An in vitro study was performed in order to evaluate the restoring methods in the endodontically treated molar teeth. 68 extracted teeth were divided into 4 groups according to the restoring techniques. The teeth of first group were restored by amalgam. Those of second group were restored by the stainless steel post and amalgam. The teeth of the third group were restored by the amalgam with crown. The teeth of the fourth group were restored by the stainless steel post and amalgam core with crown. All the specimens were tested and measured for the fracture load by means of the Instron (UTM-111-500 Toyo Baldwin Co., LTD. Japan) and the Pressure Instrument (Yonsei University, Department of Metal Engineering.) The results were as follows; 1. There were no statistical differences in the fracture loads between the amalgam restoration and post-amalgam core restorative techniques. 2. The techniques of amalgam core with crown showed lower fracture loads those of post and amalgam core with crown. 3. In the crowned teeth, they presented higher fracture loads than those without crown.
The purpose of this study was to observe the tensile and bonding strength of the joined amalgam restoration. Amalgam alloys of fine-cut (F-type), spherical (S-type), and dispersed type (D-type) were selected in this study, and all specimens were divided into three groups according to the condensation methods as follows. Group I : the control group which condense the same kinds of mixed amalgam into the whole part of the mold respectively. Group II : the group which condense a mix of amalgam into one half of the mold, and then condense a new mix of amalgam into the rest half of the mold 15 minutes later. Group III : the group which condense a mixed amalgam into one half of the mold, and then condense a new mix of amalgam into the rest half of the mold 7 days later. All specimens were stored in incubator at $37{\pm}1^{\circ}C$ for seven days with immersing in saline solution before testing. The tensile and bonding strength of them were measured with Instron Universal Testing machine. The results were as follows: 1. In Group I, the order of tensile strength was F-type, S-type, and D-type. 2. In case of bonding of S-type + S-type, the difference of the bonding strength between Group II and III was not significant. (P> 0.05) 3. The bonding strength of F-type + S-type of Group II was marked the highest in value, and the lowest bonding strength was showed in bonded D-type + D-type of Group III. 4. In case of bonding with the different kinds of amalgam alloy in Group II, the specimen bonded to F-type was marked the highest bonding strength, and the specimen bonded with F-type was marked the lowest one. In Group II, the bonding strength of the specimens bonded with the same kinds of amalgam alloy was presented as the same order as that of Group I. 5. In Group III, the specimen connected with D-type marked the lowest bonding strength of all specimens. In Group III, the bonding strength of the specimens connected with the same kinds of amalgam alloy was the order of S-type + S-type, F-type + F-type, and D-type + D-type.
In identifying bodies that are severely decayed or damaged, methods using fingerprints and various biochemical tests are known to have its limits. To overcome this, forensic odontological method which is based on the analysis of the cranium, tooth and dental restoration is used to enhance the accuracey of individual identification. For this reason, I have come to analysis of the dental materials that exists between the teeth that is perceived to have been previously restored and the one adjacent to it. By analyzing the constituents of gold crown-restored, non-precious metal-restored, gold inlay-restored and amalgam -restored teeth, and adjacent teeth using EDX(energy dispersive X-ray microanalysis) which was invented to analyze very small amount of elements, the nature of the restoration could be predicted and the results obtained were as follows. 1. Some of constitute of gold alloy was extracted from residual cement of gold crown restoration, but that was not extracted from the restored tooth and the one adjacent to it. 2. Some of constituents of non-precious metal alloy was extracted both in the residual cement on the tooth with no-precious metal restoration and in the tooth with the restoration itself. However, none of its constituents were found in the tooth adjacent to it. 3. Some of constituents of gold alloy were found in the residual cement of gold inlay, but they were not found in the restored tooth and the adjacent tooth. 4. Some of constituents of amalgam alloy were found both in tooth restored with amalgam and in the adjacent tooth. From the results obtained above, it is possible to utilize the data obtained from analyizing residual dental materials in a more effective way. This data compensates for the lost data due to any harm done to the restorations prior to individual identification and further enhances the accuracy. Therefore, it could be concluded that this process of analyzing residual dental materials could be beneficial to individual identification in the area of forensic odontoldogy.
