• Title/Summary/Keyword: and Access Grid

Search Result 190, Processing Time 0.023 seconds

A Case Study on Energy focused Smart City, London of the UK: Based on the Framework of 'Business Model Innovation'

  • Song, Minzheong
    • International journal of advanced smart convergence
    • /
    • v.9 no.2
    • /
    • pp.8-19
    • /
    • 2020
  • We see an energy fucused smart city evolution of the UK along with the project of "Smart London Plan (SLP)." A theoretical logic of business model innovation has been discussed and a research framework of evolving energy focused smart city is formulated. The starting point is the silo system. In the second stage, the private investment in smart meters establishes a basement for next stages. As results, the UK's smart energy sector has evolved from smart meter installation through smart grid to new business models such as water-energy nexus and microgrid. Before smart meter installation of the government, the electricity system was centralized. However, after consumer engagement plan has been set to make them understand benefits that they can secure through smart meters, the customer behavior has been changed. The data analytics firm enables greater understanding of consumer behavior and it helps energy industry to be smart via controlling, securing and using that data to improve the energy system. In the third stage, distribution network operators (DNOs)' access to smart meter data has been allowed and the segmentation starts. In the fourth stage, with collaboration of Ofwat and Ofgem, it is possible to eliminate unnecessary duplication of works and reduce interest conflict between water and electricity. In the fifth stage, smart meter and grid has been integrated as an "adaptive" system and a transition from DNO to DSO is accomplished for the integrated operation. Microgrid is a prototype for an "adaptive" smart grid. Previous steps enable London to accomplish a platform leadership to support the increasing electrification of the heating and transport sector and smart home.

A Study on the Analysis of the Configuration and Properties of University Campus Cores through Space Syntax (공간구문론을 이용한 대학교 캠퍼스 코어의 공간구조 유형 및 특성 분석)

  • Lee, Dong-Joo;Ko, Eun-Hyung
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.16 no.6
    • /
    • pp.13-20
    • /
    • 2009
  • The purpose of this study is to analyze the configuration and properties of university campus cores for systematic approach and planning through space syntax based on master plans of 55 universities in Korea. The results of this study showed that: first, the campus cores were classified into 10 types through axial map analysis. They were '一 type', '二 type', 'ㄱ type', 'T type', '+ type', 'radiation type', 'grid type', 'polygon type', 'tree structure type' and 'combination type'.(table 7) The frequency of '一 type' was the highest by 27.2%, and 'radiation type' was the next by 14.5%; second, the integration value was 2.03(+ type), te90(grid type), te75(ㄱ type), te74(一 type), te67(二 type), te63(T type), te46(polygon type), te347(tree structure type) and te343(radiation type).(table 9) We could categorize the 'radiation type' and the 'tree structure type' as the first group, the 'polygon type' as the second group, the 'T type', the '二 type', the '一 type', and the 'ㄱ type' as the third group, the 'grid type' as the fourth group, the '+ type' as the fifth group; third, cases that the integration value of access road was very low(58.2%) was much more frequent than that of very high(32.7%); fourth, the most important space in the campus core were as follows: library and media center(18.1%), administration buildings and headquarters(15.7%), student center(15.7%), lecturing building(13.9%), streets and squares(13.3%).

Protection Strategies Against False Data Injection Attacks with Uncertain Information on Electric Power Grids

  • Bae, Junhyung;Lee, Seonghun;Kim, Young-Woo;Kim, Jong-Hae
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.19-28
    • /
    • 2017
  • False data injection attacks have recently been introduced as one of important issues related to cyber-attacks on electric power grids. These attacks aim to compromise the readings of multiple power meters in order to mislead the operation and control centers. Recent studies have shown that if a malicious attacker has complete knowledge of the power grid topology and branch admittances, s/he can adjust the false data injection attack such that the attack remains undetected and successfully passes the bad data detection tests that are used in power system state estimation. In this paper, we investigate that a practical false data injection attack is essentially a cyber-attack with uncertain information due to the attackers lack of knowledge with respect to the power grid parameters because the attacker has limited physical access to electric facilities and limited resources to compromise meters. We mathematically formulated a method of identifying the most vulnerable locations to false data injection attack. Furthermore, we suggest minimum topology changes or phasor measurement units (PMUs) installation in the given power grids for mitigating such attacks and indicate a new security metrics that can compare different power grid topologies. The proposed metrics for performance is verified in standard IEEE 30-bus system. We show that the robustness of grids can be improved dramatically with minimum topology changes and low cost.

