• 제목/요약/키워드: analysis-dark current

검색결과 65건 처리시간 0.033초

Solution processed organic photodetector utilizing an interdiffused polymer/fullerene bilayer

  • Shafian, Shafidah;Jang, Yoonhee;Kim, Kyungkon
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.348-348
    • /
    • 2016
  • Low dark current (off-current) and high photo current are both essential for a solution processed organic photodetector (OPD) to achieve high photo-responsivity. Currently, most OPDs utilize a bulk heterojunction (BHJ) photo-active layer that is prepared by the one-step deposition of a polymer:fullerene blend solution. However, the BHJ structure is the main cause of the high dark current in solution processed OPDs. It is revealed that the detectivity and spectral responsivity of the OPD can be improved by utilizing a photo-active layer consisting of an interdiffused polymer/fullerene bilayer (ID-BL). This ID-BL is prepared by the sequential solution deposition (SqD) of poly(3-hexylthiophene) (P3HT) and [6,6] phenyl C61 butyric acid methyl ester (PCBM) solutions. The ID-BL OPD is found to prevent undesirable electron injection from the hole collecting electrode to the ID-BL photo-active layer resulting in a reduced dark current in the ID-BL OPD. Based on dark current and external quantum efficiency (EQE) analysis, the detectivity of the ID-BL OPD is determined to be $7.60{\times}1011$ Jones at 620 nm. This value is 3.4 times higher than that of BHJ OPDs. Furthermore, compared to BHJ OPDs, the ID-BL OPD exhibited a more consistent spectral response in the range of 400 - 660 nm.

  • PDF

Ohmic Contact for Hole Injection Probed by Dark Injection Space-Charge-Limited Current Measurements

  • Song, Ok-Keun;Koo, Young-Mo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.1061-1064
    • /
    • 2009
  • Through dark injection space-charge-limited current (DI-SCLC) and trap-free SCLC measurements, it has been demonstrated that an indium tin oxide (ITO)/buckminsterfullerene ($C_{60}$) electrode can form a quasi-Ohmic contact with N, N'-bis (naphthalen-1-yl)-N, N'-bis(phenyl) benzidine (NPB). The DI-SCLC results show a clear peak current along with a shift of the peak position as the field intensity varies, implying an Ohmic (or quasi-Ohmic) contact. A theoretical simulation of the SCLC also shows that ITO/$C_{60}$ forms an Ohmic contact with NPB. The Ohmic contact makes it possible to estimate the NPB hole mobility through the use of both DI-SCLC and trap-free SCLC analysis. This also contributes to a reduction in power consumption.

  • PDF

a-Si:H Image Sensor for PC Scanner

  • Hur, Chang-Wu
    • Journal of information and communication convergence engineering
    • /
    • 제5권2호
    • /
    • pp.116-120
    • /
    • 2007
  • In this paper, the image sensor using the a-Si:H TFT is proposed. The optimum amorphous silicon thin film is deposited using plasma enhanced chemical vapor deposition (PECVD). TFT and photodiode both with the thin film are fabricated and form image sensor. The photodiode shows that $I_{dark}\;is\;{\sim}10^{-13}\;A,\;I_{photo}\;is\;{\sim}10^{-9}\;A\;and\;I_{photo}/I_{dark}\;is\;{\sim}10^4$, respectively. In the case of a-Si:H TFT, it indicates that $I_{on}/I_{off}\;is\;10^6$, the drain current is a few ${\mu}A\;and\;V_{th}\;is\;2{\sim}4$ volts. For the analysis on the fabricated image sensor, the reverse bias of -5 volts in ITO of photodiode and $70 {\mu}sec$ pulse in the gate of TFT are applied. The image sensor with good property was conformed through the measured photo/dark current.

