• Title/Summary/Keyword: anchorage method

Search Result 200, Processing Time 0.032 seconds

Anchorage mechanism of inflatable steel pipe rockbolt depending on rock stiffness (팽창형 강관 록볼트의 암반 강성에 따른 정착 거동 특성)

  • Kim, Kyeong-Cheol;Kim, Ho-Jong;Jung, Young-Hoon;Shin, Jong-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.2
    • /
    • pp.249-263
    • /
    • 2017
  • The expansion behavior of inflatable steel pipe rockbolt shows geometric nonlinearity due to its ${\Omega}-shaped$ section. Previous studies on the anchoring behavior of inflatable steel pipe rockbolt were mainly performed using theoretical method. However, those studies oversimplified the actual behavior by assuming isotropic expansion of inflatable steel pipe rockbolt. In this study, the anchoring behavior of the inflatable steel pipe rockbolt were investigated by the numerical method considering the irregularity of pipe expansion and other influencing factors. The expansion of inflatable steel pipe rockbolt, the contact stress distribution and the change of the average contact stress and the contact area during installation were analyzed. The contact stresses were developed differently depending on the constitutive behavior of rocks. Small contact stresses occurred in steel pipes installed in elasto-plastic rock compared to steel pipes installed in elastic rock. Also, the anchoring behaviors of the inflatable steel pipe rockbolt were different according to the stiffness of the rock. The steel pipe was completely unfolded in the case of the stiffness smaller than 0.5 GPa, but it was not fully unfolded in the case of the stiffness larger than 0.5 GPa for the given analysis condition. When the steel pipe is completely unfolded, the contact stress increases as the rock stiffness increases. However, the contact stress decreases as the rock stiffness increases when the steel pipe is not fully expanded.

A Study on the Determinants Affecting Global Tramper Companies' Bunkering Port Selection Using AHP Method (AHP를 활용한 부정기선사의 벙커링 항만 선정요인에 대한 연구)

  • Ahn, Ji Young;Ryu, Hee Chan;Lee, Choong-bae
    • Journal of Korea Port Economic Association
    • /
    • v.38 no.3
    • /
    • pp.15-28
    • /
    • 2022
  • Bunkering refers to the supply of bunker fuel necessary for the ship operation, as well as minimizing the price and supply cost of fuel itself, and includes supplying good quality fuel oil in a timely manner and at the optimal port. Bunkering is an important criterion in terms of cost for shipping companies because bunkering involves a significant cost to the purchaser of bunkering from the time of initial purchase. This study aims to prioritize selection criteria for tramper companies to call port for bunkering. For this study, the variables were selected by analyzing the common criteria such as price, location, bunker quality and service and infrastructure etc. employed in previous studies. The AHP method was employed to prioritize the criteria in order. As a result of the analysis, the high level factors appeared in the order of price, location, bunkering quality and port service and infrastructure factors. The importance of price criterion and location criterion was found to be high. In the low level criterion of price, the bunker price per MT was ranked first in importance. In terms of location criteria, the location on the main trade route was high. In the low criteria of bunker quality and port service, the bunkering available types and bunker quality were found to be important factors, and in the low level criteria of infrastructure, anchorage and availability of bunkering during loading and discharging and port security factors were found to be important criteria. This study provides the guidelines for research designed to compare the bunkering port selection factors and to derive their importance suggesting the ways to enhance competitiveness as a bunkering port.

An Anatomical Study using CT Images for the Implantation of Micro-implants (CT 이미지를 사용한 Micro-implants 식립을 위한 매부학적 연구)

  • Park, Hyo-Sang
    • The korean journal of orthodontics
    • /
    • v.32 no.6 s.95
    • /
    • pp.435-441
    • /
    • 2002
  • Surgical microscrews were introduced and used as one method to provide absolute anchorage. Some clinicians implanted microscrews or miniscrews into the basal bone below the roots of the teeth to evade damage to the roots. Because the implanted microscrews were positioned too low the applied force was insufficient to retract the anterior teeth or protract the posterior teeth, and the use of microscrews or miniscrews seemed limited in applying vertical force. However Park implanted microscrews(micro-implants (1.2mm in diameter)) into the alveolar bone between the roots of the posterior teeth to change the direction of the applied force toward increasing horizontal component of the force. Moreover, these microscrew implants were positioned in the alveolar bone between the roots without causing discernable damage to the roots. This study was performed to provide guidelines and anatomic data to assist in the determination of the safe location for micro-implants. By measuring the CT images from 21 patients, anatomical data were obtained which were then used as a guide to determine the location for the implantation of micro-implants. The thickness of the cortical bones at the alveaolar bone region increased from the anterior to the posterior teeth area. The mandibular posterior teeth area showed thicker cortical bone. A greater distance was observed in distance between the second premolar root and first molar root in the upper arch, between the first molar root and the second molar root in the lower arch. The alveolar bone of the posterior teeth area is considered the best site for the implantation of micro-implants.

