• Title/Summary/Keyword: and turbidity

Search Result 1,695, Processing Time 0.029 seconds

Pre-treatment of River Water Using Biological Aerated Filtration (호기성 생물여과 공정을 이용한 하천수 전처리)

  • Choi, Dong-Ho;Choi, Hyung-Joo;Bae, Woo-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.3
    • /
    • pp.276-285
    • /
    • 2006
  • When polluted stream water was treated with biological aerated filter(BAF) in pilot plant, all operation with 90, 60, 45 and 30 min of EBCT at fixed $0.1m^3air/m^2min$ of aeration showed 80% or higher treatment efficiency of particle materials(SS, turbidity and Chl.-a) and 85% or higher efficiency of ammonia nitrogen removal. It was thought that, in case of BOD, biological stability may sufficiently be assured with BAF because grade III or IV inflow water was changed to grade I for outflow water. In case of $COD_{Mn}$, about 60% of removal efficiency was found. When the mechanism of the result was investigated, about 30% of COD materials was produced by algae clogged in the reactor. There was almost no biological decomposition because specific substrate utilization rate of algogenic organic materials were $0.0245mg{\cdot}COD_{Mn}/mg{\cdot}VSS{\cdot}day$, thus partial backwashing(washing the media in 1 m upper of the reactor once a day) was required. It is thought that elevation of removal rate about 10% of $COD_{Mn}$ and 5.5% of $BOD_5$ could be obtained with partial backwashing resulting in assurance of biologically more stable raw water and that saving backwashing water may be significant.

Optimization of mixing ratio in preparation of gluten-free rice udon through response surface methodology (반응 표면 분석법을 이용한 글루텐 프리 쌀 우동 제조 최적화)

  • Park, Se-Jin;Eun, Jong-Bang
    • Korean Journal of Food Science and Technology
    • /
    • v.53 no.6
    • /
    • pp.739-748
    • /
    • 2021
  • This study focuses on the use of rice in the production of gluten-free rice udon (GFU) through an optimized mixing ratio, using the Box-Behnken response surface methodology (RSM). Different additional levels of rice flour (A, 40-60 g), acetylated distarch adipate (B, 10-20 g), and trehalose (C, 0-3 g) were used as variables, while water absorption level, volume, cooking loss, solid yield, lightness, texture properties, proximate compositions of GFU and turbidity of cooking water were set as responses in the RSM design model. The optimum mixing ratio for the preparation of gluten-free rice udon was obtained for 60.00 g of rice flour, 18.81 g of acetylated distarch adipate without the addition of trehalose. The response values of the optimized samples were water absorption (60.94%), volume (34.94%), turbidity of the cooking water (0.37), cooking loss (4.77%), solid yield (1.55 g), lightness value (70.04), hardness (2.53 N), springiness (0.18), gumminess (10.45 N), chewiness (1.83 N), and cohesiveness (2.89). This study has shown that rice flour can replace wheat flour to manufacture udon at an optimized mixing ratio successfully derived by statistical estimation method.

Influence of Filtrate Quality by Variation of Operating Filter Number Based on Inflow (유입유량과 연계한 여과지 가동지수 변동 운영이 여과수 수질에 미치는 영향)

  • Kim, Jin-Keun;Lee, Jung-Tack
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.9
    • /
    • pp.817-824
    • /
    • 2009
  • To prevent turbidity breakthrough in a depth filter caused by hydraulic shock loads, influence of turbidity and particle number in filtrate by variation of operating filter number depending on inflow change was investigated. Inflow quantity at the S water treatment plant (WTP) was varied and ratio of maximum/minimum inflow quantity was 2.2, therefore filtration velocity was also subsequently changed. The S WTP changed operating filter number depending on inflow variation to minimize change of filtration velocity. Particle breakthrough was not severe when operation system was changed, out-of-operation and re-start of filter was repeated depending on inflow quantity. Slight particle breakthrough was noticed when re-start of filter was implemented at the filter that had a cumulative filtration run time of less than 10 h or more than 50 h. This can be attributed to the inadequate ripening and over accumulation of particles on media. Therefore, it is more efficient to choose a re-starting filter basin which has cumulative filtration run time more than 10 h or less than 50 h to reduce particle breakthrough. Filter number variation depending on inflow change was proven to be a method for improvement of unit filter run volume (UFRV).

