• 제목/요약/키워드: anti-corrosion

검색결과 337건 처리시간 0.023초

확산한계전류밀도 고찰에 의한 방청도료의 내식성평가 (Evaluation of Corrosion Resistance of Anti-Corrosive Paint by Investigation of Diffusion Limiting Current Density)

  • 문경만;김윤해;이명훈;이인원;박현;전호환
    • 한국해양공학회지
    • /
    • 제23권4호
    • /
    • pp.64-68
    • /
    • 2009
  • It has been observed that coated steel structures deteriorate more rapidly than the designed lifetime due to acid rain caused by air pollution, etc. Therefore, improving the corrosion resistance of anti-corrosive paint is very important in terms of safety and the economic point of view. In this study, the corrosion resistance of five kinds of anti-corrosive paints, including the Acryl, Fluorine, and Epoxy resin series, were investigated with electrochemical methods, such as corrosion potential measurements, polarization curves, diffusion limiting current density, etc. As a result, the corrosion resistance of the F101 specimen with the fluorine resin series was found to be superior to the other specimens, while E100 with the epoxy resin series also showed a somewhat good corrosion resistance. Furthermore, it was observed that the amount of water and oxygen entering the inner side of a painted film increased with an increase in immersion time, irrespective of the kind of resin series. However, the oxygen diffusion limiting current density of a specimen with good corrosion resistance was relatively decreased compared to other specimens, because of the difficulty of oxygen diffusion penetrating to the inner side of the film. Consequently it is suggested that we can qualitatively evaluate the corrosion resistance of an anti-corrosive paint by measuring the diffusion limiting current density as an electrochemical method.

철근부식억제형 구체방수재의 방청효과에 관한 연구 (A Study on Anti-Corrosion Effect of Powder Self Water Proof Admixture Mixed Corrosion Inhibitor for Reinforcing Steel)

  • 신도철;손형호;김원화
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.409-414
    • /
    • 2002
  • This study is intended to develop the self water proof admixture for durability concrete by anti-corrosion inhibitor. Chloride induced corrosion of reinforcement is one of the main factor which cause the deterioration of concrete structure. When the substitute anti-corrosion agents for a part of self waterproofing agent, the corrosion-proof increases for the increased water proofing capacity. And proper self waterproofing agent by cement weight in concrete was generally positive effect to concrete compressive strength, slump, freezing and thawing resistance. Also, permeability and absorption show a straight decrease when self waterproofing agent is added.

  • PDF

철근방식을 위한 방청제의 성능 평가에 관한 연구 (Evaluation and Application of Anti-Corrosion Inhibitor for the Corrosion Protection of Reinforcing Bars)

  • 김상철;강승희;이두재
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.248-253
    • /
    • 1997
  • The study was carried out to evaluate material characteristics and environmental effects of anti-corrosion inhibitor which is known to be very easy to use, since the admixture is added during concrete mixing. Specimens were fabricate with 6 different dosages of anti-corrosion inhibitor and cured in the autoclave chamber with different number of cycles. As a result of measuring corrosion of reinforcing bars embedded in concrete, it was found that even small amount of admixture application can prevent reinforcing bars from corrosion and the efficiency is gradually decreased with increase of the number of autoclave cycles and of percentage of chloride content. In addition, the admixture will not affect material characteristics such as compressive strength and air content.