Code Change for using the High-Strength(550 MPa) Headed Deformed Bars of Large-Sized Diameter(57 mm) in Concrete Containments (대구경(57 mm) 및 고강도(550 MPa) 확대머리 철근의 콘크리트 격납구조물 적용을 위한 코드개정에 관한 연구)

  • Lee, Byung-Soo;Lim, Sang-Jun;Yun, Hyun-Do
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.147-161
    • /
    • 2017
  • Generally, significant amount of reinforcements are used in nuclear power plant structures and it may cause several potential problems during the construction. In particular, it is more difficult to pour concrete into structural member joint area than other areas because of the significant congestion of the joint area due to a lot of hooked bars, embedded materials, and other reinforcements. The purpose of this study is to solve these problems due to the reinforcement congestion by using the high-strength(ASTM A615 Gr.80) headed deformed bars of large-sized diameter(43 mm & 57 mm) in nuclear power plant structures as a alternative of standard hooked bars. In order to use headed deformed bars effectively, It is necessary to find the method how to relax limits on their use while maintaining or improving the anchorage capacity. Therefore, this study will analyze the results of tests planned to evaluate the influence of the restricted variables, such as bar size, yield strength, clear cover thickness.

Automatic Detection Approach of Ship using RADARSAT-1 Synthetic Aperture Radar

  • Yang, Chan-Su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.14 no.2
    • /
    • pp.163-168
    • /
    • 2008
  • Ship detection from satellite remote sensing is a crucial application for global monitoring for the purpose of protecting the marine environment and ensuring marine security. It permits to monitor sea traffic including fisheries, and to associate ships with oil discharge. An automatic ship detection approach for RADARSAT Fine Synthetic Aperture Radar (SAR) image is described and assessed using in situ ship validation information collected during field experiments conducted on August 6, 2004. Ship detection algorithms developed here consist of five stages: calibration, land masking, prescreening, point positioning, and discrimination. The fine image was acquired of Ulsan Port, located in southeast Korea, and during the acquisition, wind speeds between 0 m/s and 0.4 m/s were reported. The detection approach is applied to anchoring ships in the anchorage area of the port and its results are compared with validation data based on Vessel Traffic Service (VTS) radar. Our analysis for anchoring ships, above 68 m in length (LOA), indicates a 100% ship detection rate for the RADARSAT single beam mode. It is shown that the ship detection performance of SAR for smaller ships like barge could be higher than the land-based radar. The proposed method is also applied to estimate the ship's dimensions of length and breadth from SAR radar cross section(RCS), but those values were comparatively higher than the actual sizes because of layover and shadow effects of SAR.

  • PDF

THE EFFECT OF LIGATION METHOD ON THE FRICTIONAL FORGE BETWEEN ORTHODONTIC BRACKET AND ARCHWIRE (결찰양식이 교정용 브라켓과 교정선 사이의 마찰력에 미치는 영향)

  • Shin, Hyun-Jeong;Kwon, Oh-Won;Kim, Kyo-Han
    • The korean journal of orthodontics
    • /
    • v.28 no.5 s.70
    • /
    • pp.813-823
    • /
    • 1998
  • The frictional force has been considered as an harmful factor in an active unit where tooth movement occurs, but as an advantageous factor in anchor unit that resist tooth movement. That is, efficient tooth movement is planned by using ligation methods that have low levels of bracket-wire frictional force and the anchorage control can be achieved by using ligation methods that have high levels of bracket-wire frictional force that result in binding of the bracket accompanied by little or no tooth movement. The purpose of this study was to evaluate the frictional force generated between bracket and wire in accordance with the methods of ligation, the material of ligation and the passage of time under artificial saliva. Tested were 0.017x0.022 inch stainless steel wires in standard edgewise twin brackets for upper central incisors in a 0.018-inch slot. The wires were ligated into the brackets with elastomeric modules and stainless steel ligatures. Whole tie, half tie, twisting tie and double overlay tie were done with elastomeric modules. With 0.009-inch stainless steel ligature whole tie and half tie were done by needle holder and whole tie by ligature tying plier. With 0.012-inch stainless steel ligature whole ties were done by needle holder. Whole tie groups of elastomeric module were kept in artificial saliva bath at $37^{\circ}C$ for 28 days. The frictional force was recorded by means of an Instron universial testing instrument (4202 INSTRON, Instron Co., U.S.A.) at initial, 7, 14, 21, and 28 days. The results for ligated samples in a simulated oral environment revealed the fellowing : ${\cdot}$In elastomeric module whole tie, 28 days group was significantly greater mean static frictional force than any other group but there were no significant differences among any other group (p>0.05). ${\cdot}$Elastomeric module twisting ties were significantly greater mean static frictional forces than any other ligation method but there were no significant differences between twisting tie and double overlay tie (p>0.05). Twisting tie, double overlay tie, whole tie, half tie showed differences in decreasing order. ${\cdot}$Stainless steel half tie produced lower mean static frictional force than whole tie, ligation by ligature tying plier produced greater mean static frictional force than by needle holder and ligation with 0.012-inch stainless steel ligature produced greater mean static frictional force than with 0.009-inch stainless steel ligature (p<0.05). ${\cdot}$There were no significant differences between the mean static frictional forces of elastomeric whole tie and stainless steel whole tie (p>0.05).

