• Title/Summary/Keyword: angiographic

Search Result 300, Processing Time 0.03 seconds

Reappraisal of Anatomic Outcome Scales of Coiled Intracranial Aneurysms in the Prediction of Recanalization

  • Lee, Jong Young;Kwon, Bae Ju;Cho, Young Dae;Kang, Hyun-Seung;Han, Moon Hee
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.6
    • /
    • pp.342-348
    • /
    • 2013
  • Objective : Several scales are currently used to assess occlusion rates of coiled cerebral aneurysms. This study compared these scales as predictors of recanalization. Methods : Clinical data of 827 patients harboring 901 aneurysms treated by coiling were retrospectively reviewed. Occlusion rates were assessed using angiographic grading scale (AGS), two-dimensional percent occlusion (2DPO), and volumetric packing density (vPD). Every scale had 3 categories. Followed patients were dichotomized into either presence or absence of recanalization. Kaplan-Meier analysis was conducted, and Cox proportional hazards analysis was performed to identify surviving probabilities of recanalization. Lastly, the predictive accuracies of three different scales were measured via Harrell's C index. Results : The cumulative risk of recanalization was 7% at 12-month, 10% at 24-month, and 13% at 36-month of postembolization, and significantly higher for the second and third categories of every scale (p<0.001). Multivariate-adjusted hazard ratios (HRs) of the second and third categories as compared with the first category of AGS (HR : 3.95 and 4.15, p=0.004 and 0.001) and 2DPO (HR : 4.87 and 3.12, p<0.001 and 0.01) were similar. For vPD, there was no association between occlusion rates and recanalization. The validated and optimism-adjusted C-indices were 0.50 [confidence (CI) : -1.09-2.09], 0.47 (CI : -1.10-2.09) and 0.44 (CI : -1.10-2.08) for AGS, 2DPO, and vPD, respectively. Conclusion : Total occlusion should be reasonably tried in coiling to maximize the benefit of the treatment. AGS may be the best to predict recanalization, whereas vPD should not be used alone.

Improved Biocompatibility of Intra-Arterial Poly-L-Lactic Acid Stent by Tantalum Ion Implantation : 3-Month Results in a Swine Model

  • Kim, Kangmin;Park, Suhyung;Park, Jeong Hwan;Cho, Won-Sang;Kim, Hyoun-Ee;Lee, Sung-Mi;Kim, Jeong Eun;Kang, Hyun-Seung;Jang, Tae-Sik
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.6
    • /
    • pp.853-863
    • /
    • 2021
  • Objective : Biodegradable poly-L-lactic acid (PLLA) with a highly biocompatible surface via tantalum (Ta) ion implantation can be an innovative solution for the problems associated with current biodegradable stents. The purpose of this study is to develop a Taimplanted PLLA stent for clinical use and to investigate its biological performance capabilities. Methods : A series of in vitro and in vivo tests were used to assess the biological performance of bare and Ta-implanted PLLA stents. The re-endothelialization ability and thrombogenicity were examined through in vitro endothelial cell and platelet adhesion tests. An in vivo swine model was used to evaluate the effects of Ta ion implantation on subacute restenosis and thrombosis. Angiographic and histologic evaluations were conducted at one, two and three months post-treatment. Results : The Ta-implanted PLLA stent was successfully fabricated, exhibiting a smooth surface morphology and modified layer integration. After Ta ion implantation, the surface properties were more favorable for rapid endothelialization and for less platelet attachment compared to the bare PLLA stent. In an in vivo animal test, follow-up angiography showed no evidence of in-stent stenosis in either group. In a microscopic histologic examination, luminal thrombus formation was significantly suppressed in the Ta-implanted PLLA stent group according to the 2-month follow-up assessment (21.2% vs. 63.9%, p=0.005). Cells positive for CD 68, a marker for the monocyte lineage, were less frequently identified around the Ta-implanted PLLA stent in the 1-month follow-up assessments. Conclusion : The use of a Ta-implanted PLLA stent appears to promote re-endothelialization and anti-thrombogenicity.

Stereotactic Radiosurgery for Dural Arteriovenous Fistulas Involving the Transverse-Sigmoid Sinus : A Single Center Experience and Review of the Literatures

