• 제목/요약/키워드: ambient air pressure

검색결과 164건 처리시간 0.025초

연료전지 자동차용 흡기 소음기의 설계 변수 최적화에 관한 연구 (Optimization of the multi-chamber perforated muffler for the air processing unit of the fuel cell electric vehicle)

  • 김의열;김민수;이상권;서상훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.342-350
    • /
    • 2009
  • Fuel cells convert a fuel together with oxygen in a highly efficient electrochemical reaction to electricity and water. Since the electrochemical reaction in the fuel cell stack dose not generate any noise, Fuel cell systems are expected to operated much quieter than combustion engines. However, the tonal noise and the broad band noise caused by a centrifugal compressor and an electric motor cause which is required to feed the ambient air to the cathode of the fuel cell stack with high pressure. In this study, the multi-camber perforated muffler is used to reduce noise. We propose optimized muffler model using an axiomatic design method that optimizes the parameters of perforated muffler while keeping the volume of muffler minimized.

  • PDF

예혼합 희박 연소기의 연소특성에 관한 연구 (Study on the Combustion Characteristics of a Lean-Premixed Combustor)

  • 김한석;임암호;안국영;이상민
    • 한국연소학회지
    • /
    • 제9권1호
    • /
    • pp.25-31
    • /
    • 2004
  • Various types of the air/fuel pre-mixer have been designed and tested to investigate the combustion characteristics of the lean-premixed gas turbine combustor, such as NO emission and flame stability. One type of the pre-mixers has been selected and installed to a 70 kW lean-premixed gas turbine combustor. The concentrations of CO and NO were measured with varying equivalence ratios in the combustion chamber at ambient pressure. The result shows that the emissions of CO and NO are heavily affected by the shape of the pre-mixer. The NO and CO emissions decreased, as the mixing ratio of air and fuel increased. In addition, the NO emission of the lean-premixed low NOx combustor is more dependent on the equivalence ratio than that of the conventional combustor.

  • PDF

An Experimental Study of Water Vapor Pressure Change by Ambient Temperature at the Interface between Concrete and Fluid-Applied Membrane Layer

  • Ko, Jin-Soo;Kim, Byung-Yun;Park, Sung-Woo;Lee, Mun-Hwan;Lee, Sung-Bok
    • International Journal of Concrete Structures and Materials
    • /
    • 제3권1호
    • /
    • pp.15-23
    • /
    • 2009
  • Over about 30% of problems in construction is related to water-leaking, and the loss from this problem can incur as much as three times the cost of initial construction. Thus, water vapor pressure is known to be the primary cause of defective waterproofing. Accordingly, the theories on the relationship between water pressure and temperature as well as damp-proofing volume of concrete and the change in vapor pressure volume were reviewed and analyzed in this study by making test samples after spraying a dampness remover and applying waterproofing materials to the prepared test specimens. The result of measuring water vapor pressure with the surface temperature of the waterproofing (fluid-applied membrane) layer at the experimental temperature setting of about $10^{\circ}C$, which is the annual average temperature of Seoul, indicated that (1) the temperature of the fluid-applied membrane elevated to about $40^{\circ}C$, and the water vapor pressure generated from the fluid-applied membrane was about 0.03 N/mm 2 when the surface temperature of the waterproofing layer was raised to about $80^{\circ}C$. (2) when the temperature of the fluid-applied membrane of the waterproofing layer was raised from $30^{\circ}C$ to $35^{\circ}C$, water vapor pressure of about 0.01 N/mm 2 was generated, and (3) when a thermal source was applied to the fluid-applied membrane (waterproofing) layer, the temperature increased from $35^{\circ}C$ to $40^{\circ}C$, and approximately $0.005\;N/mm^2$ of water vapor pressure was generated.

원자로 노심 용융물의 고압분출 및 비산 현상에 대한 수치해석적 연구 (MOLTEN CORIUM DISPERSION DURING HYPOTHETICAL HIGH-PRESSURE ACCIDENTS IN A NUCLEAR POWER PLANT)

  • 김종태;김상백;김희동;정재식
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2009년 추계학술대회논문집
    • /
    • pp.121-128
    • /
    • 2009
  • During a hypothetical high-pressure accident in a nuclear power plant (NPP), molten corium can be ejected through a breach of a reactor pressure vessel (RPV) and dispersed by a following jet of a high-pressure steam in the RPV. The dispersed corium is fragmented into smaller droplets in a reactor cavity of the NPP by the steam jet and released into other compartments of the NPP by a overpressure in the cavity. The fragments of the corium transfer thermal energy to the ambient air in the containment or interact chemically with steam and generate hydrogen which may be burnt in the containment. The thermal loads from the ejected molten corium on the containment which is called direct containment heating (DCH) can threaten the integrity of the containment. DCH in a NPP containment is related to many physical phenomena such as multi-phase hydrodynamics, thermodynamics and chemical process. In the evaluation of the DCH load, the melt dispersion rates depending on the RPV pressure are the most important parameter. Mostly, DCH was evaluated by using lumped-analysis codes with some correlations obtained from experiments for the dispersion rates. In this study, MC3D code was used to evaluate the dispersion rates in the APR1400 NPP during the high-pressure accidents. MC3D is a two-phase analysis code based on Eulerian four-fields for melt jet, melt droplets, gas and water. The dispersion rates of the corium melt depending on the RPV pressure were obtained from the MC3D analyses and the values specific to the APR1400 cavity geometry were compared to a currently available correlation.

