• 제목/요약/키워드: angle standard

검색결과 930건 처리시간 0.024초

전압변성기 비교 측정 장치의 비오차 및 위상각 오차의 직선성 평가기술 (Evaluation Technique of Linearity of Ratio Error and Phase Angle Error of Voltage Transformer Comparison Measurement Equipment)

  • 정재갑;박영태;권성원
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권9호
    • /
    • pp.470-474
    • /
    • 2004
  • Both ratio error and phase angle error in voltage transformer(VT) depend on values of burden of VT used. A method of evaluation for linearity of ratio error and phase angle error in VT measurement equipment have been developed using the standard resistance burdens, with negligible AC-DC resistance difference less than $10^-6$. These burden consists of five standard resistors, with nominal resistance of 100 $\Omega$, 1 k$\Omega$, 10 k$\Omega$, 100 k$\Omega$, and 1 M$\Omega$. The developed method has been applied in VT measurement equipment of industry and the validity of the developed method has been verified by showing the consistency of the result of linearity obtained using VT with wide ratio error.

견, 두부 형태별 Shoulder Pad 두께에 관한 연구 - 여자대학생을 중심으로 - (A Study on the Reaction Somatotype of Shoulder and Neck with Thickness of Shoulder Pad - The Subject of the College Woman -)

  • 이은정;김순구;박정순
    • 한국의류학회지
    • /
    • 제15권2호
    • /
    • pp.139-150
    • /
    • 1991
  • The purpose of this study is to do the Somatotype classification according to the type of shoulder-neck and to give the thinkness of shoulder pad according to them. Therefore this study was measurement body size of 201 and the somatotypes were classified as their plumb line. The standard somatotype of this measurement was classified as 9 type according to its angle of shoulder inclination and neck length. Pads which have different thickness (1 cm, 1.5 cm, 2 cm) were attached to the 9 body type and the set-in sleeve blouse and raglan sleeve blouse were made and tring test and sensory test were accomplished. The results of this study were as follows: 1 . Classification of shoulder-neck relationship. Angles of shoulder inclination ($15^{\circ},\;21^{\circ},\;27^{\circ}$), lock lenaths (10 cm, 12.5 cm, 15 cm) were classi- fied as 3 type each and these types were combined as 9 types. II . The result of angle difference of shoulder inclination according to pad thickness. 1) In case of set-in pad. angle is increased $5.75^{\circ}$ per 1 cm of pad thickness. 2) In case of raglan pad. angle is increased $6.45^{\circ}$ per 1 cm of pad thickness. III. The most fit pad thickness to the 9 types. In case of set-in sleeve blouse. 1) High shoulder-long neck, Standard shoulder-long neck Low shoulder-long neck, Stan-dard shoulder·standard neck. Low shoulder-standard neck: 1.5 cm. 2) High shoulder-standard neck, Standard shoulder-short neck, Low shoulder-short neck: 1 cm. 3) High shoulder-short neck: 0 cm(without pad) In case of raglan sleeve blouse. 4) High shoulder-long neck, Standard shoulder-long neck, Low shoulder·long neck, Stan-dard shoulder-standard neck, Low shoulder-standard neck: 1.5 cm. 5) High shoulder-standard neck, Standard shoulder-short neck, Low-shoulder-short neck: 1 cm. 6) High shoulder-short neck: 0 cm(without pad)

  • PDF

새로운 발 사방향 검사법의 유용성에 관한 연구 (A Study on the Usefulness of the New Foot Oblique Projection)

  • 김민석;주영철;이승근
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권5호
    • /
    • pp.443-449
    • /
    • 2021
  • In this study, the purpose is to present the foot inclination angle for realizing an image similar to that of the existing examination method and to present the clinical usefulness of the new examination method through comparison between the existing examination method and the newly designed standing foot oblique projection. A foot phantom was used, and the magnification of the image according to the angle was quantitatively evaluated by attaching a nut to the position of the cuboid of the phantom. The internal oblique image acquired using a 30° wedge was set as the standard image. And that image was compared with the images acquired by changing the angle of the foot from 20° to 65° at intervals of 5°. Image evaluation was performed by 3 radiological technologists, and qualitative evaluation using a Likert 5-point scale for evaluation items of true oblique view and quantitative evaluation of the value obtained by measuring the diameter of a nut in each image were performed as image evaluation. For data analysis, reliability analysis between the measure and comparative analysis of the average value for each angle were performed. The qualitative evaluation score for each image was 4.5 to 5 points for most questions in the case of the standard image. And 4 points or less for most questions in the images with a foot angle of 45° or less, and an evaluation score close to the standard image was obtained in the image of 50° or more. And in the quantitative evaluation, the diameter of the nut was measured to be 9.28~9.56 mm. The qualitative evaluation showed a reliability of 0.95~1.0 and the quantitative evaluation was 0.62. As a result of comparing and analyzing the average of the quantitative and qualitative average values for each angle image, the group with the average value most similar to the standard image was images obtained at 55° and 60°, and in the post-analysis, the images of both groups were the same group as the standard image(p<0.01). As a result of this study, it was found that the angle of inclination of the foot for realizing the image most similar to the existing image in the standing foot oblique projection is 55°~60°. In addition, if this test method is applied to the clinic, it is believed that it will help prevent safety accidents such as falls during the test and improve test efficiency by minimizing the movement of patients for the test.

