• Title/Summary/Keyword: analytical validation

Search Result 588, Processing Time 0.026 seconds

Validation of the semi-analytical algorithm for estimating vertical underwater visibility using MODIS data in the waters around Korea

  • Kim, Sun-Hwa;Yang, Chan-Su;Ouchi, Kazuo
    • Korean Journal of Remote Sensing
    • /
    • v.29 no.6
    • /
    • pp.601-610
    • /
    • 2013
  • As a standard water clarity variable, the vertical underwater visibility, called Secchi depth, is estimated with ocean color satellite data. In the present study, Moderate Resolvtion Imaging Spectradiometer (MODIS) data are used to measure the Secchi depth which is a useful indicator of ocean transparency for estimating the water quality and productivity. To estimate the Secchi depth $Z_v$, the empirical regression model is developed based on the satellite optical data and in-situ data. In the previous study, a semi-analytical algorithm for estimating $Z_v$ was developed and validated for Case 1 and 2 waters in both coastal and oceanic waters using extensive sets of satellite and in-situ data. The algorithm uses the vertical diffuse attenuation coefficient, $K_d$($m^{-1}$) and the beam attenuation coefficient, c($m^{-1}$) obtained from satellite ocean color data to estimate $Z_v$. In this study, the semi-analytical algorithm is validated using temporal MODIS data and in-situ data over the Yellow, Southern and East Seas including Case 1 and 2 waters. Using total 156 matching data, MODIS $Z_v$ data showed about 3.6m RMSE value and 1.7m bias value. The $Z_v$ values of the East Sea and Southern Sea showed higher RMSE than the Yellow Sea. Although the semi-analytical algorithm used the fixed coupling constant (= 6.0) transformed from Inherent Optical Properties (IOP) and Apparent Optical Properties (AOP) to Secchi depth, various coupling constants are needed for different sea types and water depth for the optimum estimation of $Z_v$.

Analytical method development for residual metamizol in meat using LC/MS/MS (식육 중 메타미졸 잔류물의 LC/MS/MS 시험법 개발)

  • Kim, Tae-Wook;Yang, Yeung-Kyong;Gwoak, Soon-Chul;Kang, Dong-Young
    • Analytical Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.237-242
    • /
    • 2011
  • In this study, an analytical method was developed for residual metamizol in beef and pork using LC/MS/MS. 4-methylaminoantipyrin (MAA), the main metabolite of metamizol was targeted for analysis instead of its parent compound. MAA was simply extracted from meat by acetonitrile, purified and then analyzed by multiple reaction monitoring method (MRM). Standard addition method was used for calibration. The calibration curves showed the linearity of $r^2$ > 0.99 for both matrices included. The developed method was validated by six-time intra-lab tests and inter-lab tests with two other institutes. The validation of the whole procedure for beef showed the intra-lab accuracies of 78-102% (CV 5.5-9.1%) and the inter-lab accuracy of 98% (CV 14%); the intra-lab accuracies of 95-99% (CV 3.9-5.6%) and the inter-lab accuracy of 111% (CV 13%).

POSCA: A computer code for fission product plateout and circulating coolant activities within the primary circuit of a high temperature gas-cooled reactor

  • Tak, Nam-il;Lee, Jeong-Hun;Lee, Sung Nam;Jo, Chang Keun
    • Nuclear Engineering and Technology
    • /
    • v.52 no.9
    • /
    • pp.1974-1982
    • /
    • 2020
  • Numerical prediction of fission product plateout and circulating coolant activities under normal operating conditions is crucial in the design of a high temperature gas-cooled reactor (HTGR). The results are used for the maintenance and repair of the components as well as the safety analysis regarding early source terms under loss of coolant accident scenarios. In this work, a new computer code named POSCA (Plate-Out Surface and Circulating Activities) was developed based on a one-dimensional model to evaluate fission product plateout and circulating coolant activities within the primary circuit of a HTGR. The verification and validation of study for the POSCA code was done using available analytical results and two in-pile experiments (i.e., OGL-1 and VAMPYR-1). The results of the POSCA calculations show that POSCA is able to simulate plateout and circulating coolant activities in a HTGR with fast computation and reasonable accuracy.