  • Baek, Hong-Gyu;Park, Seong-Hyun;Park, Ki-Su;Kang, Dong-Hun;Hwang, Jeong-Hyun;Hwang, Sung-Kyoo
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.4
    • /
    • pp.458-466
    • /
    • 2019
  • Objective : We retrospectively assessed the efficacy of stereotactic radiosurgery (SRS) for dural arteriovenous fistulas (DAVFs) involving the transverse-sigmoid sinus and analyzed the angiographic and clinical results with our 8-year experience. Methods : Nine patients with intracranial DAVFs involving the transverse-sigmoid sinus underwent SRS using a Gamma $Knife^{(R)}$ (Elekta Inc., Atlanta, GA, USA) between 2009 and 2016. Five patients underwent SRS for residual DAVFs after embolization and four patients were treated with SRS alone. The median target volume was $1.9cm^3$ (range, 0.8-14.2) and the median radiation dose of the target was 17 Gy (range, 16-20). The median follow-up period was 37 months (range, 7-81). Results : Pulsating tinnitus (33%) was the most common symptom. DAVFs were completely obliterated in four patients (44%) and subtotally obliterated in five (56%). Six patients (67%) showed complete recovery of symptoms or signs, and three (33%) showed incomplete recovery. One patient experienced a recurrent seizure. Adverse radiation effects after SRS occurred in one patient (11%). The total obliteration rates after SRS were 16.7%, 37.5%, and 68.7% at 1, 2, and 3 years, respectively. The median interval from SRS to total obliteration of the fistula was 31 months (range, 12-38). The rates at which the symptoms started to improve were 40% at 1 month and 80% at 2 months after SRS. Symptoms started to improve at a median of 5 weeks after SRS (range, 3-21). Conclusion : SRS with or without embolization is a safe and effective treatment to relieve symptoms and obliterate DAVFs on the transverse-sigmoid sinus.

Efficacy and Safety of Endovascular Treatment in Patients with Internal Carotid Artery Occlusion and Collateral Middle Cerebral Artery Flow

  • Kim, Yong-Won;Kang, Dong-Hun;Kim, Yong-Sun;Hwang, Yang-Ha
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.2
    • /
    • pp.201-208
    • /
    • 2019
  • Objective : In patients with internal carotid artery (ICA) occlusion, collateral middle cerebral artery (MCA) flow has a protective role against ischemia. However, some of these patients may experience initial major neurological deficits and major worsening on following days. Thus, we investigated the safety and efficacy of endovascular treatment (EVT) for ICA occlusion with collateral MCA flow by comparing clinical outcomes of medical treatment versus EVT. Methods : The inclusion criteria were as follows : 1) acute ischemic stroke with ICA occlusion and presence of collateral MCA flow on transfemoral cerebral angiography (TFCA) and 2) hospital arrival within 12 hours from symptom onset. The treatment strategy was made by the attending physician based on the patient's clinical status and results of TFCA. Results : Eighty-one patients were included (30 medical treatment, 51 EVT). The EVT group revealed a high incidence of intracranial ICA occlusion, longer ipsilesional MCA contrast filling time, and a similar rate of favorable clinical outcome despite a higher mean baseline the National Institutes of Health Stroke Scale (NIHSS) score. By binary logistic regression analysis, intravenous recombinant tissue plasminogen activator and EVT were independent predictors of favorable clinical outcome. In subgroup analysis based on stroke etiology, the non-atherosclerotic group showed a higher baseline NIHSS score, higher incidence of EVT, and a higher rate of distal embolization during EVT in comparison with the atherosclerotic group. Conclusion : In patients with ICA occlusion and collateral MCA flow, decisions regarding treatment strategy based on TFCA can help achieve favorable clinical outcomes. EVT strategy with respect to etiology of ICA occlusion might help achieve better angiographic outcomes.

Selective Temporary Stent-Assisted Coil Embolization for Intracranial Wide-Necked Small Aneurysms Using Solitaire AB Retrievable Stent

  • Heo, Han Yong;Ahn, Jae Guen;Ji, Cheol;Yoon, Won Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.1
    • /
    • pp.27-34
    • /
    • 2019
  • Objective : Stent-assisted coil embolization of intracranial wide-necked aneurysm requires long-term postoperative antiplatelet therapy to prevent in-stent thrombosis. This study aimed to demonstrate results of temporary stent placement for coiling wide necked small intracranial aneurysms, which eliminated need for antiplatelet agents, and to discuss its feasibility and safety. Methods : Data of 156 patients who underwent stent-assisted coil embolization between 2011 and 2014 were retrospectively analyzed. Thirteen cases of temporary stent-assisted coil embolization were included, and their clinical and radiological results were evaluated. Results : The aneurysms treated were all unruptured except one case. All of them had wide neck with mean dome-to-neck ratio of 0.96 and were small-sized aneurysms with mean maximal diameter of 4.2 mm. There was no technical failure in retrieval of stent after completion of embolization of the target aneurysm. Immediate angiography revealed 11 complete and two partial embolization (one residual neck and one residual aneurysm). Two cases encountered thrombosis complication, and they were managed without neurological sequelae. The mean follow-up period was 43 months, angiographic follow-up revealed two cases with minor recurrence, and clinical outcome was good with modified Rankin scale score of 0. Conclusion : Temporary stent-assisted coil embolization of small wide-necked intracranial aneurysm using fully retrievable stent appears safe and effective. Further application and evaluation of this technique in more cases with larger size aneurysm is warranted.

