• Title/Summary/Keyword: and 100s

Search Result 18,199, Processing Time 0.062 seconds

A study of the plan dosimetic evaluation on the rectal cancer treatment (직장암 치료 시 치료계획에 따른 선량평가 연구)

  • Jeong, Hyun Hak;An, Beom Seok;Kim, Dae Il;Lee, Yang Hoon;Lee, Je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.171-178
    • /
    • 2016
  • Purpose : In order to minimize the dose of femoral head as an appropriate treatment plan for rectal cancer radiation therapy, we compare and evaluate the usefulness of 3-field 3D conformal radiation therapy(below 3fCRT), which is a universal treatment method, and 5-field 3D conformal radiation therapy(below 5fCRT), and Volumetric Modulated Arc Therapy (VMAT). Materials and Methods : The 10 cases of rectal cancer that treated with 21EX were enrolled. Those cases were planned by Eclipse(Ver. 10.0.42, Varian, USA), PRO3(Progressive Resolution Optimizer 10.0.28) and AAA(Anisotropic Analytic Algorithm Ver. 10.0.28). 3fCRT and 5fCRT plan has $0^{\circ}$, $270^{\circ}$, $90^{\circ}$ and $0^{\circ}$, $95^{\circ}$, $45^{\circ}$, $315^{\circ}$, $265^{\circ}$ gantry angle, respectively. VMAT plan parameters consisted of 15MV coplanar $360^{\circ}$ 1 arac. Treatment prescription was employed delivering 54Gy to recum in 30 fractions. To minimize the dose difference that shows up randomly on optimizing, VMAT plans were optimized and calculated twice, and normalized to the target V100%=95%. The indexes of evaluation are D of Both femoral head and aceta fossa, total MU, H.I.(Homogeneity index) and C.I.(Conformity index) of the PTV. All VMAT plans were verified by gamma test with portal dosimetry using EPID. Results : D of Rt. femoral head was 53.08 Gy, 50.27 Gy, and 30.92 Gy, respectively, in the order of 3fCRT, 5fCRT, and VMAT treatment plan. Likewise, Lt. Femoral head showed average 53.68 Gy, 51.01 Gy and 29.23 Gy in the same order. D of Rt. aceta fossa was 54.86 Gy, 52.40 Gy, 30.37 Gy, respectively, in the order of 3fCRT, 5fCRT, and VMAT treatment plan. Likewise, Lt. Femoral head showed average 53.68 Gy, 51.01 Gy and 29.23 Gy in the same order. The maximum dose of both femoral head and aceta fossa was higher in the order of 3fCRT, 5fCRT, and VMAT treatment plan. C.I. showed the lowest VMAT treatment plan with an average of 1.64, 1.48, and 0.99 in the order of 3fCRT, 5fCRT, and VMAT treatment plan. There was no significant difference on H.I. of the PTV among three plans. Total MU showed that the VMAT treatment plan used 124.4MU and 299MU more than the 3fCRT and 5fCRT treatment plan, respectively. IMRT verification gamma test results for the VMAT plan passed over 90.0% at 2mm/2%. Conclusion : In rectal cancer treatment, the VMAT plan was shown to be advantageous in most of the evaluation indexes compared to the 3D plan, and the dose of the femoral head was greatly reduced. However, because of practical limitations there may be a case where it is difficult to select a VMAT treatment plan. 5fCRT has the advantage of reducing the dose of the femoral head as compared to the existing 3fCRT, without regard to additional problems. Therefore, not only would it extend survival time but the quality of life in general, if hospitals improved radiation therapy efficiency by selecting the treatment plan in accordance with the hospital's situation.

