• 제목/요약/키워드: amplitude method

Search Result 2,237, Processing Time 0.027 seconds

A Method for Separating Volterra Kernels of Nonlinear Systems by Use of Different Amplitude M-sequences

  • Harada, Hiroshi;Nishiyama, Eiji;Kashiwagi, Hiroshi;Yamaguchi, Teruo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1998.10a
    • /
    • pp.271-274
    • /
    • 1998
  • This paper describes a new method for separation of the Volterra kernels which are identified by use of M-sequence. One of the authors has proposed a method for identification of Volterra kernels of nonlinear systems using M-sequence and correlation technique. When M-sequence are applied to a nonlinear systems, the cross-correlation function between the input and the output of the nonlinear systems includes cross-sections of high-order Volterra kernels. However, if various order Volterra kernels exixt on the obtained cross-correlation function, it is difficult to separate the Volterra kernels. In this paper, the authors show that the magnitude of Volterra kernels is maginified by the amplitude of M-sequence according to the order of Volterra kernels. By use of this property, each order Volterra kernels is obtained by solving linear equations. Simulations are carried out for some nonlinear systems. The results show that Volterra kernels can be separated in each order successfully by the proposed method.

  • PDF

Impact localization method for composite structures subjected to temperature fluctuations

  • Gorgin, Rahim;Wang, Ziping
    • Smart Structures and Systems
    • /
    • v.30 no.4
    • /
    • pp.371-383
    • /
    • 2022
  • A novel impact localization method is presented based on impact induced elastic waves in sensorized composite structure subjected to temperature fluctuations. In real practices, environmental and operational conditions influence the acquired signals and consequently make the feature (particularly Time of Arrival (TOA)) extraction process, complicated and troublesome. To overcome this complication, a robust TOA estimation method is proposed based on the times in which the absolute amplitude of the signal reaches to a specific amplitude value. The presented method requires prior knowledge about the normalized wave velocity in different directions of propagation. To this aim, a finite element model of the plate was built in ABAQUS/CAE. The impact location is then highlighted by calculating an error value at different points of the structure. The efficiency of the developed impact localization technique is experimentally evaluated by dropping steel balls with different energies on a carbon fiber composite plate with different temperatures. It is demonstrated that the developed technique is able to localize impacts with different energies even in the presence of noise and temperature fluctuations.

An ACLMS-MPC Coding Method Integrated with ACFBD-MPC and LMS-MPC at 8kbps bit rate. (8kbps 비트율을 갖는 ACFBD-MPC와 LMS-MPC를 통합한 ACLMS-MPC 부호화 방식)

  • Lee, See-woo
    • Journal of Internet Computing and Services
    • /
    • v.19 no.6
    • /
    • pp.1-7
    • /
    • 2018
  • This paper present an 8kbps ACLMS-MPC(Amplitude Compensation and Least Mean Square - Multi Pulse Coding) coding method integrated with ACFBD-MPC(Amplitude Compensation Frequency Band Division - Multi Pulse Coding) and LMS-MPC(Least Mean Square - Multi Pulse Coding) used V/UV/S(Voiced / Unvoiced / Silence) switching, compensation in a multi-pulses each pitch interval and Unvoiced approximate-synthesis by using specific frequency in order to reduce distortion of synthesis waveform. In integrating several methods, it is important to adjust the bit rate of voiced and unvoiced sound source to 8kbps while reducing the distortion of the speech waveform. In adjusting the bit rate of voiced and unvoiced sound source to 8 kbps, the speech waveform can be synthesized efficiently by restoring the individual pitch intervals using multi pulse in the representative interval. I was implemented that the ACLMS-MPC method and evaluate the SNR of APC-LMS in coding condition in 8kbps. As a result, SNR of ACLMS-MPC was 15.0dB for female voice and 14.3dB for male voice respectively. Therefore, I found that ACLMS-MPC was improved by 0.3dB~1.8dB for male voice and 0.3dB~1.6dB for female voice compared to existing MPC, ACFBD-MPC and LMS-MPC. These methods are expected to be applied to a method of speech coding using sound source in a low bit rate such as a cellular phone or internet phone. In the future, I will study the evaluation of the sound quality of 6.9kbps speech coding method that simultaneously compensation the amplitude and position of multi-pulse source.

Deep Learning Based Digital Staining Method in Fourier Ptychographic Microscopy Image (Fourier Ptychographic Microscopy 영상에서의 딥러닝 기반 디지털 염색 방법 연구)

  • Seok-Min Hwang;Dong-Bum Kim;Yu-Jeong Kim;Yeo-Rin Kim;Jong-Ha Lee
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.23 no.2
    • /
    • pp.97-106
    • /
    • 2022
  • In this study, H&E staining is necessary to distinguish cells. However, dyeing directly requires a lot of money and time. The purpose is to convert the phase image of unstained cells to the amplitude image of stained cells. Image data taken with FPM was created with Phase image and Amplitude image using Matlab's parameters. Through normalization, a visually identifiable image was obtained. Through normalization, a visually distinguishable image was obtained. Using the GAN algorithm, a Fake Amplitude image similar to the Real Amplitude image was created based on the Phase image, and cells were distinguished by objectification using MASK R-CNN with the Fake Amplitude image As a result of the study, D loss max is 3.3e-1, min is 6.8e-2, G loss max is 6.9e-2, min is 2.9e-2, A loss max is 5.8e-1, min is 1.2e-1, Mask R-CNN max is 1.9e0, and min is 3.2e-1.