Transarterial Embolization of Intracranial Arteriovenous Fistulas with Large Venous Pouches in the Form of Venous Outlet Ectasia and Large Venous Varix or Aneurysm : Two Centers Experience

  • Deniwar, Mohamed Adel;Ahmad, Saima;Eldin, Ashraf Ezz
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.1
    • /
    • pp.30-39
    • /
    • 2022
  • Objective : There are different types of cerebral vascular malformations. Pial arteriovenous fistulas (PAVFs) and dural arteriovenous fistulas (DAVFs) are two entities; they consist of one or more arterial connections to a single venous outlet without a true intervening nidus. The high turbulent flow of PAVFs and aggressive DAVFs with cortical venous reflux can result in venous outflow varix and aneurysmal dilatation. They pose a significant challenge to transvenous embolization (TVE), stereotactic radiosurgery, and surgical treatment. We aim to share our centers' experience with the transarterial embolization (TAE) for arteriovenous fistulas (AVFs) with large venous pouches and to report the outcome. Methods : The authors' two institutions' databases were retrospectively reviewed from February 2017 to February 2021. All patients with intracranial high flow PAVFs and aggressive DAVFs with venous outlet ectasia and large venous varix and were treated by TAE were included. Results : Fifteen patients harboring 11 DAVFs and four PAVFs met our inclusion criteria. All patients underwent TAE in 17 sessions. Complete angiographic obliteration was achieved after 14 sessions in 12 patients (80%). Four patients (25%) had residual after one TAE session. Technical failure was documented in one patient (6.7%). Fourteen patients (93.3%) had favorable functional outcome (modified Rankin score 0-2). Conclusions : TAE for high flow or aggressive intracranial AVFs is a safe and considerable treatment option, especially for those associated with large venous pouches that are challenging and relatively high-risk for TVE.

True Posterior Communicating Artery Aneurysms with High Risk of Rupture despite Very Small Diameter

  • Shin, Dong Gyu;Park, Jaechan;Kim, Myungsoo;Kim, Byoung-Joon;Shin, Im Hee
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.2
    • /
    • pp.215-223
    • /
    • 2022
  • Objective : This retrospective study investigated the clinical and angiographic characteristics of ruptured true posterior communicating artery (PCoA) aneurysms in comparison with junctional PCoA aneurysms presenting with a subarachnoid hemorrhage. Methods : The medical records and radiological data of 93 consecutive patients who underwent three-dimensional rotational angiography and surgical or endovascular treatment for a ruptured junctional or true PCoA aneurysm over an 8-year period were examined. Results : The maximum diameter of the ruptured true PCoA aneurysm (n=13, 14.0%) was significantly smaller than that of the ruptured junctional PCoA aneurysms (n=80, 4.45±1.44 vs. 7.68±3.36 mm, p=0.001). In particular, the incidence of very small aneurysms <4 mm was 46.2% (six of 13 patients) in the ruptured true PCoA aneurysm group, yet only 2.5% (two of 80 patients) in the ruptured junctional PCoA aneurysm group. Meanwhile, the diameter of the PCoA was significantly larger in the true PCoA aneurysm group than that in the junctional PCoA aneurysm group (1.90±0.57 vs. 1.15±0.49 mm, p<0.001). In addition, the ipsilateral PCoA/P1 ratio was significantly larger in the true PCoA aneurysm group than that in the group of a junctional PCoA aneurysm (mean PCoA/P1 ratio±standard deviation, 2.67±1.22 vs. 1.14±0.88; p<0.001). No between-group difference was identified for the modified Fisher grade, clinical grade at admission, and 3-month modified Rankin Scale score. Conclusion : A true PCoA aneurysm was found to be associated with a larger PCoA and ruptured at a smaller diameter than a junctional PCoA aneurysm. In particular, the incidence of a ruptured aneurysm with a very small diameter <4 mm was significantly higher among the patients with a true PCoA aneurysm.

Hemodynamic Consideration for Endoleak and Aneurysm Size Change after the Stent-Graft Application of Aortic Aneurysm