  • PDF

Coating Performance of SiO2 / Epoxy Composites as a Corrosion Protector

  • Rzaij, Dina R.;Ahmed, Nagham Y.;Alhaboubi, Naseer
    • Corrosion Science and Technology
    • /
    • 제21권2호
    • /
    • pp.111-120
    • /
    • 2022
  • To solve the corrosion problem of industrial equipment and other constructions containing metals, corrosion protection can be performed by using coating which provides a barrier between the metal and its environment. Coatings play a significant role in protecting irons and steels in harsh marine and acid environments. This study was conducted to identify an anti-corrosive epoxy coating for carbon steel composite with 0.1, 0.3, and 0.5 wt% concentrations of nanoparticles of SiO2 using the dip-coating method. The electrochemical behavior was analyzed with open circuit potential (OCP) technics and polarization curves (Tafle) in 3.5 wt% NaCl and 5 vol% H2SO4 media. The structure, composition, and morphology were characterized using different analytical techniques such as X-ray Diffraction (XRD), Fourier Transform Infrared spectrum (FT-IR), and Scanning Electron Microscopy (SEM). Results revealed that epoxynano SiO2 coating demonstrated a lower corrosion rate of 2.51 × 10-4 mm/year and the efficiency of corrosion protection was as high as 99.77%. The electrochemical measurement showed that the nano-SiO2 / epoxy coating enhanced the anti-corrosive performance in both NaCl and H2SO4 media.

방청시멘트 도막철근의 내부식 성능 및 부착강도 성능연구 (Corrosion and Bond Strength Characteristics of Anti-Corrosive Cement Coated Reinforcements)

  • 오병환;이종렬;조윤구
    • 콘크리트학회지
    • /
    • 제11권2호
    • /
    • pp.251-259
    • /
    • 1999
  • 최근 다양한 침해환경에 건설되는 구조물이 증가함에 따라 철근 및 강재의 부식위험성이 높아지면서, 철근 콘크리트 구조물의 내구성 저하문제가 큰 관심으로 떠오르고 있다. 특히 해양 환경하에 건설된 철근 콘크리트 구조물의 경우 구조물 외부로부터 침투되는 염분의 영향으로 인한 철근부식이 발생 및 진행되어 콘크리트 구조물에 균열, 박리 등의 손상을 받게된다. 그러므로 해양콘크리트 구조물은 염해에 대해 내구성 및 신뢰성 확보가 중요시되고 있다. 따라서, 본 연구에서는 철근의 부착강도를 크게 감소시키지 않게 하는 방법으로서 시멘트 계통의 방청시멘트를 철근에 도막한 후 내부식성능과 부착강도특성을 실험적으로 연구하였다. 본 연구결과, 방청시멘트 도막철근은 소요의 내부식성능을 갖고 있으면서도 부착강도특성도 일반철근과 유사하였으며, 앞으로 실구조물의 내구성증진을 위해 효율적으로 사용될 수 있는 토대가 될 것으로 사료된다.

Improved Corrosion and Abrasion Resistance of Organic-Inorganic Composite Coated Electro-galvanized Steels for Digital TV Panels

  • Jo, Du-Hwan;Noh, Sang-Geol;Park, Jong-Tae;Kang, Choon-Ho
    • Corrosion Science and Technology
    • /
    • 제14권5호
    • /
    • pp.213-217
    • /
    • 2015
  • Recently, household electronic industries require environmentally-friendly and highly functional steels in order to enhance the quality of human life. Customers especially require both excellent corrosion and abrasion resistant anti-fingerprint steels for digital TV panels. Thus POSCO has developed new functional electro-galvanized steels, which have double coated layers with organic-inorganic composites on the zinc surface of the steel for usage as the bottom chassis panel of TVs. The inorganic solution for the bottom layer consists of inorganic phosphate, magnesium, and zirconium compounds with a small amount of epoxy binder, and affords both improved adhesion properties by chemical conversion reactions and corrosion resistance due to a self-healing effect. The composite solution for the top layer was prepared by fine dispersion of organic-inorganic ingredients that consist of a urethane modified polyacrylate polymer, hardener, silica sol and a titanium complex inhibitor in aqueous media. Both composite solutions were coated on the steel surface by using a roll coater and then cured through an induction furnace in the electro-galvanizing line. New anti-fingerprint steel was evaluated for quality performance through such procedures as the salt spray test for corrosion resistance, tribological test for abrasion resistance, and conductivity test for surface electric conductance regarding to both types of polymer resin and coating weight of composite solution. New composite coated anti-fingerprint steels afford both better corrosion resistance and abrasion properties compared to conventional anti-fingerprint steel that mainly consists of acrylate polymers. Detailed discussions of both composite solutions and experimental results suggest that urethane modifications of acrylate polymers of composite solutions play a key role in enhanced quality performances.

