• Title/Summary/Keyword: analytical validation

Search Result 588, Processing Time 0.029 seconds

Analysis of Zirconium and Nickel Based Alloys and Zirconium Oxides by Relative and Internal Monostandard Neutron Activation Analysis Methods

  • Shinde, Amol D.;Acharya, Raghunath;Reddy, Annareddy V.R.
    • Nuclear Engineering and Technology
    • /
    • v.49 no.3
    • /
    • pp.562-568
    • /
    • 2017
  • Background: The chemical characterization of metallic alloys and oxides is conventionally carried out by wet chemical analytical methods and/or instrumental methods. Instrumental neutron activation analysis (INAA) is capable of analyzing samples nondestructively. As a part of a chemical quality control exercise, Zircaloys 2 and 4, nimonic alloy, and zirconium oxide samples were analyzed by two INAA methods. The samples of alloys and oxides were also analyzed by inductively coupled plasma optical emission spectroscopy (ICP-OES) and direct current Arc OES methods, respectively, for quality assurance purposes. The samples are important in various fields including nuclear technology. Methods: Samples were neutron irradiated using nuclear reactors, and the radioactive assay was carried out using high-resolution gamma-ray spectrometry. Major to trace mass fractions were determined using both relative and internal monostandard (IM) NAA methods as well as OES methods. Results: In the case of alloys, compositional analyses as well as concentrations of some trace elements were determined, whereas in the case of zirconium oxides, six trace elements were determined. For method validation, British Chemical Standard (BCS)-certified reference material 310/1 (a nimonic alloy) was analyzed using both relative INAA and IM-NAA methods. Conclusion: The results showed that IM-NAA and relative INAA methods can be used for nondestructive chemical quality control of alloys and oxide samples.

NEAR INFRARED TRANSFLECTANCE SPECTROSCOPY (NIRS) IN PHYTOCHEMISTRY

  • Huck, C.W.;W.Guggenbichler;Bonn, G.K.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.3114-3114
    • /
    • 2001
  • During the last years phytochemistry and phytopharmaceutical applications have developed rapidly and so there exists a high demand for faster and more efficient analysis techniques. Therefore we have established a near infrared transflectance spectroscopy (NIRS) method that allows a qualitative and quantitative determination of new polyphenolic pharmacological active leading compounds within a few seconds. As the NIR spectrometer has to be calibrated the compound of interest has at first to be characterized by using one or other a combination of chromatographic or electrophoretic separation techniques such as thin layer chromatography (TLC), high performance liquid chromatography (HPLC), capillary electrophoresis (CE), gas chromatography (GC) and capillary electrochromatography (CEC). Both structural elucidation and quantitative analysis of the phenolic compound is possible by direct coupling of the mentioned separation methods with a mass spectrometer (GC-MS, LC-MS/MS, CE-MS, CEC-MS) and a NMR spectrometer (LC-NMR). Furthermore the compound has to be isolated (NPLC, MPLC, prep. TLC, prep. HPLC) and its structure elucidated by spectroscopic techniques (UV, IR, HR-MS, NMR) and chemical synthesis. After that HPLC can be used to provide the reference data for the calibration step of the near infrared spectrometer. The NIRS calibration step is time consuming, which is compensated by short analysis times. After validation of the established NIRS method it is possible to determine the polyphenolic compound within seconds which allows to raise the efficiency in quality control and to reduce costs especially in the phytopharmaceutical industry.

