• Title/Summary/Keyword: amplitude method

Search Result 2,231, Processing Time 0.029 seconds

Nonlinear vibration analysis of a type of tapered cantilever beams by using an analytical approximate method

  • Sun, Weipeng;Sun, Youhong;Yu, Yongping;Zheng, Shaopeng
    • Structural Engineering and Mechanics
    • /
    • v.59 no.1
    • /
    • pp.1-14
    • /
    • 2016
  • In this paper, an alternative analytical method is presented to evaluate the nonlinear vibration behavior of single and double tapered cantilever beams. The admissible lateral displacement function satisfying the geometric boundary conditions of a single or double tapered cantilever beam is derived by using Rayleigh-Ritz method. Based on the Lagrange method and the Newton Harmonic Balance (NHB) method, analytical approximate solutions in closed and explicit form are obtained. These approximate solutions show excellent agreement with those of numeric method for small as well as large amplitude. Moreover, due to brevity of expressions, the present analytical approximate solutions are convenient to investigate effects of various parameters on the large amplitude vibration response of tapered beams.

The Performance of Dual Structure CR-CMA Adaptive Equalizer for 16-QAM Signal (16-QAM 신호에 대한 이중 구조 CR-CMA 적응 등화기의 성능)

  • Yoon, Jae-Sun;Lim, Seung-Gag
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.5
    • /
    • pp.107-114
    • /
    • 2012
  • In this paper, the concerned existing blind equalizer convergence rate and residual inter-symbol interference using constellation reduced and cost function by separation the real part and an imaginary part, the dual structure CR-CMA(constellation Reduction CMA). The CMA methed compensates amplitude but does no compensate phase, On the other hand, The CMA method compensates both the amplitude and the phase but it has the convergence rate problem, and the MCMA method is a way to solve the phase problem of CMA method compensates both the amplitude and the phase after respectively calculating the real part and imaginary part components. Proposal a new method that the dual structure of CR-CMA, the cost function and error function and respectively calculating the real part and imaginary part components can advantages by improving the CMA and the MCMA algorithms so that the amplitude and phase retrieval and constellation reduce the residual ISI and faster convergence rate and performance is good SER (Symbol Error Ratio) was confirmed by computer simulations.

A Study on Compensation of Amplitude in Multi Pulse (멀티펄스의 진폭보정에 관한 연구)

  • Lee, See-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.9
    • /
    • pp.4119-4124
    • /
    • 2011
  • In a MPC coding using excitation source of voiced and unvoiced, it would be a distortion of speech waveform in case of increasing or decreasing of speech signal amplitude in a frame. This is caused by normalization of synthesis speech signal in the process of restoration the multi-pulses of representation section. To solve this problem, this paper present a method of amplitude compensation(AC-MPC) in a multi-pulses each pitch interval in order to reduce distortion of speech waveform. I was confirmed that the method can be synthesized close to the original speech waveform. And I evaluate the MPC and AC-MPC using amplitude compensation method. As a result, SNRseg of AC-MPC was improved 0.7dB for female voice and 0.7dB for male voice respectively. Compared to the MPC, SNRseg of AC-MPC has been improved that I was able to control the distortion of the speech waveform finally. And so, I expect to be able to this method for cellular phone and smart phone using excitation source of low bit rate.

Numerical Integration-based Performance Analysis of Amplitude-Comparison Monopulse System (진폭비교 모노펄스시스템의 수치적분 기반 성능분석)

  • Ham, Hyeong-Woo;Lim, Hee-Yun;Lee, Joon-Ho
    • Journal of Digital Convergence
    • /
    • v.19 no.12
    • /
    • pp.339-345
    • /
    • 2021
  • In this paper, estimation angle performance analysis of amplitude-comparison monopulse radar under additive noise effect is dealt with. When uncorrelated white noises are added to the squinted beams, the angle estimation performance is analyzed through the mean square error(MSE). The numerical integration-based mean square error result completely overlaps the Monte Carlo-based mean square error result, which corresponds to 99.8% of the Monte Carlo-based mean square error result. In addition, the mean square error analysis method based on numerical integration has a much faster operation time than the mean square error method based on Monte Carlo. the angle estimation performance of the amplitude comparison monopulse radar can be efficiently analyzed in various noise environments through the proposed numerical integration-based mean square error method.

