• Title/Summary/Keyword: anatomical

Search Result 2,923, Processing Time 0.03 seconds

Clinical Application of 11C-Acetate Positron Emission Tomography-Computed Tomography (PET-CT) in Patients of Urinary System Cancer (비뇨기암 환자에서 11C-Acetate 양전자 방출 컴퓨터 단층 검사 (PET-CT)의 임상 적용)

  • Nam-Koong, Hyuk;Ham, Joon chul;Kim, Sang kyoo;Choi, Yong hoon;Lim, Han sang;Kim, Jae sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.9-13
    • /
    • 2016
  • Purpose PET-CT examinations using $^{18}F-FDG$ to treat urinary system cancer are limited in terms of anatomical structure and excretion route of $^{18}F-FDG$. But one of the ongoing examinations utilizing $^{11}C-Acetate$ can compensate for such defects. We would like to introduce a clinical application of $^{11}C-Acetate$ PET-CT in urinary cancer patients. Materials and Methods We conducted a clinical survey of 22 patients diagnosed with urinary cancer at our hospital, 10 prostate cancer patients, 10 renal cell carcinoma patients, and 2 bladder cancer patients. All patients were performed $^{18}F-FDG$ PET-CT examinations, $^{11}C-Acetate$ examinations were performed after two weeks on average. The equipment used to D-710 PET-CT in GE Company and we performed PET-CT procedures 15 minutes after injecting $^{11}C-Acetate$, and a medical doctor from the department of nuclear medicine appraised and compared images between $^{18}F-FDG$ and $^{11}C-Acetate$. Results According to our survey, prostate cancer patients generally had lower uptake of $^{18}F-FDG$ than other cancer patients did. In 2 out of 10 prostate cancer patients, metastasized cancer showed greater uptake in $^{11}C-Acetate$ than $^{18}F-FDG$. In renal cell carcinoma cases, 8 out of 10 patients displayed evidently greater uptake in $^{11}C-Acetate$ than $^{18}F-FDG$. We excluded bladder cancer cases in this study because uptake of $^{18}F-FDG$ in the bladder was too hot, the number of patients was insufficient, and the cases did not meet criteria such as the use of diuretics. Conclusion It is too premature to draw solid conclusions from the survey, since it involved only a small number of participants. However, there are a number of studies conducted abroad that prove the effectiveness of the $^{11}C-Acetate$ PET-CT examinations in treating urinary system cancer, and this study is still ongoing at our hospital. If the tests were to be conducted on a larger number of participants, this study could lead to numerous other potential research topics, such as the correlation between Prostatic specific antigen (PSA) values and $^{11}C-Acetate$ PET-CT, Gleason sum values from biopsy before surgery, Specificity, sensitivity, positive predictive value (PPV), negative predictive value (NPV) between $^{18}F-FDG$ PET-CT examinations and $^{11}C-Acetate$ PET-CT examinations in other urinary system cancers.

  • PDF

Evaluation of the combination of Bone Scan Image and Pelvic X-ray Image (뼈 검사 영상과 골반 X선 영상의 결합 유용성 평가)