  • PDF

Temporal distribution, influencing factors and pollution sources of urban ambient air quality in Nanchong, China

  • Zhou, Hong;Li, Youping;Liu, Huifang;Fan, Zhongyu;Xia, Jie;Chen, Shanli;Zheng, Yuxiang;Chen, Xiaocui
    • Environmental Engineering Research
    • /
    • 제20권3호
    • /
    • pp.260-267
    • /
    • 2015
  • The $PM_{10}$, $SO_2$ and $NO_2$ mass concentrations were obtained over five years from monitoring stations across Nanchong, a southwest city in China. Changes in urban air quality over time, as well as the factors influencing that change, were evaluated based on air pollutant concentrations, the Air Pollution Index (API), and the Comprehensive Pollution Index (P). The results showed that the total annual mean $PM_{10}$, $SO_2$ and $NO_2$ concentrations over the five years studied were $61.1{\pm}1.1$, $45.0{\pm}3.9$ and $34.9{\pm}4.9{\mu}g{\cdot}m^{-3}$, respectively. The annual mean concentrations displayed a generally decreasing trend; lower than the annual mean second-level air quality limit. Meanwhile, the annual mean API values were in a small range of 52-53, the air quality levels were grade II, and P values were 1.06-1.21 less than the slight level ($P{\leq}1.31$). Total monthly mean $PM_{10}$, $SO_2$, $NO_2$ concentrations, and API and P values were consistently higher in winter and spring than during autumn and summer. The results of a correlation analysis showed that temperature and pressure were the major meteorological factors influencing pollution levels. Pollution sources included industrial coal and straw burning, automobiles exhaust and road dust, fireworks, and dust storms.

기체-액체 밀도차에 대한 슬로싱 충격압력의 실험적 고찰 (Study on the Effect of Density Ratio of Gas and Liquid in Sloshing Experiment)

  • 안양준;김상엽;김경환;이상우;김용환
    • 대한조선학회논문집
    • /
    • 제50권2호
    • /
    • pp.120-128
    • /
    • 2013
  • This paper presents the results of sloshing experiments having different fluids in model tanks with various density ratios. The experimental model consisting water and air at ambient, which has been commonly used, is not consistent in density ratio with that of an actual LNG cargo tank. Therefore, an advanced experimental scheme is developed to consider the same density ratio of LNG and NG by using a mixed gas of sulfur hexafluoride ($SF_6$) and nitrogen ($N_2$). For experimental observation, a two-dimensional model tank of 1/40 scale and a three-dimensional model tank of 1/50 scale have been manufactured and tested at various conditions. Two different fillings with various excitation frequencies under regular motions have been considered for the two-dimensional model tank, and three different filling levels under irregular motions have been imposed for the three-dimensional model tank. The density ratio between gas and liquid varies from the ratio of the ambient air and water to that of the actual LNG cargo container, and the different composition of gas is used for this variation. Based on the present experimental results, it is found that the decrease of sloshing pressure is predicted when the density ratio increases.

납 취급 근로자의 Monte-Carlo simulation을 이용한 노출 및 건강위해성평가 (Exposure and Health Risk Assessment of Lead Workers using Monte-Carlo Simulation)

  • 염정호;권근상;이주형;정주원
    • 한국산업보건학회지
    • /
    • 제16권2호
    • /
    • pp.110-122
    • /
    • 2006
  • Objective : This study was conducted to quantify chronic lead exposure from various media(ie. working environment, food, ambient air), and to certify the usefulness of exposure assessment using Monte-Carlo simulation in the fields of occupational health. Methods : Data were obtained from Korean Industrial Health Association, Korea Food and Drug Administration, and the Ministry of Environment. Then lead worker's exposure was estimated indirectly from various media and parameters (ie. volume inhaled, body weight, dietary intake, etc.). Uncertainty was analyzed by Monte Carlo simulation with Crystal Ball software. Exposure doses and hazard indices were simulated with various hypothetical scenarios including weekly working hours and respiratory protective equipment. Results : Without respiratory protective equipment, the total exposure dose per kilogram of body weight of lead workers was estimated as $5.45{\times}10^{-3}mg/kg/day$, and hazard index was estimated as 2.26, and exposure contributions were calculated as follows : working environment(82.42 %); foods(17.57 %); and ambient air(0.01 %). But, if working condition has changed - reduction of working hours and using respiratory protective equipment, the total exposure dose per kilogram of body weight was estimated between $1.34{\times}10^{-3}-1.49{\times}10^{-3}mg/kg/day$, and hazard index was estimated between 0.56 - 0.62. Conclusions : This study suggested that occurrence of hazardous impact(ie. increased blood pressure) through lifetime lead exposure would be expected, and that the Monte-Carlo simulation was useful for the fields of occupational health.