The purpose of this study was to evaluate the effectiveness of copal varnish and five bonding agents(Scotchbond Multi-Purpose Plus Dental Adhesive System, Panavia 21, All Bond 2, Superbond D-Liner II plus, Fuji Duet) in reducing microleakage under amalgam restorations. Class V cavity were prepared on both buccal and lingual surface of sixty extracted human molars with cementum margin and were filled with different kinds of liners and amalgam. All teeth were stored at $37^{\circ}C$ in physiologic saline solution. After 1 week they were thermally stressed for 500 cycles between 5 and $55^{\circ}C$ in baths containing 0.5 % basic fuchsin dye. The dye penetrations were observed with a stereomicroscope. Scanning electron micrographs were taken of representative tooth sections from each group to assess the nature of the tooth/liner/amalgam interface. The statistical test were applied to the results using a one way analysis variance (ANOVA) and Duncan's multiple range test. The results were as follows ; 1. In all groups, the enamel margin showed significantly lower leakage value than the cementum margin (p<0.05). 2. At the dentin and enamel margins, the leakage value of Copalite-lined group showed significantly higher than that of no liner group (p<0.05), but showed significantly lower than that of bonding agent lined-groups (p<0.05). 3. There was no significant difference between the bonding agent lined-groups (p>0.05). 4. On the backscattered scanning electron microscopy observation, discontinuous gaps were observed between amalgam and dentin in the bonding agent-lined amalgam restorations and the bonding agents appeared to fill the gap space and were mixed with amalgam particles. At the amalgam/tooth interface, unsealed dentin and continuous gaps were found in both unlined and Copalite-lined restorations.
Su-Bin Park;Eun-Kyong Kim;Joon Sakong;Eun Young Park
Journal of Yeungnam Medical Science
/
제40권4호
/
pp.373-380
/
2023
Background: The association between dental amalgam fillings and urine mercury concentrations was investigated in this study to assess the health risks associated with dental amalgams. Methods: This cross-sectional study included 99 women in their 20s who visited the dental clinic in Daegu, Korea. The 99 participants were composed of 68 subjects who had dental amalgam fillings (exposure group) and 31 subjects who did not have dental amalgam fillings (nonexposure group). Oral examinations were conducted by a single dental hygienist, sociodemographic features were investigated as confounding variables, and urine mercury concentrations were measured using an automatic mercury analyzer. Results: The mean±standard deviation of the urine mercury concentrations of the exposure and nonexposure groups were 1.50±1.78 ㎍/g creatinine and 0.53±0.63 ㎍/g creatinine, respectively. The exposure group showed significantly higher levels than the nonexposure group (p<0.01). The urine mercury concentration significantly increased with an increase in the number of teeth filled with amalgam, cavity surfaces involved, and number of defective amalgam fillings, and according to the latest exposure time (p<0.001). In the multiple regression analysis of amalgam-related factors and urine mercury concentrations after correction for confounding factors, the urine mercury concentration in the group with six or more amalgam-filled teeth, 11 or more cavity surfaces, and two or more defective amalgams was significantly higher than that in the nonexposure group (p<0.001). Conclusion: According to this study, exposure to dental amalgams was confirmed to significantly affect urine mercury concentrations.
In this study, we tried to evaluate the effect of Amalgambond liner application on the degree of marginal leakage and retention of amalgam restoration by comparing with that of the Copalite and All-bond 2. The results obtained from this experiment were as follows; 1. Tensile strength representing the bond between amalgam and tooth structure was the highest in Amalgambond, and All-Bond 2, Copalite in descending order. There were statistically significant difference between each group(P<0.05). 2. The degree of microleakage in Amalgambond was lower than that of All-Bond 2, and Copalite, but no stastically significant difference could be found (P>0.05). 3. The liner such as Amalgambond or All-Bond 2 were evaluated to be superior to the conventional Copalite in bond strength as well as in microleakage. But the result of this study could not show the superiority of one material over the others; Amalgambond and All-bond 2. Besides the results of the study, other factors, such as practical convenience, should be considered in determining the selection of material. The support of welldesigned clinical studies on this subject are in demand.