  • PDF

Analytical evaluation of the influence of vertical bridge deformation on HSR longitudinal continuous track geometry

  • Lai, Zhipeng;Jiang, Lizhong;Liu, Xiang;Zhang, Yuntai;Zhou, Tuo
    • Steel and Composite Structures
    • /
    • v.44 no.4
    • /
    • pp.473-488
    • /
    • 2022
  • A high-speed railway (HSR) bridge may undergo long-term deformation due to the degradation of material stiffness, or foundation settlement during its service cycle. In this study, an analytical model is set up to evaluate the influence of this long-term vertical bridge deformation on the track geometry. By analyzing the structural characteristics of the HSR track-bridge system, the energy variational principle is applied to build the energy functionals for major components of the track-bridge system. By further taking into account the interlayer's force balancing requirements, the mapping relationship between the deformation of the track and the one of the bridge is established. In order to consider the different behaviors of the interlayers in compression and tension, an iterative method is introduced to update the mapping relationship. As for the validation of the proposed mapping model, a finite element model is created to compare the numerical results with the analytical results, which show a good agreement. Thereafter, the effects of the interlayer's different properties of tension and compression on the mapping deformations are further evaluated and discussed.

Determination of Capsaicinoids in Selected Commercial Pepper Powders and Pepper-Containing Products Using HPLC and Method Validation (HPLC를 이용한 일부 시판 고춧가루 및 고추 가공품의 Capsaicinoids 함량 분석 및 분석법의 검증)

  • Ham, Hyeon-Mi;Sung, Mi-Sun;Kim, Young-Hwa;Choi, Young-Min;Jeong, Heon-Sang;Lee, Jun-Soo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.6
    • /
    • pp.870-874
    • /
    • 2012
  • The objective of this study was to determine the content of capsaicinoids in different commercial pepper powders and pepper-containing products in the Korean market. The two major capsaicinoids in the samples, capsaicin and dihydrocapsaicin, were analyzed using reversed-phase HPLC. The levels of capsaicin and dihydrocapsaicin in pepper powders and pepper-containing products ranged from 0.21 to 78.24 and 0.20 to 38.82 mg/100 g sample, respectively. Pepper powders contained generally higher amounts of capsaicin and dihydrocapsaicin than pepper- containing products. In addition, the analytical method validation parameters including accuracy, precision, and specificity were provided to ensure the validity of the extraction procedure for capsaicinoid analysis. Overall recovery from pepper powder and pepper paste was close to 100% (n=3). The results of validation parameters indicated that the present method was reliable and reproducible for the HPLC analyses of capsaicin and dihydrocapsaicin in commercial pepper products.

Development Rapid Analytical Methods for Inositol as a Trace Component by HPLC and LC-MS/MS in Infant Formula

  • Shin, Jin-Ho;Park, Jung-Min;Kim, Ha-Jung;Ahn, Jang-Hyuk;Kwak, Byung-Man;Kim, Jin-Man
    • Food Science of Animal Resources
    • /
    • v.35 no.4
    • /
    • pp.466-472
    • /
    • 2015
  • A rapid and simple analytical method, using liquid chromatography tandem mass spectrometry (LC-MS/MS), was developed to detect myo-inositol (MI) in infant formulas. For protein removal: acid hydrolysis and lipid removal through organic solvent extraction. The operating conditions for instrumental analysis were determined based on previously reported analogous methods that used LC-MS/MS. Quantitative analysis was used for the detection limit test, infant formula recovery test, and standard reference material (SRM) 1849a to verify the validity of our LC-MS/MS analytical method, which was developed to quantify MI. For validation, the results of our method were compared with the results of quantitative analyses of certified values. The test results showed that the limit of detection was 0.05 mg/L, the limit of quantitation was 0.17 mg/L, and the method detection limit was 17 mg/kg. The recovery test exhibited a recovery between 98.07-98.43% and a relative standard deviation between 1.93-2.74%. Therefore, the result values were good. Additionally, SRM 1849a was measured to have an MI content of 401.84 mg/kg and recovery of 98.25%, which is comparable to the median certified value of 409 mg/kg. From the aforementioned results, we judged that the instrumental analysis conditions and preparation method used in this study were valid. The rapid analytical method developed herein could be implemented in many laboratories that seek to save time and labor.

