• Title/Summary/Keyword: and 100s

Search Result 18,232, Processing Time 0.054 seconds

Growth Inhibitory Activity of Enterococcus faecium Isolated from Bovine Intestinal Tract against Enterobacter sakazakii (소 장관 유래 Enterococcus faecium의 Enterobacter sakazakii에 대한 생육저해활성)

  • Park, Ju-Hui;Yoon, Sung-Sik;Park, Young-Seo
    • Food Science of Animal Resources
    • /
    • v.28 no.1
    • /
    • pp.99-104
    • /
    • 2008
  • A lactic acid bacterium showing growth inhibitory activity against Enterobacter sakazakii was isolated from bovine intestinal tracts. From biochemical and molecular biological studies, the isolate was identified and named as Enterococcus faecium JH95. This strain was resistant to kanamycin and streptomycin at a concentration of $100{\mu}g/mL$. E. faecium JH95 had high antimicrobial activity against food-borne pathogens such as Escherichia coli O157:H7, Listeria monocytogenes, Salmonella typhimurium, Staphylococcus aureus, and Clostridium perfrigens. The culture supernatant of this strain did not have antimicrobial activity. The culture broth of this strain failed to show the antimicrobial activity by heat treatment at $100^{\circ}C$ for 5 min or by pretense treatments for 2 hr. This result suggested that the putative antimicrobial substance produced by E. faecium JH95 is likely a protein which is not secreted into culture medium.

8bit 100MHz DAC design for high speed sampling (고속 샘플링 8bit 100MHz DAC 설계)

  • Lee, Hun-Ki;Choi, Kyu-Hoon
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.1241-1246
    • /
    • 2005
  • This paper described an 8bit, 100Msample/s CMOS D/A converter using a glich-time minimization technique for the high-speed sampling rate of 100MHz level. The proposed DAC was implemented in 0,35um Hynix CMOS technology and adopts a current mode architecture to optimize sampling rate, resolution, chip area. The DAC linear characteristics was similar to the proposed specification the prototype error between DNL and INL is less than ${\pm}0.09LSB$ respectively. Also, fab-out chip was tested, analysed the cause of error operation, and proposed the field considerations for chip test.

  • PDF

Effect of Sterilization Conditions on Microbial Reduction in Cleaning Tools (살균 조건이 세척 도구 중 미생물 저감화에 미치는 영향)

  • Im, Ji-Yu;Kim, Chae-Young;Kim, Eun-yeong;Kim, Min-jin;Kim, Jung-Beom
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.5
    • /
    • pp.310-316
    • /
    • 2022
  • In this study, we compared the microbial reduction effects of drying, hot water, and microwave sterilization in scourers and dishcloths to suggest a most suitable sterilization method. Three scourer types (silver, copper, and mesh) were used, and three dishcloth types (silver, bamboo, and cotton) were used. Drying time dependent reduction in Escherichia coli was high in silver and copper scourers, but minimal bacterial reduction was obtained against Bacillus cereus in all scourers and dishcloths. In scourers, E. coli was not detected after ≥30 s of hot water sterilization at 77℃, and B. cereus was not detected after ≥60 s of hot water sterilization at 100℃. In dishcloths, E. coli was not detected after hot water sterilization at 77℃ for ≥30 s, but B. cereus was detected after hot water sterilization at 100℃ for ≥60 s. In scourers, E. coli was not detected after microwave sterilization at 700 W for 3 min, but B. cereus was detected. In dishcloths, E. coli was not detected after microwave sterilization with 700 W for ≥1 min, but B. cereus was detected in the cotton dishcloth even after sterilization for 3 min. In conclusion, the use of antimicrobial scourers (silver and copper) and dishcloths (silver and bamboo) are not sufficient to reduce the microbial contamination. The guideline provided by the Ministry of Food and Drug Safety suggesting dishcloth sterilization via hot water at 100℃ for 30 s was also found to be insufficient. Based on our research, we suggest that the most effective methods of microbial management are submerging scourers in hot water at 100℃ for ≥1 min, and sterilizing dishcloths for ≥3 min using a 700 W microwave.