  • Lee, Choong Woon;You, Yeon Wook;Kim, Yong Keun;Weon, Woo Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.23-27
    • /
    • 2018
  • Purpose The introduction of bone scan has been reported as a useful tool in the diagnosis, treatment, and treatment response of skeletal disease. The purpose of this study is to improve the anatomical information and tolerance of the bone by combining bone scan and pelvic X-ray without additional radiation exposure. Materials and Methods From November 2015 to August 2016, 236 patients(64 men and 172 women, average age $50.96{\pm}15.39years$) take Bone scan and Pelvis AP(Anteroposterior) X-ray scan at the National Cancer Center. The scan equipment was a gamma camera, Symbia Ecam (SIEMENS, Germany), and a digital x-ray, DRS-800 (Listem, Korea). Osirix version 3.8.1 (Osirix, USA) and Stata/SE version 14.0 (StataCorp, USA) were used for image combination and analysis. The patient was intravenously injected with $^{99m}Tc-DPD$ (740 MBq), and the scan was performed 2 to 4 hours later. Gamma camera image acquisition were Matrix size $256{\times}1024$, Zoom 1.00, and scan speed 17 cm/min. The digital X-ray was made with a collimator size of $14^{{\prime}{\prime}}{\times}17^{{\prime}{\prime}}$, 77 kVp (60 to 97 kVp) and an average of 30 mAs (20 to 48). ASIS and pubic symphysis Select virtual points then Combine three virtual points and pelvic contour lines. The acquired images were evaluated by three radiologists who worked for more than 5 years in the nuclear medicine department. Results Of the total 236 patients, 216 (91.53%) were matched. The median and range (min~max) of the age were 67 (46~81) years old in the unmatched group and 52 (22~87) years old in the matched group, The Wilcoxon rank-sum test was performed to determine whether age was different between the two groups. As a result, the age difference between the two groups was statistically significant at p < 0.0001. Of the 64 men, 60 (93.75%) were match and of the 172 women, 156 (93.75%) were match. There was no statistically significant difference according to gender(p = 0.4542). Of the 54 patients without pelvic lesions, 54 (100.00%) were match, and 162 (89.01%) of 182 patients with pelvic lesions were match. There was a statistically significant difference according to the presence of pelvic lesions. Conclusion There are many variables in the combination of bone scan and pelvic X-ray imaging, and the patient's age and pelvic lesion may have some effect on the image combination. This study is expected to be useful for the diagnosis of pelvic osteosarcoma of children without radiation exposure. It is expected that this combination of images will help to develop the nuclear medicine image.

Determination of Appropriate Exposure Angles for the Reverse Water's View using a Head Phantom (두부 팬텀을 이용한 Reverse Water's View에 관한 적절한 촬영 각도 분석)

  • Lee, Min-Su;Lee, Keun-Ohk;Choi, Jae-Ho;Jung, Jae-Hong
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.187-195
    • /
    • 2017
  • Early diagnosis for upper facial trauma is difficult by using the standard Water's view (S-Water's) in general radiograph due to overlapping of anatomical structures, the uncertainty of patient positioning, and specific patients with obese, pediatric, old, or high-risk. The purpose of this study was to analyze appropriate exposure angles through a comparison of two different protocols (S-Water's vs. reverse Water's view (R-Water's)) by using a head phantom. A head phantom and general radiograph with 75 kVp, 400 mA, 45 ms 18 mAs, and SID 100 cm. Images of R-Water's were obtained by different angles in the range of $0^{\circ}$ to $50^{\circ}$, which adjusted an angle at 1 degree interval in supine position. Survey elements were developed and three observers were evaluated with four elements including the maxillary sinus, zygomatic arch, petrous ridge, and image distortion. Statistical significant analysis were used the Krippendorff's alpha and Fleiss' kappa. The intra-class correlation (ICC) coefficient for three observers were high with maxillary, 0.957 (0.903, 0.995); zygomatic arch, 0.939 (0.866, 0.987); petrous ridge, 0.972 (0.897, 1.000); and image distortion, 0.949 (0.830, 1.000). The high-quality image (HI) and perfect agreement (PA) for acquired exposure angles were high in range of the maxillary sinus ($36^{\circ}-44^{\circ}C$), zygomatic arch ($33^{\circ}-40^{\circ}$), petrous ridge ($32^{\circ}-50^{\circ}$), and image distortion ($44^{\circ}-50^{\circ}$). Consequently, an appropriate exposure angles for the R-Water's view in the supine position for patients with facial trauma are in the from $36^{\circ}$ to $40^{\circ}$ in this phantom study. The results of this study will be helpful for the rapid diagnosis of facial fractures by simple radiography.

