• Title/Summary/Keyword: and turbidity

Search Result 1,695, Processing Time 0.022 seconds

Improvement of tap water corrosivity by lime and carbon dioxide (액상소석회와 이산화탄소를 이용한 수돗물 부식성 개선)

  • Kim, Jinkeun;Lee, Junghoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.6
    • /
    • pp.725-733
    • /
    • 2014
  • 16 water treatment plants(WTPs) in Jeju province were investigated to evaluate the corrosivity of tap water. In addition, the impacts of lime and carbon dioxide on LI changes at ES WTP were analyzed. The average of LI in Jeju tap was -1.78 which was similar to that of in-land multi-regional WTPs. The recommended process to improve LI of ES WTP which has high corrosivity(i.e., LI = -2.61) was to combine lime and carbon dioxide with the dosages of 20 mg/L and 5 mg/L respectively to meet LI of -1.0 ~ 0. pH was confirmed to be a major water quality parameter that determined LI based on the correlation results among LI and water quality parameters. Precaution on turbidity increase by lime addition should given to minimize particle breakthrough in the distribution system. Turbidity increase can be controlled by the addition of lime prior to filters.

A Study on Low Concentrations of Organic Pollutants Removal using TiO2 (TiO2를 이용한 저농도 유기오염물질 제거에 관한 연구)

  • Lee, Yong-Hoon;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.1
    • /
    • pp.83-89
    • /
    • 2013
  • Microbiological treatment, chlorination, and ozonation are usually used for water treatment. However, there is weakness that these methods can't decompose and eliminate recalcitrant organic pollutants perfectly. It is possible to eliminate recalcitrant organic pollutants when photocatalysis of $TiO_2$ is used. In this study, the removal efficiencies of organic pollutants by using photocatalyst of $TiO_2$ in the slightly polluted golf club water hazard and a river were investigated. The amount of $TiO_2$ was divided into three categories of 1 g/L, 2 g/L and 4 g/L in order to investigate the adequate amount of $TiO_2$ and the removal efficiency. UV light was used as a light source for the reaction of photocatalyst. As a conclusion in this study, the efficiency of turbidity removal was increased in proportion to the amount of $TiO_2$ until 4 hours. After then the turbidity was gradually decreased. Finally, the optimum concentration of $TiO_2$ was 4 g/L. The efficiency of COD removal was increased in proportion to the amount of $TiO_2$ regardless of time.

A laboratory study on synthetic fiber filter for further treatment of turbid stormwater from construction sites

  • Yuan, Qingke;Kim, Youngchul
    • Membrane and Water Treatment
    • /
    • v.10 no.2
    • /
    • pp.105-112
    • /
    • 2019
  • On the purpose of conform the more stringent government regulation for turbid stormwater from construction sites, the feasibility and availability of synthetic fiber placing after the conventional protection barrier were tested in this study. Initially, comparative work on the filtering performance of fiber media and conventional gravel filter was carried out, 27% higher filtration capacity was obtained under the similar operational conditions. The filter efficiency was about 20 to 52% with a varying filter depth of 5 to 15cm, presuming at extreme storm flow conditions (800-1500 m/day of filtration rates). Fiber filter was found to have a similar filtration prosperity as grain media; namely, the separation efficiency is directly and inversely proportional to filter depth and rate, respectively. The effects of filter aid (polyaluminium chloride) on filter performance was also investigated, it greatly affected the turbidity reduction at the dosage of 2 mg/L. At the time of breakthrough, a simple filter washing was carried out, herein, the solid recovery achieved over than 88% and greatly determined by operational parameters. Based on the operational data, the empirical models aimed for predicting filtration efficiency were established, which can effectively determine the required filter depth and filtration area in field.