Determination of Veterinary Antibiotic Residues: III. Analytical Methods_A Review (시료 중 잔류 항생제 분석 방법: III. 기기 분석 방법)

  • Kim, Chansik;Ryu, Hong-Duck;Chung, Eu Gene;Kim, Yongseok;Rhew, Doug Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.6
    • /
    • pp.649-669
    • /
    • 2016
  • This study explored the analytical conditions for 21 veterinary antibiotics which have been popularly sold in South Korea in 2014 but have not yet been targeted in EPA method 1694. Most of the selected antibiotics were separated by a reverse-phase C18 column with a combination of (buffered) water and organic polar solvent, which was commonly methanol and acetonitrile in the gradient elution mode. Volatile additives such as formic acid, ammonium acetate and ammonium formate were usually added to the mobile phases to minimize asymmetrical and tailing of antibiotics' peaks and to increase their ionization in mass spectrometry. The analytical methods of aminoglycoside antibiotics were distinct from those of the other antibiotics in terms of adoption of ion-pair chromatography (IPC) and hydrophilic interaction liquid chromatography (HILIC) capable of retaining and separating extremely polar compounds due to their hydrophilicity. Trifluoroacetic acid or heptafluorobutyric acid was frequently added to the mobile phase as an ion-pair reagent for the IPC. Tandem mass spectrometry was numerously applied to the detection of antibiotics using positive electrospray ionization (ESI) and the selected reaction monitoring (SRM) mode. All reviewed analytical methods had been/were validated by evaluating recovery, limits of detection and quantification, decision limit or detection capability of the methods.

Direct Quantitation of Amino Acids in Human Serum Using a Stepwise-Dilution Strategy and a Mixed-Mode Liquid Chromatography-Tandem Mass Spectrometry Method

  • Lee, Jaeick;Lee, Seunghwa;Kim, Byungjoo;Lee, Joonhee;Kwon, Oh-Seung;Cha, Eunju
    • Mass Spectrometry Letters
    • /
    • v.9 no.1
    • /
    • pp.30-36
    • /
    • 2018
  • A quantitation method for free amino acids in human serum was developed using a stepwise-dilution method and a bimodal cation exchange (CEX)/hydrophilic interaction liquid chromatography (HILIC)-tandem mass spectrometry system equipped with an electrospray ionization source (ESI/MS/MS). This method, which was validated using quality control samples, was optimized for enhanced selectivity and sensitivity. Dithiothreitol (DTT) was used as a reducing agent to prevent the oxidation of a serum sample ($50{\mu}L$), which was then subjected to stepwise dilution using 3, 30, and 90 volumes of acetonitrile containing 0.1% formic acid. Chromatographic separation was performed on an Imtakt Intrada Amino Acid column ($50mm{\times}3mm$, $3{\mu}m$) in mixed mode packed with CEX and HILIC ligands embedded in the stationary phase. Underivatized free amino acids were eluted and separated within 10 min. As a result of the validation, the precision and accuracy for the inter- and intraday assays were determined as 2.11-11.51% and 92.82-109.40%, respectively. The lowest limit of quantification (LLOQ) was $0.5-4.0{\mu}g/mL$ and the matrix effect was 80.22-115.93%. The proposed method was successfully applied to the quantitative analysis of free amino acids in human serum.

A Semi-analytical Approach for Numerical Analysis of Residual Stress in Oxide Scale Grown on Hot-rolled Steels (열간압연강에서 형성된 산화물 스케일의 잔류 응력 수치 분석을 위한 준해석적 방법 개발)

