• 제목/요약/키워드: and electrical stability

검색결과 4,280건 처리시간 0.028초

Polyaniline계 전도성 고분자의 열안정 특성 (Thermal stability of polyaniline based conductive polymer blend)

  • 백운석;윤호규;서광석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 추계학술대회 논문집
    • /
    • pp.215-218
    • /
    • 1998
  • The thermal stability of polyaniline-camphorsulfonic acid(PANI-CSA) film was studied as a function of temperature and time. A decrease in electrical conductivity of PANI-CSA film occurred when PANI-CSA film is subjected to temperature above 60$^{\circ}C$. From the result of thermogravimetry (TG), it was thought that the deterioration in electrical conductivity of PANI-CSA film was due to evaporation of water and residual solvent.

  • PDF

An analysis of robust stability for time delay systems based on lyapunov type operator equation

  • E. Shimemura;K. Uchida;A. Kojima
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1989년도 한국자동제어학술회의논문집; Seoul, Korea; 27-28 Oct. 1989
    • /
    • pp.901-906
    • /
    • 1989
  • A robust stability problem for time delay systems is discussed by using a property of Lyapunov type operator equation. We propose a method to check the robust stability against the parameter perturbations occurring in both lumped parameter part and distributed delay element.

  • PDF

On the Stability of Critical Point for Positive Systems and Its Applications to Biological Systems

  • Lee, Joo-Won;Jo, Nam Hoon;Shim, Hyungbo;Son, Young Ik
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1530-1541
    • /
    • 2013
  • The coexistence and extinction of species are important concepts for biological systems and can be distinguished by an investigation of stability. When determining local stability of nonlinear systems, Lyapunov indirect method based on the Jacobian linearization has been widely employed due to its simplicity. Despite such popularity, it is not applicable to singular systems whose Jacobian has at least one eigenvalue that is equal to zero. In such singular cases, an appropriate Lyapunov function should be sought to determine the stability of systems, which is rather difficult and quite involved. In this paper, we seek for a simple criterion to determine stability of the equilibrium that is located at the boundary of the positive orthant, when one of eigenvalues of the Jacobian is zero. The goal of the paper is to present a generalized condition for the equilibrium to attract all trajectories that starting from initial condition in the positive orthant and near the equilibrium. Unlike the Lyapunov direct method, the proposed method requires just a simple algebraic computation for checking the stability of the critical point. Our approach is applied to various biological systems to show the effectiveness of the proposed method.

New Stability Criterion and Pole Assignment for Switched Linear Systems

  • Yeom Dong-Hae;Im Ki-Hong;Choi Jin-Young
    • International Journal of Control, Automation, and Systems
    • /
    • 제3권4호
    • /
    • pp.580-590
    • /
    • 2005
  • In this paper, we propose a new stability criterion and a controller design method for switched linear systems. The proposed stability criterion is applicable to each subsystem independently without the need to consider the overall system. The controller can be easily designed through geometric relations between eigenvalues of each subsystem matrix. The proposed methods provide a systematic and simple pole assignment approach for switched linear systems. Illustrative examples are given.

Voltage Stability Prediction on Power System Network via Enhanced Hybrid Particle Swarm Artificial Neural Network

  • Lim, Zi-Jie;Mustafa, Mohd Wazir;Jamian, Jasrul Jamani
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.877-887
    • /
    • 2015
  • Rapid development of cities with constant increasing load and deregulation in electricity market had forced the transmission lines to operate near their threshold capacity and can easily lead to voltage instability and caused system breakdown. To prevent such catastrophe from happening, accurate readings of voltage stability condition is required so that preventive equipment and operators can execute security procedures to restore system condition to normal. This paper introduced Enhanced Hybrid Particle Swarm Optimization algorithm to estimate the voltage stability condition which utilized Fast Voltage Stability Index (FVSI) to indicate how far or close is the power system network to the collapse point when the reactive load in the system increases because reactive load gives the highest impact to the stability of the system as it varies. Particle Swarm Optimization (PSO) had been combined with the ANN to form the Enhanced Hybrid PSO-ANN (EHPSO-ANN) algorithm that worked accurately as a prediction algorithm. The proposed algorithm reduced serious local minima convergence of ANN but also maintaining the fast convergence speed of PSO. The results show that the hybrid algorithm has greater prediction accuracy than those comparing algorithms. High generalization ability was found in the proposed algorithm.

