• 제목/요약/키워드: alternative membrane

검색결과 287건 처리시간 0.023초

Removal of safranin from aqueous solution through liquid emulsion membrane

  • Lohiya, Roshni;Goyal, Arihant;Dohare, Rajeev Kumar;Agarwal, Madhu;Upadhyaya, Sushant
    • Membrane and Water Treatment
    • /
    • 제10권5호
    • /
    • pp.373-379
    • /
    • 2019
  • One of the real issues of the recent years is water contamination because of harmful synthetic dyes. Liquid Membranes (LM) resemble a promising alternative to the current separation processes, demonstrating various points of interest as far as effectiveness, selectivity, and operational expenses. The improvement of various Liquid Membranes designs has been a matter of examination by few researchers, particularly for the expulsion of dyes from aqueous solutions. The choice of organic surfactants plays an essential role in the efficiency of the dye removal. In LM design, the most significant step towards productivity is the decision of the surfactant type and its concentration. Liquid emulsion membrane (LEM) was used to remove safranin from aqueous solutions in which the emulsion was made with the help of D2EHPA as carrier, kerosene was used as a diluent and Span 80 (Sorbiton monooleate) was used as an emulsifying agent or surfactant. Various sorts of internal stages were utilized, to be specific sulphuric acid and sodium hydroxide. The impact of parameters influencing extraction efficiency such as pH of feed solution, concentrations of surfactant and emulsifying agent in membrane phase, volume ratio of internal phase to membrane phase, internal phase concentration, agitation speed and time of extraction were analyzed.

유입흐름 변경 및 전응집 기반 이단응집 제어 적용 MBR을 통한 총인처리 개선 연구 (Enhanced total phosphorus removal using a novel membrane bioreactor by sequentially alternating the inflow and by applying a two-stage coagulation control based on pre-coagulation)

  • 차재환;신경숙;박승국;신정훈;김병군
    • 상하수도학회지
    • /
    • 제31권1호
    • /
    • pp.103-114
    • /
    • 2017
  • A membrane bioreactor by sequentially alternating the inflow and by applying a two-stage coagulation control based on pre-coagulation was evaluated in terms of phosphorus removal efficiency and cost-savings. The MBR consisted of two identical alternative reaction tanks, followed by aerobic, anoxic and membrane tanks, where the wastewater and the internal return sludge alternatively flowed into each alternative reaction tank at every 2 hours. In the batch-operated alternative reaction tank, the initial concentration of nitrate rapidly decreased from 2.3 to 0.4 mg/L for only 20 minutes after stopping the inflow, followed by substantial release of phosphorus up to 4 mg/L under anaerobic condition. Jar test showed that the minimum alum doses to reduce the initial $PO_4$-P below 0.2 mg/L were 2 and 9 mol-Al/mol-P in the wastewater and the activated sludge from the membrane tank, respectively. It implies that a pre-coagulation in influent is more cost-efficient for phosphorus removal than the coagulation in the bioreactor. On the result of NUR test, there were little difference in terms of denitrification rate and contents of readily biodegradable COD between raw wastewater and pre-coagulated wastewater. When adding alum into the aerobic tank, alum doses above 26 mg/L as $Al_2O_3$ caused inhibitory effects on ammonia oxidation. Using the two-stage coagulation control based on pre-coagulation, the P concentration in the MBR effluent was kept below 0.2 mg/L with the alum of 2.7 mg/L as $Al_2O_3$, which was much lower than 5.1~7.4 mg/L as $Al_2O_3$ required for typical wastewater treatment plants. During the long-term operation of MBR, there was no change of the TMP increase rate before and after alum addition.

