• Title/Summary/Keyword: and VP9

Search Result 211, Processing Time 0.026 seconds

Assessment of Quality Changes in Mackerel Scomber japonicus During Refrigerated Storage: Development of a Freshness Indicator (냉장 저장 중 고등어(Scomber japonicus)의 선도 지표 개발을 위한 품질 특성 평가)

  • Park, Sun-Hee;Kim, Min-Ju;Kim, Go-Un;Choi, Hyeun-Deok;Park, So-Yeong;Kim, Min-Ji;Kim, Koth-Bong-Woo-Ri;Kim, Young-Min;Nam, Taek-Jeong;Hong, Chang-Wook;Choi, Jae-Hyuk;Jang, Myung-Kee;Lee, Ju-Woon;Ahn, Dong-Hyun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.49 no.6
    • /
    • pp.731-736
    • /
    • 2016
  • No freshness indicator for fish has yet been established. Thus, we investigated changes over time in mackerel quality in an effort to development useful indicators. Fresh whole mackerel Scomber japonicus were stored at $4^{\circ}C$ immediately after capture and quality changes were evaluated every 3 days for a total of 15 days. Whole fish were divided into ventral parts (VPs) and dorsal parts (DPs); we measured the trimethylamine (TMA) and volatile basic nitrogen (VBN) levels, pH values, and color values in/of these parts. The TMA and VBN levels tended to increase during storage and the TMA changes in VPs were higher than those in DPs. In particular, the VP TMA content attained a maximum of 3.68 mg/100 g at 6 days, and the VBN content attained a maximum of 20.88 mg/100 g at 9 days, suggestive of initial fish spoilage. The pH ranged from 5.99-6.17 over the first 3 days and from 6.17-6.38 from days 6-15. Surface color changes on VPs and DPs were explored. Significant decreases in both VP lightness and yellowness were evident after 3 days. The data suggest that both TMA level and lightness of the color are valuable indicators of freshness in the initial stage of mackerel retail.

Cycle-Consistent Generative Adversarial Network: Effect on Radiation Dose Reduction and Image Quality Improvement in Ultralow-Dose CT for Evaluation of Pulmonary Tuberculosis

  • Chenggong Yan;Jie Lin;Haixia Li;Jun Xu;Tianjing Zhang;Hao Chen;Henry C. Woodruff;Guangyao Wu;Siqi Zhang;Yikai Xu;Philippe Lambin
    • Korean Journal of Radiology
    • /
    • v.22 no.6
    • /
    • pp.983-993
    • /
    • 2021
  • Objective: To investigate the image quality of ultralow-dose CT (ULDCT) of the chest reconstructed using a cycle-consistent generative adversarial network (CycleGAN)-based deep learning method in the evaluation of pulmonary tuberculosis. Materials and Methods: Between June 2019 and November 2019, 103 patients (mean age, 40.8 ± 13.6 years; 61 men and 42 women) with pulmonary tuberculosis were prospectively enrolled to undergo standard-dose CT (120 kVp with automated exposure control), followed immediately by ULDCT (80 kVp and 10 mAs). The images of the two successive scans were used to train the CycleGAN framework for image-to-image translation. The denoising efficacy of the CycleGAN algorithm was compared with that of hybrid and model-based iterative reconstruction. Repeated-measures analysis of variance and Wilcoxon signed-rank test were performed to compare the objective measurements and the subjective image quality scores, respectively. Results: With the optimized CycleGAN denoising model, using the ULDCT images as input, the peak signal-to-noise ratio and structural similarity index improved by 2.0 dB and 0.21, respectively. The CycleGAN-generated denoised ULDCT images typically provided satisfactory image quality for optimal visibility of anatomic structures and pathological findings, with a lower level of image noise (mean ± standard deviation [SD], 19.5 ± 3.0 Hounsfield unit [HU]) than that of the hybrid (66.3 ± 10.5 HU, p < 0.001) and a similar noise level to model-based iterative reconstruction (19.6 ± 2.6 HU, p > 0.908). The CycleGAN-generated images showed the highest contrast-to-noise ratios for the pulmonary lesions, followed by the model-based and hybrid iterative reconstruction. The mean effective radiation dose of ULDCT was 0.12 mSv with a mean 93.9% reduction compared to standard-dose CT. Conclusion: The optimized CycleGAN technique may allow the synthesis of diagnostically acceptable images from ULDCT of the chest for the evaluation of pulmonary tuberculosis.

