• 제목/요약/키워드: amplitude difference

검색결과 650건 처리시간 0.034초

비대칭무게중심을 지닌 물체 들기 작업시 허리부위 등근육 부하 및 피로 분석 (The Analysis of Low Back Loading and Muscle Fatigue while Lifting an Asymmetric Load)

  • 한승조;김선욱
    • 산업경영시스템학회지
    • /
    • 제35권2호
    • /
    • pp.30-36
    • /
    • 2012
  • This study is aimed to show that an asymmetric load in the frontal plane leads to an increase in low back loading and fatigue in comparison with a symmetric load when workers lift an external weight by investigating previous studies and verifying the phenomenon with an experiment. Ten male subjects are required to lift and hold an given external load at 70cm height during 50sec, then the EMG amplitude and median frequency on bilateral low back muscle groups (Longissimus, Iliocostalis, and Multifidus) are recorded and analyzed. Independent variables are two-level load weight (13kg, 20kg) and three-level LCG (Center, 6.5cm to the right, and 13cm to the right), and dependent variables are EMG amplitude average, difference, and Fatigue Index (FI). Results show that load weight increases significantly amplitude average and FI, but LCG does significantly amplitude difference and FI significantly (P-value < 0.05). Also the correlation coefficient between amplitude difference and FI is over 0.99. These implies that trunk loading should be explained by not EMG amplitude but muscle fatigue aspect since the association between an external load and amplitude is linear, but the relationship between an external load and median frequency as muscle fatigue index is almost exponential.

청.장년층에서 조절력 및 조절반응과 조절용이의 상관관계에 관한 임상적 연구 (A Clinical Study on Relation among Accommodative Amplitude, Response, and Facility in young adults)

  • 심현석;주석희;임현성
    • 한국안광학회지
    • /
    • 제14권1호
    • /
    • pp.115-119
    • /
    • 2009
  • 목적: 본 연구는 조절력 및 조절반응과 조절용이의 상관관계를 알아보고자 하였다. 방법: 특별한 안질환이 없고 노안이 진행되지 않는 20~40대의 성인 남녀 61명을 대상으로 하였다. 원거리시력을 완전교정한 후 조절력은 Push-Up 방법으로 검사하였고, 조절반응량검사와 조절용이성 검사는 각각 잭슨크로스실린더 ${\pm}$0.25D와 flipper +2.00/-2.00D를 이용하였다. 결과: 단안, 양안시 상태에서 조절력과 조절반응, 조절용이의 상관관계는 유의성이 없었으며, 양안시 상태에서 기대값과 다르게 나타난 안구의 수는 총 61안 중 23안(37.7%)로 이들 중 조절력이 12안(19.6%), 조절반응이 9안(14.7%), 조절용이가 2안(3.2%)으로 나타났고, 조절력과 조절반응이 동시에 나타난 경우가 4안(6.5%), 조절력과 조절용이가 동시에 나타난 경우는2안(3.2%), 조절력과 조절반응, 조절용이 3가지 모두 기대값과 다르게 나타난 경우는 없었다. 결론: 조절기능 평가 시 조절력검사와 조절반응검사, 조절용이성 검사는 각각 시행되어야 하며 조절기능의 결함이 의심 될 때에는 이들 항목의 평가가 반드시 필요하다.

  • PDF

순간주파수 분석기법의 응용 (2) -주파수의 부호를 결정하는 조건- (Application of Instantaneous Frequency Analysis(II) -Conditions of Existing Negative Frequency Components-)

  • 김정태;임병덕
    • 대한기계학회논문집
    • /
    • 제18권4호
    • /
    • pp.1057-1063
    • /
    • 1994
  • An instantaneous frequency analysis is a technique to examine a signature for the rotating machinery if the signal has several transitions within a cycle. This paper discusses the conditions of existing negative frequency components in the instantaneous frequency. By using a signal consisted of two frequency components, the instantaneous frequency analysis is conducted while the amplitude ratio between two frequency components has been changed. The analysis shows that, depending on the amplitude ratio, the instantaneous frequencies have averaged, zero-valued, or negative components. It turns out that the negative-valued instantaneous frequencies, which have been regarded as the noise effect, are the consequence of the calculation process for the multisignal components. The criteria of existing the negative values in instantaneous frequencies is given in terms of the relative amplitude ratio and the frequency difference. Especially when the amplitude ratio approaches to 1, the instantaneous frequency fluctuates ${\pm}\infty$ in theory, which implies that instantaneous frequency has unstable region around the amplitude ratio, 1.Also, as the frequency difference between major signal components is increased, the region of existing negative instantaneous becomes broader. In an instantaneous frequency analysis, therefore, a narrow band analysis is suggested, with extreme care if the amplitude ratio approaches to 1. In this paper, a vibration signal monitored from a rotating machinery is also examined as an application example in order to show the existence of negative instantaneous frequencies components.

