• Title/Summary/Keyword: amplitude method

Search Result 2,237, Processing Time 0.03 seconds

A Study on DC Changing Algorithm of the Line-Interactive UPS with Dual Converter Structure (2중 컨버터 구조를 갖는 계통 연계형 UPS의 DC 충전 알고리듬에 관한 연구)

  • Lee, Woo-Cheol;Yoo, Dong-Sang
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.27-34
    • /
    • 2005
  • This paper presents a three phase Line-Interactive uninterruptible power supply(UPS) system with dual converter structure. The three phase UPS system consists of two active power compensator topologies. One is a series active compensator, which works as a voltage source in phase with the source voltage to have the sinusoidal source current and high power factor under the deviation and distortion of the source voltage. The other is a parallel active compensator, which works as a conventional sinusoidal voltage source in phase with the source voltage, providing to the load a regulated and sinusoidal voltage with low total harmonic distortion(THD). This paper presents in the series and parallel active compensator charging method depending on the amplitude of the source voltage. The conventional Line-Interactive UPS system is responsible for the DC charging and output voltage regulation at the same time, but UPS system with dual converter structure, a series active compensator can also charge the DC link. Therefore the charging algorithm using the series and parallel compensator needs to be researched. Therefore, by making the DC link voltage stable it can contribute the stability of series and parallel compensator. The simulation and experimental result are depicted in this paper to show the effect of the proposed algorithm.

Development of an Advanced Deformable Phantom to Analyze Dose Differences due to Respiratory Motion

  • Shin, Dong-Seok;Kang, Seong-Hee;Kim, Dong-Su;Kim, Tae-Ho;Kim, Kyeong-Hyeon;Koo, Hyun-Jae;Cho, Min-Seok;Ha, Jin-Suk;Yoon, Do-Kun;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.28 no.1
    • /
    • pp.1-10
    • /
    • 2017
  • The difference between three-dimensional (3D) and four-dimensional (4D) dose could be affected by factors such as tumor size and motion. To quantitatively analyze the effects of these factors, a phantom that can independently control each factor is required. The purpose of this study is to develop a deformable lung phantom with the above attributes and evaluate the characteristics. A phantom was designed to simulate diaphragm motion with amplitude in the range 1~7 cm and period up to ${\geq}2s$ of regular breathing. To simulate different tumors sizes, custom molds were created using a 3D printer and filled with liquid silicone. The accuracy of the phantom diaphragm motion was assessed by comparing measured motion with predicted motion. Because the phantom diaphragm motion is not identical to the tumor motion, the correlation between the diaphragm and tumor motions was calculated by a curve fitting method to emulate user-intended tumor motion. Tumors of different sizes were located at same position, and tumor set-up positions were evaluated. The accuracy of phantom diaphragm motion was better than 1 mm. The diaphragm-tumor correlation showed that the tumor motion in the superior-inferior direction increased with increasing diaphragm motion. The tumor motion was larger in the $10cm^3$ tumor than in the $90cm^3$ tumor. The range of difference between the tumor set-up positions was 0 to 0.45 cm. This phantom showed independently adjusting factors such as tumor size and motion to facilitate quantitative analysis of the dosimetric impact of respiratory motion according to these factors.

Dosimetric Effects of Intrafractional Organ Motion in Field-in-Field Technique for Whole-Breast Irradiation