Study on Precipitation of the Minerals in the Soil of Imha Reservoir Watershed (임하호 유역 토양의 광물학적 침전성 연구)

  • Kim, Yeonjeong;You, Samhwan;Jeong, Hyungjin;Baek, Seungcheol;Lee, Sungmin;Seo, Eulwon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.4
    • /
    • pp.13-18
    • /
    • 2010
  • The present study was undertaken to investigate the characteristic of suspended matter in soils of Imha-Dam area by turbidity. Soil sampling was conducted at 5 points of Yeongyang (Turbid area) and 2 points of Cheongsong (Clean area). Experimental analysis was conducted using those samples. The pH of water in the soils at turbid area was higher than that of clean area. X-ray diffraction analysis showed that every sample consists in mainly quartz, illite and feldspar before precipitation. After precipitation for 3 days, the content of quartz and feldspar was decreased and the content of illite was increased at turbid area. The soil of Sinheung (St. 6) at clean area was analyzed only illite. SEM-EDS analysis showed the much content of $SiO_2$ as to every sample before precipitation, but $K_2O$, MgO, $Al_2O_3$, CaO and $Fe2O_3$ with illite was increased after precipitation for 3 days as to every sample. Experimental results exhibited that the major mineral of turbid water was illite at turbid area and clean area.

Development of Vortex Scrubber Using Electrolyzed Water for the Removal Efficiency Improvement of Minute Particles and Odor (미세분진 및 냄새제거 효율향상을 위한 선회류식 세정전해 기술개발)

  • Kim, Nor-Jung;Lim, Seong-Il;Kim, Sun-Mi;Kim, Sun-Uk;Kim, Lae-Hyun;Kim, Sun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.3
    • /
    • pp.1-7
    • /
    • 2010
  • According to Indoor Air Quality(IAQ) management law for multi-use buildings, SEEONE CO., Ltd. made pilot and tested it to remove minute particle, odor, VOCs, etc. within the standards of IAQ. This pilot made by SEEONE CO., Ltd. is vortex scrubber washing electrolyzed water. As 30 minutes test result in multi-use building indoor place, minute particle(the smoke of a cigarette) was reduced $920{\mu}g/m^3{\rightarrow}112{\mu}g/m^3$, gaseous contaminants was reduced Formaldehyde (HCHO) 20ppm$\rightarrow$4ppm, Ammonia($NH_3$) 50ppm$\rightarrow$1ppm, Trimethylamine ($(CH_3CH_2)_3N$) 15ppm$\rightarrow$trace, Methylethylketone($CH_3COC_2H_5$) 25ppm$\rightarrow$trace, Acetic acid ($CH_3COOH$) 20ppm$\rightarrow$trace, Acetaldehyde($CH_3CHO$) 15ppm$\rightarrow$2ppm and Acetone($CH_3COCH_3$) 50ppm$\rightarrow$N.D. The pilot test result of the air filter using electroyzed water in vortex scrubber showed high removal efficiency. Because purified air maintain indoor humidity of approximately 40~60%, so users can feel pleasant. In E.coli, S.aureus sterilization test and CODcr, turbidity treatment test by electrolysis, germs was sterilized over 99.99% and CODcr and turbidity was decreased gradually. So water used for washing can be reused by electrolysis.

The Study on Manufacture of PACl(Polyaluminum Chloride) from Water Treatment Plant Sludges (정수장 슬러지(Alum Sludge)로부터 PACl(Polyaluminum Chloride) 응집제 제조에 관한 연구)

  • Kim, In-Bae;Lee, Sang-Bong;Kim, Dong-Youn;Kim, Boo-Gil
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.3
    • /
    • pp.441-451
    • /
    • 2000
  • Sludge produced from water treatment plants contains plenty of aluminum due to addition of coagulants, polyaluminum chloride(PACI) which has been widely used in most of water treatment plants. however. the whole of PACI is imported from other countries. In this research. the effective methods for recycling PACI from sludge of water treatment plants were developed and evaluated. Aluminum chloride hexahydrate($AlCl_3{\cdot}6H_2O$) was obtained by sparging HCl gas aluminum extracted from sludge using hydrochloric acid (HCI). This aluminum chloride hexahydrate was solidified by decomposition at $180^{\circ}C$. and dissolved in water to produce PACI. The optimum extraction rate was obtained at the condition of 10 minutes of reaction time. $105^{\circ}C$ of reaction temperature. 27.65%(W/W) of HCI concentration. The KS experiment proved that manufactured aluminum chloride hexahydrate was 98.7% degree and the recycled PACI coagulants agreed with the KS standard. The optimum temperature of decomposition was $180^{\circ}C$ and the basicity of the PACI was decided upon the extent of decomposition The compared experiments between purchased coagulant and manufactured coagulant presented that both coagulants had same performance for turbidity, DOC, $UV_{254}$ absorbance. and chlorophyll-a.