Dark Field Digital Holographic Microscopy Based on Two-lens 360-degree Oblique Illumination

  • Zhang, Xiuying;Zhao, Yingchun;Yuan, Caojin;Feng, Shaotong;Wang, Lin
    • Current Optics and Photonics
    • /
    • 제4권3호
    • /
    • pp.193-199
    • /
    • 2020
  • In this paper we propose a dark-field digital holographic microscopy system based on 360-degree oblique illumination. This setup is constructed without using a dark-field objective. The principle of 360-degree oblique illumination of vortex beam and dark-field digital holographic microscopy are introduced theoretically and experimentally. By analyzing the reconstructed image of a dark-field digital hologram of a USAF 1951 target, it is proved that the imaging resolution can be improved by this method. And also, comparison and analysis are made on the reconstructed image of a bright-dark field digital hologram of a pumpkin stem slice, the result shows that the imaging contrast is also enhanced with this method, and it is effective for dark-field digital holographic microscopy imaging of large transparent biological samples.

등가회로 모델에 의한 레이저다이오드의 누설전류 해석 (Analysis of Leakage Current of a Laser Diode by Equivalent Circuit Model)

  • 최영규;김기래
    • 한국정보통신학회논문지
    • /
    • 제11권2호
    • /
    • pp.330-336
    • /
    • 2007
  • 본 논문에서는 디지털 의료 영상 및 진단 분야 그리고 산업용으로도 활용 가능한 싱글 포톤 계수형 영상센서를 $0.18{\mu}m$ triple-well CMOS(Complementary Metal Oxide Semiconductor) 공정을 사용하여 설계하였다. 설계된 Readout 칩용 싱글 픽셀은 디지털 X-ray 이미지 센서모듈을 간단화 하기 위해 단일 전원전압을 사용하였으며, Preamplifier의 출력 전압인 signal voltage(${\Delta}Vs$)를 크게 하기 위해 Folded Cascode CMOS OP amp를 이용한 Preamplifier를 설계하였으며, 기존의 Readout 칩 외부에서 인가하던 threshold voltage를 Readout 칩 내부에서 생성해 줄 수 있도록 Externally Tunable Threshold Voltage Generator 회로를 새롭게 제안하였다. 그리고, Photo Diode에서 발생하는 Dark Current Noise를 제거하기 위한 Dark Current Compensation 회로를 제안하였으며, 고속 counting이 가능하고, layout 면적이 작은 15bit LFSR(Linear Feedback Shift Resister) Counter를 설계하였다.

Analysis of Dark Data of the PICNIC IR Arrays in the CIBER

  • Lee, D.H.;Kim, M.G.;Tsumura, K.;Zemcov, M.;Nam, U.W.;Bock, J.;Battle, J.;Hristov, V.;Renbarger, T.;Matsumoto, T.;Sullivan, I.;Levenson, L.R.;Mason, P.;Matsuura, S.;Kim, G.H.
    • Journal of Astronomy and Space Sciences
    • /
    • 제27권4호
    • /
    • pp.401-406
    • /
    • 2010
  • We have measured and analyzed the dark data of two PICNIC IR arrays (P574 and P560) obtained through the Cosmic Infrared Background ExpeRiment (CIBER). First, we identified three types of bad pixels: the cold, the hot, and the transient, which are figured in total as 0.06% for P574 and 0.19% for P560. Then, after the bad pixels were masked, we determined the dark noise to be 20.5 ${\pm}$ 0.05 $e^-$ and 16.1 ${\pm}$ 0.05 $e^-$, and the dark current to be 0.6 ${\pm}$ 0.05 $e^-$/sec and 0.7 ${\pm}$ 0.05 $e^-$/sec for P574 and P560, respectively. Finally, we discussed glitches and readout modes for a future mission.

Estimating dark matter mass for the most massive high-z galaxy cluster, SPT-CL J2106-5844 using weak-lensing analysis with HST observations

  • Kim, Jinhyub;Jee, Myungkook James;Ko, Jongwan
    • 천문학회보
    • /
    • 제41권1호
    • /
    • pp.67.2-67.2
    • /
    • 2016
  • SPT-CL J2106-5844 is known to be one of the most massive galaxy clusters ($M_{200}{\sim}1.27{\times}10^{15}M_{sun}$) ever found at z > 1. Given its redshift (z ~ 1.132), the mass of this cluster estimated by Sunyaev-Zel'dovich effect and X-ray observation is too large compared with the current ${\Lambda}CDM$ cosmology prediction. Mass estimation from these methods can be biased because they require assumptions on hydrostatic equilibrium, which are not guaranteed to hold at such high redshift (about 40% of the current age of the Universe). Thus, we need to verify the mass of this interesting cluster using gravitational lensing, which does not require such assumptions. In this work, we present our preliminary result of dark matter mass and its spatial mass distribution of SPT-CL J2106-5844 using weak-lensing analysis based on HST optical/NIR deep imaging data. We compare mass estimates from different sources and discuss cosmological implications.

