• Title/Summary/Keyword: anodic polarization

Search Result 271, Processing Time 0.025 seconds

A Kinetic Study of the Aluminum Electrode in Molten 60 Mole Percent $AlCl_3$-40 Mole Percent NaCl at 453${\circ}K$ (용융 (60 몰% $AlCl_3$-40 몰% NaCl) 염 속에서의 알루미늄전극의 반응속도론적 연구)

  • G. F. Uhlig;T. N. Andersen;S. Johns;H. Eyring
    • Journal of the Korean Chemical Society
    • /
    • v.18 no.6
    • /
    • pp.400-407
    • /
    • 1974
  • Steady-state anodic and cathodic polarization curves were developed for the Al electrode in 60 mole %$AlCl_3$-40 mole % NaCl at $180^{\circ}C$$453^{\circ}K$). Ohmic resistance contributed substantially to the anodic polarization at current densities greater than 50 mA/$CM^2$ even with capillary tip placed close to the electrode. This could not be rationalized from the resistivity of the melt, which would lead to a much smaller polarization. It was therefore concluded that a layer of high resistance $AlCl_3$ (or $AlCl_3$-rich melt) formed close to the anode surface. From the IR-corrected anodic Tafel and Allen-Hickling plots an apparent anodic charge-transfer coefficient of ${\alpha}_a$ = (2.3 RT/F)(d log i/d${\eta}$) = $1.5{\pm}0.25$ was obtained. At cathodic current densities greater than approximately 30 mA/$cm^2$, slow ion diffusion and dendrite growth both interfered with the measurement of kinetic parameters.

  • PDF

Anodic Oxidation of Silicon in EPW Solution (EPW 용액에서의 실리콘 양극 산화막 형성에 관한 연구)

  • Bu, Jong-Uk;Kim, Seon-Mi;Kim, Seung-Hui;Kim, Seong-Tae;Gwon, Suk-In
    • Journal of the Korean Vacuum Society
    • /
    • v.2 no.2
    • /
    • pp.181-187
    • /
    • 1993
  • We have studied the anodic oxidation of silicon in the anisotropic etchant of EPW(Ethylenediamine, Pyrocatechol and Water) solution using the cyclic polarization technique. The samples have been characterized by means of X-ray photoelectron spectroscopy(XPS) and secondary ion mass spectrometry (SIMS). The results of cyclic polarization experiments show that the anodic oxides formed on p- and n-type silicon wafers break down at the same potential while breakdown does not occur up to open circuit potential in the case of $p^+$-Si. Strong etch-resistance of $p^+$-XPS. SIMS depth profiles suggest that the critical concentration of boron for etch-stop to occur appears to be much higher than what is widely believed.

  • PDF

An Electrochemical Evaluation on the Corrosion Resistance of Heavy Anticorrosive Paint (중방식도료의 내식성에 관한 전기화학적 평가)

  • Sung Ho-Jin;Kim Jin-Kyung;Lee Myung-Hoon;Kim Ki-Joon;Moon Kyung-Man
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.5
    • /
    • pp.519-525
    • /
    • 2005
  • An electrochemical evaluation on the corrosion resistance for heavy anticorrosive paint(DFT:25um) was carried out for 5 kinds of heavy anticorrosive paints such as high solid epoxy(HE), solvent free epoxy(SE). tar epoxy(TE), phenol epoxy(PE). and ceramic epoxy(CE). Corrosion current densities obtained by Tafel extrapolation method from anodic and cathodic polarization curves didn't correspond with the values obtained by AC impedance measurement, however, the values of polarization resistance obtained from the cyclic voltammogram showed a good tendency corresponding well with the values of AC impedance measurement. Futhermore there was a good correlation against the corrosion resistance evaluation between passivity current density of the anodic polarization curve and diffusion limiting current density of the cathodic polarization curve. And corrosion resistance increased with corrosion potential shifting to noble direction. From the results discussed above. HE and CE had a relatively good corrosion resistance than other heavy anticorrosive paints.

