• 제목/요약/키워드: anti-islanding

검색결과 92건 처리시간 0.024초

계통연계형 태양광 인버터의 단독운전 방지를 위한 새로운 알고리즘 개발 (Development of Novel Algorithm for Anti-Islanding of Grid-Connected PV Inverter)

  • 최정식;고재섭;정동화
    • 조명전기설비학회논문지
    • /
    • 제25권10호
    • /
    • pp.76-86
    • /
    • 2011
  • This paper proposes novel algorithm for anti-islanding of grid-connected photovoltaic(PV) inverter. The islanding of PV systems can cause a variety of problems such as deterioration in power quality and electric shock. To prevent islanding, many anti-islanding methods are researched. Typical methods of anti-islanding are active frequency drift(AFD) and active frequency drift positive feedback(AFDPF). However, the AFD has problem that widely exists non diction zone(NDZ). The AFDPF is a method that improves the AFD method and is detected islanding by changing the chopping fraction(cf). However, The AFDPF does not detect when cf is very small and does not satisfy the IEEE Std. 929-2000 when cf is very big. Therefore, this paper proposes novel anti-islanding method that is simple to implement using virtual resister. The anti-islanding method proposed in this paper is compared with conventional method. The validity of this paper is proved using this result.

단독운전 방지를 위한 능동적 주파수 변환 기법의 검출 성능 및 THD 분석 (Detection Performance and THD Analysis of Active Frequency Drift for Anti-Islanding)

  • 조영민;최주엽;송승호;최익;이영권
    • 한국태양에너지학회 논문집
    • /
    • 제35권2호
    • /
    • pp.11-19
    • /
    • 2015
  • Islanding is a phenomenon that EPS(Electric Power System) is continuously energized by PV PCS(Photovoltaic Power Conditioning System) even when EPS is isolated from the grid. Unintentional islanding will result in safety hazard, power quality degradation and many other issues. So, islanding protection of grid-connected PV PCS is a key function for standards compliance. Nowadays, many anti-islanding schemes are researched. But existing anti-islanding schemes used in PV PCS have power quality degradation and non-detection zone issues. This paper analyses not only detection performance of existed anti-islanding schemes using active frequency drift but also THD of PCS output current according to each value disturbance for anti-islanding. In addition, the lowest value of disturbance in each scheme was tabulated under guarantee of anti-islanding condition.

A Novel Anti-Islanding Method for Utility Interconnection of Distributed Power Generation Systems

  • In-Ho
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제4B권4호
    • /
    • pp.217-224
    • /
    • 2004
  • A novel anti-islanding method for the distributed power generation system (DPGS) is proposed in this paper. Three different islanding scenarios are explored and presented based on the analysis of real and reactive power mismatch. It is shown via investigation that islanding voltage is a function of real power alone, where its frequency is a function of both real and reactive power. Following this analysis, a robust anti-islanding algorithm is developed. The proposed algorithm continuously perturbs ($\pm$5%) the reactive power supplied by the DPGS while simultaneously monitoring the utility voltage and frequency. In the event of islanding, a measurable frequency deviation takes place, upon which the real power of the DPGS is further reduced to 80%. A drop in voltage positively confirms islanding and the DPGS is then safely disconnected. This method of control is shown to be robust: it is able to detect islanding under resonant loads and is also fast acting (operable in one cycle). Possible islanding conditions are simulated and verified through analysis. Experimental results on a 0.5kW fuel cell system connected to a utility grid are discussed.

병렬연결된 다수 대 계통연계형 인버터를 위한 단독운전 방지 기법 (Anti-Islanding Scheme for a Number of Grid-connected Inverters under Parallel Operation)

  • 김동균;박관남;조상윤;이영권;유권종;송승호;최익;최주엽
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.351-352
    • /
    • 2016
  • Since anti-islanding scheme of grid-connected inverter is a key function of standards compliance, unintentional islanding results in safety hazards, reliability, and many other issues. Therefore, many anti-islanding schemes have been researched, however, existing anti-islanding schemes show poor power quality and non-detection zone issues. Besides, most of them have problems which deteriorate performance of islanding detection under parallel-operation. Therefore, this paper proposes a new anti-islanding scheme that has both negligible power quality degradation, no non-detection zone and precise islanding detection under parallel-operation. Finally, both simulation and experimental results validate the proposed scheme.

  • PDF

병렬 연결된 다수 대 계통연계형 인버터를 위한 단독운전 방지 기법 (The Anti-islanding Scheme for a Number of Grid-connected Inverters Under Parallel Operation)

  • 김동균;조상윤;이영권;최익;최주엽
    • 한국태양에너지학회 논문집
    • /
    • 제37권3호
    • /
    • pp.13-22
    • /
    • 2017
  • Anti-islanding scheme of grid-connected inverter is a key function of standards compliance, since unintentional islanding results in safety hazards, reliability, and many other issues. Therefore, many anti-islanding schemes have been researched, however, most of them have problems, which deteriorate performance of islanding detection under parallel-operation. Therefore, this paper proves the reason of problems and proposes a new anti-islanding scheme that has precise islanding detection under parallel-operation in single-phase and three-phase system. Finally, both simulation and experimental result validate the proposed scheme.

