• Title/Summary/Keyword: and turbidity

Search Result 1,695, Processing Time 0.033 seconds

Operation evaluation of DAF pilot plant for water treatment process in Hoedong Reservoir (회동수원지의 정수처리 공정을 위한 DAF pilot plant 운영 성능평가)

  • Maeng, Minsoo;Shahi, Nirmal Kumar;Kim, Donghyeun;Shin, Gwyam;Dockko, Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.6
    • /
    • pp.463-471
    • /
    • 2020
  • A 1,000 ㎥/d DAF(dissolved air flotation) pilot plant was installed to evaluate the performance of the floating process using the Nakdong River. Efficiency of various DAF operations under different conditions, such as hydraulic loading rate, coagulant concentration was evaluated in the current research. The operation conditions were evaluated, based on the removal or turbidity, TOC(total organic carbon), THMFP(trihalomethane formation potential), Mn(manganese), and Al(aluminum). Also, particle size analysis of treated water by DAF was performed to examine the characteristics of particles existing in the treated water. The turbidity removal was higher than 90%, and it could be operated at 0.5 NTU or less, which is suitable for the drinking water quality standard. Turbidity, TOC, and THMFP resulted in stable water quality when replacing the coagulant from alum to PAC(poly aluminum chloride). A 100% removal of Chl-a was recorded during the summer period of the DAF operations. Mn removal was not as effective as where the removal did not satisfy the water quality standards for the majority of the operation period. Hydraulic loading of 10 m/h, and coagulant concentrations of 40 mg/L was determined to be the optimal operating conditions for turbidity and TOC removal. When the coagulant concentration increases, the Al concentration of the DAF treated water also increases, so coagulant injection control is required according to the raw water quality. Particle size distribution results indicated that particles larger than 25 ㎛ showed higher removal rates than smaller particles. The total particel count in the treated water was 2,214.7 counts/ml under the operation conditions of 10 m/h of hydraulic loading rate and coagulant concentrations of 60 mg/L.

Comparison of Settleable and Non-settleable Suspended Sediment in Streams and Lakes (강우시 하천과 호수에서 침강성 부유토사와 비침강성 부유토사의 비교)

  • Eum, Jaesung;Jung, Sungmin;Choi, Yongsoon;Lee, Hyungjin;Choi, Joongdae;Kim, Bomchul
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.2
    • /
    • pp.232-237
    • /
    • 2012
  • Total suspended solids (TSS), settleable suspended solids (SSS) and nonsettleable suspended solids (NSSS) were compared in streams and lakes during rain events. Samples were collected in Lake Soyang and nine agricultural streams during storm events over two years. To measure NSSS, samples were settled in 1 L cylinders for one hour and then 50% of the total sample volume was taken from the center of the cylinder. The SSS/TSS ratio in streams (0.50) was higher than in Lake Soyang (0.20). The ratio of TSS to turbidity decreased from 1.21 in the inflowing river to 0.69 in the reservoir outlet. Turbidity and NSSS showed higher correlation ($r^2$=0.82) compared with the correlation between turbidity and TSS ($r^2$=0.66). Median particle size decreased from $11.4\;{\mu}m$ in the inflowing river to $4.2\;{\mu}m$ in the lake outlet. The results indicate that only fine particles of less than $5{\sim}10\;{\mu}m$ can be transported downstream of the lake. Because fast-flowing water in streams includes not only fine particles but also coarse particles, an overestimation of suspended sediment concentration results if only TSS is measured. Consequently, TSS and NSSS should be measured separately to evaluate the effect of suspend sediment loadings of turbid streams on aquatic habitat during the monsoon season.

Effect of Hydroelectric Power Plant Discharge on the Turbidity Distribution in Dae-Cheong Dam Reservoir (발전방류구 위치변화에 따른 저수지내 탁수변화 -대청댐을 대상으로-)

  • Seo, Se-Deok;Lee, Jae-Yil;Ha, Sung-Ryong
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.2
    • /
    • pp.227-234
    • /
    • 2011
  • In the study, CE-QUAL-W2 was used and its examination and correction were conducted targeting 2001 and 2003 when the condition of rainfall was contradicted. Using the proved model in 2003, a scenario was implemented with management of locations for dewatering outlets and actual data for dam management in 1987 when inflow and outflow level were almost same. In case of the scenario which the location of dewatering outlets was 5m higher than usual location, exclusion efficiency for turbid water inflow at the beginning of precipitation was good. In case of the scenario which the location of dewatering outlets was 10m lower than usual location, exclusion efficiency for excluding turbid water remained in a reservoir after the end of precipitation. However, the scenario applying dam management data in 1987, exclusion efficiency was relatively low. In the scenario, power-generating water release spot at EL.57m for first four days after the beginning of precipitation, EL.52m for 5th to 8th and EL.42m from 9th days. An analysis of the scenario reveals that both excessive days exceeded 30 NTU and average turbidity levels were decreased comparing before and after the alteration on outlets. The average turbidity levels were decreased by minimum of 55% to maximum of 70% and 30NTU exceeding days were decreased by 45 days at maximum. Also, since it could exclude most of turbid water in a reservoir before the destatifcation, the risk for turbid water evenly distributed in a reservoir along with turn-over could be decreased as well.