  • PDF

Three-dimensional finite element analysis of initial tooth displacement according to force application point during maxillary six anterior teeth retraction using skeletal anchorage (골격성 고정원을 이용한 상악 6전치 후방 견인시 힘의 적용점 변화에 따른 치아 이동 양상에 관한 유한 요소법적 분석)

  • Kim, Chan-Nyeon;Sung, Jae-Hyun;Kyung, Hee-Moon
    • The korean journal of orthodontics
    • /
    • v.33 no.5 s.100
    • /
    • pp.339-350
    • /
    • 2003
  • The purpose of this study was to investigate the micro-implant height and anterior hook height to prevent maxillary six anterior teeth from lingual tipping and extruding during space closure. We manufactured maxillary dental arch form, bracket and wire, using the computer aided three-dimensional finite element method. Bracket was $.022'{\times}.028'$ slot size and attached to tooth surface. Wire was $.019'{\times}.025'$ stainless steel and $.032'{\times}.032'$ stainless steel hook was attached to wire between lateral incisor and canine. Length of hook was 8mm and force application points were marked at intervals of In. Four micro-implants were implanted on alveolar bone between second premolar and first molar. The heights of them were 4, 6, 8, 10mm starting from wire. We analyzed initial displacement of teeth by various force application point applying force of 150gm to each micro-implant and anterior hook. The conclusions of 4his study are as the following : 1. When the micro-implant height was 4m and the anterior hook height was 5mm and below, anterior teeth were tipped lingually. When the anterior hook height was 6mm and above, anterior teeth were tipped labially. 2. When the micro-implant height was 6mm and the anterior hook height was 6mm and below, the anterior teeth were tipped lingually. When the anterior hook height was 6m and above, the anterior teeth were tipped labially. But lingual tipping of anterior teeth decreased and labial tipping Increased when the micro-implant height was 6mm, compared with 4mm micro-implant height. 3. When the micro-implant height was 8mm and the anterior hook height was 2mm, the anterior teeth were tipped lingually. When the anterior hook height was 3mm and above, labial tipping movement of the anterior teeth increased proportionally. 4. When the micro-implant height was 10mm and the anterior hook height was 2mm and above, labial tipping of the anterior teeth increased proportionally. 5. As the anterior hook height increased, aterior teeth were tipped more labially. But extrusion occurred on canine and premolar area because of the increase of wire distortion. 6. Movement of the posterior teeth was tipped distally during maxillary six anterior teeth retraction using micro-im plant because of the friction between bracket and were Based on the results of this study, we could predict the pattern of the tooth movement according to position of micro-implant and height of anterior hook. It seems that we can find the force application point for proper tooth movement in consideration of inclination of anterior anterior teeth, periodontal condition, overjet and overbite

The pattern of movement and stress distribution during retraction of maxillary incisors using a 3-D finite element method (상악 전치부 후방 견인 시 이동 양상과 응력 분포에 관한 삼차원 유한요소법적 연구)

  • Chung, Ae-Jin;Kim, Un-Su;Lee, Soo-Haeng;Kang, Seong-Soo;Choi, Hee-In;Jo, Jin-Hyung;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.37 no.2 s.121
    • /
    • pp.98-113
    • /
    • 2007
  • Objective: The purpose of this study was to evaluate the displacement pattern and the stress distribution shown on a finite element model 3-D visualization of a dry human skull using CT during the retraction of upper anterior teeth. Methods: Experimental groups were differentiated into 8 groups according to corticotomy, anchorage (buccal: mini implant between the maxillary second premolar and first molar and second premolar reinforced with a mini Implant, palatal: mini implant between the maxillary first molar and second molar and mini implant on the midpalatal suture) and force application point (use of a power arm or not). Results: In cases where anterior teeth were retracted by a conventional T-loop arch wire, the anterior teeth tipped more postero-inferiorly and the posterior teeth moved slightly in a mesial direction. In cases where anterior teeth were retracted with corticotomy, the stress at the anterior bone segment was distributed widely and showed a smaller degree of tipping movement of the anterior teeth, but with a greater amount of displacement. In cases where anterior teeth were retracted from the buccal side with force applied to the mini implant placed between the maxillary second premolar and the first molar to the canine power arm, it showed that a smaller degree of tipping movement was generated than when force was applied to the second premolar reinforced with a mini implant from the canine bracket. In cases where anterior teeth were retracted from the palatal side with force applied to the mini implant on the midpalatal suture, it resulted in a greater degree of tipping movement than when force was applied to the mini implant between the maxillary first and second molars. Conclusion: The results of this study verifies the effects of corticotomies and the effects of controlling orthodontic force vectors during tooth movement.