Effect of axial stretching on large amplitude free vibration of a suspended cable

  • Chucheepsakul, Somchai;Wongsa, Sanit
    • Structural Engineering and Mechanics
    • /
    • 제11권2호
    • /
    • pp.185-197
    • /
    • 2001
  • This paper presents the effect of axial stretching on large amplitude free vibration of an extensible suspended cable supported at the same level. The model formulation developed in this study is based on the virtual work-energy functional of cables which involves strain energy due to axial stretching and work done by external forces. The difference in the Euler equations between equilibrium and motion states is considered. The resulting equations govern the horizontal and vertical motion of the cables, and are coupled and highly nonlinear. The solution for the nonlinear static equilibrium configuration is determined by the shooting method while the solution for the large amplitude free vibration is obtained by using the second-order central finite difference scheme with time integration. Numerical examples are given to demonstrate the vibration behaviour of extensible suspended cables.

진폭비 불일치에 의한 cross-eye 재밍 성능: 각도 추적 오차 성능 분석 비교 (Performance of cross-eye jamming due to amplitude mismatch: Comparison of performance analysis of angle tracking error)

  • 김제안;김진성;이준호
    • 융합정보논문지
    • /
    • 제11권11호
    • /
    • pp.51-56
    • /
    • 2021
  • 본 논문에서는 cross-eye의 두 재밍 안테나의 진폭 불일치로 인한 성능 저하를 고려한다. 진폭비의 불일치는 기계적 결함에 따른 실제 진폭비와 명목상 진폭비의 차이가 정규분포를 갖는 랜덤변수로 모델링한다. 1차 테일러 전개와 2차 테일러 전개를 통한 해석적 성능분석이 제안된다. 실제 진폭비와 명목상 진폭비의 불일치가 발생한 Cross-eye 재밍의 성능 측정은 mean square difference (MSD)를 계산함으로서 측정된다. 해석적으로 유도된 MSD는 1차 테일러 전개 기반 시뮬레이션 기반 MSD 및 2차 테일러 전개 기반 시뮬레이션 기반 MSD와 해석 기반 MSD와 비교함으로써 검증된다. 계산비용이 높은 Monte-Carlo기반 MSD보다 해석 기반 MSD가 우수함을 보인다.

Fluttering Characteristics of the Ropes and Nets as an Active Stimulating Device inside the Cod End of a Trawl Net

  • Kim, Yong-Hae
    • Fisheries and Aquatic Sciences
    • /
    • 제16권2호
    • /
    • pp.101-108
    • /
    • 2013
  • An active stimulating device (ASD) consisting of a net panel or ropes fluttering in the turbulence inside the cod end was effective in driving fish near the cod end to reduce juvenile by-catch. The fluttering characteristics of the rope and net panel were examined by video observations and analyzed for fluttering amplitude and period in a water channel and in field experiments with a bottom trawl. The amplitude ratio of the fluttering ropes or nets in the tank test increased with the fluttering index as the diameter of the twine, mesh size, flexibility, and flow velocity changed, whereas the period decreased with the above factors. In bottom trawl experiments, the range of mean depth difference in the fluttering net panel was 12-17% of the length of the fluttering net, and the period of depth difference or three-dimensional (3D) tilt was revealed, with shorter ones ranging from 2 to 6 s. The amplitude as depth difference and period from field measurements were similar to those of nets in tank experiments and also to the period of 3D flow velocity inside the cod end. These results could be used to design an ASD that could be used for to the cod end of actual towed fishing gear to reduce juvenile by-catch.

수직 진동을 동반한 Leg Press 운동 시 진동 크기와 주파수에 따른 하지 근육의 근전도 차이 분석 (Difference in sEMG on lower extremity during leg press exercise with whole body vibration with various amplitude and frequency)

  • 최진승;김용준;강동원;문경률;탁계래
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1492-1495
    • /
    • 2008
  • As a prerequisite of developing muscle biofeedback system which can simulate analogous isokinetic exercise, the purpose of this study was to study the effects of frequency and amplitude of whole-body vibration on the difference in sEMG on lower extremities during leg press exercise with/without vibration. The amplitude of vibration was set to 20, 50, 80 and the frequency of vibration was set to 10, 20, 30, and 50 Hz. EMG were measured at Vastus lateralis muscle and Vastus medialis muscle. MP100 EMG module(BIOPAC system Inc., USA) was used for EMG measurement. The result showed that the combination of frequency of 30Hz and amplitude of 50 had more activated EMG than other combination with relatively small work load (30kg). It is necessary to experiment the frequency between 20 and 40Hz in detail, and to normalize sEMG using maximal voluntary contraction (MVC).

