• 제목/요약/키워드: and Plumbing)

검색결과 126건 처리시간 0.029초

에너지 절약을 고려한 급수급탕 설비 설계 (A consideration on energy saving for plumbing design)

  • 김진현
    • 대한설비공학회지:설비저널
    • /
    • 제27권5호
    • /
    • pp.471-475
    • /
    • 1998
  • 위생설비 중 급수, 급탕설비는 공기조화설비에 비해 상대적으로 간단한 설비로 인식되어 왔다. 물론 공사비 측면이나 자동제어의 복잡성 등 공기조화설비에 비해 단순한 설비인 것은 사실이지만 급수·급탕설비는 나름대로 시스템측면에서 고려하면 현재 우리가 적용하고 있는 시스템보다 조금이라도 나은 설계가 이루어질 것으로 사료된다. 본고에서는 급수급탕설비 시스템 설계의 일부분을 다루어 보고자 한다.

  • PDF

유닛모듈러 기반 도시형 생활주택의 BIM 모델링 프로세스 개발 연구 (The Study on the Developing Process of BIM Modeling for Urban-life-housing Based on Unit Modular)

  • 이창재;임석호
    • KIEAE Journal
    • /
    • 제12권6호
    • /
    • pp.77-84
    • /
    • 2012
  • The current architectural design of unit modular has been based on 2D of CAD program, so unit modular character which needs unit information management, as a dried-member system, has no effect on design process. The purpose of this study is We have developed a suitable BIM design process, according to various works of construction, then tried to contribute to supply and activation of the urban-life-housing based on unit modular. The BIM modeling process based on unit modular has been in order of unit combination with preparing manual classification, and, it has been constructed, at construction site, from housing foundation to roof finish by Bottom-up method. At a manufacturing factory, it has been produced in order of 1) grouping materials and parts, 2) fabricating unit boxes, and 3) interference examination of unit boxes, and each order has been classified as housing structure, architecture, plumbing process separately. At a construction site, the fabrication has been done in order of, like as a real housing construction scenario, 1) RC foundation work 2) unit module job-site-fabrication work, 3) roof truss work, 4) plumbing and HVAC work, and 5) housing interior finish work. After modeling process, the interference examination on each work of construction has finally completed modeling. The Unit modular utilizing BIM modeling can make easy housing maintenance through systematic control with preparing manual of unit module information, and securing accurate and speedy construction information. And it will promote design credibility and create maximum effect of unit modular construction method, such as construction period reduction and upgrade of construction quality, etc., through the computer simulation as real as construction environment in cyber space, and with the interfering examination.

Effects of Diverse Water Pipe Materials on Bacterial Communities and Water Quality in the Annular Reactor

  • Jang, Hyun-Jung;Choi, Young-June;Ka, Jong-Ok
    • Journal of Microbiology and Biotechnology
    • /
    • 제21권2호
    • /
    • pp.115-123
    • /
    • 2011
  • To investigate the effects of pipe materials on biofilm accumulation and water quality, an annular reactor with the sample coupons of four pipe materials (steel, copper, stainless steel, and polyvinyl chloride) was operated under hydraulic conditions similar to a real plumbing system for 15 months. The bacterial concentrations were substantially increased in the steel and copper reactors with progression of corrosion, whereas those in stainless steel (STS) and polyvinyl chloride (PVC) reactors were affected mainly by water temperature. The heterotrophic plate count (HPC) of biofilms was about 100 times higher on steel pipe than other pipes throughout the experiment, with the STS pipe showing the lowest bacterial number at the end of the operation. Analysis of the 16S rDNA sequences of 176 cultivated isolates revealed that 66.5% was Proteobacteria and the others included unclassified bacteria, Actinobacteria, and Bacilli. Regardless of the pipe materials, Sphingomonas was the predominant species in all biofilms. PCR-DGGE analysis showed that steel pipe exhibited the highest bacterial diversity among the metallic pipes, and the DGGE profile of biofilm on PVC showed three additional bands not detected from the profiles of the metallic materials. Environmental scanning electron microscopy showed that corrosion level and biofilm accumulation were the least in the STS coupon. These results suggest that the STS pipe is the best material for plumbing systems in terms of the microbiological aspects of water quality.