  • PDF

Optimization of Extraction Conditions from Omija(Schizandra chinensis Baillon) by Response Surface Methodology (반응표면 분석을 이용한 오미자 추출조건의 최적화)

  • Lee Won-Young;Choi Si-Young;Lee Bo-Su;Park Ju-Sek;Kim Mi-Ja;Oh Sang-Lyong
    • Food Science and Preservation
    • /
    • v.13 no.2
    • /
    • pp.252-258
    • /
    • 2006
  • To find the optimum extraction condition of dried omija, central composite experimental design having three independent variable (extraction temperature, extraction time and water ratio) with five levels was conducted for response surface analysis. The maximum of soluble solid was predicted to the extraction conditions of over 25 fold water ratio, $7{\sim}8hr$ and $75^{\circ}C$. Total acid, total phenol, reducing sugar and vitamin C were predicted to respectively 30 fold water ratio, 6 hr, $70^{\circ}C$, 30 fold water ratio, $6{\sim}7\;hrs,\;80^{\circ}C$ and 30 fold water ratio, $6{\sim}8\;hr,\;80^{\circ}C$, 25 fold water ratio, $5{\sim}6hr,\;80^{\circ}C$ extraction condition. Turbidity of extraction condition. Turbidity of extraction condition was 7 over 25 ford water ratio and over $60^{\circ}C$. From the superimposing results of response variables, the optimum extraction condition was predicted 25 folds water ratio, 6 hr and $65{\sim}70^{\circ}C$.

Quality Characteristics of Instant Nuroong-gi Prepared Using a Microwave (Microwave를 이용한 즉석 누룽지의 품질특성)

  • Lee, Hyun-Seok;Kwon, Ki-Hyun;Kim, Jong-Hoon;Cha, Hwan-Soo
    • Food Science and Preservation
    • /
    • v.16 no.5
    • /
    • pp.669-674
    • /
    • 2009
  • We prepared puffed instant Nuroong-gi samples using a microwave and investigated the physicochemical characteristics of the products. The quality of Nuroong-gi prepared using a microwave was compared with that of noodles prepared in a steam cooker and pressure cooker in terms of moisture content, color, water binding capacity ratio, viscosity, sedimented volume of insoluble solids, turbidity, and sensory evaluation. The moisture content of Nuroong-gi prepared in a microwave was similar to that of steam cooker and pressure cooker samples. The color (lightness) of steam cooker-prepared noodles was greater than that of noodles cooked using other modes. The water binding capacity ratio fell with increasing microwave cooking time. The viscosity of noodles prepared using a microwave was higher than that of pressure cooker samples and lower than that of steam cooker noodles. The sedimented volume of insoluble solids and turbidity increased with a rise in cooking temperature. Nuroong-gi prepared in a microwave scored higher in sensory evaluation tests than did steam cooker or pressure cooker samples. These results indicate that Nuroong-gi preparation using a microwave is very efficient.

Pretreatment Condition in the Full Scale Dissolved Air Flotation Process Using a DAF Pump (DAF 펌프를 이용한 실규모 용존공기부상 공정의 전처리 조건)

  • Lee, Chang-Han;An, Dae-Myung;Kim, Seong-Soo;Cho, Seok-Ho;Ahn, Kab-Hwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.1
    • /
    • pp.58-63
    • /
    • 2009
  • Dissolved air flotation (DAF) process is generally considered more effective than sedimentation process in raw water containing algae, humus materials, and low density particles. This study presents the treatment efficiencies by the coagulation and flocculation conditions at a drinking water treatment plant using a laboratory tester and the full scale DAF pump system. The full scale DAF pump system (F-DAF) in this study had a capacity of 5,000 $m^3$/d and a hydraulic surface loading of 10 m/hr. F-DAF in D drinking water treatment plant was continuously operated to determine the operational performance and pretreatment (mixing and coagulation) conditions. Results in the laboratory experiment showed that the optimum coagulant (PSO-M) doses required to 2.7~4.5 mL/$m^3$/NTU with raw water turbidity from 13.8 NTU to 56.3 NTU. F-DAF in the optimum coagulant dosage could be operated in effluent turbidity of 1 NTU or below for a month.

River Water Temperature Variations at Upstream of Daecheong Lake During Rainfall Events and Development of Prediction Models (대청호 상류 하천에서 강우시 하천 수온 변동 특성 및 예측 모형 개발)

  • Chung, Se-Woong;Oh, Jung-Kuk
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.1 s.162
    • /
    • pp.79-88
    • /
    • 2006
  • An accurate prediction of inflow water temperature is essentially required for real-time simulation and analysis of rainfall-induced turbidity 烈os in a reservoir. In this study, water temperature data were collected at every hour during the flood season of 2004 at the upstream of Daecheong Reservoir to justify its characteristics during rainfall event and model development. A significant drop of river water temperature by 5 to $10^{\circ}C$ was observed during rainfall events, and resulted in the development of density flow regimes in the reservoir by elevating the inflow density by 1.2 to 2.6 kg/$m^3$ Two types of statistical river water temperature models, a logistic model(DLG) and regression models(DMR-1, DMR-2, DMR-3) were developed using the field data. All models are shown to reasonably replicate the effect of rainfall events on the water temperature drop, but the regression models that include average daily air temperature, dew point temperature, and river flow as independent variables showed better predictive performance than DLG model that uses a logistic function to determine the air to water relation.