  • PDF

SKU recommender system for retail stores that carry identical brands using collaborative filtering and hybrid filtering (협업 필터링 및 하이브리드 필터링을 이용한 동종 브랜드 판매 매장간(間) 취급 SKU 추천 시스템)

  • Joe, Denis Yongmin;Nam, Kihwan
    • Journal of Intelligence and Information Systems
    • /
    • v.23 no.4
    • /
    • pp.77-110
    • /
    • 2017
  • Recently, the diversification and individualization of consumption patterns through the web and mobile devices based on the Internet have been rapid. As this happens, the efficient operation of the offline store, which is a traditional distribution channel, has become more important. In order to raise both the sales and profits of stores, stores need to supply and sell the most attractive products to consumers in a timely manner. However, there is a lack of research on which SKUs, out of many products, can increase sales probability and reduce inventory costs. In particular, if a company sells products through multiple in-store stores across multiple locations, it would be helpful to increase sales and profitability of stores if SKUs appealing to customers are recommended. In this study, the recommender system (recommender system such as collaborative filtering and hybrid filtering), which has been used for personalization recommendation, is suggested by SKU recommendation method of a store unit of a distribution company that handles a homogeneous brand through a plurality of sales stores by country and region. We calculated the similarity of each store by using the purchase data of each store's handling items, filtering the collaboration according to the sales history of each store by each SKU, and finally recommending the individual SKU to the store. In addition, the store is classified into four clusters through PCA (Principal Component Analysis) and cluster analysis (Clustering) using the store profile data. The recommendation system is implemented by the hybrid filtering method that applies the collaborative filtering in each cluster and measured the performance of both methods based on actual sales data. Most of the existing recommendation systems have been studied by recommending items such as movies and music to the users. In practice, industrial applications have also become popular. In the meantime, there has been little research on recommending SKUs for each store by applying these recommendation systems, which have been mainly dealt with in the field of personalization services, to the store units of distributors handling similar brands. If the recommendation method of the existing recommendation methodology was 'the individual field', this study expanded the scope of the store beyond the individual domain through a plurality of sales stores by country and region and dealt with the store unit of the distribution company handling the same brand SKU while suggesting a recommendation method. In addition, if the existing recommendation system is limited to online, it is recommended to apply the data mining technique to develop an algorithm suitable for expanding to the store area rather than expanding the utilization range offline and analyzing based on the existing individual. The significance of the results of this study is that the personalization recommendation algorithm is applied to a plurality of sales outlets handling the same brand. A meaningful result is derived and a concrete methodology that can be constructed and used as a system for actual companies is proposed. It is also meaningful that this is the first attempt to expand the research area of the academic field related to the existing recommendation system, which was focused on the personalization domain, to a sales store of a company handling the same brand. From 05 to 03 in 2014, the number of stores' sales volume of the top 100 SKUs are limited to 52 SKUs by collaborative filtering and the hybrid filtering method SKU recommended. We compared the performance of the two recommendation methods by totaling the sales results. The reason for comparing the two recommendation methods is that the recommendation method of this study is defined as the reference model in which offline collaborative filtering is applied to demonstrate higher performance than the existing recommendation method. The results of this model are compared with the Hybrid filtering method, which is a model that reflects the characteristics of the offline store view. The proposed method showed a higher performance than the existing recommendation method. The proposed method was proved by using actual sales data of large Korean apparel companies. In this study, we propose a method to extend the recommendation system of the individual level to the group level and to efficiently approach it. In addition to the theoretical framework, which is of great value.

Clinical features of human metapneumovirus infection in children with acute respiratory tract infections (급성 호흡기 감염증 소아에서 Human metapneumovirus 감염의 임상 양상)

