• Title/Summary/Keyword: analog multiplexer

Search Result 15, Processing Time 0.018 seconds

Reconstruction of Current Waveform for Traction Control of Battery Car using Parallel-connected MOSFET's On-Voltage (배터리차 추진제어를 위한 병렬 MOSFET의 도통전압을 이용한 전류파형 검출)

  • 장성동;김성중;정재호;신휘범
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.197-200
    • /
    • 1999
  • In this paper, an algorithm of reconstructing the armature current of the battery car is presented by using MOSFET's on-voltage of the dc chopper and a corresponding circuit is developed with the low-cost analog multiplexer. For driving comfort, the armature current of the motor or the traction force should be properly controlled when the car changes the direction and is accelerated or decelerated and climbs up or down the hill. Therefore, an information of the current is needed for the traction control. The proposed reconstruction algorithm is experimentally verified.

  • PDF

Development of microcomputer-based on-line measurement system. (마이크로컴퓨터를 이용한 온-라인 측정 시스템의 개발)

  • ;;Chung, Myung Kyoon;Lee, Dong In
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.5 no.4
    • /
    • pp.274-283
    • /
    • 1981
  • An inexpensive and very simple microcomputer-aided measurement system has been designed for on-line experiments, which perform simultaneously data acquisition, data recorditing, calculations with the data, and positioning of necessary sensors. Interfacting between the microcomputer and the data acquisition board which consists of A/D converter, analog multiplexer, and sample-and-holder, etc. has been done through IEEE-488 interface port and parallel user port both provided by the PET computer's main logic board. Data and control signals are transfered between devices without handshaking. By utilizing BASIC commands PEEK, POKE, SYS, USR which are offered by PET microcomputer, it is possible to link machine code subroutines into the main BASIC program. This facilitates ease of data transfer, programming, and speedy execution of the program. In addition, an X-Y scanning table has been concected to the system in order to automatically position measuring sensors along a pre-determined path of interest.

Digital correction and calibration circuits for a high-resolution CMOS pipelined A/D converter (파이프라인 구조를 가진 고해상도 CMOS A/D 변환기를 위한 디지탈 교정 및 보정 회로)

  • 조준호;최희철;이승훈
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.6
    • /
    • pp.230-238
    • /
    • 1996
  • In this paper, digital corrction and calibration circuit for a high-resolution CMOS pipelined A/D converter are proposed. The circuits were actually applied to a 12 -bit 4-stage pipelined A/D converter which was implemented in a 0.8${\mu}$m p-well CMOS process. The proposed digital correction logic is based on optimum multiplexer and two nonoverlapping clock phases resulting in a small die area snd a modular pipelined architecture. The propsoed digital calibration logic which consists of calibration control logic, error averaging logic, and memory can effectively perform self-calibration with little modifying analog functional bolcks of a conventional pipelined A/D conveter.

  • PDF

A Study on the Application of Several Different Sensors (다수 이종 센서 운용에 관한 연구)

  • Kim, Do-Hun;Lee, Kyo-Sung;Oh, Se-Ho;Park, Jung-Gyun;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2565-2567
    • /
    • 2002
  • In this paper, the application of many different sensors in data acquisition system is discussed. According to the input signal type getting into analog multiplexer, it is necessary to assign different sampling time. To achieve the object, we designed the sub-systems by the simple auxiliary controller which is managed the particular sensor causing the troubles to main controller system.

  • PDF

Implementation of Capacitance Measurement Equipment for Fault Diagnosis of Multi-channel Ultrasonic Probe (다중채널 초음파 프로브 고장진단을 위한 커패시턴스 측정 장치 구현)

  • Kang, Bub-Joo;Kim, Yang-soo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.1
    • /
    • pp.175-184
    • /
    • 2016
  • In this paper, we propose the method to measure the capacitances using not LCR meter but capacitance to voltage(C/V) conversion. And we design the analog MUX circuits that convert 192 channels to 6 MUX channels in order to implement the diagnosis of multi-channel ultrasonic probe. This paper derives the conversion function that converts the digital voltage of each MUX channel to the capacitance using the least squares method because the circuit characteristics that convert the voltage of each MUX channel to the capacitance are different. The developed prototype illustrates the performance test results that the measure times are measured by within 4sec and the measure error rates of maximum, minimum, and average values are within 5% in terms of the repeated measurements of all 192 channels.