• Title/Summary/Keyword: ambient air temperature

Search Result 566, Processing Time 0.026 seconds

Gas-Particle Partitioning of PCBs in Ambient Air, Yokohama Japan (일본 요코하마 대기 중 PCBs의 가스-입자 분배)

  • Kim Kyoung-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.3
    • /
    • pp.285-293
    • /
    • 2005
  • This study was aimed at estimation of gas-particle partitioning of polychlorinated biphenyls (PCBs) in ambient air. The samples were collected at urban site in Japan from March 2002 to January 2003. The concentration of total PCBs (from 4 CB to 10 CB) and TEQ (Toxic equivalent) ranged from 62 to $247\;pg/m^3$ and from 2 to $14\;fgTEQ/m^3 $, respectively. The average contribution $(\%)$ of gas phase to total PCBs concentration was above $80\%$, which suggests that in the atmosphere PCBs predominantly existed in the gas phase. The weak correlations between total PCBs concentration and temperature was found. However this result was due to a typhoon during summer and raining during sampling period. The gas-particle partition coefficient (Kp) was obtained as a function of temperature. The partition ratio of gaseous and particulate phase PCBs can be estimated for an arbitrary temperature. The plot of gas/particle partition coefficient (log Kp) vs. sub-cooled liquid vapor pressure $(log\;P_L)$ had reasonable correlations for individual samples but the slope varied among the samples (coefficients of determination for log Kp versus log $P_L$ plot were> 0.76 $(p<0.0001)$, except for 3 samples). As a result, the variations in the slope among the sampling period may be due to change of temperature, raining during sampling period and wind in this study.

Using Ambient Control to Prevent External Disturbances in Large-scale Furnace (대형 용해로의 외부 환경변수를 통제하기 위한 주변 환경관리의 활용)

  • Cho, Jin-Hyung;Chang, Sung-Ho;Lee, Sae-Jae;Jang, Do-Soo;Suh, Jung-Yul;Oh, Hyun-Seung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.29 no.2
    • /
    • pp.92-96
    • /
    • 2006
  • Large glass furnaces to produce glass for CRT are housed in huge chambers. It is costly to maintain such a chamber in constant temperature, humidity, and(air) pressure. In this study, first, we show that the process of such a huge furnace, which requires the steady maintenance of high temperature, is badly affected by the ambient temperature of surrounding air. Second, an alternative process which not only maintains the relatively constant temperature dispersion around the furnace, but is also economical will be proposed. We calculate the necessary volume of air inflow in the appendix.

Assessment of clothing ventilation by a trace gas method (Trace gas법에 의한 의복의 환기 양상의 평가)

  • 추미선
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.21 no.8
    • /
    • pp.1387-1395
    • /
    • 1997
  • Effects of the ambient air temperature and the opening position on the pattern of the clothing ventilation of a thermal manikin wearing an impermeable blouse were investigated by the trace gas method. Under an isothermal condition, the ventilation was governed by diffusion, and the ventilation rate through the wrist-openings was greatly affected by the distance from the openings. Under non-isothermal conditions, however, the ventilation was accelerated by the convection driven by the temperature gradient between the clothing microclimate and the surrounding air; the greater the temperature gradient, the greater the ventilation. Even though it was certainly affected by the ambient air temperature, the ventilation rate was more significantly influenced by the position of openings. The ventilation patterns at the arm and the body were distinctive.

  • PDF

Characteristics of Ondol Heating Load for the Determination of Heat Pump Power (열펌프 시스템의 규모 결정을 위한 온돌난방부하 특성)