Experimental investigation of Scalability of DDR DRAM packages

  • Crisp, R.
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.17 no.4
    • /
    • pp.73-76
    • /
    • 2010
  • A two-facet approach was used to investigate the parametric performance of functional high-speed DDR3 (Double Data Rate) DRAM (Dynamic Random Access Memory) die placed in different types of BGA (Ball Grid Array) packages: wire-bonded BGA (FBGA, Fine Ball Grid Array), flip-chip (FCBGA) and lead-bonded $microBGA^{(R)}$. In the first section, packaged live DDR3 die were tested using automatic test equipment using high-resolution shmoo plots. It was found that the best timing and voltage margin was obtained using the lead-bonded microBGA, followed by the wire-bonded FBGA with the FCBGA exhibiting the worst performance of the three types tested. In particular the flip-chip packaged devices exhibited reduced operating voltage margin. In the second part of this work a test system was designed and constructed to mimic the electrical environment of the data bus in a PC's CPU-Memory subsystem that used a single DIMM (Dual In Line Memory Module) socket in point-to-point and point-to-two-point configurations. The emulation system was used to examine signal integrity for system-level operation at speeds in excess of 6 Gb/pin/sec in order to assess the frequency extensibility of the signal-carrying path of the microBGA considered for future high-speed DRAM packaging. The analyzed signal path was driven from either end of the data bus by a GaAs laser driver capable of operation beyond 10 GHz. Eye diagrams were measured using a high speed sampling oscilloscope with a pulse generator providing a pseudo-random bit sequence stimulus for the laser drivers. The memory controller was emulated using a circuit implemented on a BGA interposer employing the laser driver while the active DRAM was modeled using the same type of laser driver mounted to the DIMM module. A custom silicon loading die was designed and fabricated and placed into the microBGA packages that were attached to an instrumented DIMM module. It was found that 6.6 Gb/sec/pin operation appears feasible in both point to point and point to two point configurations when the input capacitance is limited to 2pF.

Modeling and Characterization of Low Voltage Access Network for Narrowband Powerline Communications

  • Masood, Bilal;Haider, Arsalan;Baig, Sobia
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.443-450
    • /
    • 2017
  • Nowadays, Power Line Communication (PLC) is gaining high attention from industry and electric supply companies for the services like demand response, demand side management and Advanced Metering Infrastructure (AMI). The reliable services to consumers using PLC can be provided by utilizing an efficient PLC channel for which sophisticated channel modeling is very important. This paper presents characterization of a Low Voltage (LV) access network for Narrowband Power Line Communications (NB-PLC) using transmission line (TL) theory and a Simulink model. The TL theory analysis not only includes the constant parameters but frequency selectivity is also introduced in these parameters such as resistance, conductance and impedances. However, the proposed Simulink channel model offers an analysis and characterization of capacitive coupler, network impedance and channel transfer function for NB-PLC. Analysis of analytical and simulated results shows a close agreement of the channel transfer function. In the absence of a standardized NBPLC channel model, this research work can prove significant in improving the efficiency and accuracy of NB-PLC communication transceivers for Smart Grid communications.

Separate Networks and an Authentication Framework in AMI for Secure Smart Grid (스마트그리드 보호를 위한 AMI 망 분리 및 인증 프레임워크)

  • Choi, Jae-Duck;Seo, Jung-Taek
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.22 no.3
    • /
    • pp.525-536
    • /
    • 2012
  • This paper proposes methods of securing Smart Grid system against various types of cyber threats by separating AMI networks from the public network, the Internet, and providing an AMI specific authentication framework. Due to the fact that thousands and millions of AMI devices to be deployed would be directly or indirectly connected to the public network without any authentication procedures for access control, currently being developed AMI architectures could be widely exposed to considerable number of penetrating attacks. Furthermore, there have not been a sufficient number of researches on authentication frameworks with basis on the specific circumstances of AMI networking that should support varied authentication protocols among security associations and AMI linking devices. This work makes a proposal of isolating smart meters from HAN devices and the Internet and integrating network/application level authentication frameworks with an EAP-based authentication architecture. These approaches are beneficial to deploy AMI with security and efficiency.