  • Hong, Chae-Seon;Ju, Sang Gyu;Choi, Doo Ho;Han, Youngyih;Huh, Seung Jae;Park, Won;Ahn, Yong Chan;Kim, Jin Sung;Lim, Do Hoon
    • Progress in Medical Physics
    • /
    • v.30 no.3
    • /
    • pp.65-73
    • /
    • 2019
  • Purpose: We evaluated the motion-induced dosimetric effects on the field-in-field (FIF) technique for whole-breast irradiation (WBI) using actual patient organ motion data obtained from cine electronic portal imaging device (cine EPID) images during treatment. Materials and Methods: Ten breast cancer patients who received WBI after breast-conserving surgery were selected. The static FIF (SFIF) plan involved the application of two parallel opposing tangential and boost FIFs. To obtain the amplitude of the internal organ motion during treatment, cine EPID images were acquired five times for each patient. The outside contour of the breast (OCB) and chest wall (CW) contour were tracked using in-house motion analysis software. Intrafractional organ motion was analyzed. The dynamic FIF (DFIF) reflecting intrafractional organ motion incorporated into the SFIF plan was calculated and compared with the SFIF in terms of the dose homogeneity index (DHI90/10) for the target and V20 for the ipsilateral lung. Results: The average motion amplitudes along the X and Y directions were 1.84±1.09 mm and 0.69±0.50 mm for OCB and 1.88±1.07 mm and 1.66±1.49 mm for CW, respectively. The maximum motion amplitudes along the X and Y directions were 5.53 and 2.08 mm for OCB and 5.22 and 6.79 mm for CW, respectively. Significant differences in DHI90/10 values were observed between SFIF and DFIF (0.94 vs 0.95, P<0.05) in statistical analysis. The average V20 for the lung in the DFIF was slightly higher than that of the SFIF in statistical analysis (19.21 vs 19.00, P<0.05). Conclusion: Our findings indicate that the FIF technique can form a safe and effective treatment method for WBI. Regular monitoring using cine EPID images can be effective in reducing motion-induced dosimetric errors.

A design method for optical fiber filter of lattice structure (격자형 광파이버필터의 설계에 관한 연구)

  • 이채욱;문병현;김신환
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.9
    • /
    • pp.1248-1256
    • /
    • 1993
  • The propagation and delay properties in opical fiber are particularly attractive because digital signal processing and conventional analog signal processing techniques such as those using surface acoustic wave devices are limited In their usefulness for signal bandwidth exceeding one or two GHz, although they are very effective at lower frequencies. Since an accurate, low loss and short time delay elements can be obtained by using such an optical fiber, optical signal precessing has attracted much attention for high speed and broad-band signal precessing in particular channel separation filtering for optical FDM signals. In this paper, we consider a coherent optical lattice filter, which uses coherent light sources and consists of directional couplers and optical fiber delay elemnts. The optical fiber fitters are more restricted than the usual digital filters. The reasons are as follows. 1) the coupling coefficients of directional couplers are restricted to the number between 0 and 1. 2) optical signal E(complex amplitude) is divided into J If-$\boxUl$ and J L/7$\div$$\boxUl$ at the directional coupler. Considering these restrictions and in this case all the coupling coefficients of summing and branching elements are set to be equal, we have given design formulae for optical lattice filter, which make the best use of optical signal energy.

  • PDF

Analysis of Optimum Design of Stepped Bar Horn for 20kHz Metal Ultrasonic Welding (20kHz 급 금속 초음파 융착용 스텝형 바 혼의 최적설계)

  • Kim, Jisun;Kim, Jaewoong;Kim, In-ju;Seo, Joowhan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.94-101
    • /
    • 2019
  • In this study, the FEM technique was applied to design the shape of the horn that transmits ultrasonic vibration energy to the base material, and the shape of the welding horn with a one-wavelength bar shape used in the 20kHz region was designed. The shape design of the horn was performed by applying the rod longitudinal vibration theory to Ansys APDL (Ansys Parametric Design Language). Twenty-five models were designed using the ratio of the area of the input and output surfaces of the vibration and the length of the horn to derive the appropriate horn shape. The horn was designed with a total length of 130mm, a step length of 65mm, and an output area of 28.79mm. The horn was fabricated using the optimized dimensions, and the vibration and displacement characteristics of the horn were evaluated using the measurement system. Finally, a uniform longitudinal step horn was designed, and more than 97.4% of the uniformity of the tip was secured. The amplitude ratio of the optimized horn was improved by 51%.

