PRRS 진단 및 항체가 조사 (Diagnosis of porcine reproductive and respiratory syndrome (PRRS) and its serological survey using the reverse transcription and polymerase chain reaction (RT-PCR) and ELISA)

  • 추금숙;한규삼;한재철;송희종
    • 한국동물위생학회지
    • /
    • 제27권3호
    • /
    • pp.273-280
    • /
    • 2004
  • The studies were performed for the PRRS antigen and antibody detection from breeding farms, artificial insemination(AI) center and growing farms in Jeonbuk province. 1. Specific PRRS primers were successfully amplified ORF6 617bp and ORF7 448 bp on agarose gel. 2. RT-PCR method has been establish by commercial kit and the thermal cycler program consisted of 30 cycles: $95^{\circ}C$ for 30 sec, $45^{\circ}C$ for 30 sec, and $72^{\circ}C$ for 45 sec. 3. The results of PRRS antibody test by ELISA method in AI centers were $6.6\%,\;53.3\%$ and breeding farms $65\%,\;65\%\;and\;38.7\%$, respectively. The serological positive of the antibody in gilt higher than sow. 4. The sero-positive of the PRRS antibody showed average $21\%$ in domestic farms, $56.2\%$ in breeding farms, and $29.9\%$ in AI center.

Evaluation of the cost-effectiveness of ASF detection with or without the use of on-field tests in different scenarios, in Sardinia

  • Cappai, Stefano;Loi, Federica;Rolesu, Sandro;Coccollone, Annamaria;Laddomada, Alberto;Sgarangella, Francesco;Masala, Sergio;Bitti, Giuseppe;Floris, Vincenzo;Desini, Pietro
    • Journal of Veterinary Science
    • /
    • 제21권2호
    • /
    • pp.14.1-14.10
    • /
    • 2020
  • African swine fever (ASF) is a highly contagious disease of domestic pigs and wild boars (WBs). Without a vaccine, early antibody and antigen detection and rapid diagnosis are crucial for the effective prevention of the disease and the employment of control measures. In Sardinia, where 3 different suid populations coexisted closely for a long time, the disease persists since 1978. The recent ASF eradication plan involves more stringent measures to combat free-ranging pigs and any kind of illegality in the pig industry. However, critical issues such as the low level of hunter cooperation with veterinary services and the time required for ASF detection in the WBs killed during the hunting season still remain. Considering the need to deliver true ASF negative carcasses as early as possible, this study focuses on the evaluation and validation of a duplex pen-side test that simultaneously detects antibodies and antigens specific to ASF virus, to improve molecular diagnosis under field conditions. The main goal was to establish the specificity of the two pen-side tests performed simultaneously and to determine their ability to detect the true ASF negative carcasses among the hunted WBs. Blood and organ samples of the WBs hunted during the 2018/2019 hunting seasons were obtained. A total of 160 animals were tested using the pen-side kit test; samples were collected for virological and serological analyses. A specificity of 98% was observed considering the official laboratory tests as gold standards. The new diagnostic techniques could facilitate faster and cost-effective control of the disease.

동결건조표준액의 안정성에 관한 보고 (Report on the Stability of Freeze-dried Standard Solution)

  • 박준모;유혜정;김한철;한걸순
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.139-148
    • /
    • 2012
  • 이 실험은 검사를 매일 실행하고, 동결건조된 표준액을 매번 녹여서 사용하는 검사실은 그 안정성에 대하여 고민을 할 필요는 없지만, 검사를 일주일에 한번 또는 두 번 정도 실행하는 검사실에 대한 보고라고 할 수도 있다. 동결 건조한 표준물질은 용해한 후 다시 동결을 할 경우 보통 $-20^{\circ}C$이하에서 유효기간까지 보관하라는 식으로만 표현 되어져 있고, 이는 몇 번을 녹인 후 재사용해도 안정한가에 대해서는 표현된 바가 없기에 이번 실험은 동결건조한 표준용액을 녹임과 동결을 여러 번 번복하였을 때와 냉장보관을 하였을 시에 표준용액의 변화도와 이것이 결과에 미치는 영향을 비교 평가하였다. 시판되고 있는 방사면역측정법을 이용한 체외진단키트 중 동결건조표준용액으로 되어진 부갑상선호르몬(PTH), 부신피지자극호르몬(ACTH), 황체형성호르몬(LH) kit를 같은Lot.NO.로 구성하였다. 이를 D.W.로 각 용량에 맞게 용해한 후 3개의 대조군으로 분리하였다. 제1대조군은 녹임, 동결을 번복하는 방법으로 하였고 제2대조군은 용해한 후 Test tube에 1회 사용할 만큼 분주하여 동결을 하였고 제3대조군은 냉장보관으로 하였다. 표준액과 환자농도값 날짜 별로 비교하였고, pH Test를 하였으며 날짜 별 단순회귀분석 및 결정계수 산출을 하였으며 Excel Paired t-Test (p-value)를 하여서 유의수준관계를 분석하였다. 위에서 실험한 ACTH, PTH, LH의 동결건조 표준액은 반드시 냉동보관을 할 것을 권고한다. 이는 다른 동결건조표준액도 같은 방법으로 보관을 해야 할 것이다.