비수분산 특수 제형 화장품에 대한 방부력 시험 비교 연구 (Comparison of Preservative Efficacy Tests for Water Non-dispersible Cosmetic Formulations)

  • 김용현;박성하;박병준;신계호;강학희
    • 대한화장품학회지
    • /
    • 제47권1호
    • /
    • pp.9-21
    • /
    • 2021
  • 본 연구에서는 수분산 제형에 사용되는 방부력 시험법과 PCPC (personal care products council) 가이드라인 대체시험법, direct contact membrane method 및 surface mold test 사이의 차이점을 연구하여 비수분산 특수 제형 방부력 시험 진행 시 고려되어야 하는 사항에 대해 알아보고자 한다. 우리는 스틱 및 프레스트 파우더에에 대한 시험법 비교 시 대체 시험법을 사용했을 때 개선된 수준으로 방부력 시험 결과를 확인할 수 있었다. 하지만 W/S 에멀젼과 루즈 파우더의 경우, 기존 시험법이나 대체 시험법간 결과 개선 차이가 크지 않았음을 확인하였다. 각각의 제품에 대해 방부시스템 존재 시와 부재 시 결과들을 확인했을 때, 시험법별로 차이가 발생함을 알 수 있었다. 결과적으로, 비수분산 특수 제형에 대한 방부력을 측정할 때 기존 및 대체 시험법을 병행 사용하여 개선된 수준의 결과를 얻을 수 있었다. 또한 본 연구를 통해 스틱 및 프레스 파우더의 경우, 소비자 사용방식을 적용하는 방식의 방부력 시험법을 적용하였을 때, 보다 더 유효성 있는 결과를 도출해 낼 수 있었다.

특허 및 논문 게재 분석을 통한 연료전지용 전해질막의 연구동향 (Current Patents and Papers Research Trend of Fuel Cell Membrane)

  • 우창화
    • 멤브레인
    • /
    • 제26권6호
    • /
    • pp.407-420
    • /
    • 2016
  • 연료전지는 친환경적 에너지 발생원으로 미래의 에너지 부족 문제와 공해 문제를 한꺼번에 해결하기 위한 방법으로 최근 그 연구가 활발히 진행되고 있다. 연료전지는 별도의 발전 장치를 필요로 하지 않고, 수소와 산소의 반응에 의해 전기를 직접 생산하기 때문에 발전 효율이 높다. 연료전지 시스템에서의 핵심 기술은 고분자 분리막을 제조하는 것으로써 상용화된 나피온 전해질막은 제조 단가가 높고 고온에서 성능이 급감한다는 단점이 있다. 따라서 많은 학자들이 나피온 전해질 분리막을 대체하기 위한 연구가 활발히 진행되고 있다. 본 총설에서는 연료전지용 전해질 분리막의 특허 및 논문의 기술 경쟁력 평가를 통하여 국가별, 기관별, 기업별 발표 빈도수를 정리하였으며, 고분자 전해질 연료전지, 직접 메탄올 연료전지, 그리고 알칼리 연료전지에 대한 평가를 진행하였다.

PVdF 나노섬유와 Graphene Oxide 하이브리드막에 관한 연구 (Study on the PVdF Nanofibers and Graphene Oxide Hybrid Membrane)

  • 정혜민;진유동;양우석;변홍식
    • 멤브레인
    • /
    • 제23권3호
    • /
    • pp.204-210
    • /
    • 2013
  • 본 연구는 microfiltration (MF) 적용을 위한 PVdF/GO 하이브리드 나노섬유막(FG) 제조에 관한 것이다. 지지체인 PVdF (polyvinylidene difluoride) 나노섬유막은 N,N-Dimethylacetamide (DMAc)와 아세톤에 PVdF를 녹여 방사용액 제조 후 전기방사법을 이용하여 제조하였다. 본 연구에서 사용된 GO (grapheme oxide) sheets는 Hummer's 방법에 따라 제조되었으며, PVdF 나노섬유 지지체 위에 에탄올에 분산시킨 GO용액을 분사함으로써, 최종적으로 PVdF/GO 하이브리드 나노섬유막(FG)을 제조하였다. FG막은 SEM, Raman, 접촉각, 기공특성분석장치(Porometer), 만능인장시험기(UTM)를 사용하여 조사하였고, 수투과도 분석은 제작된 셀(Dead-End Cell)을 이용하여 측정하였다. 접촉각 측정 결과로부터 제조된 FG막의 표면이 친수성으로 개질되었음을 확인할 수 있었으며, 수투과도값은 PVdF막에 비해 약 2.5배 향상된 것을 확인할 수 있었다.