Analysis of golf swing motion for specific properties of club shaft (클럽 샤프트(Club Shaft) 특성에 따른 골프 스윙(Golf Swing)동작 분석)

  • Kim, Sung-Il;Kim, Ky-Hyoung;Kim, Hyung-Soo;Lee, Hyun-Seob;Kim, Jin-Uk;Ahn, Chan-Gyu;Kim, Hee-Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.17-32
    • /
    • 2002
  • The purpose of this study was to find the rational method to analyze golf swing with specific property of club shaft. Three subjects were filmed by two high speed digital cameras with 500 fps. The phase analyzed was downswing of each subject. The three-dimensional coordinates of the anatomical landmarks were obtained with motion analysis system Kwon3d 3.0 version and smoothed by lowpass digital filter with cutoff frequency 6Hz. From these data, kinematic and kinetic variables were calculated using Matlab(ver 5.0) The variables for this study were angular velocity and accelerations, which were calculated and following conclusions have been made : 1) Golf swing time of stiff club is faster than that of regular club. 2) In shoulder joint motion of swing with the stiff club, x-stiff showed mort rapid negative acceleration than that of regular club. 3) In regular club, the velocity of club head would be more effective velocity, which was increasing, than those of other clubs before impact. 4) In wrist joint motion of swing with stiff club, x-stiff club showed faster than regular club in the downswing and impact more rapid negative acceleration.

Patient Setup Aid with Wireless CCTV System in Radiation Therapy (무선 CCTV 시스템을 이용한 환자 고정 보조기술의 개발)

  • Park, Yang-Kyun;Ha, Sung-Whan;Ye, Sung-Joon;Cho, Woong;Park, Jong-Min;Park, Suk-Won;Huh, Soon-Nyung
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.300-308
    • /
    • 2006
  • $\underline{Purpose}$: To develop a wireless CCTV system in semi-beam's eye view (BEV) to monitor daily patient setup in radiation therapy. $\underline{Materials\;and\;Methods}$: In order to get patient images in semi-BEV, CCTV cameras are installed in a custom-made acrylic applicator below the treatment head of a linear accelerator. The images from the cameras are transmitted via radio frequency signal (${\sim}2.4\;GHz$ and 10 mW RF output). An expected problem with this system is radio frequency interference, which is solved utilizing RF shielding with Cu foils and median filtering software. The images are analyzed by our custom-made software. In the software, three anatomical landmarks in the patient surface are indicated by a user, then automatically the 3 dimensional structures are obtained and registered by utilizing a localization procedure consisting mainly of stereo matching algorithm and Gauss-Newton optimization. This algorithm is applied to phantom images to investigate the setup accuracy. Respiratory gating system is also researched with real-time image processing. A line-laser marker projected on a patient's surface is extracted by binary image processing and the breath pattern is calculated and displayed in real-time. $\underline{Results}$: More than 80% of the camera noises from the linear accelerator are eliminated by wrapping the camera with copper foils. The accuracy of the localization procedure is found to be on the order of $1.5{\pm}0.7\;mm$ with a point phantom and sub-millimeters and degrees with a custom-made head/neck phantom. With line-laser marker, real-time respiratory monitoring is possible in the delay time of ${\sim}0.17\;sec$. $\underline{Conclusion}$: The wireless CCTV camera system is the novel tool which can monitor daily patient setups. The feasibility of respiratory gating system with the wireless CCTV is hopeful.

Long-term Results of Surgical Correction for Partial Atrioventricular Septal Defects -Seventeen-year Experience - (부분방실중격결손증에 대한 외과적 교정의 장기 결과)