FUNDAMENTAL PERFORMANCE OF IMAGE CODING SCHEMES BASED ON MULTIPULSE MODEL

  • Kashiwagi, Takashi;Kobayashi, Daisuke;Koda, Hiromu
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.825-829
    • /
    • 2009
  • In this paper, we examine the fundamental performance of image coding schemes based on multipulse model. First, we introduce several kinds of pulse search methods (i.e., correlation method, pulse overlap search method and pulse amplitude optimization method) for the model. These pulse search methods are derived from auto-correlation function of impulse responses and cross-correlation function between host signals and impulse responses. Next, we explain the basic procedure of multipulse image coding scheme, which uses the above pulse search methods in order to encode the high frequency component of an original image. Finally, by means of computer simulation for some test images, we examine the PSNR(Peak Signal-to-Noise Ratio) and computational complexity of these methods.

  • PDF

Study on the Precision Method of Measuring angular displacement for the Angular Vibration Calibration System (회전 진동 교정 장치 구현을 위한 고정밀 측정기법에 대한 연구)

  • Cheung, Wan-Sup;Lee, Yong-Bong;Lee, Doo-Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.685-688
    • /
    • 2004
  • This paper addresses the study on developing the angular vibration calibration system which requires the highly accurate measurement technique of the amplitude and period of an oscillating angular motion. Two developed models for the low and high frequency ranges are introduced and their main features are also compared. In addition to the angular vibration exciters, a new measurement method, referred to the 'equi-angle sampling method', is proposed and its theoretical backgrounds are introduced. The proposed method is shown to provide much less measurement uncertainty, compared the fringe counting method. Experimental results demonstrate what amount of angular vibration amplitude measurement uncertainty is improved by suing the proposed equi-angle sampling method.

  • PDF

The image construction of the surface and subsurface defects using complex amplitude of the reflected ultrasonic signals from the solid (초음파 반사신호의 복소 진폭을 이용한 교체 내부 결함의 영상 구조)

  • Kim, Hyun;Lim, Ho;Kim, Ki-Yeoul;Koo, Kil-Mo
    • The Journal of Information Technology
    • /
    • v.4 no.2
    • /
    • pp.129-136
    • /
    • 2001
  • Most of the acoustic microscopes have been constructed acoustic image by simply measuring the amplitude of the reflected signal from the specimen. This method fails to produce images of good quality because the change in amplitude is not sensitive enough to specimen with fine variation. In this paper, we have been constructed the acoustic microscope system which has been able to measure simultaneously the amplitude and phase of the reflected ultrasonic signal. And also we have been constructed the amplitude and phase images for the 500 won coin as a sample and the alumium spacimen with internal round defect, and compared and analyzed these images. In expermental result, the phase image have shown better sensitive than the amplitude image and given better contrast for the micro height variation of specimen. It will be expected that the phase image can be used as an additional bit of information to improve ambiguituities in amplitude image on nondestructive testing for specimen with fine variation.

  • PDF

A Study on Serum Ferrum, TIBC, and Ferritin's Circadian Rhythm in Normal Adults (정상 성인의 혈청 철과 TIBC 및 Ferritin의 Circadian Rhythm에 대한 연구)