The Effect of Antibrowning Agents on Enzymatic Reaction in Apple Concentrate (사과농축액에 대한 갈변억제제 처리효과)

  • Kim, Hyeon-Wee;Bae, Soo-Kyung
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.3
    • /
    • pp.454-458
    • /
    • 2002
  • The effect of antibrowning agents such as PVPP (polyvinylpolypyrrolidone), bentonite, gelatin, celite 545, tannic acid and sodium sulfite in apple concentrate was investigated for the control of enzymatic browning by comparing physicochemical properties (pH, color, turbidity), polyphenoloxidase activity and contents of polyphenol compounds. In color value, apple concentrate containing PVPP showed higher L value (lightness) than control and other antibrowning agents. The turbidity (absorbance at 660 nm) of apple concentrate added PVPP, gelatin celite 545, tannic acid and sodim sulfite were 0.003, 0.038, 0.018 and 0.022, respectively. PVPP was regarded to remove suspended solids effectively. Polyphenoloxidase activity and polyphenolics(catechol, catechin, chlorogenic acid, epicatechin) content of apple concentrate used PVPP significantly reduced. Therefore PVPP was proved to be effective for enzymatic antibrowning agent considering to color, turbidity, polyphenoloxidase activity and polyphenol compounds in apple concentrate.

Performance Analysis of Sonar System Applicable to Underwater Construction Sites with High Turbidity (탁도가 높은 수중작업현장에 사용 가능한 소나시스템의 성능 분석)

  • Shin, Changjoo;Jang, In-Sung;Kim, Kihun;Choi, Hyun-Tack;Lee, Seung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4507-4513
    • /
    • 2013
  • The developing unmanned underwater equipment can be used for underwater construction site such as underwater leveling works. If a optical camera is applied to the unmanned underwater equipment, recognition in underwater can be gone to low due to high turbidity in working field. To overcome this problem, a sonar will be installed to the unmanned underwater equipment. In this study, the resolution of the sonar and the quality test of the sonar image under high turbidity environment were conducted. And the method to indicate the boundary of the underwater construction site was proposed. By these results, the basic performance of the sonar was evaluated.

Studies on Heat Sensitivity of Egg Albumen I. Effects of Heating Time and Temperature, pH and NaCl Concentration on Heat Sensitivity of Egg Albumen (난백 의 열감수성 에 관한 연구 I. 가열온도와 시간, pH 및 NaCl농도가 난백의 열감수성에 미치는 영향)

  • 유익종
    • Korean Journal of Poultry Science
    • /
    • v.15 no.1
    • /
    • pp.39-44
    • /
    • 1988
  • This study was undertaken to find out the effect of heating time and temperature, pH and NaCl concentration on heat sensitivity of egg albumen during heat treatment. Sharp increase of the turbidity and rapid decrease of the foaming power were observed when egg albumen was heated at above $60^{\circ}C$. Egg albumen became opaque when it was heated at $60^{\circ}C$ for above 13 minutes or at $65^{\circ}C$ for above 5 minutes. The turbidity was markedly increased at below pH 7 and the foaming power was largely decreased at around pH 4.0 by the heat treatment ($60^{\circ}C$, 5 min). The foam stability was slightly decreased at alkaline pH range by the heat treatment (60t, 5 min). The addition of NaCl up to 0.3M decreased the turbidity. There was no effect of NaCl addition on the foaming power, but the foam stability was decreased by the addition of NaCl at above 0.2M before and after the heat treatment ($60^{\circ}C$, 5 min).

  • PDF

New Technologies for Enhancing Particles Separation Efficiency in Coagulation and Filtration (입자분리효율을 높이기 위한 새로운 기술)

  • Kunio, Ebie;Jang, Il-Hun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.2
    • /
    • pp.254-269
    • /
    • 2004
  • Polysilicato-iron coagulant (PSI) is receiving attention in Japan as a substitute for aluminum-based coagulants. In the first part of this article, coagulation, sedimentation and filtration experiments were carried out using kaolin clay particles as the turbidizing material and four types of PSI with various molar ratios of polysilicic acid to ferric chloride (Si/Fe ratio). Results demonstrate that use of a PSI with a high Si/Fe ratio can cause a more dramatic decrease in treated water turbidity but a higher suction time ratio (STR) than when PACl is used. However, optimization by increasing the rapid agitation strength GR is found to greatly improve the STR. In addition, the series of filtration experiments verified that optimization of GR is greatly effective in controlling rapid increases in filter head loss, and also formation of a thin aging layer in the upper part of the filter bed by slow-start filtration is effective in improving filtered water turbidity over the entire filtration process. The second part of this article describes two innovative filtration techniques to increase the particle separation efficiency; (1) coagulant-coated filter medium by enhancing the electrical potential of the surface of the filter medium, and (2) coagulant dosing in influent by controlling the electrical potential of particles entering the filter layer. From the results of the various filtration experiments using a pilot plant, these two techniques were found to be very effective to reduce the effluent water turbidity from the start to the end of a filter run. Moreover, in the filtration experiments using these two methods simultaneously, higher removal efficiency of approximately 3-log (99.7%) was realized, resulting that the finished water turbidity was accordingly reduced to 0.004mg/L.