Isolation and Quantitative Analysis of Tricin from Ears of Phragmites communis (갈대이삭으로부터 Tricin의 분리 및 함량 분석)

  • Woo, Hyun Sim;Lee, Seung-Young;Hwang, Buyng Su;Jeong, Sang-Chul;Kim, Dae Wook
    • Korean Journal of Pharmacognosy
    • /
    • v.48 no.1
    • /
    • pp.77-81
    • /
    • 2017
  • The aim of this study was to investigate a validation method for determination of tricin in Phragmites communis ears. Tricin was isolated with chromatographic methods and used as the standard substances for quantitative analysis. The structural determination was characterized by comparing their NMR spectral data with values reported in the literature. For validation, the specificity, linearity, precision, accuracy, detection limits, and quantification limits of tricin was measured by HPLC. The results show that the specificity was satisfied with retention time and diode array detector (DAD) spectrum by analysis of tricin using HPLC. The limits of detection (LOD) for tricin was 0.84 mg/ml. Recovery of tricin was 98.80~108.22% with R.S.D values less than 2%. Intra-day and inter-day precisions of tricin in P. communis ears were 99.96~100.96% and 99.01~100.40%, respectively. Therefore, application of tricin was validated by an analytical method as major compound in P. communis ears.

Optimization of Ascorbic Acid Extraction from Rugosa Rose (Rosa rugosa Thunb.) Fruit Using Response Surface Methodology and Validation of the Analytical Method

  • UM, Min;KIM, Ji-Woo;LEE, Jae-Won
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.3
    • /
    • pp.364-375
    • /
    • 2020
  • In this study, ultrasound-assisted extraction was performed to extract ascorbic acid from rugosa rose (Rosa rugosa Thunb.) fruit. The optimal conditions were investigated by response surface methodology, using two variable including reaction time (16-44 min) and temperature (16-44℃). The ascorbic acid extraction was sensitive to the reaction time rather than the reaction temperature, and the optimal conditions for ascorbic acid extraction were 25℃ and 30 min. Ascorbic acid and gallic acid in the rugosa rose fruit extract were completely separated by HPLC, with a resolution factor of over 1.5 between the two. The correlation coefficient of the ascorbic acid was 0.999 in a linearity test for 50-150 ㎍/mL concentration of extract. The limit of detection and limit of quantification values were 0.16 ㎍/mL and 29.89 ㎍/mL, respectively. The relative standard deviations (RSD) for repeatability and reproducibility were determined, and each RSD showed good precision at less than 5% (N=6).

Parametric Studies on the Sensitivity of Single Isolated Aluminum Particle Combustion Modeling (알루미늄 입자 연소 지배인자의 민감도 해석)

  • Lee, Sang-Hyup;Ko, Tae-Ho;Yang, Hee-Sung;Yoon, Woong-Sup
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.321-327
    • /
    • 2010
  • A simplified analytical modeling for micro-sized single metal particle combustion in air was conducted in the present study. The metal particle combustion consists of two distinct reaction regimes, ignition and quasi-steady burning, and the thermo-fluidic phenomena in each stage are formulated by virtue of the conservation and transport equations. Reliability of the model is shown by rigorous validation of the method with emphasis laid on the characterizing the commanding parameters. Effects of Initial particle size, initial oxide film thickness, convection, ambient pressure and temperature are examined and addressed with validation.

  • PDF

Validation and measurement uncertainty of HPLC-UV method for quercetin quantification in various foods

  • Seo, Eunbin;Lim, Suji;Yun, Choong-In;Shin, Jae-Wook;Kim, Young-Jun
    • Korean Journal of Food Science and Technology
    • /
    • v.53 no.6
    • /
    • pp.682-687
    • /
    • 2021
  • The purpose of this study was to validate a high-performance liquid chromatography (HPLC) method for the quantitative analysis of quercetin in various foods. The method was based on HPLC-UV (360 nm). The method was validated using candy, beverage, and sausage which were tested for specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), precision, and accuracy, and the measurement uncertainty was assessed. Matrix-matched calibration was also applied. The calibration curves (0.5-50 mg/L) showed good linearity (r2≥0.9998). LOD and LOQ ranged from 0.15 to 0.31 mg/kg and from 0.44 to 0.93 mg/kg, respectively. The average accuracy and precision at 0.5, 2.5, and 10 mg/kg ranged from 84.3 to 102.0% and 0.7 to 3.0 relative standard deviation (RSD%), respectively. This study confirmed the applicability of the proposed method by applying it to commercial products, such as teas and beverages. Thus, the proposed analytical method is suitable for quantifying quercetin in various foods.