  • 노정근;백은기;송현갑
    • Journal of Biosystems Engineering
    • /
    • v.28 no.3
    • /
    • pp.217-224
    • /
    • 2003
  • To find out heating load and to determine the power of heat pump compressor for the Ondol room heating the COP of heat pump, the variation of Ondol room air temperature, the variation of ambient temperature and power consumption of heat pump are analyzed. The results from this study were summarized as follows: 1. The COP of the heat pump in close loop decreased as the ambient air temperature. The COP was 2.26 when the temperature difference of condenser was $20\pm3^{\circ}C$. 2. The Ondol surface temperature was $25\pm3^{\circ}C$ when the hot water of $40^{\circ}C$ was supplied from hot water storage tank to the Ondol and the temperature difference between the Ondol surface and the room air temperature was $7~8^{\circ}C$. 3. The ratio of thermal conduction heating load to total heating load in Ondol heating space was found to be 83% and ratio of ventilation heating load was 17%. Therefore, the thermal conduction heating load was confirmod to be a major heating load in Ondol heating space. 4. In case of the ambient temperature of $3.2^{\circ}C$, the efficiency of heat exchange of Ondol heating system was 85%. 5. The heating load per Ondol heating surface area and volume of Ondol room space were theoretically analyzed. In case of the room temperature of $20^{\circ}C$ and the ambient temperature of $-3.2~3.8^{\circ}C$, the heating load per Ondol surface area was 115.8~167.6kJ/h ㆍ㎥ and per Ondol mom space volume was 50.2~72.7kJ/h ㆍ㎥. 6. The compressor power of heat pump fur the Ondol room heating could be determined with the heating load analyzed in this study In case of the Ondol room air temperature of 17~2$0^{\circ}C$ and the ambient temperature of -5~3.8$^{\circ}C$, the compressor power of heat pump per Ondol surface area was analyzed to be $2.3\times10^{-2}psm^2$, and per volume of Ondol room space $1.0\times10^{-2}1.4\times10^{-2}ps/m^2$ps.

Performance of Solar Air Heaters (태양열공기가열기의 성능실험)

  • Cha, Jong-Hee;Song, Hi-Yul
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.5 no.2
    • /
    • pp.91-97
    • /
    • 1976
  • This study was concerned with performance of 2 types of black painted solar air heaters, one is finned type better, the other is mesh type. The performance test of heaters was made under the different operating conditions during winter season of December in Seoul area. It was analized and discussed by comparing the overall efficiency of 2 solar heaters at the same mass flow rate and ambient temperature. Experimental results show that finned type solar heater is better than mesh type from the point of view of design and heat removal efficiency. Finned-type solar air heater supplies hot air up to 30 degree centigrade above ambient temperature with an overall efficiency of 47 percent whilemesh type was 44 percent.

  • PDF

Comparison of Blue Luminescence Between Spark-processed Photoluminescian Silicon and Ambient Air Aged Anodically Etched Porous Silicon

  • Chang, Sung-Sik;Yoon, Sang-Ok
    • The Korean Journal of Ceramics
    • /
    • v.2 no.3
    • /
    • pp.137-141
    • /
    • 1996
  • Ambient air aged anodically etched porous silicon (PS) and spark-processed silicon (sp-Si) show interesting similarities and dissimilarities in some of their luminescence-related properties. Among these similarties are: (1) the photoluminescence (PL) peak maximum in the blue/violet (410 nm);(2) the blue/violet PL peak positions are essentially unchanged with temperature ; (3) PL decay times in the nanosecond region which are independent of the detection wavelength, which is much faster in decay times compared to that of observed decay time in $SiO_2$.Among the dissimilarities are: (1) the PL intensity of blue/violet luminescence, namely, the PL intensity of sp-Si is at least 2 orders of magnitude larger than that of an ambient air aged PS; (2) the blue/violet PL intensity of sp-Si is more stable than that of ambient air aged PS under UV illuminations; (3) FTIR spectra of sp-Si favor those modes, which involve silicon -oxygen bonds in $SiO_2$ stoichiometry, whereas ambient air aged PS can be considered as a nonstoichiometric oxide judging from the observed vibrational spectra.