BIM기반 MEP공사 시공용 도면 작성 자동화 프로세스 제안 (An Automated Process to Produce Shop Drawings for MEP Works in BIM Environment)

  • 최창현;권대용;조상호;김주형
    • 한국BIM학회 논문집
    • /
    • 제10권4호
    • /
    • pp.22-31
    • /
    • 2020
  • Shop drawing tasks conducted after finishing coordinated or engineering design have great influences on the quality and cost of a project. However, despite the development of commercial BIM applications, shop drawings have mainly produced manually in certain engineering fields. Incorrect shop drawings with human errors have occurred various problems such as cost overrun, time delay and reworks. An automated shop drawing publishing from BIM is expected to resolve these problems. Despite attempts for automate shop drawing production, the field of mechanical, electrical and plumbing (MEP) is yet regarded challenging due to complexity of components and connection. In this research, we develop a process for automated producing 3D MEP shop drawings in BIM environment as following steps: to analyze conventional MEP shop drawing process, to identify detailed process that can be automated, to classify existing MEP objects and assign codes usable in BIM, and to develop an application. The validation of automated process is conducted against 10 clean room projects in which MEP is more complex and its cost is higher than other projects in terms of productivity and workers' satisfaction. Results show that the number of manpower for shop drawing is reduced by 30%, and the working time is shortened by 31%. Personal opinions of involved practitioners is interpreted as positive as the average rate of agrement on practicability, easy-to-use and necessary retouch tasks is around 66%.

A Waterborne Outbreak and Detection of Cryptosporidium Oocysts in Drinking Water of an Older High-Rise Apartment Complex in Seoul

  • Cho, Eun-Joo;Yang, Jin-Young;Lee, Eun-Sook;Kim, Se-Chul;Cha, So-Yang;Kim, Sung-Tek;Lee, Man-Ho;Han, Sun-Hee;Park, Young-Sang
    • Parasites, Hosts and Diseases
    • /
    • 제51권4호
    • /
    • pp.461-466
    • /
    • 2013
  • From May to June 2012, a waterborne outbreak of 124 cases of cryptosporidiosis occurred in the plumbing system of an older high-rise apartment complex in Seoul, Republic of Korea. The residents of this apartment complex had symptoms of watery diarrhea and vomiting. Tap water samples in the apartment complex and its adjacent buildings were collected and tested for 57 parameters under the Korean Drinking Water Standards and for additional 11 microbiological parameters. The microbiological parameters included total colony counts, Clostridium perfringens, Enterococcus, fecal streptococcus, Salmonella, Shigella, Pseudomonas aeruginosa, Cryptosporidium oocysts, Giardia cysts, total culturable virus, and Norovirus. While the tap water samples of the adjacent buildings complied with the Korean Drinking Water Standards for all parameters, fecal bacteria and Cryptosporidium oocysts were detected in the tap water samples of the outbreak apartment complex. It turned out that the agent of the disease was Cryptosporidium parvum. The drinking water was polluted with sewage from a septic tank in the apartment complex. To remove C. parvum oocysts, we conducted physical processes of cleaning the water storage tanks, flushing the indoor pipes, and replacing old pipes with new ones. Finally we restored the clean drinking water to the apartment complex after identification of no oocysts.

수리조선 작업장에서의 공기중 석면 노출에 관한 연구 (A Study on Exposure to Asbestos a Shipbuilding Repair Business)

  • 심상효;정희태;송기민;김윤신;강용선
    • 한국환경보건학회지
    • /
    • 제34권4호
    • /
    • pp.279-284
    • /
    • 2008
  • This paper aims to provide basic data for work environment control, prevention of worker exposure to asbestos and improvement of air quality to protect workers ‘health after measuring the level of airborne asbestos and workers' exposure in a shipbuilding repair businesses. For this study, a total of 27 samples were collected from 27 workers who had been exposed to asbestos during engine, piping, boiler and other manufacturing processes in 'A' Shipbuilding Repair Company in Gyeongnam. This research was conducted from Oct. 1 to 30, 2007 and had the following results: The target group (27 workers) consisted of all men with an average age of 35.9 years and 6.6 years of work on average. Among them, fifteen 15 (55.6%) were smokers. In terms of their duties at work, there were 12 plumbing repair engineers (44.4%), 8 boiler repair engineers (29.6%) and 7 engine engineers (25.9%). The geometric mean concentration of airborne asbestos was 0.004 f/cc. A total of 4 samples exceeded the exposure limit. In particular, three exceeded the legal limit by more than double, which means that some workers have been highly exposed to asbestos. In terms of the concentration of asbestos fibres by work process, plumbing repair was the highest (0.0071 f/cc($0.001{\sim}0.57\;f/cc$)) while boiler was the lowest (0.0015 f/cc($0.001{\sim}0.007\;f/cc$)). Based on this study, proper action needs to be taken as soon as possible to protect workers from the threat of asbestos.