  • 이정렬;박천수;임홍국;김용진;노준량;배은정;노정일;윤용수
    • Journal of Chest Surgery
    • /
    • v.36 no.12
    • /
    • pp.911-920
    • /
    • 2003
  • In this study, we analyzed the long-term surgical outcome of partial atrioventricular septal defects during the past 17 years at Seoul National University Hospital. Material and Method: A retrospective analysis on mortality, survival, and reoperation and their risk factors was done in 93 patients who underwent surgical correction of partial atrioventricular septal defects between April 1986 and December 2002. 32 patients were male and 61 were female with a median age of 68 months (3∼818 months) and a mean follow-up period of 108 months (1∼200 months). Result: There were 4 operative deaths (4.3%) and one mortality during the follow-up period. 3, 5, 10, and 15 year actuarial survival rates were 95.7%, 94.3%, 94,3%, and 94.3%, respectively. After the surgical correction, left atrioventricular valve Incompetence was improved in 61patients (67.7%), remained same as the preoperative status in 14 patients (15.1%), and was aggravated in 12 patients (12.9%). Reoperation was performed in 8 patients (9.0%) after a mean interval of 38.6 months (3∼136 months). Freedom from reoperation rates at 3, 5, 10, and 15 years after surgical correction were 94.0%, 91.4%, 91.4%, and 88,2%, respectively Reasons for reoperation were 7 left atrioventricular valve incompetence, 2 left ventricular outflow tract obstruction, a residual atrial septal defect, a left atrioventricular valve stenosis, and a right ventricular failure. Left ventricular outflow tract obstruction was the only statistically significant factor. In ten patients, significant arrhythmia was developed and three of them were supraventricular arrhythmia. Complete atrioventricular block occurred in 7 patients and permanent pacemakers were implanted in six of them. Conclusion: Surgical corrections of partial atrioventricular septal defects were performed with low operative mortality. Since left atrioventricular valve incompetence was the most common cause of reoperation and left ventricular outflow tract obstruction was the only risk factor for reoperation, a precise estimation of the left atrioventricular valve morphology and the structure of left ventricular outflow tract are needed. Although left ventricular outflow tract obstruction rarely developed, reoperation was frequently required and resection of subaortic tissue could be peformed but the possibility of recurrence was high, so modified Konno operation could be performed with satisfactory results. Complete atrioventricular block developed frequently in early periods, but was overcome with a precise anatomical understanding of conduction system and experience.

Excretroy Urography in the Minipig (미니돼지에서 배설성요로조영술의 적용)

  • Jung, Joo-Hyun;Chang, Jin-Hwa;Choi, Min-Cheol
    • Journal of Life Science
    • /
    • v.17 no.9 s.89
    • /
    • pp.1211-1216
    • /
    • 2007
  • Excretory urography was performed on eight healthy minipigs to evaluate radiographic anatomical status and excretive function of the urinary tracts and to get an optimal procedure. The right and left kidneys were located in $T13{\sim}L4$and $T12{\sim}L3.5$, respectively. The left kidneys were located more cra-nially than the right. The everage lengths and widths of kidneys were $8.50{\pm}0.58$ $(mean{\pm}SD)$and $4.30{\pm}0.39$ cm on the ventrodorsal projection and $8.70{\pm}0.76$, and $4.10{\pm}0.40$ cm on the lateral projection, respectively. The lengths of kidneys were twice the width. When the lengths of kidneys were com-pared with lengths of the second lumbar vertebras, the ratios of kidney lengths to L2 lengths were $3.62{\pm}0.30$ on the ventrodorsal projection and $3.63{\pm}1.10$ on the lateral projection. The lengths and 쟝손 of renal pelvis including major calices were $4.01{\pm}0.46$, and 2.20{\pm}0.41$ cm, respectively. The lengths and 쟝손 of minor calices were $0.49{\pm}0.06$, and $0.10{\pm}0.01$ cm. The lengths and widths of the ureters were $12.25{\pm}2.05$, and 2.94{\pm}0.86$ cm. The nephrogram stage was reached in 3{\sim}5$ minutes, and the pyelogram phase in $5{\sim}15$ minutes individually after injection of contrast medium. The result of this study shows similar information and procedure of excretory urography for other laboratory ani-mals and leads to the potential use of this method for minipigs.