2차 공기 주입각이 소각로 내부의 온도 분포 균일도에 미치는 영향 (Effects of the angle of secondary air inlet on the uniformity of temperature distribution inside an incinerator)

  • 김성준;민인홍;박명호;박민주
    • 한국전산유체공학회지
    • /
    • 제5권3호
    • /
    • pp.8-15
    • /
    • 2000
  • This research is aimed to find out how the inlet angle of secondary air affects the uniformity of temperature distribution inside a small incinerator. A commercial code, PHOENICS, is used to simulate the thermal-flow field of an incinerator. The computational grid system is constructed by Multi-Block technique provided by PHOENICS. Numerical experiments are done with the five different angles of secondary air inlet. The uniformity of temperature distribution is evaluated by checking the standard deviation of temperature distribution in an incinerator. The computational results show that there is the minimum value of standard deviation at the certain angle of secondary air inlet, which means that there is an optimum angle of secondary air inlet that could improve the uniformity of temperature distribution in an incinerator. The optimum angle of secondary air inlet is between 30 degree and 45 degree in this particular case.

  • PDF

전기용량 부담을 이용한 전압변성기 비교 측정 시스템의 비오차 및 위상각 오차의 직선성 평가기술 (Evaluation Technique of Linearity of Ratio Error and Phase Angle Error of Voltage Transformer Comparison Measurement System Using Capacitor Burden)

  • 정재갑;김한준;권성원;김명수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권6호
    • /
    • pp.274-278
    • /
    • 2005
  • Voltage transformer(VT) comparison measurement system is usually used for measurements of ratio error and phase angle error of VT made in industry. Both ratio error and phase angle error in VT are critically influenced by values of burden of VT used. External burden effects on both ratio error and phase angle error in VT are theoretically calculated. From the theoretical calculation, a method of evaluation for linearity of ratio error and phase angle error in VT measurement system have been developed using the standard capacitive burdens, with negligible dissipation factor less than 10$^{-4}$. These burden consists of five standard capacitors, with nominal capacitance of 1.1 $\mu$F, 1 $\mu$F, 0.1 $\mu$F, 0.01 $\mu$F, 0.001 $\mu$F. The developed method has been applied in VT measurement system of industry, showing in good consistency and linearity within 0.001 $\%$ between theoretical and measured values.

파노라마방사선 사진에서의 하악과두구조 (THE STRUCTURE OF THE MANDIBULAR CONDYLE IN THE PANORAMIC RADIOGRAPH)

  • 최순철
    • 치과방사선
    • /
    • 제20권2호
    • /
    • pp.163-167
    • /
    • 1990
  • The author has evaluated the panoramic image of the mandibular condyle according to its horizontal condylar angle (0˚, 10˚, 20°, 30°, 40°) and mandibular position (standard, 25㎜ forward and reverse position). The results were as follows: 1. The larger the horizontal condylar angle was, the larger the horizontal magnification was in all positions. 2. In case of small horizontal condylar angle, profile view could be obtained in 25㎜ forward and reverse position. 3. In case of large horizontal condylar angle, profile view could not be obtained in any positions.

  • PDF

성인편마비환자의 지팡이 길이 측정법 비교 (A Comparison of Methods for Estimating the Proper Cane Length for Hemiplegic Patients)

  • 이충휘;김종만
    • 한국전문물리치료학회지
    • /
    • 제3권2호
    • /
    • pp.1-7
    • /
    • 1996
  • Two standard methods of cane length measurements were compared to find which methods really achieve the elbow flexion of 20 degrees to 30 degrees Twenty-four patients with hemiplegia who were ambulatory participated in this study. Method I : Length of the cane measured from the floor to the top of the greater trochanter. Method II : Length of the cane measured from the floor to the distal wrist crease with the arm at the side. Using an adjustable cane, each individual was fitted according to the two methods, and elbow angle was measured after each adjustment. The elbow angle according to Method I and Method II was $46.4{\pm}20$, $44.3{\pm}12.2$, respectively. No significant difference was found in the elbow angle or the cane length between the two methods. Of the 24 participants, 5(20.8%) measured according to method I and 3(12.5%) measured according to method II showed the elbow angle between 20 degrees and 30 degrees. These low predictive rates of agreement between ideal cane length and actually achieved elbow angle showed that these two methods which have conventionally been accepted as a standard to measure ideal cane length need to be revised through further research.