  • Lee, Jae Sook;Seo, Hyun Joo;Woo, Jeong Ju;Jang, Sung Hee;Lee, Jin A;Song, Mi Ok;Park, Hwa Young;Ahn, Young Min
    • Pediatric Infection and Vaccine
    • /
    • v.14 no.1
    • /
    • pp.75-82
    • /
    • 2007
  • Purpose : Human metapneumovirus (hMPV) is a newly identified paramyxovirus that causes a variety of clinical syndromes in children, including upper and lower respiratory tract illnesses. hMPV is considered an ubiquitous virus causing respiratory tract diseases among children especially during late winter and spring seasons. We report clinical features of human metapneumovirus infection in Korean children. Methods : hMPV infection was diagnosed by reverse transcriptase-polymerase chain reaction (RT-PCR) in respiratory specimens obtained from patients with acute respiratory tract infections from October, 2004 to May, 2005. Medical records of all hMPV-positive patients were reviewed, retrospectively. Results : A total of 15 hMPV were identified from 443 nasopharyngeal aspirations by RT-PCR (3.4%). The range of age of the patients with hMPV infection was from 1 month to 62 months (median age, 31.5 months), with similar numbers of females (8/15) and males (7/15). Among hMPV-positive children, 53.3% (8/15) were aged less than 24 months. Fever, cough, rhinorrhea, vomiting, diarrhea, tachypnea, and chest wall retractions were common findings. Most common clinical diagnosis was pneumonia (60%). Two of the 15 hMPV-positive patients were also positive for adenovirus. Fever persisted from 0 to 10 days (mean 4.9 days). The duration of hospitalization ranged from 4 to 7 days (mean 5.6 days). Conclusion : hMPV accounted for a small but significant proportion of respiratory tract infection in infants and children. Future development and application of diagnostic tools will determine the burden of disease caused by this newly discovered pathogen.

  • PDF

A COMPARATIVE STUDY OF PRESERVING ABILITY OF HUMAN PERIODONTAL LIGAMENT CELLS STORED IN DIFFERENT STORAGE MEDIA (수종의 저장용액에서 치주인대세포의 생존율 비교)

  • Choi, Won-Kyung;Choi, Hyung-Jun;Choi, Byung-Jai;Lee, Jong-Gap
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.2
    • /
    • pp.427-436
    • /
    • 1999
  • Preservation of the remaining periodontal ligament cells on an avulsed tooth is very important to the successful outcome of replantation. HBSS is recommended as the most suitable storage medium for the avulsed tooth that cannot be replanted immediately. But their availability near the site of an accident is doubtful. The purpose of this in vitro study was to compare periodontal ligament cells stored in different storage media obtained easily on the spot. Human periodontal ligament cells were collected from the premolar teeth extracted for orthodontic treatment. Cells were cultured in ${\alpha}-MEM$ culture medium containing 20% FBS, at $37^{\circ}C$ 100% humidity, in a 5% $CO_2$ incubator. Cells were cultured in 96 well culture plate, $5{\times}10^4$ cells per well with ${\alpha}-MEM$ and incubated for 24 hours. After discarding the medium, those cells were cultured in ${\alpha}-MEM$ contained with 10% FBS, pasteurized milk, sterilized saline, unstimulated saliva and bench-dried state at $25^{\circ}C$ room temperature for 30, 60, 90, 120, 180 minutes respectively. And then each group was measured using MTT assay. The results were as follows. 1. Between the group of each time, there was statistically significant difference. Periodontal ligament cells viability was highest in pasteurized milk and was reduced stepwisely in sterilized saline, unstimulated saliva and bench-dried state(p<0.05). 2. between the time of each group, there was statistically significant difference(p<0.05) but was no statistically significant difference at 90-120 minutes in pasteurized milk and at 60-90 minutes and 120-180 minutes in sterilized saline(p>0.05). In conclusion, HBSS as storage medium of an avulsed tooth is not practical on the spot. Insteadily pasteurized milk can be recommended to maintain the periodontal ligament cells viability.

  • PDF

Development of Robotic Inspection System over Bridge Superstructure (교량 상판 하부 안전점검 로봇개발)