An Evaluation of Degraded Damage for Superaustenitic Stainless Steel by Electrochemical Polarization Technique (전기화학기법에 의한 슈퍼 오스테나이트 스테인리스강의 열화손상 평가)

  • Kwon, Il-Hyun;Lee, Song-In;Baek, Seung-Se;Lee, Jong-Gi;Iino, Y.;Yu, Hyo-Sun
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.143-148
    • /
    • 2001
  • This research was undertaken to clarify effects of thermal aging on electrochemical and mechanical properties of superaustenitic stainless steel. The steel was artificially aged at $300{\sim}650^{\circ}C$ for $240{\sim}10,000hrs$. and investigated at $-196{\sim}650^{\circ}C$ using small punch(SP) test. Also, the change in electrochemical properties caused by effects of thermal aging was investigated using electrochemical anodic polarization test in a KOH electrolyte. Carbides and ${\eta}-phase(Fe_2Mo)$ precipitated in the grain bounderies seem to deteriorate the mechanical properties by decreasing cohesive strength in the grain bounderies and promote the current density observed in electrochemical polarization curves. The electrochemical and mechanical properties of superaustenitic stainless steel was drastically decreased in the specimen aged at $650^{\circ}C$.

  • PDF

Improvement of Corrosion Resistance for Copper Tube by Electrochemical Passivation (전기화학적 부동태화에 의한 동관의 내식성 개선 연구)

  • Min, Sung-Ki;Kim, Kyung-Tae;Hwang, Woon-Suk
    • Corrosion Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.125-130
    • /
    • 2011
  • This study was performed to improve the corrosion resistance and the stability of passive film on copper tube by potentiostatic polarization method in synthetic tap water. Formation of passive film was carried out by anodic potentiostatic polarization at various passivation potentials and passivation times in 0.1 M NaOH solution. Stability of passive film and corrosion resistance was evaluated by self-activation time, ${\tau}_0$ from passive state to active state on open-circuit state in 0.1 M NaOH solution. Addition of polyphosphate in NaOH solution prolonged the self-activation time and improved the corrosion resistance, and the addition of 5 ppm polyphosphate was most effective. It was also observed that better corrosion resistance was obtained by potentiostatic polarization at 1.0 V (vs. SCE) than at any other passivation potentials. Passivated copper tube showed perfect corrosion resistance for the immersion test in synthetic tap water showing that the anodic potentiostatic polarization treatment in 0.1 M NaOH with 5 ppm polyphosphate solution would be effective in improving the corrosion resistance and preventing the blue water problem.

Corrosion analysis of the duplex aluminum alloys (듀플렉스 알루미늄 합금의 내식성 분석)

  • Choi, In Kyu;Kim, Si Myeong;Kim, Sang Ho
    • Journal of the Korean institute of surface engineering
    • /
    • v.48 no.5
    • /
    • pp.227-232
    • /
    • 2015
  • Corrosion characteristic of the duplex Al-Mg-Si alloys with low, commercial and high solute contents were studied using an anodic polarization test in 1M NaCl solution at room temperature. Polarization range condition of the experiment were form .0.3V to .1.3V with a 0.2 mV scanning speed. The exchange current density means corrosion rate of the low solute alloy was low as about $16.29{\mu}A/cm^2$, and that of the high solute alloy was high as $84.92{\mu}A/cm^2$. The difference was mainly attributed to the inter-granular precipitates $Mg_2Si$ and Si which could make a galvanic corrosion on the aluminum base. The amount of precipitates was greater in high solute alloy at mainly in grain boundary. While, the extruded alloys had better corrosion resistance than the cast alloy because the silicon precipitates become coarse during the extrusion process.