Laryngeal Findings and Phonetic Characteristics in Prelingually Deaf Patients (언어습득기 이전 청각장애인의 후두소견 및 음성학적 특성)

  • Kim, Seong-Tae;Yoon, Tae-Hyun;Kim, Sang-Yoon;Choi, Seung-Ho;Nam, Soon-Yuhl
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.20 no.1
    • /
    • pp.57-62
    • /
    • 2009
  • Background and Objectives : There are few studies reported that specifically examine the laryngeal function in patients with profound hearing loss or deafness, This study was designed to examine videostroboscopic findings and phonetic characteristics in adult patients with prelingually deaf. Materials and Method: Sixteen patients (seven males, nine females) diagnosed as prelingually deaf aged from 19 to 54 years, and were compared with a 20 normal control group with no laryngeal pathology and normal hearing group, Videostroboscopic evaluations were rated by experienced judges on various parameters describing the structure and function of the laryngeal mechanism during comfortable pitch and loudness phonations. Acoustic analysis test were done, and a nasalance test performed to measure rabbit, baby, and mother passage. CSL were measured to determine the first and two formant frequencies of vowels /a/, /i/, /u/, Statistical analysis was done using Mann-Whitney U or Wilcoxon signed ranks test. Results: Videostroboscopic findings showed phase symmetry but significantly more occurrences decrement in the amplitude of vibration, mucosal wave, irregularity of the vibration and increased glottal gap size during the closed phase of phonation, In addition, group of prelingually deaf patients were observed to have significantly more occurrences of abnormal supraglottic activities during phonation. The percentage of shimmer in the group of prelingually deaf patients were higher than in the control group. Characteristics of vowels were lower of the second formant of the vowel /i/. Nasalance in prelingually deaf patients showed normal nasality for all passages, Conclusion: Prelingually deaf patients show stroboscopic abnormal findings without any mucosal lesion, suggesting that they have considerable functional voice disorder. We suggest that prelingually deaf adults should perform vocal training for normalized laryngeal function after cochlear implantation.

  • PDF

Comparison of Tillage and Loads Characteristics of Three Types of Rotavators: Rotary-type, Crank-type, and Plow-type

  • Kim, Myoung-Ho;Nam, Ju-Seok;Kim, Dae-Cheol
    • Journal of Biosystems Engineering
    • /
    • v.38 no.2
    • /
    • pp.73-80
    • /
    • 2013
  • Purpose: This study was conducted to compare tillage and loads characteristics of three types of rotavators in farmland working condition of Korea. Methods: Tillage operations using three types of rotavators, i.e. rotary-type, crank-type and plow-type, were carried out in a dry field of Korea. The same prime mover tractor was used for driving three types of rotavators, and under several operational conditions, tillage characteristics such as actual working speed, rotavating depth, rotavating width, actual field capacity, flow of tilled soil, soil inversion ratio, and pulverizing ratio were measured. In addition, loads characteristics like torque and required power of Power Take-Off (PTO) shaft were calculated. Results: The average rotavating depth was smaller than the nominal value for all rotavators, and the difference was the greatest in the plow-type rotavator. Nevertheless, the plow-type rotavator showed the largest rotavating depth. The rotavating width was the same as the nominal value of all rotavators. The flow of tilled soil at the same operational conditions was the greatest in the plow-type rotavator and was the smallest in the rotary-type rotavator. In the most commonly used gear conditions of L2 and L3, the average soil pulverizing ratio was the greatest in the rotary-type rotavator, and followed by crank-type and plow-type rotavators in order. In the gear L2 and L3, the plow-type rotavator also had the lowest average soil inversion ratio while the rotary-type and crank-type rotavators had the same soil inversion ratio each other. The average torque and power of PTO shaft in the gear L2 and L3 were the highest in the plow-type rotavator. The load spectra of PTO shaft applying rain flow counting method and Smith-Waston-Topper equation to the measured torque showed that the modified torque amplitude was the greatest in the crank-type rotavator. This may come from the large torque fluctuation of crank-type rotavator during tillage operations. Conclusions: The three types of rotavators had different tillage and loads characteristics. The plow-type rotavator had the deepest rotavating depth, the smallest soil inversion ratio, the largest soil pulverizing ratio and required PTO power. Also, the crank-type rotavator showed a large torque fluctuation because of their unique operational mechanism. This study will help the farmers choose a suitable type of rotavator for effective tillage operations.