Study on Wastewater of Paper Mill for Coagulant Characteristics (제지폐수의 응집특성에 관한 연구)

  • Cho, Jun-Hyung;Jeong, Won-Gu;Kim, Joon-Hwan
    • Journal of Forest and Environmental Science
    • /
    • v.14 no.1
    • /
    • pp.101-111
    • /
    • 1998
  • Sedimentation characteristics SS, $BOD_5$ and removal efficiency of waste water in the tissue paper mill using milk carton were examined. Optimum dosage of coagulant, rapid mixing time and slow mixing time were determined by turbidity, SS and S-$BOD_5$ and then equation for treatment efficiency was suggested. For the coagulant, polyaluminium chloride(PAC) are compared with a little better efficiency compare to the aluminium sulfate.

  • PDF

Effect of Wastewater Treatment with Tannins from Peel of Astringent Persimmon Fruits (떫은감 껍질로부터 분리한 탄닌을 이용한 폐수처리 효과)

  • Cho Young-Je;Chun Sung-Sook
    • Food Science and Preservation
    • /
    • v.12 no.3
    • /
    • pp.299-304
    • /
    • 2005
  • The two major tannins were separated by Sephadex LH-20 and MCI-gel CHP-20 from peel of astringent persimmon fruits. Purified tannins were identified to (+)-catechin and (+)-gallocatechin by NMR, IR spectrum and FAB-mass spectrum. The removal rate of turbidity, T-N, T-P and CODcr in wastewater with lime and (+)-gallocatechin was higher than those of (+)-catechin because (+)-gallocatechin has more hydroxyl groups. As increasing concentration of tannins from peel of astringent persimmon fruits, the removal rate of turbidity, T-N, T-P and CODcr were increased. Synergistic activity by mixed tannins(catechin+gallocatechin) was also observed.

A Study on Indicator Bacteria for Water Quality Management of Urban Artificial Lakes (도심지역 인공호의 수질관리를 위한 지표세균에 관한 연구)

  • Chu, Duk-Sung;Kwon, Hyuk-Ku;Lee, Sang-Eun;Lee, Jang-Hoon
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.4
    • /
    • pp.299-305
    • /
    • 2007
  • Distribution of fecal pollution indicator bacteria and environmental parameter were investigated of urban artificial lakes. An average concentration of temperature, pH, SS, DO, $COD_{Mn}$, T-P, T-N, Turbidity, Chl-a were $21.5^{\circ}C$, 8.07, 116.70 mg/l, 8.66 mg/l, 2.24 mg/1, 0.52 mg/l, 1.71mg/l, 80.54 NTU, and 52.12 mg/l respectively. From the results of bivariate correlation analysis, fecal contamination indicator bacteria were found to be mutually correlated. And turbidity and suspended solid were correlated. From the results of principal component analysis, four factors were extracted. And four factors of variance explained up to 81.5 percentage. Factor 1 was pollution pattern by fecal contamination, factor 2 was physical pollution pattern by pollution source, factor 3 was natural pollution by precipitation, and factor 4 was artificial pollution pattern by organism.

Seasonal Variation and Storage Period of Rainwater Quality in Changwon (창원지역 빗물의 계절변화 및 저류시간에 따른 수질변화)

  • Han, Chi-Bok;Lee, Taek-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.5
    • /
    • pp.461-468
    • /
    • 2010
  • This study investigated variation of rainwater quality by seasonal and storage duration of rainwater in Changwon city. Seasonally, the pollutants concentration of rainwater were higher in spring and winter. In the case of rainwater and storage rainwater quality, pH of rainwater was 4.3, storage rainwaters were 6.0 and Turbidity increased about 8 times from 1.82 NTU to 14.61 NTU. The changes of storage water quality during the storage period, initial KMnO4 consumption rainwater was exceeded drinking water standard. Total solid in rainwater was detected as 116 mg/L, it tended to stable at around 70∼80mg/L after storage period for a 6day.