상변화물질(PCM)을 이용한 열교환기용 동파방지밸브에 관한 실험적 연구 (An Experimental Study on the Freezing Protection Valve Using Phase Change Material(PCM) for the Heat Exchanger)

  • 윤재호;김종하;정순영;양윤섭;김성현;송덕용
    • 한국태양에너지학회 논문집
    • /
    • 제32권6호
    • /
    • pp.127-133
    • /
    • 2012
  • This paper is an experimental study on the freezing protection valve used for solar water heating, air-conditioning systems, and plumbing systems. When the phase change occurs from liquid to solid, most of the substances except water volumetrically shrink. And referred to as PCM(Phase Change Material) a substance with such properties, the phase change temperature varies depending on the material. To prevent the freezing of the plumbing system, such as air-conditioning system in the winter season, we developed a several types of freezing protection valve using PCM whose freezing temperature are $2-4^{\circ}C$. The working principle of the freezing protection valve is that the fluid inside the pipe is released to prevent the system-collapse when fluid temperature reaches the freezing temperature of the PCM. And then the valve is closed and returned to the original position automatically when the temperature of the operating fluid rises. In this paper, the operating temperatures, discharge flow rate and the response characteristics of the valve during the operation are tested and investigated. From the results of this research the freezing protection valves employing PCM are expected to be commercialized in the near future.

대용량 포인트 클라우드 기반 파이프 형상 역설계 자동화 방법 연구 (Large Point Cloud-based Pipe Shape Reverse Engineering Automation Method)

  • 강태욱;김지은
    • 한국산학기술학회논문지
    • /
    • 제17권3호
    • /
    • pp.692-698
    • /
    • 2016
  • 최근 신규 시설물 건설이 줄어들고 기존 시설물에 대한 확장공사 및 유지보수가 시설물 관리에 있어서 갈수록 큰 비중을 차지하고 있다. 이런 배경에서, 건축에서 가장 큰 관리 및 운영비용을 차지하고 있는 MEP(Mechanical Electrical and Plumbing) 설비에 대한 역설계 연구 필요성이 높아지고 있다. 연구의 목적은 대용량 MEP 포인트 클라우드의 파이프 배관 형상에 대한 역설계 자동화 방법을 제시하는 것이다. 이를 위해, 관련 연구를 조사하고, 대용량 포인트 클라우드를 고려한 형상 역설계 자동화 방법을 제안한다. 이를 바탕으로, 프로토타입을 개발하고, 결과를 검증하였으며, 3차원 대용량 포인트 클라우드 데이터 검색 등과 관련된 렌더링 성능을 측정하였다. 포인트 클라우드 샘플들을 준비해 검증한 결과, 제안된 방법에서 렌더링 성능 표준편차는 0.004로 차이가 적어, 대용량 데이터 처리에 적합함을 알 수 있다.

Examining Change Order Reasons for Non-Structural Utility Support Projects in Healthcare Facilities

  • Genota, Naomi P.;Kim, Joseph J.
    • 국제학술발표논문집
    • /
    • The 9th International Conference on Construction Engineering and Project Management
    • /
    • pp.188-195
    • /
    • 2022
  • Although issuing change orders is a common practice in the construction phase of any project, non-structural utility subcontractors are struggling and seek to find a way to reduce change orders. Therefore, this paper presents the analysis results on change orders to cultivate possible suggestions and solutions on how to reduce or minimize change orders in mechanical, electrical, and plumbing (MEP) works. Change orders in non-structural utility works are analyzed based on six categories such as rerouting and change of location, changes in weight, rejected design by Office of Statewide Health Planning and Development, District Structural Engineer, or the Structural Engineer of Record, unforeseen conditions, changed equipment, and owner-initiated change. The analysis findings showed that rerouting and changing location is the most significant cause, followed by unforeseen conditions. The results not only contribute to the existing body of knowledge on change order research area, but also help MEP contractors reduce the time and cost of change orders.

  • PDF