  • PDF

Mycoplasma pneumoniae 감염의 신속 항원 검사 키트 "Ribotest Mycoplasma®"의 진단적 평가 (Evaluation of a Rapid Diagnostic Antigen Test Kit Ribotest Mycoplasma® for the Detection of Mycoplasma pneumoniae)

  • 양송이;한미선;김선중;이성연;최은화
    • Pediatric Infection and Vaccine
    • /
    • 제26권2호
    • /
    • pp.81-88
    • /
    • 2019
  • 목적: Mycoplasma pneumoniae 폐렴은 학동기 소아와 청소년의 지역사회 획득 폐렴 중 가장 흔한 원인으로, 조기에 원인 진단이 가능하다면 적절한 항균 요법을 결정하는데 도움이 된다. 본 연구는 하기도 감염 소아의 호흡기 검체에서 M. pneumoniae를 검출하기 위한 신속 항원 검사 방법의 진단적 가치를 평가하고자 하였다. 방법: 2010년 8월부터 2018년 8월까지 하기도 감염으로 서울대학교 어린이병원에서 응급실 또는 입원 치료를 받은 소아로부터 채취한 비인두 흡인물 중 M. pneumoniae 배양 검사를 시행한 후 $-70^{\circ}C$ 초저온냉동고에 보관되어 있는 검체 215개를 선정하였다. 비인두 흡인물 검체를 실온에서 해동하고 면역크로마토그래피를 이용한 Ribotest $Mycoplasma^{(R)}$를 시행한 후 두 명의 검사자가 결과를 판독하였다. 검사를 시행하는 자와 판독하는 자는 배양 검사 결과를 모르는 상태에서 검사를 진행하였다. 결과: 총 215개의 비인두 흡인물 검체 중 M. pneumoniae가 배양 양성인 검체는 119개, 배양 음성인 검체는 96개였다. M. pneumoniae가 배양 양성인 119개 중 74개(62.2%)가 Ribotest $Mycoplasma^{(R)}$ 검사 결과 양성이었고, 배양 음성인 96개 중 92개(95.8%)가 Ribotest $Mycoplasma^{(R)}$ 검사 결과 음성이었다. 배양 검사 결과를 기준으로 평가한 Ribotest $Mycoplasma^{(R)}$의 민감도는 62.2%(74/119, 95% 신뢰구간, 53.5-70.9%)이었으며, 특이도는 95.8% (92/96, 95% 신뢰구간, 91.8-99.8%)이었다. 또, 양성 예측도는 94.9% (74/78, 95% 신뢰구간, 90.0-99.8%)이었으며, 음성 예측도는 67.2% (92/137, 95% 신뢰구간, 59.3-75.0%), 그리고 일치도 77.21% (166/215, 95% 신뢰구간, 71.6-82.8%)를 보였다. 결론: 본 연구 결과, 신속 항원 검출법인 Ribotest $Mycoplasma^{(R)}$ 검사결과가 양성인 경우는 M. pneumoniae 배양 양성과의 일치도가 매우 높아서 M. pneumoniae 감염의 진단에 유용하였다. 그러나, Ribotest $Mycoplasma^{(R)}$ 검사결과가 음성인 경우의 약 1/3은 M. pneumoniae 배양 양성인 검체이었으므로, 음성 검사 결과에 대한 해석은 주의하여야 한다.