Research on UAV access deployment algorithm based on improved virtual force model

  • Zhang, Shuchang;Wu, Duanpo;Jiang, Lurong;Jin, Xinyu;Cen, Shuwei
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.8
    • /
    • pp.2606-2626
    • /
    • 2022
  • In this paper, a unmanned aerial vehicle (UAV) access deployment algorithm is proposed, which is based on an improved virtual force model to solve the poor coverage quality of UAVs caused by limited number of UAVs and random mobility of users in the deployment process of UAV base station. First, the UAV-adapted Harris Hawks optimization (U-AHHO) algorithm is proposed to maximize the coverage of users in a given hotspot. Then, a virtual force improvement model based on user perception (UP-VFIM) is constructed to sense the mobile trend of mobile users. Finally, a UAV motion algorithm based on multi-virtual force sharing (U-MVFS) is proposed to improve the ability of UAVs to perceive the moving trend of user equipments (UEs). The UAV independently controls its movement and provides follow-up services for mobile UEs in the hotspot by computing the virtual force it receives over a specific period. Simulation results show that compared with the greedy-grid algorithm with different spacing, the average service rate of UEs of the U-AHHO algorithm is increased by 2.6% to 35.3% on average. Compared with the baseline scheme, using UP-VFIM and U-MVFS algorithms at the same time increases the average of 34.5% to 67.9% and 9.82% to 43.62% under different UE numbers and moving speeds, respectively.

Some Characteristics of the Performance in Comparison with Indexing techniques for File Organization (화일조직을 위한 인덱싱 기법의 성능 특성 비교)

  • Lee, Gu-Nam
    • Journal of The Korean Association of Information Education
    • /
    • v.1 no.1
    • /
    • pp.49-59
    • /
    • 1997
  • In this thesis, To provide the base of effective data access methods, performance of some indexing techniques used gent-Tally are compared. They are classified as primary key and multikey. For primary key method, made a comparative analysis on Static index. Dynamic index and Hashing. For multikey indexing method K-d tree, K-d-B tree, Inverted file and Grid file of which characteristics are compared. In many applications, multikey indexings are more requested, but are not supplied enough. So, to satisfy users' request - more fast, more exact and to be applied according to the trend of being huge database systems, it is requested more study about multikey data access methods.

  • PDF

Performance Analysis of Load Balanced Metadata Catalog Service (부하분산 메타데이터 카탈로그 서비스의 성능 분석)

  • Ahn, Sunil;Lee, Sehoon;Kim, Namgyu;Hwang, Soonwook
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2007.11a
    • /
    • pp.555-559
    • /
    • 2007
  • AMGA is a metadata catalogue service which offers access to metadata for files stored on the Grid. We evaluated the performance of AMGA and analyzed overhead in the current AMGA implementation. It had 700% poor throughput (read/insert per second) compared with the direct DB access. The biggest overhead was in managing GSI/SSL Connections, degrading throughput about 350%. We alsomeasured the throughput of load-balanced AMGA services, and it showed linear throughput improvement when we increased the number of AMGA server. In addition, we measured the throughputin the WAN environment, and it showed the number of the maximum connections that an AMGA server can handle is the most critical factor in the throughput.

  • PDF

Estimation of Monthly Precipitation in North Korea Using PRISM and Digital Elevation Model (PRISM과 상세 지형정보에 근거한 북한지역 강수량 분포 추정)

  • Kim, Dae-Jun;Yun, Jin-I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.13 no.1
    • /
    • pp.35-40
    • /
    • 2011
  • While high-definition precipitation maps with a 270 m spatial resolution are available for South Korea, there is little information on geospatial availability of precipitation water for the famine - plagued North Korea. The restricted data access and sparse observations prohibit application of the widely used PRISM (Parameter-elevation Regressions on Independent Slopes Model) to North Korea for fine-resolution mapping of precipitation. A hybrid method which complements the PRISM grid with a sub-grid scale elevation function is suggested to estimate precipitation for remote areas with little data such as North Korea. The fine scale elevation - precipitation regressions for four sloping aspects were derived from 546 observation points in South Korea. A 'virtual' elevation surface at a 270 m grid spacing was generated by inverse distance weighed averaging of the station elevations of 78 KMA (Korea Meteorological Administration) synoptic stations. A 'real' elevation surface made up from both 78 synoptic and 468 automated weather stations (AWS) was also generated and subtracted from the virtual surface to get elevation difference at each point. The same procedure was done for monthly precipitation to get the precipitation difference at each point. A regression analysis was applied to derive the aspect - specific coefficient of precipitation change with a unit increase in elevation. The elevation difference between 'virtual' and 'real' surface was calculated for each 270m grid points across North Korea and the regression coefficients were applied to obtain the precipitation corrections for the PRISM grid. The correction terms are now added to the PRISM generated low resolution (~2.4 km) precipitation map to produce the 270 m high resolution map compatible with those available for South Korea. According to the final product, the spatial average precipitation for entire territory of North Korea is 1,196 mm for a climatological normal year (1971-2000) with standard deviation of 298 mm.