The Usefulness of Al Face Block Fabrication for Reducing Exposure Dose of Thyroid Glands in Mammography (유방촬영 시 갑상샘의 피폭선량 경감을 위한 Al Face Block 제작 및 유용성에 관한 연구)

  • Hong, Eun-Ae;Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.11-17
    • /
    • 2013
  • Currently, there are many studies being conducted around the world to reduce exposure dose to radiation for patients to receive medical treatments in a safe environment. We developed and fabricated of this shield that the patients are protected from the radiation and are need of safety control during breast imaging. In this study, for breast imaging, GE Senography 2000D were used and set at SID 65cm, 28kVp, and 63mAs. The measuring instrument was Fluke's Victoreen 6000-529. And we performed Face Block on with 30 patients. The chamber on the actual thyroid glands to take CC and MLO and measure the dosage before and after wearing the Face Block. For the results, after wearing the Face Block, exposure was decreased by 53.8%-100% and 65.8% in average in CC View and by 50%-100% and 60.7% in average in MLO View. The development of the Face Block that practically decreased the exposure dose of thyroid glands, crystalline eyes during breast imaging and reduced the patients' anxiety during breast imaging. The Face Block is expected to improve patients' satisfaction and contribute to reducing patients' exposure dose, but more efforts should be made to reduce exposure dose to medical radiation.

Effect of Prenatal Antibiotic Exposure on Neonatal Outcomes of Preterm Infants

  • Kim, Hyunjoo;Choe, Young June;Cho, Hannah;Heo, Ju Sun
    • Pediatric Infection and Vaccine
    • /
    • v.28 no.3
    • /
    • pp.149-159
    • /
    • 2021
  • Purpose: Antibiotic exposure during pregnancy may affect the fetus and newborn in many ways. This study investigated the impact of prenatal antibiotic exposure duration on neonatal outcomes in very preterm (VP) or very low birth weight (VLBW) infants. Methods: From September 2015 to December 2020, preterm infants with gestational age less than 32 weeks or with a BW less than 1,500 g who were admitted to the neonatal intensive care unit, and their mothers were enrolled. Prenatal antibiotic exposure was defined as antibiotics received by mothers before delivery, and the patients were categorized into the non-antibiotic group, short-duration (SD; ≤7 days) group, or long-duration (LD; >7 days) groups. Results: A total of 93 of 145 infants were exposed to prenatal antibiotics, among which 35 (37.6%) were in the SD group and 58 (62.4%) were in the LD group. Infants in the LD group had a significantly higher birth weight-for-gestational-age (BW/GA) Z-score than those in the non-antibiotic group, even after the adjustment for confounding factors (beta, 0.258; standard error, 0.149; P<0.001). Multivariate logistic regression analysis showed that prolonged prenatal antibiotic exposure was independently associated with death (adjusted odds ratio [aOR], 8.926; 95% confidence interval [CI], 1.482-53.775) and composite outcomes of death, necrotizing enterocolitis (NEC), and late-onset sepsis (LOS) (aOR, 2.375; 95% CI, 1.027-5.492). Conclusions: Prolonged prenatal antibiotic exposure could increase the BW/GA Z-score and the risk of death and composite outcomes of death, NEC, and LOS in VP or VLBW infants.

Distribution of Rotavirus G Serotypes in ChungJu Area (충주 지역 설사 환아의 Rotavirus G Serotype 분포에 관한 연구)

  • Sim, Jae-Geon;Kwon, Jae-Bong;Kang, Shien-Young
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.3 no.1
    • /
    • pp.41-46
    • /
    • 2000
  • Purpose: It is important to have the epidemiologic data of rotavirus serotypes for the application of polyvalent rotavirus vaccines. Epidemiological studies of rotavirus serotypes in Korea have been reported only in limited areas with small number of cases. Authors tried to investigate the distribution of rotavirus G serotypes in ChungJu area with RT-PCR. Method: Stool specimens were collected from 202 children with acute diarrheal symptoms, who admitted to or visited Kon-Kuk University Hospital in ChungJu from June 1998 to May 1999. Samples were screened for rotavirus with EIA method (TestPack Rotavirus, Abbott Laboratories) and rotavirus G Serotypes were determined by RT-PCR. Results: Rotavirus was positive in 46.6%. The incidence of G serotypes was as follows; G1 10%, G2 10%, G3 28%, G4 26%, and G9 20%. There were three cases of multiple serotypes; G1 with G9, G2 with G9, and G4 with G9. Serotype of G8 was not found. Conclusion: The proportion of G serotypes in ChungJu is much different from previous reports. Serotype of G9 was found which had not been reported in Korean children till now. Long term plans for the investigation of rotavirus serotypes must be needed in wide area.