Membrane fouling control in low pressure membranes: A review on pretreatment techniques for fouling abatement

  • Arhin, Samuel Gyebi;Banadda, Noble;Komakech, Allan John;Kabenge, Isa;Wanyama, Joshua
    • Environmental Engineering Research
    • /
    • 제21권2호
    • /
    • pp.109-120
    • /
    • 2016
  • Conventional treatment techniques cannot meet the stringent modern water quality regulations emanating from the need to provide high quality drinking water. Therefore, a number of studies have suggested low pressure membrane filtration as a worthwhile alternative. However, a major constraint to the extensive use of this technology in low and middle income countries is the high operating and maintenance costs caused by the inherent predisposition to membrane fouling. Notwithstanding, pretreatment of feed water using techniques such as coagulation, adsorption, oxidation and bio-filtration is believed to control fouling. In this review paper, the existing scientific knowledge on membrane fouling and pretreatment techniques for controlling fouling in low pressure membranes is analyzed with the aim of providing new and valuable insights into such techniques, as well as unveiling crucial issues noteworthy for further studies. Among the techniques reviewed, coagulation was observed to be the most cost-effective and will remain the most dominant in the coming years. Although oxidants and magnetic ion exchange resins can also control fouling, the propensity of oxidants to form health treating precursors and the high economic implications of magnetic ion exchange resins will hinder their adoption in developing countries.

Evaluation of effects of textile wastewater on the quality of cotton fabric dye

  • Kaykioglu, Gul;Ata, Reyhan;Tore, Gunay Yildiz;Agirgan, Ahmet Ozgur
    • Membrane and Water Treatment
    • /
    • 제8권1호
    • /
    • pp.1-18
    • /
    • 2017
  • In this study, reuse of biologically treated wastewater of denim washing and dyeing industry has been evaluated by membrane technologies. After that experiments were carried out at laboratory scale in textile dyeing unit by using obtained permeate water samples on 100% cotton based raw fabric belonging to examined industry. During membrane experiments, two different UF (UC100 and UC030) and two different NF (NP010 and NP030) were evaluated under alternative membrane pressures. In permeate water obtained on selected samples, conductivity at the range of $1860-2205{\mu}S/cm$, hardness at the range of 60 to 80 mg/L, total color at the range of 2.4 to 7.6 m-1 and COD at the range of 25-32 mg/L was determined. The following analyzes were performed for the dyed fabrics: perspiration fastness, rub fastness, wash fastness, color fastness to water, color fastness to artificial light, color measurement through the fabric. According to analysis results, selected permeate water have no negative impact on dyeing quality. The study showed that membrane filtration gave good performance for biologically treated textile wastewater, and NF treatment with UF pre-treatment was suitable option for reuse of the effluents.

Choline chloride-Glycerol (1:2 mol) as draw solution in forward osmosis for dewatering purpose

