• Title/Summary/Keyword: antenna size

Search Result 898, Processing Time 0.027 seconds

Compact Orthomode Transducer for Field Experiments of Radar Backscatter at L-band (L-밴드 대역 레이더 후방 산란 측정용 소형 직교 모드 변환기)

  • Hwang, Ji-Hwan;Kwon, Soon-Gu;Joo, Jeong-Myeong;Oh, Yi-Sok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.7
    • /
    • pp.711-719
    • /
    • 2011
  • A study of miniaturization of an L-band orthomode transducer(OMT) for field experiments of radar backscatter is presented in this paper. The proposed OMT is not required the additional waveguide taper structures to connect with a standard adaptor by the newly designed junction structure which bases on a waveguide taper. Total length of the OMT for L-band is about 1.2 ${\lambda}_o$(310 mm) and it's a size of 60 % of the existing OMTs. And, to increase the matching and isolation performances of each polarization, two conducting posts are inserted. The bandwidth of 420 MHz and the isolation level of about 40 dB are measured in the operating frequency. The L-band scatterometer consisting of the manufactured OMT, a horn-antenna and network analyzer(Agilent 8753E) was used STCT and 2DTST to analysis the measurement accuracy of radar backscatter. The full-polarimetric RCSs of test-target, 55 cm trihedral corner reflector, measured by the calibrated scatterometer have errors of -0.2 dB and 0.25 dB for vv-/hh-polarization, respectively. The effective isolation level is about 35.8 dB in the operating frequency. Then, the horn-antenna used to measure has the length of 300 mm, the aperture size of $450{\times}450\;mm^2$, and HPBWs of $29.5^{\circ}$ and $36.5^{\circ}$ on the principle E-/H-planes.

Diurnal Roosts Selection and Home Range Size in the Myotis Aurascens (Chiroptera: Vespertilionidae) Inhabiting a Rural Area (교외지역에 서식하는 Myotis aurascens의 주간휴식지 선택 및 행동권 크기)

  • Chung, Chul Un;Kim, Sung Chul;Han, Sang Hun
    • Journal of Environmental Science International
    • /
    • v.22 no.9
    • /
    • pp.1227-1234
    • /
    • 2013
  • Between July and October 2011, radio-tracking was used to analyze the characteristics of home ranges and day roosts of Myotis aurascens by using 3 individuals (male: 2, female: 1). Bat capturing was conducted at a bridge and a nearby forest in Ulju-gun, Ulsan-si. We attached radio transmitters (0.32 g) to the bats and monitored them by using a radio receiver with a Yagi antenna. Home-range analysis of M. aurascens by using 100% minimum convex polygon (MCP) and 95% MCP showed an average of 106.5 ha and 89.3 ha, respectively, and 50% kernel home range (KHR) showed an average of 8.4 ha. Home range overlap of the 3 bats was observed at the bridge and at nearby water bodies as the core areas, and the size of the home range overlap was 7.3 ha by 100% MCP, 5.9 ha by 95% MCP, and 1.6 ha by 50% KHR. The home range for each bat consisted of the main foraging sites, and the types of foraging sites were similar. M. aurascens-01(M-01) used the bridge and nearby water bodies as the nightly main core areas, M. aurascens-02(M-02) used rice fields and water bodies adjacent to the forest as core areas, and M. aurascens-03(M-03) used water bodies and resident areas as core areas. Although rice fields and resident sites represented the core areas of the home ranges of M-02 and M-03, habitat use was the highest near water bodies as the core area for all the 3 bats. The types of day roosts in this study were a wooden house, canopies of a broad-leaved woodland, and banks of rice fields. The roosts in the wooden house and canopies of the broad-leaved woodland were located within the forest, and the roost in the banks of rice fields was also adjacent to the forest. Our results revealed that the main home range and foraging sites of M. aurascens were located near water bodies as the core area, and forests and places adjacent to the forests were used as day roosts.

Time Resolution Improvement of MRI Temperature Monitoring Using Keyhole Method (Keyhole 방법을 이용한 MR 온도감시영상의 시간해상도 향상기법)