댐핑 영향을 반영하는 Lyapunov 함수 그룹의 유도 및 응용 (Derivation of a Group of Lyapunov Functions reflecting Damping Effects and its Application)

  • 문영현;최병곤;노태훈;이태식;이윤섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.195-198
    • /
    • 1995
  • Most of the theorems of nonlinear stability is based on the Lyapunov stability theory. The Lyapunov function method is the most well-known and provides precise and rigorous theoretical backgrounds. However, tile conventional approach to direct stability analysis has been performed without taking account of damping effects. For accurate stability analysis of nonlinear systems, it is required to consider the damping effects. This paper presents a new method to derive a group of Lyapunov functions to reflect the damping effects by considering the integral relationships of the system governing equations. This method tan be utilized as a powerful tool to determine the region of attraction.

  • PDF

손실재분배와 정적전압의존형 부하모델을 고려한 전압안정도 해석 (Voltage Stability Analysis considering Static Voltage Dependent Load Model and Loss Redistribution)

  • 김근성;채명석;신중린;임한석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.215-217
    • /
    • 1997
  • In many conventional analysis of voltage stability the effect of load characteristics is ignored. But in the real system the load is composed of various components. Therefore if the load composition could be modeled then it will plays an important role in the analysis of static voltage stability. And also, if the system loss generally imposed to slack bus in the conventional load flow calculation is redistributed to each generator the accuracy of static voltage stability analysis can be improved. This paper presents the effect of load composition in the analysis of system stability as well the loss redistribution algorithm. And this paper will compare the result of conventional method with that of the proposed method.

  • PDF

HVDC 추가도입에 대한 제주도 계통의 정태 안정도 분석 (Stability Analysis of Jeiu Power System added with HVDC)

  • 신성수;김도형;김재언
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.491-493
    • /
    • 2008
  • This paper presents results of comparing CSC HVDC with VSC HVDC on the stability in case of connecting Haenam to Jeju electrical power system, the steady-state stability in the case of Jeju electrical power system with CSC HYDC or VSC HVDC, is validated through PV curve, QV curve of Jeju electrical power system. And in the case of CSC HVDC, it is considered that synchronous condenser is connected or not. The results are compared each other. PSS/E simulation tool is used for the steady-state stability analysis.

  • PDF

Extreme Learning Machine Approach for Real Time Voltage Stability Monitoring in a Smart Grid System using Synchronized Phasor Measurements

  • Duraipandy, P.;Devaraj, D.
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권6호
    • /
    • pp.1527-1534
    • /
    • 2016
  • Online voltage stability monitoring using real-time measurements is one of the most important tasks in a smart grid system to maintain the grid stability. Loading margin is a good indicator for assessing the voltage stability level. This paper presents an Extreme Learning Machine (ELM) approach for estimation of voltage stability level under credible contingencies using real-time measurements from Phasor Measurement Units (PMUs). PMUs enable a much higher data sampling rate and provide synchronized measurements of real-time phasors of voltages and currents. Depth First (DF) algorithm is used for optimally placing the PMUs. To make the ELM approach applicable for a large scale power system problem, Mutual information (MI)-based feature selection is proposed to achieve the dimensionality reduction. MI-based feature selection reduces the number of network input features which reduces the network training time and improves the generalization capability. Voltage magnitudes and phase angles received from PMUs are fed as inputs to the ELM model. IEEE 30-bus test system is considered for demonstrating the effectiveness of the proposed methodology for estimating the voltage stability level under various loading conditions considering single line contingencies. Simulation results validate the suitability of the technique for fast and accurate online voltage stability assessment using PMU data.

A study on charging and electrical stability characteristics with no-insulation and metal insulation in form of racetrack type coils

  • Quach, Huu Luong;Kim, Ho Min
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권3호
    • /
    • pp.13-19
    • /
    • 2020
  • This study presents the experiment and simulation results on the magnetic field response and electrical stability behaviors of no-insulation (NI) and metal insulation with stainless steel tape (MI-SS) which wound in form of racetrack type coils. First of all, the structural design of the racetrack type bobbin was shown along with its parameters. Then, the current-voltage tests were carried out to measure the critical current of both test coils. Also, the sudden discharging and charging tests were performed in the steady state to estimate the decay field time and magnetic field response, respectively. Finally, the overcurrent tests were conducted in the transient state to investigate the electrical stability of these test coils. Based on the experimental results, the contact surface resistances were calculated and applied to the field coils (FCs) of 10-MW-class second generation high temperature superconducting generator (2G HTSG) used in wind offshore environment. The charging delay time and electrical stability for NI and MI-SS HTS FCs of 10-MW-class 2G HTSG are analyzed by the equivalent circuit model and the key parameters which were obtained from the electromagnetic finite element analysis results.