Epidemiological trends of gallbladder cancer in Australia between 1982 to 2018: A population-based study utilizing the Australian Cancer Database

  • Taha Mollah;Marc Chia;Luke C. Wang;Prasenjit Modak;Kirby R. Qin
    • Annals of Hepato-Biliary-Pancreatic Surgery
    • /
    • v.26 no.3
    • /
    • pp.263-269
    • /
    • 2022
  • Backgrounds/Aims: Gallbladder cancer (GBC) is a rare neoplasm. The epidemiology of GBC has not been updated in Australia for over five decades. Methods: Data of all Australian patients diagnosed with GBC at any age from 1982 to 2018 were identified from the Australian Cancer Database. Age-standardized rates were calculated and joinpoint analysis was performed to ascertain the trends of incidence and mortality of GBC. Results: Between 1982 and 2018, there were 22,745 cases of GBC and 11,054 GBC-related deaths in Australia. There were three distinct periods showing changed incidence. Period 1 (1982-1995) was stable. Period 2 (1996-2006) showed reduced incidence in females (3.6 to 2.8/100,000; p < 0.01) and all Australians (3.7 to 2.8/100,000, p < 0.01). Period 3 (2006-2017) demonstrated significantly increased incidence in all groups (males: 2.7 to 4.0/100,000, p < 0.01; females: 2.8 to 3.5/100,000, p < 0.01; all Australians: 2.8 to 3.7/100,000, p < 0.01). Incidence between females and males had declined from 1.10 : 1 in 1982 to 0.87 : 1 in 2017. There was a 71% reduction in mortality (3.1 to 0.9/100,000; p < 0.01). Median age at diagnosis increased from 69.7 to 74.3 years for females and from 67.2 to 73.3 years for males. Increasing incidence in the 6th to 8th decade of life in males, compared to previous years, was noted. Conclusions: Incidence, mortality, sex, and age of GBC have significantly changed in Australia since 1982. Rising incidence of GBC in Australia warrants further investigation.

Isolation of Major foodborne Pathogenic Bacteria from Ready-to-Eat Seafoods and Its Reduction Strategy (해산물식품 중 식중독원인균의 오염패턴 및 저감화 방안)

  • KIM Soon Han;Sin Yeong-Min;Lee Myeong Ja;Shin Pil Ki;Kim Mi Cyeong;Cho Jung Sook;Lee Chang Hee;Lee Young Ja;Chae Kab Ryoung
    • Journal of Life Science
    • /
    • v.15 no.6 s.73
    • /
    • pp.941-947
    • /
    • 2005
  • The contamination frequency of major foodborne pathogenic bacteria was investigated from 213 seafood samples including sliced raw fish and shellfish in Busan and CyeongNam province area. Tested microorganisms were Salmonella spp. Staphyloroccus aureus, Vibrio parahaemolyticus, Escherichia coli O157:H7, Bncillus cereus, Listeria monocytogenes and Campylobacter jejuni. The frequency of isolated microorganisms was V. parahaemolyticus (30.5%), B. cereus (9.9%), S. aureus (3.8%) and other pathogenic bacteria (1.4%). from July to October, total isolation rates were greater than 50% and V. parahaemolyticus was dominant among the microorganisms isolated. The bacteria isolation rate (49.2%) in raw seafoods including shellfishes was higher than one (28.9%) in sliced raw fish. V. parahaemelyticus isolates were resistant to ampicillin (96.9%), amikacin (29.2%) and tetracycline (27.7%), and B. cereus isolates were resistant to ampicillin (100%), Penicillin G (100%), rifampicin (71.4%) and tetracycline (14.3%). The growth of V. parahaemolyticus and B. rereus was greatly inhibited below $10^{\circ}C$, but increased at ambient temperature. Washing seafood with tap water showed to reduce total count of remaining V. parahaemolyticus. Thus temperature control under $10^{\circ}C$, sufficient washing and prompt eating appeared to reduce the risk of food poisoning by these bacteria in seafoods.

