• 제목/요약/키워드: amplitude of initial fault current

검색결과 4건 처리시간 0.023초

고온초전도 전류제한기의 초기사고전류 제한시점 분석 (Analysis of the Initial Fault Current Limiting Point of the SFCLs)

  • 박충렬;두호익;두승규;김용진;김민주;조용선;최효상;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.292-292
    • /
    • 2008
  • The superconducting fault current limiter(SFCL) can be used to limit fault current level in electrical transmission line and power system. Up to now, there are several kinds of SFCL that have proposed and it is expects that they will be applied to appropriated position considering their own properties; initial fault current limiting instant and the current limiting characteristics. In this paper, we investigated the initial fault current limiting instant and the amplitude of initial fault current in the resistive type, the flux-lock type, the flux-coupling type and the transformer type SFCL. Experiment results show that the initial fault current limiting instant and the amplitude of initial fault current of the SFCLs are dependant on the ratio of inductance of primary and secondary coils.

  • PDF

피크전류제한 기능을 갖는 초전도한류기의 전류제한 특성분석 (Analysis on Current Limiting Characteristics of a Superconducting Fault Current Limiter (SFCL) with a Peak Currnt Limiting Function)

  • 한태희;임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제24권1호
    • /
    • pp.47-51
    • /
    • 2011
  • The superconducting fault current limiter (SFCL) with a peak current limiting function according to the initial fault current with the different amplitudes was suggested. The proposed SFCL, which consists of two limiting components, causes only the first superconducting element among two limiting components to be quenched in case that the initial fault current with the lower peak amplitude happens. On the other hand, the initial fault current with the higher peak amplitude makes both the superconducting elements of two limiting components to be quenched, which contributes to the peak current limiting function of the SFCL. To confirm the fault current limiting operation of the proposed SFCL, the short-circuit tests of the SFCL according to the fault angle were carried out and its effective fault current limiting operations could be discussed.

자속구속형 고온초전도 전류제한기의 사고초기 제한 전류변화 분석 (Analysis for Variation of Limiting Current at Initial Fault Time in Flux-Lock Type SFCL)

  • 임성훈;최효상;강형곤;고석철;이종화;한병성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.418-420
    • /
    • 2003
  • The fault current limiting characteristics at the initial fault time for flux-lock type high-Tc superconducting fault current limiter(SFCL) were investigated. The amplitude of initial fault current of the flux-lock type SFCL was dependent on the inductance ratio of coil 1 and 2. After fault current limiting mode was analyzed, we compared the calculated value with the experimental one for the initial fault current. The effect of initial fault current due to the inductance ratio of coil 1 and 2 on fault current limiting characteristics was discussed.

  • PDF

감극 결선시 자속구속형 전류제한기의 퀜치 특성 (Quench Characteristics of Flux-lock Type SFCL in Subtractive Polarity Winding)

  • 황종선;한태희;최효상;박형민;조용선;남궁현;이나영;임성훈;정동철;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.251-252
    • /
    • 2006
  • As one of methods to increase the voltage rating of the flux-lock type SFCL, the fault current limiting characteristics of the flux-lock type SFCL with HTSC elements connected in series were analyzed. The initial fault current amplitudes in two SFCLs with the series connection of two HTSC elements and with single HTSC element were the same. In addition, the resistance amplitude of each HTSC element in SFCL with the series connection of two HTSC elements had the similar one in SFCL with single HTSC element. With increase of applying voltage, the unbalance of voltage between two HTSC elements in SFCL with the series connection of two HTSC elements disappeared.

  • PDF