  • Nam Soon-Sung;Jang Jung-Whan;Yang Kyung-Taek
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.180-185
    • /
    • 2003
  • The increase of traffic over a bridge has been emerged as one of the most severe problems in view of bridge maintenance, since the load effect caused by the vehicle passage over the bridge has brought out a long-term damage to bridge structure, and it is nearly impossible to maintain operational serviceability of bridge to user's satisfactory level without any concern on bridge maintenance at the phase of completion. Moreover, bridge maintenance operation should be performed by regular inspection over the bridge to prevent structural malfunction or unexpected accidents front breaking out by monitoring on cracks or deformations during service. Therefore, technical breakthrough related to this uninterested field of bridge maintenance leading the public to the turning point of recognition is desperately needed. This study has the aim of development on automated inspection system to lower surface of bridge superstructures to replace the conventional system of bridge inspection with the naked eye, where the monitoring staff is directly on board to refractive or other type of maintenance .vehicles, with which it is expected that we can solve the problems essentially where the results of inspection are varied to change with subjective manlier from monitoring staff, increase stabilities in safety during the inspection, and make contribution to construct data base by providing objective and quantitative data and materials through image processing method over data captured by cameras. By this system it is also expected that objective estimation over the right time of maintenance and reinforcement work will lead enormous decrease in maintenance cost.

  • PDF

Grain Yield Potential of a Low-Tillering Large Panicle Type in Rice (벼 소얼 수중형 초형의 수량성)

  • Kim, Je-Kyu;B.S., Vergara
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.37 no.4
    • /
    • pp.361-371
    • /
    • 1992
  • For the increase of grain yield potential in rice, a low-tillering large panicled type has been suggested as an ideotype. A low-tillering plant type may have different yield potential and needs different cultural practices from that used in a high-tillering type for the maximum yield. This study was conducted to evaluate the grain yield performances of a low-tillering large panicled rice and high-tillering small panicled rice at different plant spacings, nitrogen(N) levels and seedling numbers per hill. A low-tillering large panicled genotype, IR25588 was compared with a high-tillering small panicled IR58. The grain yield of IR25588 was significantly higher than that of IR58 under a narrow spacing with high N level. The maximum yields of IR58 and IR25588 were reached at about 35,000 and 40,000 spikelets per m$^2$, respectively. The increased grain yield in IR25588 was mainly due to the increase in spikelet number per unit area which is the most precise indicator of grain yield in rice. The optimum spacing for the maximum yield was denser for IR25588 than that for IR58 under high N level. The intra-hill competition of the low-tillering type was lower than that of the high-tillering type. The higher dry matter production and bigger leaf area and culm weight were the main factors for increased grain yield in a low-tillering panicle weight type. Based on the results, the yield potential of a low-tillering panicle weight type was higher than that of a high-tillering panicle number type, especially under a close spacing with high N level.

  • PDF

Modern approach of the discourse on viscera and bowels and retrogressive disorder (사상의학(四象醫學) 장부론(臟腑論)의 현대적 접근과 퇴행성질환의 조건)

  • Cho, Hwang-sung
    • Journal of Sasang Constitutional Medicine
    • /
    • v.12 no.1
    • /
    • pp.84-100
    • /
    • 2000
  • Are the body and th spirit to different things? How individual ability and feeling displays in a human being and what correation between the two lise physiologically? Namely, what determines the external and the internal world? By what physiological functions and circulations, it makes possible to indciate individual's characteristic? These kinds of questions in constitutional medicine is able us lead to the following approach.

  • PDF

Radiation Exposure on Radiation Workers of Nuclear Power Plants in Korea : 2009-2013 (국내 원전 종사자의 방사선량 : 2009-2013)

  • Lim, Young-khi
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.3
    • /
    • pp.162-167
    • /
    • 2015
  • Although the perfomance indicators of the nuclear power plants in Korea show optimal, it requires detailed analysis and discussion centered on the radiation dose. As analysis methods, analysis on the radiation dose of nuclear power plants over the past five years was assessed by comparing the relevant radiation dose of radiation workers and per capita average annual radiation dose of the world's major nuclear power stations was also analyzed. The radiation workers over the annual radiation dose limit of 50 mSv were not. The contrast ratio of the radiation exposure according to the reactor type was the normal operation of PHWR was 6.2% higher than those of the PWR. This shows the radiation work of PHWR during normal driving operation is much more than those of PWR. According to the Performance Indicators of the World Association of Nuclear Operator, the annual radiation dose per unit in 2013 showed 527 man-mSv of Korea is the best country among the major nuclear power generating states, the world average was 725 man-mSv. The annual per capita radiation dose is about 80% less than 1 mSv of the public dose limit and also the average per capita dose showed a very low level as 0.82 mSv. Workers in related organizations showed 1.07 mSv, the non-destructive inspection agency workers showed 3.87 mSv. The remarkable results were due to radiation reduced program such as development of radiation shielding and radiation protection. In conclusion, the radiation exposured dose of nuclear power plants workers in Korea showed a trend which is ideally reduced. But more are expected to be difficul and the psychological insecurity against the operation of the nuclear power plants is existed to the residents near the nuclear power plants. So the radiation dose reduction policy and radiation dose follow up study of nuclear power plants will be continously excuted.