Turbidity Meter Calibrations Based on Grain Size Distribution of Trapped Suspended Material (포획된 부유물질의 입도분포를 고려한 탁도계 검교정)

  • 조홍연;김백운
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.15 no.1
    • /
    • pp.33-38
    • /
    • 2003
  • Turbidity meter calibrations were conducted using bottom sediment and suspended material collected with a vertical array of sediment traps at the coastal water off Gaduk Island. Compared to the bottom sediment comprising sand fraction of approximately 6%, trapped suspended material was composed entirely of silt and clay fractions and showed a tendency to get finer as elevation from the sea-bed increases. Slope parameter of linear regression due to bottom sediment was of minimum value and values of those due to suspended material increased gradually as the height of sediment trap increases (i.e., sediment size decreases). This result shows that turbidity meter calibration using bottom sediment can cause an overestimation error in the calculation of suspended sediment concentration and that the error can reach up to 25% in case of this study. Therefore, it is suggested that the use of a corrected calibration curve based on grain size distribution of suspended material instead of bottom sediment may reduce the measurement error of suspended sediment concentration.

Effect of Coagulants and Separation Methods on Algal Removal in Water Treatment Process (정수처리에서 응집제 종류와 분리공정이 조류 제거에 미치는 영향)

  • Park, Hung-Suck;Lee, Sang-Yoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.2
    • /
    • pp.279-289
    • /
    • 2000
  • The objective of this study was to investigate the effect of coagulants and solid-liquid separation methods on algal removal in water treatment processes. Thus characterization of raw water quality in terms of turbidity. UV-254, $KMnO_4$ consumption, chlorophyll-a and correlation analysis of these parameters were conducted. In addition, the effect of commercial Al-based coagulants(Alum. PAC and PACS) on algal removal was studied by turbidity and organic removal, algal species removal, characteristic of pH drop and alkalinity consumption using laboratory jar tests. Organic components including UV-254, $KMnO_4$ consumption, chlorophyll-a in case of algal bloom were highly correlated with turbidity and the correlation coefficients of UV-254, $KMnO_4$ consumption, chlorophyll-a with turbidity were 0.775, 0674 and 0.623, respectively. In coagulation and sedimentation, the Al-based coagulants showed similar efficiency of organic and turbidity removal in low organic($KMnO_4$ consumption below 15mg/l) and low turbidity(below 30NTU). However, PAC and PACS showed better algal removal than alum in high organic concentration($KMnO_4$ consumption above 20mg/l) and high turbidity(above 100NTU) raw water conditions generated by high algal growth, which is considered to be due to the floc settleability. In comparison of sedimentation and flotation after chemical coagulation and flocculation, the removal efficiency of organic and turbidity were higher in case of alum dose with flotation than with sedimentation, while those were better in case or PAC and PACS with sedimentation than with flotation. Thus, Alum with flotation and PAC and PACS with sedimentation is recommended for efficient algal removal. The dominant phytoplankton in raw water were Microcystic and pediastrum simplex and the removal efficiency of algae with sedimentation using alum. PAC and PACS were 27%, 45% and 22% respectively, while those with DAF showed 100% removal of phytoplankton and zooplankton.

  • PDF

Temperature analysis of a long-span suspension bridge based on a time-varying solar radiation model

  • Xia, Qi;Liu, Senlin;Zhang, Jian
    • Smart Structures and Systems
    • /
    • v.25 no.1
    • /
    • pp.23-35
    • /
    • 2020
  • It is important to take into account the thermal behavior in assessing the structural condition of bridges. An effective method of studying the temperature effect of long-span bridges is numerical simulation based on the solar radiation models. This study aims to develop a time-varying solar radiation model which can consider the real-time weather changes, such as a cloud cover. A statistical analysis of the long-term monitoring data is first performed, especially on the temperature data between the south and north anchors of the bridge, to confirm that temperature difference can be used to describe real-time weather changes. Second, a defect in the traditional solar radiation model is detected in the temperature field simulation, whereby the value of the turbidity coefficient tu is subjective and cannot be used to describe the weather changes in real-time. Therefore, a new solar radiation model with modified turbidity coefficient γ is first established on the temperature difference between the south and north anchors. Third, the temperature data of several days are selected for model validation, with the results showing that the simulated temperature distribution is in good agreement with the measured temperature, while the calculated results by the traditional model had minor errors because the turbidity coefficient tu is uncertainty. In addition, the vertical and transverse temperature gradient of a typical cross-section and the temperature distribution of the tower are also studied.