열처리를 통한 3가 크롬도금층의 마모 및 부식특성 개선 (Improvement of the Wear Resistance and Anti-Corrosion of the Trivalent Cr Platings Using Heat Treatments)

  • 남기석;박율민;나종주;권식철
    • 열처리공학회지
    • /
    • 제16권6호
    • /
    • pp.335-340
    • /
    • 2003
  • To improve properties of wear resistance and anti-corrosion of the trivalent chromium platings, oxinitrocarbunsing and steam oxidation were conducted. Armophous trivalent Cr platings could be transformed to chromium carbides of high hardness, that showed low friction and wear rate. Even though micro-cracks were within as platings, superior anti-corrosion property was obtained by these treatments due to healing of cracks at the interface between the trivalent chromium platings and substrate.

역수압 작용을 고려한 방수·방식재의 부착강도 시험방법에 관한 연구 (A Study on the Test Methods of Bond Strength in Waterproofing and Anti-corrosion Materials by Reversed Pressure)

  • 김명지;최수영;최성민;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.232-233
    • /
    • 2014
  • Recently, water treatment facility is usually eastablished in underground, and waterproofing and anti-corrosion materials for concrete structures applied water treatment tank is developing in various ways. However, as the limit of research focused on durability improvement of top coating material, it is insufficient to study on the adhesion strength between the concrete surface and primer. Therefore, there is to confirm the adhesion of between concrete surface and the three primers used as anti-corrosion waterproofing materials, and to investigate the properties of adhesion strength according to the condition such as wet codition and water pressure condition of the concrete surface in this study.

  • PDF

전기화학적 임피던스 분광법(EIS)을 이용한 고주파 아크 금속용사 피막의 강재 방식성능 평가에 관한 실험적 연구 (An Experimental Study on the Evaluation of Anti-corrosion Performance of High-frequency Arc Metal Spray film on Steel using EIS Method)

  • 최홍복;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 추계 학술논문 발표대회
    • /
    • pp.61-62
    • /
    • 2014
  • To evaluate anti-corrosion performance of high-frequency arc metal spray film in accordance with metal type and epoxy sealing coat application status, electrochemical impedance spectroscopy(EIS) method was conducted in this study. As a result, in case of applying Al-Mg alloy metal spray film, it showed the best polarization resistance. In case of applying epoxy sealing coat, it showed increased polarization resistance of arc metal spray film. Through this experiment, it is judged that Al-Mg alloy arc metal spray film with epoxy sealing coat can increase the biggest anti-corrosion performance of high-frequency arc metal spray film on steel.

  • PDF

440A 강의 균일부식에 미치는 합금원소와 열처리의 영향(I) (The Effect of Alloying Elements and Heat Treatment on the Uniform Corrosion of 440A Martensitic Stainless Steel(I))

  • 김영철;강창룡;정병호
    • 동력기계공학회지
    • /
    • 제15권2호
    • /
    • pp.42-48
    • /
    • 2011
  • 440A martensitic stainless steels which were modified with reduced carbon content(~0.5%) and addition of small amount of nickel, vanadium, tungsten and molybdenum were manufactured. Effects of alloying elements and tempering temperatures on the uniform corrosion in the solution of lN H2S04 were investigated through the electrochemical polarization test. When tempering temperature is constant, corrosion current density in active-passive transition point, Icorr, decreased a little with an increase of austenitizing temperature. In addition to this, when austenitizing temperature is constant, longer holding time showed a little lower Icorr and Ipass, passive current density. And when austenitized at $1050^{\circ}C$ and tempered in a range of $350{\sim}750^{\circ}C$, best anti-corrosion properties were obtained at $350^{\circ}C$ tempering temperature while worst at $450^{\circ}C$ or $550^{\circ}C$. The specimens tempered at below $450^{\circ}C$ and above $550^{\circ}C$, similar and good anti-corrosion characteristics were obtained regardless of alloying elements added, showing anti-corrosion characteristics are influenced more by tempering temperature than by alloying elements.