  • Han, Yong-Hee;Kim, Tae-Hyung;Chun, Song-I;Kim, Dong-Hyeuk;Lee, Kwang-Sig;Eun, Choong-Ki;Jun, Jae-Ryang;Mun, Chi-Woong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.31-39
    • /
    • 2009
  • Purpose : This study proposes the keyhole method in order to improve the time resolution of the proton resonance frequency(PRF) MR temperature monitoring technique. The values of Root Mean Square (RMS) error of measured temperature value and Signal-to-Noise Ratio(SNR) obtained from the keyhole and full phase encoded temperature images were compared. Materials and Methods : The PRF method combined with GRE sequence was used to get MR temperature images using a clinical 1.5T MR scanner. It was conducted on the tissue-mimic 2% agarose gel phantom and swine's hock tissue. A MR compatible coaxial slot antenna driven by microwave power generator at 2.45GHz was used to heat the object in the magnetic bore for 5 minutes followed by a sequential acquisition of MR raw data during 10 minutes of cooling period. The acquired raw data were transferred to PC after then the keyhole images were reconstructed by taking the central part of K-space data with 128, 64, 32 and 16 phase encoding lines while the remaining peripheral parts were taken from the 1st reference raw data. The RMS errors were compared with the 256 full encoded self-reference temperature image while the SNR values were compared with the zero filling images. Results : As phase encoding number at the center part on the keyhole temperature images decreased to 128, 64, 32 and 16, the RMS errors of the measured temperature increased to 0.538, 0.712, 0.768 and 0.845$^{\circ}C$, meanwhile SNR values were maintained as the phase encoding number of keyhole part is reduced. Conclusion : This study shows that the keyhole technique is successfully applied to temperature monitoring procedure to increases the temporal resolution by standardizing the matrix size, thus maintained the SNR values. In future, it is expected to implement the MR real time thermal imaging using keyhole method which is able to reduce the scan time with minimal thermal variations.

  • PDF

Studies on the External Structure of the Cuticle of Silkworm pupa (Bombyx mori L.) (가잠용외피의 외부구조에 관한 조사연구)

  • 윤종관
    • Journal of Sericultural and Entomological Science
    • /
    • v.20 no.2
    • /
    • pp.10-14
    • /
    • 1978
  • There are relatively many reports have been issued on he active movement of cuticle of larva. which tend to protect their body, however, only a few reports have been disclosed on the cuticle of pupal body except the small portion of rectangle which shown tortoise-shell shape. In this connection, many portion of the external structure of pupal cuticle has been studied and the following. results were found: 1) No. spot of rectangle which is sculptured in the surface of cuticle that born by branching. out of the development of cell in imaginal bud of antenna and head were found. However, in the compound eye of net shaped sculpture was found in the (equation omitted) shaped parts which holding. the diameter of about 8u and the surrounding area has the small bump and the one is dark brown coloured comparing with shape. 2) The sculpture shape of thorax is a little different than in the head. However, (equation omitted) portion is varies from the segment to segment. In general, it is not very clear than the compound eye in the head, the dark brown bump shape is slowly fade a from the prothorax, mesothorax to metathorax. 3) The surface of intersegment membrane is colourless or slightly yellow, and the entire surface has stripped marking with thine lines. 4) In the abdominal segment, there are many and small sculptures in net shape around the (equation omitted) shape portions. 5) The size of sculpture in (equation omitted) portion of abdomen is smaller than one in thorax, and in the same segment, the dorsal is smaller than abdomen and the rear portion of the segment is larger than the front of segment. 6) After the 7th abdominal segment, no intersegmental membrane is found and the cuticle of the external structure is the same as external structure of the segment. 7) The seta is not found in head, compound eye, antenna and wing which portions were subdivided by development of imagined bud of the cell, no seta is found in cuticle of the segment in the general cell of the larva stage and also in the dorsal and intersegmental membrane.

  • PDF

Millimeter-wave LTCC Front-end Module for Highly Integrated Transceiver (고집적 송수신기를 위한 밀리미터파 LTCC Front-end 모듈)

  • Kim, Bong-Su;Byun, Woo-Jin;Kim, Kwang-Seon;Eun, Ki-Chan;Song, Myung-Sun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.10 s.113
    • /
    • pp.967-975
    • /
    • 2006
  • In this paper, design and implementation of a very compact and cost effective front-end module are presented for IEEE 802.16 FWA(fixed Wireless Access) in the 40 GHz band. A multi-layer LTCC(Low Temperature Co-fred Ceramic) technology with cavity process to achieve excellent electrical performances is used to fabricate the front-end module. The wirebond matching circuit design of switch input/output port and waveguide transition to connect antenna are optimally designed to keep transmission loss low. To reduce the size of the front-end module, the dielectric waveguide filter is developed instead of the metal waveguide filter. The LTCC is composed of 6 layers(with the thickness of a layer of 100 um) having a relative dielectric constant of 7.1. The front-end module is implemented in a volume of $30{\times}7{\times}0.8mm^3$ and shows an overall insertion loss < 5.3 dB, and image rejection value > 49 dB.