  • Dutta, Supritam;Dave, Pragnesh;Nath, Kaushik
    • Membrane and Water Treatment
    • /
    • 제13권2호
    • /
    • pp.63-72
    • /
    • 2022
  • Choline chloride-glycerol (1:2 mol), a natural deep eutectic solvent (NADES) is examined as a draw solution in forward osmosis (FO) for dewatering application. The NADES is easy to prepare, low in toxicity and environmentally benign. A polyamide thin film composite membrane was used. Characterization of the membrane confirmed porous membrane structure with good hydrophilicity and a low structural parameter (722 ㎛) suitable for FO application. A dilute solution of 20% (v/v) NADES was enough to generate moderate water flux (14.98 L m-2h-1) with relatively low reverse solute flux (0.125 g m-2h-1) with deionized water feed. Application in dewatering industrial wastewater feed showed reasonably good water flux (11.9 L m-2h-1) which could be maintained by controlling the external concentration polarization and fouling/scaling mitigation via simple periodic deionized water wash. In another application, clarified sugarcane juice could be successfully concentrated. Recovery of the draw solute was accomplished easily by chilling utilizing thermo responsive phase transition property of NADES. This study established that low concentration NADES can be a viable alternative as a draw solute for dewatering of wastewater and other heat sensitive applications along with a simple recovery process.

관형 PTFE 분리막을 이용한 막 접촉기(Membrane Contactor) 시스템에서 암모니아의 제거 특성 (Ammonia Removal Characteristics in Membrane Contactor System Using Tubular PTFE Membrane)

  • 안용태;황유훈;신항식
    • 대한환경공학회지
    • /
    • 제33권5호
    • /
    • pp.353-358
    • /
    • 2011
  • 본 연구에서는 막 접촉기에서 운전조건에 따른 암모니아 제거 특성에 대해 알아보았다. 물질 전달 계수를 이용하여 각 조건에서의 암모니아 제거효율을 정량적으로 비교하였다. PTFE 재질의 막을 이용한 본 시스템에서 빠른 시간 내에 효율적으로 암모니아 탈기가 가능하였다. 여러 가지 운전조건 항목 중에서 접촉시간과 용액의 pH가 전체 제거 효율에 가장 큰 영향을 미치는 것으로 나타났다. 다른 가압 방식의 막 분리 공정과는 다르게 본 공정에서는 유입수의 고형물질에 의해 효율이 감소하는 현상은 발견되지 않았다. 또한, 삼투 증류(osmotic distillation)에 의해 물질 전달 효율이 감소하는 현상은 흡수용액의 온도를 증가시키는 것으로 해결할 수 있었다. 본 연구에 사용한 막 접촉기 시스템은 유입수와 흡수용액(stripping solution)의 유속, 유입수의 pH 등을 최적화 할 경우에 고농도 암모니아 제거에 효과적으로 사용할 수 있을 것이라 예상된다.

전기응집-MBR 공정의 전류밀도와 접촉시간이 막 오염에 미치는 영향과 막 오염 저감 속도론적 고찰 (Effect of current density and contact time on membrane fouling in electrocoagulation-MBR and their kinetic studies on fouling reduction rate)

  • 엄세은;장인성
    • 상하수도학회지
    • /
    • 제31권4호
    • /
    • pp.321-328
    • /
    • 2017
  • Recently EC-MBR (Elctrocoagulation - Membrane Bio Reactor) has been suggested as one of alternative processes to overcome membrane fouling problems. Most important operational parameters in the EC-MBR are known to current density and contact time. Their effect on membrane filtration performances has been reported well, however, quantitative interrelationship between both parameters not been investigated yet. The purpose of this study is to give a kinetic model suggesting the current density and the contact time required to reduce the membrane fouling. The 4 different set of current densities (2.5, 6, 12 and $24A/m^2$) and contact times (0, 2, 6 and 12 hr) were selected as operational parameters. After each electro-coagulation under the 16 different conditions, a series of membrane filtration was carried out. The membrane fouling decreased as the current density and contact time increased, Total fouling resistances under different conditions, $R_t(=R_c+R_f)$ were calculated and compared to those of the controls ($R_0$), which were calculated from the data of experiments without electro-coagulation. A kinetic approach for the fouling reduction rate ($R_t/R_0$) was carried out and the equation ${\rho}^{0.46}_it=7.0$ was obtained, which means that the product of current density and the contact time needed to reduce the fouling in certain amounts (in this study, 10% of fouling reduction) is always constant.