  • PDF

문서입력 작업 시 컴퓨터 키보드 유형이 손목관절의 운동학적 특성에 미치는 영향 (The Effect of Standard Keyboard and Fixed-Split Keyboard on Wrist Posture During Word Processing)

  • 권혁철;정동훈;공진용
    • 한국전문물리치료학회지
    • /
    • 제11권1호
    • /
    • pp.35-43
    • /
    • 2004
  • There were two purposes of this study. The first was to research the effects of standard and fixed-split keyboards on wrist posture and movements during word processing. The second was to select optimal computer input devices in order to prevent cummulative trauma disorder in the wrist region. The group of subjects consisted of thirteen healthy men and women who all agreed to participate in this study. Kinematic data was measured from both wrist flexion and extension, and wrist radial and ulnar deviation during a 20 minute period of word processing work. The measuring tool was an electrical goniometer, and was produced by Biometrics Cooperation. The results were as follows: 1. The wrist flexion and extension at resting starting position were not significantly different (p>.05), however the angle of radial and ulnar deviation were significantly different in standard and split keyboard use during word processing (p<.05). 2. In the initial 10 minutes, the dynamic angle of wrist flexion and extension were not significantly different (p>.05), however the dynamic angle of radial and ulnar deviation was significantly different in standard and split keyboard use during word processing (p<.05). These results suggest that the split keyboard is more optimal than the standard keyboard, because it prevented excessive ulnar deviation during word processing.

  • PDF

Standard Exact Couch와 6D Robotic Couch를 이용한 광자선의 조사각에 따른 선량 감쇠에 대한 연구 (The Dose Attenuation according to the Gantry Angle and the Photon Energy Using the Standard Exact Couch and the 6D Robotic Couch)

  • 김태형;오세안;예지원;박재원;김성규
    • 한국의학물리학회지:의학물리
    • /
    • 제27권2호
    • /
    • pp.79-85
    • /
    • 2016
  • 본 연구는 방사선치료에서 방사선 선량전달의 정확도를 높이기 위해 두 종류의 치료테이블 6D robotic couch (BrainLab, Feldkirchen, Germany)와 Standard exact couch (Varian Exact couch$^{TM}$, Varian Medical Systems, Milpitas, CA, USA)를 이용하여 Rail의 위상(In-Out)에 따른 상대선량을 측정하여, 선량감쇠율을 계산하였다. 치료테이블을 투과하는 조사에너지의 조사각 $0^{\circ}$에서 $360^{\circ}$까지의 상대 선량을 각각 측정하였으며, 조사각이 $0^{\circ}$일 때 측정된 선량을 기준으로 하여 $5^{\circ}$ 간격으로 선량의 변화를 측정하고 선량 감쇠율을 계산하였다. Standard exact couch의 광자선 에너지는 6 MV와 10 MV를 사용하였으며 치료테이블의 Rail 위상(In position, Out position)에 따른 상대 선량을 측정하였다. 6D robotic couch는 6 MV와 15 MV의 광자선 에너지를 사용하였다. Standard exact couch의 광자선의 최대 선량차이는 Rail In position에서 6 MV ($175^{\circ}$), 10 MV ($175^{\circ}$)일 때, 선량차이는 각각 16.53%, 12.42%, Out position에서 6 MV ($225^{\circ}$), 10 MV ($225^{\circ}$)일 때, 선량차이는 각각 15.15%, 9.96%였다. 6D robotic couch에서는 6 MV ($130^{\circ}$)와 15 MV ($130^{\circ}$)일 때, 선량차이는 각각 6.82%, 4.92%였다. 본 연구를 통해, 치료테이블의 종류에 따른 선량 감쇠율은 6D robotic couch가 Standard exact couch보다 6 MV에서 조사각 $180^{\circ}$ 기준 약 1% 더 발생함을 확인하였고, Stnadard exact couch인 경우, Sliding rail의 위상(In position, Out position)에 따라 선량 감쇠가 급격히 변화하는 것을 확인하였다.

간접평판형 검출기에서 변조전달함수 측정 시 Edge 각도에 따른 비교 연구 (Comparison of Modulation Transfer Function in Measurements by Using Edge Device angle in Indirect Digital Radiography)

  • 민정환;정회원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권4호
    • /
    • pp.259-263
    • /
    • 2019
  • This study was purpose to compare image quality of Indirect digital radiography (IDR) system by using the International electro-technical commission standard(IEC 62220-1) which were applied to IEC in medical imaging. To evaluation the analysis of Modulation transfer function(MTF) measurements edge device each angle by using edge method. In this study, Aero (Konica, Japan) which is Indirect flat panel detector(FPD) was used, the size of image receptor matrix $1994{\times}2430$ which performed 12bit processing and pixel pitch is $175{\mu}m$. In IEC standard method were applied to each angle were compared. The results of shown as LSF at $2.0^{\circ}$ and $3.0^{\circ}$ angeles. Shape is constant and shows smooth shape. The amount of data seemed reasonable and 2.19 cycles/mm and 2.01 cycles/mm at a spatial frequency of $2.0^{\circ}$ and $3.0^{\circ}$ at an MTF value of 0.1. At an MTF value of 0.5, the spatial frequencies were $2.0^{\circ}$ and 1.11 cycles/mm and 0.93 cycles/mm at an angle of $3.0^{\circ}$. This study were to evaluate MTF by setting the each $2{\sim}3^{\circ}$ each angle and to suggest the quantitative methods of measuring by using IEC.