분산전원 시스템의 주파수 변동을 통한 단독운전 방지기법 분석 (Analysis of Anti-Islanding Schemes using Frequency Drift in Distributed Generation System)

  • 조영민;조상윤;송승호;최익;최주엽;이영권
    • 전력전자학회논문지
    • /
    • 제20권3호
    • /
    • pp.247-254
    • /
    • 2015
  • Unintentional islanding results in safety hazards, power quality degradation, and many other issues. Thus, islanding detection of grid-connected distributed generation system is a key function for standards compliance. Many anti-islanding schemes are currently being studied; however, existing anti-islanding schemes used in inverters have power quality degradation and non-detection zone issues. Therefore, this paper analyzes existing anti-islanding schemes by using frequency drift in accordance with both islanding detection performance and power quality. This paper also proposes a new anti-islanding scheme by using frequency drift. Both simulation and experimental results show that the proposed scheme has negligible power quality degradation and no non-detection zones compared with other existing schemes.

분산형 태양광발전시스템의 단독운전 검출기법 (Anti-islanding method for distributed PV generation systems)

  • 황인호;안교상
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.64-67
    • /
    • 2005
  • Many anti-islanding methods have been developed and tested in pratice. Generally, it seems to be possible to include effective and reliable anti-islanding methods in the PV inverter However, it is difficult to detect islanding phenomenon in the case of multiple systems in the same distribution line. In this paper, the islanding possibility of distributed PV generation system is analyzed and discussed to detect islanding phenomenon.

  • PDF

병렬운전하는 계통연계형 태양광 발전용 인버터의 단독운전 검출 성능 분석 (Performance Analysis of Anti-islanding Function for Grid-connected PV Inverter Systems under Parallel Connections)

  • 정영석;유병규;강기환
    • 한국태양에너지학회 논문집
    • /
    • 제33권5호
    • /
    • pp.34-40
    • /
    • 2013
  • Islanding phenomenon of photovoltaic system is undesirable because it leads to a safety hazard to utility service personnel and may cause damage to power generation and power supply facilities as a result of unsynchronized re-closure. Anti-islanding protection is an important technical requirement for grid-connected PV system. Until now, various anti-islanding methods for detecting and preventing islanding of photovoltaic and other distributed generations have been proposed. Most of them are focusing on the anti-islanding performance of single PV system according to the related international and domestic standard test procedures. There are few studies on the islanding phenomenon for multiple photovoltaic operation in parallel. This paper presents performance analysis of anti-islanding function for grid-connected PV inverter systems when several PV inverters are connected in parallel.

Multi-inverter 환경에 적합한 SMS기법을 이용한 Anti-islanding 방법 (An Improved SMS Anti-islanding Method for Utility Interconnection of Multiple Distributed Power Generations)

  • 김태원;박태준;이성희;한무호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 추계학술대회 논문집
    • /
    • pp.36-38
    • /
    • 2008
  • 본 논문에서는 여러 대의 인버터를 동시에 사용하는 분산전원 환경하에서 Anti-islanding을 효과적으로 할 수 있는 방안을 제안한다. 제안하는 Anti-islanding기법은 SMS(Sliding Mode Frequency Shift)를 근간으로 하면서 공진 Q가 높을 때 검출이 어려운 단점을 해결하는 방법을 제시한다. SMS위상의 변동 값을 판단근거를 사용하지 않고 SMS위상의 적분 값을 판단근거로 사용한다. Run on시간이 0.5초 이내로 국내외 규격을 모두 만족시킨다. 여러 대의 인버터를 병렬로 접속해도 islanding 검출이 탁월하다. 출력전력의 품질 면에 있어서도 다른 Anti-islanding기법에 비해 우수하다. 본 알고리즘의 우수성을 시뮬레이션과 실험을 통해 검증하였다.

  • PDF

Active Frequency Drift Method for Islanding Detection Applied to Micro-inverter with Uncontrollable Reactive Power

  • Kwak, Raeho;Lee, June-Hee;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1918-1927
    • /
    • 2016
  • This paper proposes active frequency drift (AFD) as an anti-islanding method applied to micro-inverters with uncontrollable reactive power. When using ordinary inverter topologies, such as full bridge inverters in photovoltaic systems, the islanding phenomenon can be detected with reactive power-based methods, such as reactive power variation. However, when the inverter topology cannot control the reactive power, conventional anti-islanding methods with reactive power cannot be utilized. In this work, the topology used in this paper cannot control the reactive power. Thus, an anti-islanding method that can be used in topologies that cannot control the reactive power is proposed. The conventional anti-islanding method of the topology that cannot control reactive power is introduced and analyzed. Unlike the conventional AFD method, the proposed method extends a zero current interval every predetermined cycle. The proposed method offers certain advantages over conventional AFD methods, such as total harmonic distortion. The proposed method is validated through simulation and experiment.