  • PDF

디지털 래디오그라피의 신호 및 잡음 특성에 대한 방사선 영향에 관한 연구 (Investigation of Radiation Effects on the Signal and Noise Characteristics in Digital Radiography)

  • 김호경;조민국
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권6호
    • /
    • pp.756-767
    • /
    • 2007
  • For the combination of phosphor screens having various thicknesses and a photodiode array manufactured by complementary metal-oxide-semiconductor (CMOS) process, we report the observation of image-quality degradation under the irradiation of 45-kVp spectrum x rays. The image quality was assessed in terms of dark pixel signal, dynamic range, modulation-transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). For the accumulation of the absorbed dose, the radiation-induced increase both in dark signal and noise resulted in the gradual reduction in dynamic range. While the MTF was only slightly affected by the total ionizing dose, the noise power in the case of $Min-R^{TM}$ screen, which is the thinnest one among the considered screens in this study, became larger as the total dose was increased. This is caused by incomplete correction of the dark current fixed-pattern noise. In addition, the increase tendency in NPS was independent of the spatial frequency. For the cascaded model analysis, the additional noise source is from direct absorption of x-ray photons. The change in NPS with respect to the total dose degrades the DQE. However, with carefully updated and applied correction, we can overcome the detrimental effects of increased dark current on NPS and DQE. This study gives an initial motivation that the periodic monitoring of the image-quality degradation is an important issue for the long-term and healthy use of digital x-ray imaging detectors.

FINDING THE ACCELERATION PARAMETER IN MODIFIED NEWTONIAN DYNAMICS WITH ELLIPTICAL GALAXIES

  • TIAN, YONG;KO, CHUNG-MING
    • 천문학논총
    • /
    • 제30권2호
    • /
    • pp.381-383
    • /
    • 2015
  • MOdified Newtonian Dynamics (MOND) is an alternative to the dark matter paradigm. MOND asserts that when the magnitude of acceleration is smaller than the acceleration parameter $a_0$, the response of the system to gravity is stronger (larger acceleration) than the one given by Newtonian dynamics. The current value of $a_0$ is obtained mostly by observations of spiral galaxies (rotation curves and the Tully-Fisher relation). We attempt to estimate $a_0$ from the dynamics of elliptical galaxies. We seek elliptical galaxies that act as the lens of gravitational lensing systems and have velocity dispersion data available. We analysed 65 Einstein rings from the Sloan Len ACS survey (SLACS). The mass estimates from gravitation lensing and velocity dispersion agree well with each other, and are consistent with the estimates from population synthesis with a Salpeter IMF. The value of $a_0$ obtained from this analysis agrees with the current value.

Simple Analysis for Interaction between Nanoparticles and Dye-Containing Vesicles as a Biomimetic Cell-Membrane

  • Shin, Sohyang;Umh, Ha Nee;Kim, Younghun
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권1호
    • /
    • pp.231-236
    • /
    • 2013
  • Some cytotoxicity studies for the interpretation of the interaction between nanoparticles and cells are non-mechanistic and time-consuming. Therefore, non-biological screening methods, which are faster and simpler than in-vivo and in-vitro methods, are required as alternatives to current cytotoxicity tests. Here, we proposed a simple screening method for the analysis of the interaction between several AgNPs (bare-, citrate-, and polyvinylpyrrolidone-coating) and dye-containing vesicles acting as a biomimetic cell-membrane. The interaction between AgNPs and vesicles could be evaluated readily by UV-vis spectra. Absorbance deviation in UV-vis spectra revealed a large attraction between neighboring particles and vesicles. This was confirmed by (Derjagin, Landau, Verwey, and Overbeek) theory and DMF (dark-field microscopy) analysis. This proposed method might be useful for analyzing the cytotoxicity of nanoparticles with cell-membranes instead of in vitro or in vivo cytotoxicity tests.