  • PDF

한국어 장애음의 강도 특성 (Intensity Characteristics of Korean Obstruents)

  • 박한상
    • 대한음성학회지:말소리
    • /
    • 제47호
    • /
    • pp.73-84
    • /
    • 2003
  • This study investigates differences in intensity across the three different Korean obstruent types in terms of the RMS amplitude of both the entire section and the first 512 samples of the immediately following vowel in two positions. The results showed that for the utterance initial position the RMS amplitude of both the entire section and the first 512 samples of the vowel was greatest for fortis obstruents, intermediate for aspirated ones, and weakest for lenis ones, with a significant difference between each pair of them. For the intervocalic position, in contrast, the intensity of the entire vowel was greatest for fortis obstruents, intermediate for lenis ones, and weakest for aspirated ones, with no significant difference between the last two groups, whereas the intensity of the first 512 samples of the vowel was greatest for fortis obstruents, intermediate for lenis ones, and weakest for aspirated ones, with a significant difference between each pair of the three groups. This means that the intensity of the earlier part of the vowel functions as a discriminator of Korean obstruents. The positional difference is due to the different behavior of the lenis obstruents in the intervocalic position, such that the intensity build-up is already on its way with voice lead.

  • PDF

THE EFFECT OF INTENSITY ON DURATION DISCRIMINATION

  • Jeon, J.Y.;Fricke, F.R.
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1994년도 FIFTH WESTERN PACIFIC REGIONAL ACOUSTICS CONFERENCE SEOUL KOREA
    • /
    • pp.879-884
    • /
    • 1994
  • This paper reports on several experiments carried out to find the effects of intensity difference on duration discrimination in pairs of pure tones. Pure-tone signals were presented with the modification of amplitude and duration. Duration-discrimination thresholds for the musical tones and the signals that were varied in amplitude were investigated together with those of the fixed signals. From the results, it was found that the duration discrimination tasks are affected by an intensity difference of 20 phons.

  • PDF

어깨뼈 익상에 대한 푸쉬업플러스 시 부가적 진동의 주파수와 진폭이 어깨안정근 근활성도에 미치는 영향 (The Effects of Vibration Frequency and Amplitude on Serratus Anterior Muscle Activation During Knee Push-up Plus Exercise in Individuals with Scapular Winging)

  • 박원영;구현모
    • 대한물리의학회지
    • /
    • 제13권4호
    • /
    • pp.67-74
    • /
    • 2018
  • PURPOSE: This study was conducted to investigate the effects of vibration frequency and amplitude on scapular winging during the knee push-up plus exercise. METHODS: A total of 26 female subjects with scapular winging were evaluated while performing the knee push-up plus exercise with no vibration, low-frequency/low-amplitude (5 Hz/3 mm) vibration, low-frequency/high-amplitude (5 Hz/9 mm) vibration, high-frequency/low-amplitude (15 Hz/3 mm) vibration, and high-frequency/high-amplitude (15 Hz/9 mm) vibration. The surface EMG of the serratus anterior (SA) muscle was compared between the vibration frequency and amplitude. The EMG amplitude was normalized using the maximal voluntary isometric contraction (MVIC). The statistical significance of the results was evaluated using one-way ANOVA. RESULTS: The SA muscle EMG values increased at low-frequency/low-amplitude vibration and at low-frequency/high-amplitude vibration compared to no vibration. Furthermore, the same values increased at high-frequency/low-amplitude vibration and high-frequency/high-amplitude vibration compared to no vibration. In general, a higher vibration frequency and amplitude was associated with higher EMG values of the SA muscle, with particularly greater increases observed during high-frequency/high-amplitude vibration. There was also a significant difference between each condition with a high-frequency/high-amplitude vibration (p<.05). CONCLUSION: This study suggests that there were remarkable clinical effect of the knee push-up plus exercise with vibration, which enhanced the SA muscle activation in persons with scapular winging. Furthermore, applying a higher vibration frequency and amplitude more effectively increased for increasing SA muscle activation.