Development of a Stress ECG Analysis Algorithm Using Wavelet Transform (웨이브렛 변환을 이용한 스트레스 심전도 분석 알고리즘의 개발)

  • 이경중;박광리
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.269-278
    • /
    • 1998
  • This paper describes a development of efficient stress ECG signal analysis algorithm. The algorithm consists of wavelet adaptive filter(WAF), QRS detector and ST segment detector. The WAF consists of a wavelet transform and an adaptive filter. The wavelet transform decomposed the ECG signal into seven levels using wavelet function for each high frequency bank and low frequency bank. The adaptive filter used the signal of the seventh lowest frequency band among the wavelet transformed signals as primary input. For detection of QRS complex, we made summed signals that are composed of high frequency bands including frequency component of QRS complex and applied the adaptive threshold method changing the amplitude of threshold according to RR interval. For evaluation of the performance of the WAF, we used two baseline wandering elimination filters including a standard filter and a general adaptive filter. WAF showed a better performance than compared filters in the noise elimination characteristics and signal distortion. For evaluation of WAF showed a better performance than compared filters in the noise elimination characteristics and signal distortion. For evaluation of results of QRS complex detection, we compared our algorithm with existing algorithms using MIT/BIH database. Our algorithm using summed signals showed the accuracy of 99.67% and the higher performance of QRS detection than existing algorithms. Also, we used European ST-T database and patient data to evaluate measurement of the ST segment and could measure the ST segment adaptively according to change of heart rate.

  • PDF

Usefulness of Direct Cortical Stimulation During Intraoperative Monitoring in Patients with Brain Tumor Near Motor Cortex: Case Report (운동피질영역 주변의 뇌종양 환자에서 수술 중 직접피질자극 검사의 유용성)

  • Lim, Sung-Hyuk;Park, Sang-Ku;Kim, Dong-Jun;Baek, Jae-Seung;Park, Chan-Woo
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.2
    • /
    • pp.211-215
    • /
    • 2018
  • The aim of this study was to preserve the corticospinal tract during surgery and assess more accurately the motor performance in brain tumor patients around the motor cortex. TceMEP is not entirely reliable, even though there has been no change in waveforms due to a mixture of false positive and false negative signals. For a more detailed examination, DCS was employed to selectively stimulate the motor cortex. In both cases, the indications could find the region to which the cortex was responsible, and constantly check and examine the changes in amplitude, thereby preserving the motor pathway and performing surgery. On the other hand, patients who did not implement the DCS but did implement the TceMEP experienced a decrease in their postoperative motor performance. DCS is a very useful examination and it is a method that can reduce the post-surgery disorder that may occur in patients with the TceMEP in brain tumor surgery.

Application of Image Processing Techniques to GPR Data for the Reliability Improvement in Subsurface Void Analysis (지표레이더(GPR) 탐사자료를 이용한 지하공동 분석 시 신뢰도 향상을 위한 영상처리기법의 활용)

  • Kim, Bona;Seol, Soon Jee;Byun, Joongmoo
    • Geophysics and Geophysical Exploration
    • /
    • v.20 no.2
    • /
    • pp.61-71
    • /
    • 2017
  • Recently, ground-penetrating radar (GPR) surveys have been actively carried out for precise subsurface void investigation because of the rapid increase of subsidence in urban areas. However, since the interpretation of GPR data was conducted based on the interpreter's subjective decision after applying only the basic data processing, it can result in reliability problems. In this research, to solve these problems, we analyzed the difference between the events generated from subsurface voids and those of strong diffraction sources such as the buried pipeline by applying the edge detection technique, which is one of image processing technologies. For the analysis, we applied the image processing technology to the GRP field data containing events generated from the cavity or buried pipeline. As a result, the main events by the subsurface void or diffraction source were effectively separated using the edge detection technique. In addition, since subsurface voids associated with the subsidence has a relatively wide scale, it is recorded as a gentle slope event unlike the event caused by the strong diffraction source recorded with a sharp slope. Therefore, the directional analysis of amplitude variation in the image enabled us to effectively separate the events by the subsurface void from those by the diffraction source. Interpretation based on these kinds of objective analysis can improve the reliability. Moreover, if suggested techniques are verified to various GPR field data sets, these approaches can contribute to semiautomatic interpretation of large amount of GPR data.