  • Y.-J. Jun;J.-G. Yoon;J.-M. Lee;S.-H. Kim;Y.-C. Kim;S. Nam;W. Noh
    • Transactions of Materials Processing
    • /
    • v.33 no.3
    • /
    • pp.200-207
    • /
    • 2024
  • In this study, we developed a semi-analytical approach for the numerical analysis of residual stress in oxide scales formed on hot-rolled steels. The oxide scale, formed during the hot rolling process, experiences complex interactions due to thermal and mechanical influences, significantly affecting the material's integrity and performance. Our research focuses on integrating various stress components such as thermal stress, growth stress, and creep behavior to predict the residual stress within the oxide layer. The semi-analytical method combines analytical expressions for each stress component with numerical integration to account for their cumulative effects. Validation through instrumented indentation tests confirms the reliability of our model, which considers thermal expansion coefficient (CTE) differences, scale growth, and creep-induced stress relaxation. Our findings indicate that thermal stress resulting from CTE differences significantly impacts the overall residual stress, with growth stress contributing a compressive component during cooling, and creep behavior playing a minor role in stress relaxation. This comprehensive approach enhances the accuracy of residual stress prediction, facilitating the optimization of material design and processing conditions for hot-rolled steel products.

Analytical method validation and monitoring of levulinic acid in soy sauce and their application to food (간장 및 이를 활용한 식품의 레불린산 분석방법 검증 및 모니터링)

  • Kim, Dan-Bi;Kim, Sunyoung;Lee, Sanghee;Yoo, Miyoung
    • Analytical Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.295-302
    • /
    • 2017
  • This study presents a method validation for extraction and quantitative analysis of levulinic acid in soy sacues using high performance liquid chromatograph-photodiode array detector (HPLC-PDA). The levulinic acid in samples were extracted with distilled water, and then purified with C18 Sep-Pak cartridge. The calibration curves showed good linearity (R > 0.999) in a relatively wide concentration range ($2.5-400{\mu}g/mL$). Mean recoveries and relative standard deviation (RSD) of levulinic acid spiked in soy sauce samples at different spiking levels ($2.5-400{\mu}g/mL$; 6 point). Recoveries were 87.58-97.26 % with RSD less than 15 %, and limit of detection (LOD) and limit of quantification (LOQ) were 0.64 and $1.64{\mu}g/mL$, respectively. According to monitoring result with the established method, levulinic acid was found in 43 of 59 domestic commercial soy sauces, soy sauce based sauces and seasoned meats. The contamination levels were 0.44-1.23 mg/mL for soy sauces, 0.03-0.83 mg/mL for soy sauce based sauces and 8.43-38.94 mg/mL for seasoned meats. The results indicated to be rapidly and accurately qualifying levulinic acid and can be used as a suitable quality control method for soy sauce and soy sauce related commodities.

Development and Validation of an Analytical Method for Betanine and Isobetanine in Processed Food Products Labeled with Beet Red

  • Kang, Hyun-Hee;Yun, Choong-In;Lee, Gayeong;Shin, Jae-Wook;Kim, Young-Jun
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.5
    • /
    • pp.376-381
    • /
    • 2021
  • Red beet (Beta vulgaris L.) is a root vegetable and a popular functional food ingredient of dark red-purple appearance due largely to betacyanins, principally betanine (75-95%) and its isomer, isobetanine (15-45%). This study developed an analytical method for beet red in terms of betanine and isobetanine in processed food products labeled with beet red as a food additive. High Performance Liquid Chromatography-Diode Array Detector (HPLC-DAD) was used with a C18 column. Linearity, limit of detection (LOD), limit of quantitation (LOQ), accuracy, precision and uncertainty in measurement were calculated for method validation. Matrix-matched calibration was applied to the candy, ice cream, and cocoa product, respectively, and R2 was ≥0.9998, showing a high level of linearity. The LOD and LOQ were 0.16 to 0.32 and 0.48 to 0.97 mg/L, respectively. As a result of repeated intra-day and interday experiments to validate the accuracy and precision of the analytical method, the recovery rates were 96.0-103.1% and 100.0-102.2%, respectively and the RSD% was 0.5-3.3% and 0.9-3.8%, respectively. Moreover, the measurement uncertainty was estimated to be 1.71-12.43% depending on the matrix and the measured concentration. In this study, betanine and isobetanine were quantified (8.4-3,823.4 mg/kg) by applying the developed analytical method to processed food products (n= 26; e.g., candy, ice cream, and other processed foods) labeled with beet red as a food additive.