Mineral Contents of Hot Water Extracts and Shell of Shellfishes from Western Coast of Korea (서해안 조개류의 껍질과 열수 추출물의 무기질 함량)

  • 김미정;이예경;김순동
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.11 no.4
    • /
    • pp.289-294
    • /
    • 2001
  • Yields of shells, appearance of the shellfishes, mineral contents of the shells and their hot water extracts were determined in six shellfishes such as corb shell(CS). short neck clam(SNC). taste clam(TC), ark shell(AS). top shell(TS) and oyster(OY) from the western coast of Korea. Yields of shells in shellfishes were 70.I~80.5% but yields of TC was the lowest as 40.7%. The highest among weight of the shell the shellfishes was the TS(26.2g) and the lowest weight was TC(5.6g) Colors of CS, SNC, TC. AS. TS and OY were yellowish brown, brown, black. greenish brown and gray. respectively. Ca content of the shell of shellfishes was 36.23~38.78% and the content of K and Na were 0.23~4.54% and 1.48~l.59%, respectively. Contents of Na, Mg, Fe. Mn, Zn, Cu. P and S were in the range of 0.01~0.21%. It also contained heavy metals, such as Pb(1.90~7.75 ppm), Cd(0.5~4.50 ppm), As (1.40~4.30 ppm), Se (0.2~l.50 ppm). Cr(1.00~8.30 ppm) and Hg(0.002~8.2 ppm), Ca content in hot water extracts of shell of shellfish was the highest in TC(2,448 mg/100 g), and the lowest in SNC(115 mg/100 g). K content in TC extracts was the highest with the levels of 952 mg/100 g. P content of TC and SNC were 201 and 0.36 mg/100 g, respectively. The contents of Pb, As, Se and Cr were the highest in the extracts of TC and were 110. 40. 90, 20 $\mu$g/100 g, respectively. But Cd was not detected in the extracts of SNC.

  • PDF

Pulse forming's switching control adopted a Transcranial Magnetic Stimulation Biomedical engineering, Dongju College University (펄스포밍의 스위칭 제어기술을 적용한 경두개 자기자극장치)

  • Kim, Whi-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.3
    • /
    • pp.729-736
    • /
    • 2010
  • In this study, a magnetic stimulation (MS) device with controllable pulse forming technology and pulse shape (MS) is described. The MS device uses an IGBT with appropriate snubbers to switch coil currents up to 6 kA, enabling pulse forming technology control from 5 s to over 100 s. The induced electric field pulses use 2% - 34% less energy and generate 57% - 67% less coil heating compared to matched conventional cosine pulses. MS is used to stimulate rhesus monkey motor cortex in vivo with pulse forming technology of 20 to 100 s, demonstrating the expected decrease of threshold pulse amplitude with increasing pulse forming technology. The technological solutions used in the MS prototype can expand functionality, and reduce power consumption and coil heating in MS, enhancing its research and therapeutic applications.

Antimutagenic Effect of Rresveratrol on Trip P-1 in Salmonella typhimurium TA98 (Trp P-1 변이원성에 대한 Resveratrol의 항돌연변이 효과)

  • 장귀현;안병용;권용주;최동성
    • The Korean Journal of Food And Nutrition
    • /
    • v.14 no.4
    • /
    • pp.329-332
    • /
    • 2001
  • The antimutagenic activity of resveratrol on the mutagenicity induced by Trp P-1 (3-amino-1,4-dime-thyl-5H-pyrido{4,3-b}indole) was studied using the Ames test with Salmonella typhimurium TA98 and 100. Trp P-1 showed strong mutagenecity in S. typhimurium TA98, but was higly decreased mutagenecity in S. typhimurium TA100. This result suggests that the mutagenecity of Trp P-1 can be mainly induced by the DNA lesions causing frame shift. Resveratrol itself did not show antibacterial effect upon 300 $\mu\textrm{g}$/assay. Resveratrol showed the strongest inhibitory effect with dose dependent manner on the mutagenicity induced by Trp P-1. The inhibition rates of resveratrol at concentration of 2, 10, 25, 50, 100, 300 $\mu\textrm{g}$/assay were 13%, 37%, 52%, 65%, 81%, 89%, respectively.