Preliminary Investigation of Membrane Modifying Effects of Ginseng Components (인삼성분 및 제제의 생체막 보호 효과에 대한 연구)

  • 한덕룡;김창종
    • Journal of Ginseng Research
    • /
    • v.11 no.1
    • /
    • pp.1-9
    • /
    • 1987
  • Prophylactic and curative behaviors of Panax ginseng components (95%, 50% ethanol ext., ginsenoside Re and Ginsana G 115) on the hepatomegaly, lipid peroxidation of the thioacetamide-intoxicated animals in vivo and in vitro were investigated. Ginsenoside Re and Ginsana G 115 significantly decreased in the lipid peroxide formation : the 95% ethanol extract and ginsenoside Re, in the zinc sulfate turbidity test. Besides these investigations, the preventive effect of ginseng components on the degranulation of mast calls in the guinea pig mesentery by compound 48/80 and venom toxin (Agkistrodon piscivourus) was also examined. All ginseng components subjected to this experiment were affected significantly at the different degrees.

  • PDF

A Study on the Removal of Algae by Coagulation and Sedimentation in the Rew Water of the Nakdong River (낙동강 원수내 조류의 응집 침전에 의한 제거에 관한 연구)

  • 이진희;김영주
    • Journal of Environmental Science International
    • /
    • v.10 no.2
    • /
    • pp.113-117
    • /
    • 2001
  • This study was conducted to investigate the effect of the prechlorination on algal removal by application of a varying amount of different coagulants, such as LAC, PAC, PACS following the process of coagulation and sedimentation of algae in the Nakdong River. The samples used as a source for the raw water of the Nakdong River were collected from the D Water Purification Plant in Taegu city. With the application of the process of prechlorination, the removal rate of the algae was increased from 10~25% for Synedra spp., 20~35% for diatoms and 4~17% for turbidity. Generally, the removal rate of the algae was increased with the increase of the concentration of the coagulants. The PAC and PACS showed 5% higher removal rate for turbidity as compared to the LAS. On the hand, LAS showed 12% higher removal rate for Synedra spp. as compared to the PAC and PACS. The variations in the removal rate of diatoms with the change of coagulant were not significant. In conclusion, the application of LAS, polymeric coagulant and chlorination for at least 20 minutes could be considered as a reliable treatment process for the removal of source water containing a variety of algae.

  • PDF

Influence of mixed liquor suspended solids on the removal efficiency of a hybrid membrane bioreactor

  • Palmarin, Matthew J.;Young, Stephanie
    • Membrane and Water Treatment
    • /
    • v.7 no.1
    • /
    • pp.11-22
    • /
    • 2016
  • The characterization of treatment performance with respect to mixed liquor suspended solids (MLSS) concentration enables greater control over system performance and contaminant removal efficiency. Hybrid membrane bioreactors (HMBRs) have yet to be well characterized in this regard, particularly in the context of greywater treatment. The aim of this study, therefore, was to determine the optimal MLSS concentration for a decentralized HMBR greywater reclamation system under typical loading conditions. Treatment performance was measured at MLSS concentrations ranging from 1000 to 4000 mg/L. The treated effluent was characterized in terms of biochemical oxygen demand ($BOD_5$), chemical oxygen demand (COD), turbidity, ammonia ($NH_3$), total phosphorus (TP), total kjeldahl nitrogen (TKN), and total nitrogen (TN). An MLSS concentration ranging from 3000 to 4000 mg/L yielded optimal results, with $BOD_5$, COD, turbidity, $NH_3$, TP, TKN, and TN removals reaching 99.2%, 97.8%, 99.8%, 99.9%, 97.9%, 95.1%, and 44.8%, respectively. The corresponding food-to-microorganism ratio during these trials was approximately 0.23 to 0.28. Operation at an MLSS concentration of 1000 mg/L resulted in an irrecoverable loss of floc, and contaminant residuals exceeded typical guideline values for reuse in non-potable water applications. Therefore, it is suggested that operation at or below this threshold be avoided.