TIMP-2 Gene Transfer Via Adenovirus Inhibits the Invasion of Lung Cancer Cell (TIMP-2 유전자 재조합 아데노바이러스의 폐암세포 침윤 억제 효과)

  • Oh, Yeon-Mok;Lee, Jae-Ho;Yoo, Chul-Gyu;Chung, Hee-Soon;Kim, Young-Whan;Han, Sung-Koo;Shim, Young-Soo;Lee, Choon-Taek
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.2
    • /
    • pp.189-197
    • /
    • 2000
  • Background : Tissue inhibitor of metalloproteinase is a natural inhibitor that counteracts pro teolytic enzymes essential to the invasion of cancer cell. Whether or not TIMP-2 gene transfer via adenovirus could inhibit the invasion of lung cancer cell iη vitro was evaluated for the future purpose of gene therapy against lung cancer. Methods : Recombinant adenovirus-TIMP-2(Ad-TIMP-2) was generated by homologous recombination after pACCMV-TIMP-2 and pJM17 were cotransfected into 293 cell by standard calcium phosphate coprecipitate method. Calu-6, one of the most invasive lung cancer cells, was transduced with Ad-TIMP-2 or Ad-$\beta$gal. Anchorage-independent growth and invasiveness were assessed by soft agar clonogenicity assay and invasion assay using two-chamber, well divided by matrigel. Results : Ad-TIMP-2 transduced calu-6 cells produced biologically active TIMP-2 more than 50 times more than parental calu-6. TIMP-2 gene transfer did not suppress the in vitro tumorigenicity. However, two chamber well assay revealed that Ad-TIMP-2 transduction reduced the invasiveness of calu-6 efficiently (12% compared with parental cell) even at low 10moi. Conclusion : Even though TIMP-2 gene transfer did not inhibit in vitro tumorigenicity, it did inhibit invasion of lung cancer cell in vitro. The inhibition of invasion by Ad-TIMP-2 may be a useful strategy for the treatment of lung cancer.

  • PDF

A Study on Evaluating the Possibility of Monitoring Ships of CAS500-1 Images Based on YOLO Algorithm: A Case Study of a Busan New Port and an Oakland Port in California (YOLO 알고리즘 기반 국토위성영상의 선박 모니터링 가능성 평가 연구: 부산 신항과 캘리포니아 오클랜드항을 대상으로)

  • Park, Sangchul;Park, Yeongbin;Jang, Soyeong;Kim, Tae-Ho
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_1
    • /
    • pp.1463-1478
    • /
    • 2022
  • Maritime transport accounts for 99.7% of the exports and imports of the Republic of Korea; therefore, developing a vessel monitoring system for efficient operation is of significant interest. Several studies have focused on tracking and monitoring vessel movements based on automatic identification system (AIS) data; however, ships without AIS have limited monitoring and tracking ability. High-resolution optical satellite images can provide the missing layer of information in AIS-based monitoring systems because they can identify non-AIS vessels and small ships over a wide range. Therefore, it is necessary to investigate vessel monitoring and small vessel classification systems using high-resolution optical satellite images. This study examined the possibility of developing ship monitoring systems using Compact Advanced Satellite 500-1 (CAS500-1) satellite images by first training a deep learning model using satellite image data and then performing detection in other images. To determine the effectiveness of the proposed method, the learning data was acquired from ships in the Yellow Sea and its major ports, and the detection model was established using the You Only Look Once (YOLO) algorithm. The ship detection performance was evaluated for a domestic and an international port. The results obtained using the detection model in ships in the anchorage and berth areas were compared with the ship classification information obtained using AIS, and an accuracy of 85.5% and 70% was achieved using domestic and international classification models, respectively. The results indicate that high-resolution satellite images can be used in mooring ships for vessel monitoring. The developed approach can potentially be used in vessel tracking and monitoring systems at major ports around the world if the accuracy of the detection model is improved through continuous learning data construction.