  • PDF

Biopharmaceutical Studies on Zipeprol Dihydrochloride Microcapsules (염산지페프를 마이크로캅셀에 관한 생물약제학적 연구)

  • Yong, Jae-Ick;Kim, Ock-Nam
    • Journal of Pharmaceutical Investigation
    • /
    • v.18 no.4
    • /
    • pp.187-195
    • /
    • 1988
  • Poorly permeable $Eudragit^{\circledR}$ RS 100 polymer was used as a wall material for the microencapsulation of zipeprol dihydrochloride by a phase separation method from chloroform-cyclohexane system with 5% polyisobutylene in cyclohexane, and microcapsules obtained were evaluated in vitro by particle size analysis, scanning electron microscopy, drug release test and in vivo bioavailability test in rats. The mechanism of drug release from microcapsules appeared to fit Higuchi matrix model kinetics. The area under the first moment of plasma concentration-time curve of the microcapsules obtained was considerably increased (p<0.05) as compared with that from zipeprol dihydrochloride oral solution. Therefore, it may be suggested that $Eudragit^{\cirledR}$ RS 100 coated zipeprol dihydrochloride microcapsules can be used as a sustained release medication.

  • PDF

Analysis of Contrast Medium Dilution Rate for changes in Tube Current and SOD, which are Parameters of Lower Limb Angiography Examination (하지 혈관조영검사 시 매개변수인 관전류와 SOD에 변화에 대한 조영제 희석률 분석)

  • Kong, Chang gi;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.603-612
    • /
    • 2020
  • This study has a purpose to look into the effect of the relationship between the Tube current (mA) and SOD(Source to Object Distance), which is a parameter of lower limb angiography examination, and the dilution rate of the contrast medium concentration (300, 320, 350) on the image. To that end, using 3 mm vessel model water phantom, a vessel model custom made in the size of peripheral vessel diameter, this study measured relationships between change of parameters, such as tube current (mA), SOD and varying concentrations (300, 320, 350) of contrast medium dilution into SNR and CNR values while analyzing the coefficients of variance(cv<10). The software used to measure SNR and CNR values was Image J 1.50i from NIH (National Institutes of Health, USA). MPV (mean pixel value) and SD (standard deviation) were used after verifying numerically the image signal for region of interest (ROI) and background on phantom from the DICOM (digital imaging and communications in medicine) 3.0 file transmitted to PACS. As to contrast medium dilution by the change of tube current, when 146 mA and 102 mA were compared, For both SNR and CNR, the coefficient of variation value was less than 10 until the section of CM: N/S dilution (100% ~ 30% : 70%) but CM: N/S dilution rate (20%: 80% ~ 10% : 90%) the coefficient of variation was 10 or more. As to contrast medium dilution by concentration for SOD change, when SOD's (32.5 cm and 22.5 cm) were compared,For both SNR and CNR, the coefficient of variation value was less than 10 until the section of CM: N/S dilution (100% ~ 30% : 70%) but CM: N/S dilution rate (20%: 80% ~ 10% : 90%) the coefficient of variation was 10 or more. As to contrast medium dilution by concentration for SOD change, when SOD's (32.5 cm and 12.5 cm) were compared,For both SNR and CNR, the coefficient of variation value was less than 10 until the section of CM: N/S dilution (100% ~ 30% : 70%) but CM: N/S dilution rate (20%: 80% ~ 10% : 90%) the coefficient of variation was 10 or more. As a result, set a low tube current value in other tests or procedures including peripheral angiography of the lower extremities in the intervention, and make the table as close as possible to the image receiver, and adjust the contrast agent concentration (300) to CM: N/S dilution (30%: 70%). ) Is suggested as the most efficient way to obtain images with an appropriate concentration while simultaneously reducing the burden on the kidney and the burden on exposure.