Terminals of Antennal Receptor Cells in the Antennal Lobe of the Bunenv. Pieris rapae L.(Insects, Lepidoptera) (배추흰나비 뇌의 촉각엽에 뻗은 촉각지각신경세포의 축색종말)

  • 이봉희;김우갑
    • The Korean Journal of Zoology
    • /
    • v.31 no.4
    • /
    • pp.334-343
    • /
    • 1988
  • Five types of synaPses were differentiated in the antennal lobe or Pieris rapoe. aev are in general axo-dendritic synapses and have symmetrical contacts. The type I synapses contain the uniformly round vesicles of medium size, and consist of the 11% of all synapses in the antennal lobe. The type synapses are filled with the small flat and densely arranged (19%). The type III synapses possess medium-sized round vesicles and dense core ones(24%). The type IV synapses are characterized by such three kinds of vesicles as small round, small flat and dense core vesicles(33%). The type V synapses exhibit the presence of medium-sized round, large round and dense core vesicles(13%). The removal of the left antenna on its proximal portion caused the type IV boutons of the above ave types in ipsilateral antennal lobe to turn into dark or semidark degenerative changes. Therefore, it was concluded that many of the antennal receptor cells projected into the brain terminate in the antennal lobe to form type IV synapses together with the dendrites. 배추회나비 뇌의 촉각엽에 있는 신경세포들은 5가지의 신경연접을 형성하는 것으로 관찰되었다. 이 신경연접들은 모두 축색과 수상돌기간의 연접으로 대칭연접이었다. 제1형 신경연접은 축색종말내에 중등도크기의 단형 연접소포를 가지고 있었고, 촉각엽에 있는 5가지의 신경연접중 11%의 출현빈도수로 관찰되었다. 제2형 신경연접의 축색종말에는 장형과 도형의 2가지 연접소포가 포함되어 있었는데, 모두 소형이었으며 이같은 연접소포들이 축색 종말내에서 조밀하게 관찰되었다. 제2형 신경연접의 출현 빈도수는 19%이었다. 제3형 신경연접은 축색 종말내에 중등도크기의 도형 연접소포와 DENSE CORE VESICLE을 포함하고 있었고 그 출현빈도수는 24%이었다. 제4형 신경연접은 축색총말내에 소형의 도형, 소형의 장형 연접소포 및 DENSE CORE VESICLE의 3가지 연접소포를 가지고 있었고 출현빈도수는 촉각엽에서 가장 큰 33%이었다. 제5형 신경연접은 축색종말내에 중등도크기의 원형, 대형의 원형연접소포 및 DENSE CORE VESICLE을 포함하였고 13%의 출현빈도수로 관찰되었다. 배추횐나비의 촉각에 있는 지각신경세포가 뇌의 촉각엽으로 뻗어 들어가 위의 5가지 신경연접중 어느 형을 형성하는지를 관찰하기 위하여 좌측 촉각의 기부를 제거하여 지각신경세포를 절단하였는데 그 결과, 좌측 촉각엽에서 제4형의 신경연접이 퇴행성 변화를 나타내었다. 그러므로 촉각의 지각신경세포는 뇌의 같은 족 촉각엽에 뻗어와 제4형 신경연접을 형성한다고 결론되었다.

  • PDF

16-port Feed Waveguide Array for DBS Reception System Mounted on Vehicle (차량 탑재형 DBS 수신 시스템용 16 포트 급전 도파관 어레이)

  • Min, Gyeong-Sik;Kim, Dong-Cheol
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.39 no.2
    • /
    • pp.92-100
    • /
    • 2002
  • The 16-port feed waveguide array with inductive walls analyzed by Galerkin's method of moments are proposed for the DBS reception system mounted on vehicle. First of all, in order to verify the validity of electromagnetic analysis and design for a $\pi$-junction feed waveguide, it is designed and fabricated at DBS band. The measurement results of a $\pi$-junction feed waveguide agree well with the theoretical ones. Based on this design method, an array design for WR-90 standard waveguide is conducted. Since the width of a $\pi$-junction feed WR-90 standard waveguide is larger than a guided wave length in an array design, the difference of amplitude and phase of 8-port array are calculated 2.3 dB and 62 degrees, respectively. The bandwidth with return loss of -20 dB below is about 220 MHz and it doesn't satisfy DBS band. To solve this problem, we propose a novel design that the width of a $\pi$-junction feed waveguide equals to a guided wave length. By the proposed novel design for 8-port feed waveguide array, the difference of amplitude and phase are decreased 1 dB and 13 degrees, respectively. The broad bandwidth of 700 MHz is also realized. The size of 16-port waveguide away compared with WR-90 array is reduced about 10 cm. The measured antenna gain for the fabricated 16-port feed waveguide array is observed 24 dBi above at DBS band.