On the manufacturing of WPC (Wood Plastic Composites) with Heat-Catalyst Polymerization (I) - On the characteristics of composites made from monomer Methyl MethacryIate and several commercial woods in Korea (가열(加熱)·촉매중합법(觸媒重合法)에 의한 목재(木材)·고분자복합체(高分子複合體) 제조(製造)(I) - MMA에 의한 한국산(韓國産) 주요목재(主要木材)의 복합체특성(複合體特性))

  • Cho, Nam-Seok;Jo, Jae-Myeong;Ahn, Won-Yong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.2 no.3
    • /
    • pp.3-16
    • /
    • 1974
  • One of the disadvantages of. wood and wood products is their hydroscopicity or dimensional instability. This is responsible for the loss of green volume of lumber as seasoning degrade. Dimensional stabilization is needed to substantially reduce seasoning defects and degrades and for increasing the serviceability of wood products. Recently, considerable world-wide attention has been drawn to the so-called Wood-Plastic Composites by irradiation-and heat-catalyst-polymerization methods and many research and developmental works have been reported. Wood-Plastic Composites are the new products having the superior mechanical and physical properties and the combinated characteristics of wood and plastic. The purpose of this experiment was to obtain the basic data for the improvement of wooden materials by manufacturing WPC. The species examined were Mulpurae-Namoo (Fraxinus, rhynchophylla), Sea-Namoo (Carpinus laxiflora), Cheungcheung-Namoo (Cornus controversa), Gorosae-Namoo (Acermono), Karae-Namoo(Juglans mandshurica) and Sanbud-Namoo (Prunus sargentii), used as blocks of type A ($3{\times}3{\times}40cm$) and type B ($5{\times}5{\times}60cm$), and were conditioned to about 10~11% moisture content before impregnation in materials humidity control room. Methyl methacrylate (MMA) as monomer and benzoyl peroxide (BPO) as initiator are used. The monomer containing BPO was impregnated into wood pieces in the vacuum system. After impregnation, the treated samples were polymerized with heat-catalyst methods. The immersed weights of monomer in woods are directly proportionated to the impregnation times. Monomer impregnation properties of Cheungcheung-Namoo, Mulpurae-Namoo and Seo-Namoo are relatively good, but in Karae-Namoo, it is very difficult to impregnate the monomer MMA. Fig. 3 shows the linear relation between polymer retentions in wood and polymerization times; that is, the polymer loadings are increasing with polymerization times. Furthermore species, moisture content, specific gravity and anatomical or conductible structure of wood, bulking solvents and monomers etc have effects on both of impregnation of monomer and polymer retention. Physical properties of treated materials are shown in table 3. Increasing rates of specific gravity are ranged 3 to 24% and volume swelling 3 to 10%. ASE is 20 to 46%, AE 14 to 50% and RWA 18 to 40%. Especially, the ASE in relation to absorption of liquid water increases approximately with increase of polymer content, although the bulking effect of the polymerization of monomer may also be influential. WPCs from Mulpurae-Namoo and Cheungcheung-Namoo have high dimensional stability, while its of Karae-Namoo and Seo-Namoo are-very low. Table 4 shows the mechanical properties of WPCs from 6 species. With its specific gravity and polymer loading increase, all mechanical properties are on the increase. Increasing rate of bending strength is 10 to 40%, compression strength 25 to 70%, ;impact bending absorbed energy 4 to 74% and tensile strength 18 to 56%. Mulpurae-Namoo and Cheungcheung-Namoo with high polymer content have considerable high increasing rate of strengths. But incase of Karae-Namoo with inferior monomer impregnation it is very low. Polymer retention in cell wall is 0.32 to 0.70%. Most of the polymer is accumulated in cell lumen. Effective. of polymer retention is 58.59% for Mulpurae-Namoo, 26.27% for Seo-Namoo, 47.98% for Cheungcheung-Namoo, 25.64% for Korosae-Namoo, 9.96% for Karae-Namoo and 25.84% for Sanbud-Namoo.

  • PDF

Reconstruction of Anterior Cruciate Ligament in Adolescent (청소년기에 시행한 전방십자인대 재건술)