  • PDF

Study on RDE (Real Driving Emission) Characteristic of Gasoline Vehicle Depending on the Ambient Temperature (대기 온도에 따른 가솔린 차량의 실도로 배출가스 특성 연구)

  • Kim, Hyun-Jin;Kim, Sung-Woo;Lee, Min-Ho;Kim, Ki-Ho;Lee, Jung-Min
    • Journal of ILASS-Korea
    • /
    • v.23 no.4
    • /
    • pp.221-226
    • /
    • 2018
  • Despite the increasingly stringent automotive emissions regulations, the impact of vehicle emissions on air pollution remains large. In addition, since the issue of emission of more exhaust gas than the exhaust gas measured in the test room when the vehicle passing the exhaust gas regulation standard is run on the actual road, many countries studied and introduced gas regulations about Real Driving Emission using Portable Emission Measurement System. At present, Korea regulations restrict the number of NOx and PN in diesel vehicles. In the case of gasoline vehicles, there is no regulation on emission gas, but there is a problem of continuing automobile exhaust gas problems and a large amount of gasoline GDI vehicle's PN emission. So research and interest are increasing due to this problem. In this study, characteristics of exhaust gas depending on changes of ambient temperature were analyzed among various factors affecting exhaust gas measurement of gasoline vehicles. As a result, at the low temperature test, the lower the ambient temperature, the more the exhaust gas was emitted. At ordinary temperature test, no specific tendency was observed due to changes of ambient temperature.

CFD ANALYSIS OF DISTRIBUTION OF AIR TEMPERATURE ON PLATFORMS OF A LARGE RAILWAY STATION IN SUMMER SEASON

  • Tsukamoto Kenji;Iino Akinaru;Tominaga Yoshihide
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.173-177
    • /
    • 2005
  • The purpose of this study is to analyze the principal causes of increases in air temperature on platforms of railway station. We analyzed the distribution of air temperature on Shinkansen platforms at Station 'A' using Computational Fluid Dynamics (CFD). We focused on the factors that influence the temperature dynamics associated with heat generated by trains and station buildings and their effect on the ambient temperature on platforms. In the case of heat generated by trains, air temperature on Shinkansen platforms increased by 4 to 7 degrees compared to when trains generated no heat. When a 50-m high station building was located on the windward side of the platforms, air temperature on Platform X was 2 degrees higher than when the station buildings were absent. Air? temperature on platforms VII to IX increased progressively, and the maximum air temperature on platform VIII was 3 K higher than if station buildings were absent.

  • PDF

Optimum Design of Middle-Sized CO2 Water Heater (중형 이산화탄소 급탕기의 최적 설계)

  • Park, Hanvit;Yun, Rin;Kim, Young Deug
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.4
    • /
    • pp.173-179
    • /
    • 2013
  • Middle-sized $CO_2$ water heater having compressor power of 7.45 kW was designed, and its performances were experimentally tested. Besides, optimum design of the $CO_2$ water heater was conducted by cycle simulation. When ambient temperature of $7^{\circ}C$ and hot water outlet temperature of $80^{\circ}C$ the $CO_2$ water heater showed the COP of 3.2. As hot water temperature increased the COP is getting decreased due to significant increase of compressor power consumption compared to increasing rate of heating capacity. When ambient temperature increased from $-3^{\circ}C$ to $12^{\circ}C$ the COP increased by 30%. The optimum components design of a gas cooler, an internal heat exchanger, and an evaporator were conducted, and the experimental correlation between amount of EEV opening and ambient temperature, and hot water temperature was suggested.

Effects of Ambient Conditions on the Atomization of Direct Injection Injector (분위기 조건이 직접분사식 인젝터의 미립화에 미치는 영향)

  • Lee, J.S.
    • Journal of ILASS-Korea
    • /
    • v.6 no.1
    • /
    • pp.25-34
    • /
    • 2001
  • Several efforts to meet the exhaust gas regulation have been undertaken by many researchers in recent years. Main researches are on development of design techniques of intake port and combustion chamber, atomisation of fuel and precise control of air-fuel ratio, post-treatment of exhaust gas and so on. Engine technology is changed from PFI to GDI to correspond with exhaust gas regulation. GDI technique makes it possible to preserve lean air-fuel ratio and control accurate air-fuel ratio. Nevertheless, It is not cleared that information of spray characteristics and atomization process are very dependent on fluctuation of pressure and change of temperature in intake stroke. In this study, a constant volume combustion chamber is manufactured to investigate various fluctuations of in-cylinder pressure for injection duration. It is taken photographs of injection process of conventional GDI injector using PMAS. Then, it was verified experimently that ambient conditions as temperature and pressure of combustion chamber have effects on process of spray growth and atomization of fuel.

  • PDF