When the exposure surface of restoration is brushed with various toothpaste in the mouth, wear or undesirable surface deposit of restoration can occur. Surface change of gallium alloys according to brushing and toothpaste may directly affect oral hygiene. The aim of this study was to evaluate the surface alterations of Gallium alloys during tooth brushing with different prophylactic agents. Two gallium-alloys and an amalgam as a control were investigated. Without and with brushing were applied with three kinds of prophylactic agents on the sample for 0, 1, 5, 10, 60 and 360 minutes. At each time interval, surface roughness was recorded by a profilometer and some pictures were taken by a SEM. All results were analyzed by the one-way ANOVA, followed by Tukey multiple comparisons and the simple linear regression analysis. The results indicate that gallium alloys are more susceptible to surface degradation during tooth brushing than amalgam with respect to the specific prophylactic agent used.
상, 하악 구치의 협면은 아말감으로 수복되어 있는 경우가 많으며, 접착 술식과 재료의 발달로 아말감에 교정용 브라켓의 직접 접착 술식이 가능하게 되었다. 그러나 아말감은 치아 협면의 일부분만을 차지하는 경우가 많아 주변의 법랑질에서도 접착력을 얻을 수 있으므로, 임상적으로 통상의 교정용 레진을 사용하여 직접 접착 술식을 시행하고 있다. 그러나 아말감 충전물이 있는 치면에 대한 교정용 레진의 직접 접착 술식의 접착강도에 대한 연구가 없는 실정으로 이에 본 실험을 시행하였다. 상, 하악 소구치를 포매하여 지름 1.5mm, 2.0mm, 2.5mm, 3.0mm의 아말감 충전물을 형성한 후 sandblasting 시행군과 비시행군으로 나누었다. no-mix type의 교정용 레진인 Ortho-one을 사용하여 브라켓을 접착한 후 전단결합강도를 측정하고 접착 파절 형태를 관찰하여 다음과 같은 결과를 얻었다. 1. 아말감 크기에 따른 비교 시 아말감 크기 1.5mm군의 전단 강도가 다른 군들에 비해 유의성 있게 높았고, 2.0mm, 2.5mm, 3.0mm군간에는 전단 강도의 차이가 없었다. (p<0.05) 2. Sandblasting 시행여부에 따른 전단결합강도의 차이는 없었다. (p<0.05) 3. 각 군간의 비교시 아말감 충전물의 면적이 브라켓 기저부 면적의 약 $61\%$를 차지하는 G군, H군의 전단결합강도는 대조군의 $50-60\%$ 수준으로 급격히 감소하였다. (p<0.05) 4. 브라켓 접착 파절 형태의 관찰 시 sandblasting을 시행하지 않은 군에 비해 sandblasting시행군의 mARI score가 유의성 있게 높았다. (p<0.05) 이상의 실험결과는 아말감 충전물의 크기가 브라켓 기저부 면적의 약 $50\%$이하일 때 sandblasting시행여부에 관계없이 통상적인 교정용 레진을 사용하여 직접 접착 술식을 시행하여도 임상적으로 적절한 전단강도를 얻을 수 있음을 시사하였다.
Composite resin and glass-ionomer cement can be used for the purpose of repair of defective amalgam restoration. The purpose of this study was to evaluate of shear bond strength of esthetic restorative materials to dental amalgam. The materials used in this study were Photo Clearfil Bright(light curing composite resin), Clearfil F II(chemical curing composite resin), Fuji II LC(light curing glass-ionomer cement), Fuji II (chemical curing glass-ionomer cement), All-Bond 2(intermediary), and Scotchbond Multi-Purpose (intermediary). A total of 120 acrylic cylinders with amalgam were divided into 8 groups After amalgam condensation, all specimens were stored for 48 hours in water at $37^{\circ}C$ and tested with Instron universal testing machine between amalgam and composite resins and glass-ionomer cements. The data were analyzes statiscally by ANOVA and Duncan test. The following results obtained ; 1. The shear bond strength of bonded composite resin to amalgam was higher than bonded glass-ionomer cement(P<.001). 2. The group 4 had highest shear bond strength with 15.45kgf/$cm^2$ and the group 5 had lowest shear bond strenght with 3.26kgf/$cm^2$(P<.001). 3. In the group 3, 4, 5, 6, the group 3, 4 with All-Bond 2 had higher shear bond strength than the group 5, 6 with Scotch bond MP both in light-curing and in chemical curing. 4. Both in composite resin and glass-ionomer cement, chemical curing materials had higher shear bond stength than light curing materials(P<.001).
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.