  • Jeong Suk-Heui;Kim Myung-Ae
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.9 no.1
    • /
    • pp.113-122
    • /
    • 2002
  • Purpose: The purpose of this study was to identify characteristics of serum ferrum, TIBC and ferritin's circadian rhythm in normal adults and to prepare a standard to determine the examination material extraction time. Method: Nine women and ten men made up the convenience sample for this study they were from the staff of D university hospital and students in D medical School located in K city who met the qualifications for inclusion in the sample. The value of serum ferrum, TIBC and circadian rhythm were calculated as follows : First. each variable's amplitude. the acrophase and average were measured for a 24 hour cycle using the cosinor method, and then each person's rhythm was analyzed. Results: There were significant serum iron circadian rhythm for both men and women (p<.05). For the men, mesor was $105.91{\mu}g/dl$. amplitude was $29.52{\mu}g/dl$, and the acrophase was 9.76 hour. For the women, mesor was $108.17{\mu}g/dl$, amplitude was $28.09{\mu}g/dl$, and the acrophase was 11.42 hour The rhythm change of TIBC was only significant for the women (p<.05), mesor was 383.39mg/dl, amplitude was 60.29mg/dl. and the acrophase was 14.93hour. As for the circadian rhythm of the ferritin, there are no diurnal variation in either sex, men were between 134.0ng/ml and 137.4ng/ml, and women, between 29.1ng/ml and 30.1ng/ml. Conclusion: To help diagnose the boundary line between normal or deficiency in iron, measurement should be carried out at a fixed time in the morning and evening, or a more proper time would be in the afternoon at the time when the width of amplitude is the least.

  • PDF

The Effects of the Stimulation Intensity and Inter-Electrode Distance on the Parameters of the Measured Sensory Nerve Signal (전기자극의 강도와 측정전극의 간격이 감각신경신호의 파라미터에 미치는 영향 연구)

  • Lim, Kyeong Min;Song, Tongjin
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.6
    • /
    • pp.234-241
    • /
    • 2014
  • This study was designed to investigate the effects of stimulation intensity and inter-electrode distance on the parameters of the measured sensory nerve signal. 30 healthy subjects participated in this study. Sensory nerve signals were elicited by four different pulse amplitudes, i.e., 3, 6, 9, 12 mA, with the pulse width fixed at $500{\mu}s$. The sensory nerve signals elicited by the four different pulse amplitudes were measured by four different inter-electrode distances (20, 30, 40, and 50 mm). We extracted four parameters (pulse amplitude, pulse width, pulse area, and latency time from stimulation) from the sensory nerve signals. The measured pulse amplitude and pulse width were increased when the measuring inter-electrode distance was increased while the stimulating pulse amplitude was fixed. The measured pulse amplitude was saturated with the stimulating pulse amplitudes of over 6 mA while measuring inter-electrode distance. Under the same condition, measured pulse width was increased, and sensory nerve signal was initiated early. Sensory nerve signals, specially those of pulse amplitude, were distorted by a differential amplification method that commonly measures the human body signal. The experimental results indicate that the differential amplification method is required to be replaced when measuring nerve signals. Our observations suggested that the hyperpolarization of the action potential of the sensory nerve signal for preventing distortion could be used to clarify the correlation between the parameters of the sensory nerve signals and quantification of sensations.

Effect of the Tolerance Parameters of the Horn on the Vibration of the Thermosonic Transverse Bonding Flip Chip System (횡 방향 플립 칩 초음파 접합 시 혼의 공차변수가 시스템의 진동에 미치는 영향)

  • Jung, Ha-Kyu;Kwon, Won-Tae;Yoon, Byung-Ok
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.18 no.1
    • /
    • pp.116-121
    • /
    • 2009
  • Thermosonic flip chip bonding is an important technology for the electronic packaging due to its simplicity, cost effectiveness and clean and dry process. Mechanical properties of the horn and the shank, such as the natural frequency and the amplitude, have a great effect on the bonding capability of the transverse flip chip bonding system. In this research, two kinds of study are performed. The first is the new design of the clamp and the second is the effect of tolerance parameters to the performance of the system. The clamp with a bent shape is newly designed to hold the nodal point of the flip chip. The second is the effect of the design parameters on the vibration amplitude and planarity at the end of the shank. The variation of the tolerance parameters changes the amplitude and the frequency of the vibration of the shank. They, in turn, have an effect on the quantity of the plastic deformation of the gold ball bump, which determined the quality of the flip chip bonding. The tolerance parameters that give the great effect on the amplitude of the shank are determined using Taguchi's method. Error of set-up angle, the length and diameter of horn and error of the length of the shank are determined to be the parameters that have peat effect on the amplitude of the system.