  • PDF

Image System Using Dual Energy Detector (이중 에너지 검출기를 이용한 영상 시스템)

  • Yeo, Hwa-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.9
    • /
    • pp.3517-3523
    • /
    • 2010
  • Single exposure dual X-ray imaging can be used to separate soft and dense-material images for medical and industrial applications. This study keep focusing baggage inspection system(BIS) specifically. New detector modules for single exposure dual X-ray imaging are consisted of low energy detector (LED) and high energy detector (HED). First, the optimized thickness of copper filter coupled HED to separate low energy and high energy was simulated by the given X-ray energy (140 kVp, 1 mA) using Monte Carlo simulation codes, MCNPX. So as a result of simulation, the copper filter thickness is 0.7 mm. For the design of PIN photodiode, ATLAS device simulation tool was used. 16 channels PIN photodiode of 1.5 mm ${\times}$ 3.2 mm for Dual X-ray imaging detector was fabricated in the process of ETRI. And its dark current and quantum efficiency, terminal capacitance were measured. It was proven that the Lanex Fast B coupled HED were a sufficient candidate to replace the CsI(Tl) commerced in dual X-ray system, since these give a strong signal, overcoming system noise. Finally dual X-ray image was acquired through correction of the LED X-ray Image and the HED X-ray Image.

Automatic Exposure Control Performance Evaluation of Digital Radiographic Imaging System by Manufacturer Using Coins (동전을 이용한 제조사 별 디지털 방사선 영상 시스템의 자동노출제어 성능 평가)

  • Lim, Se-Hun;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.45 no.1
    • /
    • pp.1-9
    • /
    • 2022
  • In this study, we proposed an image quality control for an automatic exposure control (AEC) of digital radiographic imaging system and tried to analyze the performance of the AEC by various manufacturer. The subjects of the experiment were analyzed for the AEC image quality evaluation using digital radiation generators from four manufacturer such as PHILIPS, GE Healthcare, SAMSUNG Healthcare, DK Medical Solution. We used as materials for the implementation of the image quality evaluation by coins (500 won, KOMSCO, Korea). This study evaluated the performance evaluation of the AEC as image quality and exposure dose (Milliampere-seconds; mAs). The image quality evaluation was tried visual assessment by two radiologic technologists and contrast to noise (CNR) by ImageJ. The exposure dose investigated mAs on digital radiation generators. The radiographic coin images acquired 360 images based on change in the control factors of the AEC, which were kVp, the consistency of field configuration and dominant zone, sensitivity and density. As a result, there was a significant difference in the AEC performance between manufacturer. The CNR by the AEC for each manufacturer showed a difference of up to about 1.9 times. The exposed tube current by the AEC for each manufacturer showed a difference of up to about 5.8 times. It is expected that our proposed evaluation method using coins could be applied as the AEC performance evaluation method in the future.

High VPP Combination Chemotherapy for Advanced Non-Small Cell Lung Cancer (진행된 비소세포 폐암에 대한 High-VPP 복합화학요법의 효과)