Validation of an HPLC/UV-based method for Salicornia herbacea-derived isorhamnetin-3-O-glucoside and quercetin-3-O-glucoside quantification

  • Park, Jun Yeon;Paje, Leo Adrianne;Kang, Ki Sung;Lee, Sanghyun
    • Journal of Applied Biological Chemistry
    • /
    • v.64 no.3
    • /
    • pp.285-290
    • /
    • 2021
  • Salicornia herbacea is a type of salt marsh plant that has been used in traditional medicine to treat several diseases. Isorhamnetin-3-O-glucoside (I3G) and quercetin-3-O-glucoside (Q3G) are major flavonoids in S. herbacea that are known to exert various pharmacological activities. Therefore, our study sought to validate and optimize an HPLC/UV-based analytical method for I3G and Q3G yield quantification, as well as to determine its limit of detection, limit of quantification, linearity, precision, and accuracy. Upon testing a concentration range of 31.5-1.9 ㎍/mL the results exhibited good linearity (r2 ≥0.9996 and r2 ≥0.9999 for I3G and Q3G, respectively), and the procedure was deemed precise (relative standard deviation of ≤3.19 and ≤3.85%, respectively), and accurate (102.6-105.0 and 92.9-95.2%, respectively). The results showed that our proposed method could be used for rapid I3G and Q3G evaluation in S. herbacea.

Development and Validation of Quantitative Analysis Method for Phenanthrenes in Peels of the Dioscorea Genus

  • Kim, Hunseong;Cao, Thao Quyen;Yeo, Chae-eun;Shin, Seung Ho;Kim, Hiyoung;Hong, Dong-Hyuck;Hahn, Dongyup
    • Journal of Microbiology and Biotechnology
    • /
    • v.32 no.8
    • /
    • pp.976-981
    • /
    • 2022
  • Phenanthrenes are bioactive phenolic compounds found in genus Dioscorea, in which they are distributed more in peel than in flesh. Recent studies on phenanthrenes from Dioscorea sp. peels have revealed the potential for valuable biomaterials. Herein, an analytical method using high-performance liquid chromatography (HPLC) for quantitation of bioactive phenanthrenes was developed and validated. The calibration curves were obtained using the phenanthrenes (1-3) previously isolated from Dioscorea batatas concentrations in the range of 0.625-20.00 ㎍/ml with a satisfactory coefficient of determination (R2) of 0.999. The limit of detection (LOD) and the limit of quantification (LOQ) values of the isolated phenanthrenes ranged from 0.78-0.89 and 2.38-2.71 ㎍/ml, respectively. The intraday and interday precision ranged from 0.25-7.58%. The recoveries of the isolated phenanthrenes were from 95 to 100% at concentrations of 1.25, 2.5, and 5.0 ㎍/ml. Additionally, phenanthrenes (1-3) were found in all investigated peel extracts. Hence, the developed method was encouraging for the quantitative analysis of phenanthrenes in genus Dioscorea.

Simulation, design optimization, and experimental validation of a silver SPND for neutron flux mapping in the Tehran MTR

  • Saghafi, Mahdi;Ayyoubzadeh, Seyed Mohsen;Terman, Mohammad Sadegh
    • Nuclear Engineering and Technology
    • /
    • v.52 no.12
    • /
    • pp.2852-2859
    • /
    • 2020
  • This paper deals with the simulation-based design optimization and experimental validation of the characteristics of an in-core silver Self-Powered Neutron Detector (SPND). Optimized dimensions of the SPND are determined by combining Monte Carlo simulations and analytical methods. As a first step, the Monte Carlo transport code MCNPX is used to follow the trajectory and fate of the neutrons emitted from an external source. This simulation is able to seamlessly integrate various phenomena, including neutron slowing-down and shielding effects. Then, the expected number of beta particles and their energy spectrum following a neutron capture reaction in the silver emitter are fetched from the TENDEL database using the JANIS software interface and integrated with the data from the first step to yield the origin and spectrum of the source electrons. Eventually, the MCNPX transport code is used for the Monte Carlo calculation of the ballistic current of beta particles in the various regions of the SPND. Then, the output current and the maximum insulator thickness to avoid breakdown are determined. The optimum design of the SPND is then manufactured and experimental tests are conducted. The calculated design parameters of this detector have been found in good agreement with the obtained experimental results.