Outcome of Prenatally Diagnosed Hydronephrosis - One Center Experience - (산전 진단된 수신증의 임상 경과 - 단일 기관의 경험 -)

  • Kim Yeun-Hee;Kim Byoung-Ju;Park Moon-Sung;Yang Jung-In;Kim Haeng-Soo;Kim Pyung-Kil;Pai Ki-Soo
    • Childhood Kidney Diseases
    • /
    • v.6 no.2
    • /
    • pp.178-187
    • /
    • 2002
  • Purpose : The detection of hydronephrosis(HN) with antenatal ultrasonography was first reported in the 1970s. Prenatal HN is diagnosed with an incidence of 1:100 to 1:500 on antenatal screening. Recently, the purpose of antenatal screening has changed from simple detection to selection for specific diagnosis-based management. this study is to evaluate the usefulness of antenatal sonography for HN and to investigate the differential causes of HN and their clinical outcomes. Patients and methods : 11,783 live neonates with prenatal ultrasonographic examination at Ajou University School of Medicine, from Sep. 1994 to Aug. 2001 were analyzed. Results and conclusion : Hydronephrosis (>10 mm) was detected in 119 (1.0%) cases antenatally and among these, 91 were proved to have HN postnatally Males were three times more affected than females. Additional imaging studies revealed that ureteropelvic junction obstruction was the most common postnatal diagnosis (47%), followed by multicystic dysplastic kidney, vesicoureteral junction obstruction and vesicoureteral reflux. During 20 months' follow-up(3 to 72 months), 58(48%) renal units showed spontaneous resolution and surgical interventions were necessary in 10 (7.4%) of postnatally confirmed hydronephrotic renal units.

  • PDF

Arthroscopic Repair of Type V SLAP lesion with Bio-knotless Anchor (제 5형 SLAP 병변에 대하여 Bio-knotless 봉합 나사못을 이용한 관절경적 봉합 수술의 임상적 결과)

  • Yum, Jae-Kwang;Lee, Sang-Lim;Ra, Ho-Jong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.11 no.1
    • /
    • pp.32-38
    • /
    • 2007
  • Purpose: This study reports the clinical results of the arthroscopic repair of type V SLAP lesion with bio-knotless anchor. Materials and Methods: 10 cases of 10 patients (10 male) were included in this study. The average age was 32.7 years old and the period from the first injury to operation was average 47.2 months. Preoperative Rowe score was average 37.5. Arthroscopic SLAP repair with 1 or 2 bio-knotless anchors were performed and arthroscopic Bankart repair with bio-knotless anchors were performed in all cases; 3 anchors were used in 7 cases and 2 anchors in 3 cases. The average follow up period was 15.7 months. Results: The Rowe score improved to 93 at last follow up period and 8 cases had full range of motion of the shoulder. 2 case had mild limited range of motion of the shoulder (one case; 170 degrees in flexion, 60 degrees in external rotation and T12 level in internal rotation, the other case; 160 degrees in flexion, 45 degrees in external rotation and T12 level in internal rotation.) without any problem in normal activity. Conclusion: Arthroscopic repair with bio-knotless anchor in type V SLAP lesion is one of the good methods because of the good clinical results.

  • PDF