An Improved Search Space for QRM-MLD Signal Detection for Spatially Multiplexed MIMO Systems (공간다중화 MIMO 시스템의 QRM-MLD 신호검출을 위한 개선된 탐색공간)

  • Hur, Hoon;Woo, Hyun-Myung;Yang, Won-Young;Bahng, Seung-Jae;Park, Youn-Ok;Kim, Jae-Kwon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.4A
    • /
    • pp.403-410
    • /
    • 2008
  • In this paper, we propose a variant of the QRM-MLD signal detection method that is used for spatially multiplexed multiple antenna system. The original QRM-MLD signal detection method combines the QR decomposition with the M-algorithm, thereby significantly reduces the prohibitive hardware complexity of the ML signal detection method, still achieving a near ML performance. When the number of transmitter antennas and/or constellation size are increased to achieve higher bit rate, however, its increased complexity makes the hardware implementation challenging. In an effort to overcome this drawback of the original QRM-MLD, a number of variants were proposed. A most strong variant among them, in our opinion, is the ranking method, in which the constellation points are ranked and computation is performed for only highly ranked constellation points, thereby reducing the required complexity. However, the variant using the ranking method experiences a significant performance degradation, when compared with the original QRM-MLD. In this paper, we point out the reasons of the performance degradation, and we propose a novel variant that overcomes the drawbacks. We perform a set of computer simulations to show that the proposed method achieves a near performance of the original QRM-MLD, while its computational complexity is near to that of the QRM-MLD with ranking method.

Morphological Differentiation of the Trap in Aquatic and Terrestrial Utricularia Species (서식환경에 따른 통발속(Utricularia) 포충낭의 형태 분화)

  • Lee, Kyoung-Lan;Kim, In-Sun
    • Applied Microscopy
    • /
    • v.40 no.4
    • /
    • pp.237-244
    • /
    • 2010
  • Utricularia forms small, but complex carnivorous trap along the stem either in water or in soil depending upon species. The shapes and sizes of the traps, appendages, and trichomes are known to differ among aquatic, terrestrial and epiphytic species. In the present study, the morphology and microstructure of the trap in aquatic Utricularia japonica and terrestrial U. livida were examined using light and electron microscopy. The aim of this study was to compare the characteristics of trap features between the aquatic and terrestrial species. The trap was found to be comprised of a thin walled bladder with numerous capitate trichomes, two-armed bifid and four-armed quadrifid glands in both species; however, the traps of the two species were different in size, and number and morphology of the trichomes and glands. Aquatic Utricularia was chlorenchymatous with chloroplasts distributed throughout the body, whereas the terrestrial species was translucent without plastids due to an adaptation to underground habitats. Furthermore, the former differed considerably in that the traps developed antenna and appendages around the entrance area. A peculiar trap entrance was also noted in U. livida, which exhibited radiating rows of various trichomes within funnel-shaped tissue. A large number of glandular trichomes covered the entrance area and door surface with four trigger hairs each in the aquatic form but only two in the terrestrial form. The glandular trichomes near the door secreted a large amount of mucilage that temporarily composed the velum in the U. japonica, however, it was not observed in the terrestrial species. All of the aforementioned features were highly related in their structure and function during carnivorous mechanism in Utricularia. The current findings provide important data for further comparison of the different life forms within Utricularia.

Characterization of Schottky Diodes and Design of Voltage Multiplier for UHF-band Passive RFID Transponder (UHF 대역 수동형 RFID 태그 쇼트키 다이오드 특성 분석 및 전압체배기 설계)

  • Lee, Jong-Wook;Tran, Nham
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.7 s.361
    • /
    • pp.9-15
    • /
    • 2007
  • In this paper, we present the design of Schottky diodes and voltage multiplier for UHF-band passive RFID applications. The Schottky diodes were fabricated using Titanium (Ti/Al/Ta/Al)-Silicon (n-type) junction in $0.35\;{\mu}m$ CMOS process. The Schottky diode having $4{\times}10{\times}10\;{\mu}m^{2}$ contact area showed a turn-on voltage of about 150 mV for the forward diode current of $20\;{\mu}A$. The breakdown voltage is about -9 V, which provides sufficient peak inverse voltage necessary for the voltage multiplier in the RFID tag chip. The effect of the size of Schottky diode on the turn-on voltage and the input impedance at 900 MHz was investigated using small-signal equivalent model. Also, the effect or qualify factor of the diode on the input voltage to the tag chip is examined, which indicates that high qualify factor Schottky diode is desirable to minimize loss. The fabricated voltage multiplier resulted in a output voltage of more than 1.3 V for the input RF signal of 200mV, which is suitable for long-range RFID applications.