  • Park, Jea-Hyung;Jae, Hwan-Joon;Lee, Whal;Chung, Jin-Wook
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.2 no.2
    • /
    • pp.10-15
    • /
    • 2004
  • Purpose: In the treatment of aortic aneurysm, endovascular stent-graft application has become an established method of treatment. To observe the outcomes of the procedure as the size change of aneurysm in relation with endoleak, a retrospective analysis was done for the consecutive cases who undertook the procedure. Materials & Method: Stent-graft was applied to the aortic aneurysm in 33 patients. The location of the aneurysm was thoracic in 11 patients and abdominal in 22 patients. CT angiographic was done for the follow-up evaluation to analyze the aneurysm size and the presence of endoleak. Results: Technical success rate was 97% (32/33). The primary success rate without endoleak was 84% (28/33). The secondary success was 90% (30/33). During the follow-up period of 3 months to 7years and 6months in 26 patients, a secondary endoleak developed in 5 cases. Post-implantation syndrome developed in 17 cases (51%). Among the 14 cases with follow-up imaging data for size, endoleak was negative in 10 cases. The aneurysm decreased in 5 cases, stable in size in 4 cases and enlarged in one case (10%).Among the 4 cases with endoleak positive, the aneurysm enlarged in two cases (50%). Conclusion: In the stent-graft application for aortic aneurysm, there is high chance of decrease of aneurysm size in those cases with endoleak negative. However, the aneurysm may increase and eventually rupture in the cases with en do leak positive. Close observation with CT angiography is necessary for the evaluation for the presence of endoleak and size change.

  • PDF

Morphology of middle cerebral artery using computed tomography angiographic study in a tertiary care hospital

  • Urvi Sharma;Suman Verma;Subathra Adithan
    • Anatomy and Cell Biology
    • /
    • v.56 no.3
    • /
    • pp.360-366
    • /
    • 2023
  • Increased tortuosity of vessel is associated with high incidence of plaque formation leading to atherosclerosis. Surgical procedures are done after analyzing morphology of middle cerebral artery (MCA). However, literature describing MCA morphology using computed tomography angiography (CTA) is limited, so this study was planned to determine its incidence in Indian population. Datasets of CTA from 289 patients (180 males and 109 females), average age: 49.29±16.16 years (range: 11 to 85 years), from a tertiary care hospital were systematically reviewed for morphology of MCA. Cases involving aneurysms and infarcts were excluded. Four shapes of MCA were recognized: straight, U, inverted U, and S-shaped. MCA was straight in 44% (254/578), U-shaped in 37% (215/578), S shaped in 15% (89/578) and inverted U-shaped in 3% (20/578) cases. In males, MCA was straight in 46% (166/360), U-shaped in 37% (134/360), S-shaped in 16% (58/360) and inverted U-shaped in 4% (14/360) cases. In females, MCA was straight in 42% cases (92/218), U-shaped in 37% (81/218), S-shaped in 17% (36/218) and inverted U-shaped in 4% (9/218). On comparing shape with various age groups using chi square test, U shaped (P≤0.001) and S-shaped (P=0.003) MCA were found to be statistically significant. The incidence of straight shape was higher in advanced age group (>60 years). Knowledge of MCA shape will be useful for clinicians and surgeons in successful endovascular recanalization. Also, this data would help surgeons during neurointerventional procedures.

Coil-Protected Technique for Liquid Embolization in Neurovascular Malformations

  • Keun Young Park;Jin Woo Kim;Byung Moon Kim;Dong Joon Kim;Joonho Chung;Chang Ki Jang;Jun-Hwee Kim
    • Korean Journal of Radiology
    • /
    • v.20 no.8
    • /
    • pp.1285-1292
    • /
    • 2019
  • Objective: To evaluate the safety and efficacy of the coil-protected technique for liquid embolization in neurovascular malformations. Materials and Methods: Twenty-two patients who underwent coil-protected liquid embolization for symptomatic cranial (n = 13) and spinal (n = 9) arteriovenous fistula (AVF) or arteriovenous malformations (AVMs) were identified. A total of 36 target feeder vessels were embolized with N-butyl cyanoacrylate and/or Onyx (Medtronic). This technique was used to promote delivery of a sufficient amount of liquid embolic agent into the target shunt or nidus in cases where tortuous feeding arteries preclude a microcatheter wedging techniqu and/or to prevent reflux of the liquid embolic agent in cases with a short safety margin. The procedure was considered technically successful if the target lesion was sufficiently filled with liquid embolic agent without unintentional reflux. Angiographic and clinical outcomes were retrospectively evaluated. Results: Technical success was achieved for all 36 target feeders. Post-embolization angiographies revealed complete occlusion in 16 patients and near-complete and partial occlusion in three patients each. There were no treatment-related complications. Of the six patients who showed near-complete or partial occlusion, five received additional treatments: two received stereotactic radiosurgery for cerebral AVM, two underwent surgical removal of cerebral AVM, and one underwent additional embolization by direct puncture for a mandibular AVM. Finally, all patients showed complete (n = 19) or near-complete (n = 3) occlusion of the target AVF or AVM on follow-up angiographies. The presenting neurological symptoms improved completely in 15 patients (68.2%) and partially in seven patients (31.8%). Conclusion: The coil-protected technique is a safe and effective method for liquid embolization, especially in patients with various neurovascular shunts or malformations who could not be successfully treated with conventional techniques.