소형 가스터빈 연소기 고공환경 점화 시험 설비 구축 및 검증 실험 (Construction of a High-Altitude Ignition Test Facility for a Small Gas-turbine Combustor)

  • 김태완;이양석;김기우;김보연;고영성;김선진;김형모;정용운
    • 한국추진공학회지
    • /
    • 제14권3호
    • /
    • pp.61-68
    • /
    • 2010
  • 본 연구에서는 가스터빈 연소기의 고공환경 모사 점화 성능 시험을 목적으로 소형 고공환경 모사 시험 설비를 구축하였고 이에 대한 성능 실험을 수행하였다. 고공환경 조건인 저압 환경 구현을 위해서는 초음속 디퓨저를 사용하였고, 저온 환경 구현을 위해서는 드라이아이스를 냉각제로 사용한 열교환기를 사용하였다. 저압 환경 구현 성능 실험 결과 연소기로 20g/s의 공기 공급 상태에서도 연소기 내부에 고도 약 6,100m에 해당하는 저압 환경 구현이 가능한 것을 확인하였다. 또한 저온 환경 구현 성능 실험 결과 연소실 내부에 고도 6,100m 이상의 저온 환경 구현이 가능한 것을 알 수 있었으며, 상온공기와 냉각공기의 혼합율 조절로 다양한 고도의 저온 환경 구현이 가능한 것을 확인하였다.

지역 대기질 측정망에 나타난 국내 대기오염도의 최근 동향 -2002년 고농도 사례 및 그 기상 특징 (On the Recent Air Pollution Levels Observed in the Regional Air Monitoring Network -High Air Pollution Concentration Episodes and Their Meteorological Characteristics in 2002)

  • 김철희;박일수;이석조;김정수;진형아;성한규
    • 한국대기환경학회지
    • /
    • 제20권2호
    • /
    • pp.215-224
    • /
    • 2004
  • We report the high concentration episodes for PM$_{10}$, SO$_2$, NO$_2$, and $O_3$ in many urban areas Korea during 2002. The high concentration episodes are identified based on the National Ambient Air Quality Standards and the observations obtained from the Regional Air Monitoring Network composed of approximately 160 air pollution monitoring stations located in a number of major or big cities in South Korea including Seoul, Pusan, Daegu, and Incheon cities. The results show that the twenty cases of high concentration episodes in 2002 consists of both ozone warning episodes (6 cases) and high PM$_{10}$ concentration cases (14 cases), and one half of the latter are found to occur in association with the Yellow Sand (Asian Dust) phenomena. The most outstanding characteristics of the reported episodes are the excessively high levels of maximum PM$_{10}$ concentrations during the Yellow Sand period (i.e., exceeding 3,000$\mu\textrm{g}$/㎥ in April, 2002) and their variable occurrence frequencies across seasons. The high ozone concentration episode days are mainly resulting from both the high photochemical reactions and poor ventilations. The high PM$_{10}$ concentration days during non Yellow Sand periods, however, mostly occurred under the influence of synoptic meteorological conditions such as stagnant or slowly passing high pressure centers, and consequently prevailing weak wind speeds over the Korean peninsula. The overall results of our study thus suggest the importance of both synoptic and local meteorological factors for high concentration levels in the major and/or big cities in Korea.n Korea.

BLDC 모터 내 열.유동 해석 (Numerical investigation of thermo-flow characteristics in BLDC motor)

  • 김민수;이관수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2540-2545
    • /
    • 2007
  • A computational study of BLDC motor is presented to elucidate thermo-flow characteristics in winding and bearing with heat generation. Rotation of rotor and blades drives influx of ambient air into the rotor inlet and the inflow rates are predicted more at the front-side inlet than at the rear-side, which can be ascribed to the different pressure distribution. Recirculation zone appears in the tiny interfaces between windings, however, showing the enhanced cooling performance due to the higher velocity distribution near the rotor wall. In contrast, flow separation and incline angle of bearing groove, and relatively slower velocity distribution cause poor cooling performance and therefore the redesign of the bearing groove is significantly required.

  • PDF