  • Hong, Seok-Cheol;Han, Pyo-Seong;Lee, Jong-Jin;Cho, Hai-Jeong;Kim, Ju-Ock;Kim, Sun-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.4
    • /
    • pp.367-377
    • /
    • 1993
  • Background: The benefits of combination chemotherapy in unresectable non-small cell lung cancer remain uncertain. But, according to the recent reports, the response rates of cisplatin-based polychemotherapy regimens are higher than those of single agent. Also, the response rates of high-dose cisplatin group are higher than those of low-dose cisplatin group. In attemp to answer the question whether treatments, combination chemotherapy (high VPP) and combination chemotherapy with radiation therapy, improve survival in advanced non-small cell lung cancer, we begin to study. Method: Thirty-five patients above stage III, diagnosed histologically as non-small cell lung cancer, were enrolled. Among them, nineteen received a combination chemotherapy consisting of VP-16 & high-dose cisplatin (100 $mg/m^2$) and/or radiation therapy. The other group (16 subjects) received no therapy. To investigate the differences of survival and response rates between two groups and the side effects related to therapy, we reviewed patients' records. Results: 1) The overall objective response rate was 47%(9/19) with one complete remission. 2) In patients who received polychemotherapy and radiation therapy, the response rate was 60%(6/10) with one complete remission and survival rates of 3 months, 6 months and 12 months were 100%, 70% and 40%. 3) In patients who received polychemotherapy, the response rate was 33% (3/9) with no complete remission and survival rates of 3 months, 6 months and 12 months were 78%, 67% and 33%. 4) Overall, treated patients survived significantly longer (p<0.05) than non-treated patients (median survival 307 days versus 95 days). 5) Analysis of the various prognostic factors disclosed that good performance status, stage III and squamous cell type showed the good response rates. 6) The toxicities were nausea and/or vomiting (100%), alopecia (90%), anemia (79%), leukopenia (69%), thrombocytopenia (2%), increased creatinine (16%) and neurotoxicity (5%). Conclusion: According to above results, there are relatively good results that high VPP combination chemotherapy in advanced non-small cell lung cancer improves survival in the treated group than in the non-treated group. Thus, it is considerd that we select the patients with proper indications and treat them with effective chemotherpy and radiation therapy. But, because improvement related to high VPP ploychemotherapy is not marked in this study, it is necessary that we should investigate follow-up studies in many cases.

  • PDF

Shape Optimization of Multilayer Bellows by Using Sequential Experimental Design (순차적 실험계획법을 적용한 다층관 벨로우즈 형상 최적설계)

  • Oh, Sang-Kyun;Lee, Kwang-Ki;Suh, Chang-Hee;Jung, Yun-Chul;Kim, Young-Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.9
    • /
    • pp.1007-1013
    • /
    • 2011
  • Because of their high flexibility and durability, multilayer bellows are manufactured for use in commercial vehicles, while single-layer bellows are manufactured for use in passenger vehicles. A study based on the finite element method (FEM) and shape optimization for the single-layer bellows has been actively performed; however, until now, a study based on the FEM has rarely been performed for the multilayer bellows with gaps between the layers. This paper presents a finite-element modeling scheme for the multilayer bellows to improve simulation reliability during the evaluation of stress and flexibility. For performing shape optimization for the multilayer bellows, DOE (design of experiment) and the Kriging metamodel followed by the D-optimal method are used.

A Study of The Correlation of The Area Dose with Residual CT Contrast Media and MRI Contrast Media during The Use of General Imaging Automatic Exposure Control System (일반촬영 자동노출제어장치 사용 시 잔존 CT 조영제와 MRI 조영제에 따른 면적선량의 상관성 연구)

  • Hong, Chan-Woo;Park, Jin-Hun;Lee, Jung-Min;Seo, Young-Deuk
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.619-627
    • /
    • 2016
  • The purpose of this study is to investigate the effect of CT contrast agent and MRI contrast agent on the area dose in the body when using automatic exposure control system in general radiography. After making rectangular holes in the center of the abdominal thickness paraffin phantom, CT contrast agent and MRI contrast agent were respectively diluted with physiological saline solution for contrast medium dilution ratio of 10:0, 9:1, 8:2, 7:3, 6:4, 5:5, 4:6, 3:7, 2:8, 1:9, 0:10%. Each experiment was set to 78 kVp, 320 mA, which is the proper condition for KUB photography, and thereafter a total of 30 inspections were made for each dilution ratio using an automatic exposure control device, and the area dose corresponding to the dilution ratio of each contrast agent, Average comparison and correlation analysis were performed on the exposure index. As a result, the CT contrast agent and the MRI contrast agent appeared different in area dose according to the dilution ratio(p<0.05), and as the dilution ratio increased, the area dose increased for CT contrast agent and MRI contrast agent(P<0.05). In each test, the exposure index showed the manufacturer's recommendation of 200-800 EI value, and the exposure index and area dose increased as the area dose increased(p<0.05). In conclusion, CT contrast agent and MRI contrast agent confirmed to increase the area dose by general imaging test using all automatic exposure control device. Therefore, it is considered that it is necessary to perform it after the contrast medium has been excreted sufficiently when using usual imaging test after using the contrast agent in CT and MRI examination.