An Investigation of Pulse Anodization Duty Ratio and Sealing Treatment on the Corrosion Behavior of the Anodic Coating Layer in Magnesium AZ31B

  • Setiawan, Asep Ridwan;Rachman, Muhammad Dani
    • Corrosion Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.45-51
    • /
    • 2021
  • In this work, we describe the effect of pulse anodizing duty ratio on the corrosion resistance of anodic films in magnesium AZ31B. The process involves the application of square pulse potential for a constant period with a duty ratio varying from 40, 60 and 80%. In several samples, a sealing treatment for 30 minutes was conducted after anodization in order to seal the pores available in the anodic layer. After anodizing, the surface morphology of the anodic layer was examined using a scanning electron microscope (SEM Hitachi SU3500). The corrosion characteristics of the sample were evaluated through an open circuit potential (OCP) and potentiodynamic polarization test using potentiogalvanostat. SEM observation shows that the increase of anodization duty ratio (α) results in a more uniform anodic layer, with fewer pores and cracks. The increase of duty ratio (α) decreases the OCP value from approximately -1.475 to about -1.6 Volt, and significantly improves the corrosion resistance of the anodic coating by 68%. The combination of anodization and sealing treatment produces an anodic coating with a very low corrosion rate of 4.4 mpy.

Corrosion Resistance Evaluation of Aluminum Thermal Spray Coated AA5083-H321 (알루미늄 열용사 코팅된 AA5083-H321의 내식성 평가)

  • Il-Cho Park;Sungjun Kim;Min-Su Han
    • Corrosion Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.108-114
    • /
    • 2023
  • In this study, anti-corrosion effect was investigated through various electrochemical experiments after applying Al thermal spraying technology to AA5083-H321. Open circuit potential and anodic polarization curves were analyzed through electrochemical experiments in natural seawater. The shape of the surface was observed using a scanning electron microscope (SEM) and a 3D microscope before and after the experiment. Component and crystal structure were analyzed through EDS and XRD. As a result, the surface roughness of AA5083-H321 and the Al thermal sprayed coating layer increased due to surface damage caused by anodic dissolution reaction during the anodic polarization experiment. The corrosion rate of AA5083-H321 was relatively low because the Al thermal spray coating layer contained structural defects such as pores and crevices. Nevertheless, the open circuit potential of the Al thermal spray coating layer in natural seawater was measured about 0.2 V lower than that of AA5083-H321. Thus, a sacrificial anode protection effect can be expected.

Affecting of Corrosion Potential and Current Density on Variation Polarization Curves with Polyvinylchloride (I)

  • Choi, Chil-Nam;Yang, Hyo-Kyung;Jung, Oh-Jin
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.2 no.2
    • /
    • pp.91-98
    • /
    • 1998
  • In this study, we carried out the experiments for measuring the variations of corrosion potential and current density for polarization curves with polyvinylchloride. The results exhibited especially the influence affecting the corrosion potential and various conditions (temperature, day, pH, bacteria, and added salt). The second anodic current density peak and the minimum passive current density are designated $I_P/I_0,$ respectively. The value of $I_P/I_O$ is used as a measurement for the extent of degradation of the polyvinylchloride. The potentiodpnamics parameters of the corrosion were obtained using Tafel equation.

  • PDF

The Effect on the Wear-Corrosion Behavior of Ductile Cast Iron in the Various pH Environments (구상흑연주철재의 마멸-부식특성에 미치는 pH의 영향)

  • 임우조;박동기
    • Tribology and Lubricants
    • /
    • v.19 no.1
    • /
    • pp.31-35
    • /
    • 2003
  • This paper reports the studies on the wear-corrosion behavior of ductile cast iron in the various pH environments. In the variety of pH solutions, corrosion and wear-corrosion loss of GCD 600 were investigated. Also, the anodic polarization test of GCD 600 using potentiostat/galvanostat was carried out. And rubbed surface of GCD 60 using scanning electron micrographs after immersion and wear-corrosion test was examined in the environment of various pH values. The main results are as following In alkali zone, the wear-corrosion loss of GCD 600 increases, but corrosion loss decreases. The unevenness and crack of wear-corrosion surface in neutral zone becomes duller than that in alkali zone. As the corrosive environment is acidified, wear-corrosion behavior of GCD 600 with passing immersion time becomes sensitive.