Evaluation of Delamination of Dental Composite Restoration using Infrared Lock-in Thermography (열화상 기술을 이용한 치아/복합레진 수복부의 박리 평가)

  • Gu, Ja-Uk;Choi, Nak-Sam
    • Composites Research
    • /
    • v.25 no.6
    • /
    • pp.236-240
    • /
    • 2012
  • The purpose of this study was to investigate the feasibility on the detection of dental composite delamination using a lock-in thermography method. Amplitude and phase images of detected thermal signals were analyzed according to the lock-in frequencies. At a lock-in frequency of 0.05 Hz, the ligament thickness of 0.5 mm in the specimen exhibited the highest amplitude contrast between defective area and sound area. For ligament thicknesses of 1 mm and 1.5 mm, delamination detection was possible at 0.025 Hz and 0.01 Hz through the amplitude differences. At lock-in frequencies of 0.006 Hz and 0.01 Hz, ligament thickness 0.5 mm exhibited the highest phase contrast. For ligament thicknesses of 1 mm and 1.5 mm, the phase contrast exhibited possible detection of delamination at 0.006-0.1 Hz.

Effects of Ultrasonic Amplitude on Electrochemical Properties During Cavitation of Carbon Steel in 3.5% NaCl Solution

  • Jang, I.J.;Kim, K.T.;Yoo, Y.R.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.163-173
    • /
    • 2020
  • Cavitation corrosion in many industrial plants has recently become a serious issue. Cavitation corrosion has generally been investigated using a vibratory method based on ASTM G32 standard, and the test can be divided into direct cavitation and indirect cavitation. Cavitation corrosion test uses the vibration frequency of the horn of 20 kHz with constant peak-to-peak displacement amplitude. In this work, the peak-to-peak amplitude was controlled from 15 ㎛ to 85 ㎛, and electrochemical measurements were obtained during indirect cavitation. The relationship between cavitation corrosion rate and electrochemical properties was discussed. Corrosion steps of carbon steel at the initial stage under cavitation condition in 3.5 % NaCl can be proposed. When the cavitation strength is relatively low, corrosion of the steel is more affected by the electrochemical process than by the mechanical process; but when the cavitation strength is relatively high, corrosion of the steel is affected more by the mechanical process than by the electrochemical process. This work confirmed that the critical ultrasonic amplitude of 0.42 %C carbon steel is 53.8 ㎛, and when the amplitude is less than 53.8 ㎛, the corrosion effect during the cavitation corrosion process is higher than the mechanical effect.

Vibration Characteristics and the Serviceability Evaluation of High-rise Building during Strong Wind (강풍시 고층건물의 진동특성 및 사용성 평가)

  • Yoon, Sung-Won;Kim, Do-Hyun;Jeong, Sug-Chang;Kim, Dong-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.5
    • /
    • pp.57-65
    • /
    • 2007
  • After measuring wind induced response for a high-rise steel building, the damping ratio and natural frequency were analyzed in this paper. In order to examine amplitude dependence, random decrement method was used. Two methods were analyzed by comparing dynamic properties from random decrement method and half powered-band width method. In addition, through serviceability evaluation during strong wind, compatibility of two methods to Japanese guidelines for the evaluation of habitability to building vibration and national building code of Canada was considered. The amplitude dependence of the damping ratio by RD method was shown and the amplitude dependence of the natural frequency was relatively very small in an aspect of engineering sense. Moreover, the measured building was satisfied with serviceability and Japanese guideline is stricter than NBCC code.

  • PDF

Highly-sensitive Magnetic Sensor using the Amplitude-Modulation (진폭변조를 이용한 고감도 자기센서)

  • 이상훈;남태철
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.05a
    • /
    • pp.90-95
    • /
    • 1995
  • This paper describes the highly-sensitive Si magnetic sensor using the amplitude modulation in order to real ice the integrated magnetic sensor which to sensor a weak magnetic field. Generally, the most important two parameters in Hall IC which degrade the ability of magnetic detection are the variation of offset according to the variation of temperature and the noise of amplifiers. In this paper, we use a Hall element and compensator to reduce the offset and the nouse of amplifiers by Using amplititude modulation method.

  • PDF

Enhancement on Time-of-Flight Camera Images (Time-of-Flight 카메라 영상 보정)

  • Kim, Sung-Hee;Kim, Myoung-Hee
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.708-711
    • /
    • 2008
  • Time-of-flight(ToF) cameras deliver intensity data as well as range information of the objects of the scene. However, systematic problems during the acquisition lead to distorted values in both distance and amplitude. In this paper we propose a method to acquire reliable distance information over the entire scene correcting each information based on the other data. The amplitude image is enhanced based on the depth values and this leads depth correction especially for far pixels.

  • PDF

Vibratory pattern analysis of vocal folds for layngeal function assessment usig electroglottograph system

  • Song, Chulgyu;Lee, Myoungho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1994.10a
    • /
    • pp.583-585
    • /
    • 1994
  • In this study, we have evaluated the effect of amplitude and frequency perturbation of EGG signal during single vowels associated with laryngeal pathology. The normal EGG signal is properly characterized by an autoregressive model which has the optimal order of ninth using the parametric method. This can be analyzed by determining the transfer function. Perturbations in the fundamental pitch and in the peak amplitude of EGG signal derived with a four-electrode system using the modulation/demodulation techniques were investigated for the purpose of developing a decision criteria for the laryngeal function identification.

  • PDF