  • Song Eun Kyoo;Shim Sang Don;Kim Hyung Jong;Kim Hyung Won
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.2
    • /
    • pp.101-108
    • /
    • 2002
  • Purpose: To evaluate the clinical results of anterior cruciate ligament (ACL) reconstruction and to know the results of physeal injury by transphyseal tunnel in adolescents who had remaining growth potential. Materials and Methods : This study involved 12 patients under 19 years old out of 445 patients, who underwent ACL reconstruction between 1993 and 2001. The mean age at the time of operation was 15.9 $(13.1\~16.9)$ years and fellow-up period was 45.1 $(24\~120.6)$ months in avrarge. Autologous quadrupled hamstring tendon was used as graft in 11 cases and bone-patellar tendon-bone in 1 case. Clinical results were evaluated by Lysholm Knee Scoring Scale, range of motion and return to preinjury sports activities. Radiologic results were evaluated by $Telos^{\circledR}$ device. Bone maturity were analyzed by chronological age, standing height and the width of growth plate in AP and lateral view of knee joint at preoperatively. The growth disturbances were evaluated by measuring femorotibial angle, anatomical and mechanical lateral distal femoral angle, mechanical medial proximal tibial angle and leg length and by comparing those of uninjured site in last follow-up teleoroentgenogram. Results : The mean Lysholm Knee score was 51 $(25\~63)$points preoperatively and 98 $(94\~100)$ points at last follow up. The mean anterior displacement of the tibia by using $Telos^{\circledR}$ device was improved from 13.5 $(6\~27)$ mm to 2.9 $(1\~4)$ mm and there were no significant instabilities of the knee in all cases. There were no leg length discrepancies over 1 cm and no statistically significant abnormal alignment of the knee joint in all cases. Conclusion: ACL reconstruction using transphyseal tunnel for restoring stability and knee function is assumed as a good mettled of treatment without significant leg length discrepancy and abnormal alignment of the knee joint.

  • PDF

Surgical Treatments of Osteosarcoma around the Knee in Children (소아 슬관절 주위 골육종의 수술적 치료)

  • Nam, Kwang-Woo;Lee, Sang-Hoon;Kim, Han-Soo;Oh, Joo-Han;Cho, Whan-Sung
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.10 no.1
    • /
    • pp.1-12
    • /
    • 2004
  • Purpose: The current study was performed to analyze the oncological and functional results, and the patient, the limb and the prosthesis survival of osteosarcoma around the knee in children according to the treatment options. Materials and Methods: From 1982 to 2002, 63 patients with osteosarcoma around the knee underwent surgical treatments before 16 years of age. Surgical treatment options were amputation, endoprosthetic replacement, and implantation of low heat-treated autogenous bone graft after wide resection of tumor. The mean age of patients was 11.5 years (4.4~16), and the mean follow-up period was 6.1 years (2.1~16.8). All patients had neoadjuvant and adjuvant chemotherapy. All endoprosthses were extendible types. Anatomical locations of osteosarcoma were distal femur in 40 patients, and proximal tibia in 23 patients. As regard to Enneking stage, 4 patients had stage $II_A$, 50 patients had stage $II_B$, and 9 patients had stage III tumors. Results: The 5 year survival rate of stage $II_B$ patients was 72.7% in amputation, 83.7% in endoprosthesis, and 100% in low heat-treated autogenous bone graft. The 5 year survival rate of salvaged limb was 84.4% in endoprosthesis, and 80% in low heat-treated autogenous bone graft. The survival rate of prosthesis was 92.7% at 5 years, 67.4% at 10 years in endoprosthesis, and 75% at 5 years in low heat-treated autogenous bone graft. Mean functional outcome scores were 8.7 points in amputation, 20.6 points in endoprosthesis, and 16 points in low heat-treated autogenous bone graft. Distant metastasis occurred 15.8% in amputation, 27% in endoprosthesis and local recurrence occurred 8.1% in endoprosthesis, 14.3% in low heat-treated autogenous bone graft. Major complications happened 26.3% in amputation, 35.1% in endoprosthesis, and 28.6% in low heat-treated autogenous bone graft. Conclusion: Limb salvage procedure had functionally better results than amputation in children with osteosarcoma around the knee. Reconstruction with endoprosthesis after resection of tumor had good results in children as adults. In certain circumstances as too small bone for endoprosthesis or minimal bony destruction or too skeletally immature patient, low heat-treated autogenous bone graft may be a good treatment option. Low heat-treated autogenous bone graft may be considered as not only a substitute for endoprosthesis but also a temporary method before endoprosthesis.

  • PDF