• Title/Summary/Keyword: alternating discharge

Search Result 59, Processing Time 0.029 seconds

A study on the fabrication and characteristics of plasma Polymerized hexamethyldisiloxane thin films (플라즈마중합 헥사메틸디실록산 박막의 제조 및 특성에 관한 연구)

  • Lee, S.H.;Lee, B.S.;Park, S.H.;Lee, N.H.;Kim, J.S.;Woo, H.W.;Lee, D.C.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1540-1542
    • /
    • 1997
  • Plasma polymerized thin films were fabricated by interelectrode capacitively coupled type apparatus. FT-IR analyses indicated that the thin film spectra are composed not only of the corresponding monomer bands but also of several new bands. Relative dielectric constant and dielectric loss tangent of thin films fabricated in the discharge power of 90[W] showed $3.212{\sim}3.805$ and $0.0026{\sim}0.0451$ in alternating frequency of $10^3{\sim}10^6$[Hz]. Contact angle measurement indicated that cross-link of the films is increased with the discharge power.

  • PDF

A Study on the Charging and Diagnosis System of xEV Reusable Waste Battery

  • Park, Sung-Jun;Kim, Chun-Sung;Park, Seong-Mi
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.6_1
    • /
    • pp.669-681
    • /
    • 2021
  • As the supply of xEV in Korea is rapidly increasing, the amount of waste batteries is expected to increase rapidly, but the current recycling system for waste xEV batteries is very insufficient. In order to properly utilize the xEV reusable battery module, it is essential to classify it into a type that has similar discharge characteristics to the current state of health(SOH), which is the discharge capacity of the battery. This paper proposes a system that can minimize the exchange of energy with the KEPCO system by using the charging/discharging method by circulating power between batteries in order to minimize the power consumption when charging and discharging waste batteries. In the proposed system, a function to measure parameters during the charging/discharging test of the waste battery was implemented to build a customized big date for the test waste battery. In addition, the dynamic characteristics of the proposed circuit were analyzed using PSIM, which is useful for power electronics analysis, and the validity of the proposed circuit was verified through experiments.

Electron Temperature, Plasma Density and Luminous Efficiency in accordance with Discharge Time in coplanar AC PDPs

  • Jeong, S.H.;Moon, M.W.;Oh, P.Y.;Jeong, J.M.;Ko, B.D.;Park, W.B.;Lee, J.H.;Lim, J.E.;Lee, H.J.;Han, Y.G.;Son, C.G.;Lee, S.B.;Yoo, N.L.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1203-1206
    • /
    • 2005
  • Electron temperature and plasma density in coplanar alternating-current plasma display panels (AC-PDP's) have been experimentally investigated in accordance with discharge time by a micro-probe in this experiment. The resolution of a step mortor to move in micro-Langmuir probe is 10um.[1-3] The used gas in this experiment is He-Ne-Xe (4%) mixure gas. And sustain voltage is 320V which is above of firing voltage for degradation. The electron temperature and plasma density can be obtained from current-voltage (I-V) characteristics of micro Langmuir probe, in which negative to positive bias voltage was applied to the probe. And Efficiency is calculated by formula related discharge power and light emission. Those experiments operated as various discharge time ($0{\sim}72$ Hours). As a result of this experiment, Electron Temperature was increased from 2eV to 5eV after discharge running time of 20 hours and saturates beyond 20 hours. The plasma density is inversely proportional to the square root of electron temperature. So the plasma density was decreased from $1.8{\times}10^{12}cm^{-3}$ to $8{\times}10^{11}cm^{-3}$ at above discharge running time. And the Efficiency was reduced to 70% at 60hours of discharge running time.

  • PDF

Daily Variation of Size-Fractionated Chlorophyll a Concentrations and Water Conditions Associated with Freshwater Discharge during Summer in the Yeongsan River Estuary (영산강 하구의 하계 담수 방류와 연관된 크기별 Chlorophyll a와 수환경의 일간 변동)

  • Kim, Sehee;Shin, Yongsik
    • Journal of Marine Life Science
    • /
    • v.5 no.2
    • /
    • pp.72-80
    • /
    • 2020
  • A sea dike in the Yeongsan River estuary was constructed in 1981 to supply water and reclaim tidal flats for agriculture, separating the estuary into the freshwater and seawater zones. However, the sluice gates are frequently opened and freshwater is discharged in summer when more rainfall is recorded than other seasons, then converting the estuary to brackish water system. In this study, the direct effect of freshwater discharge was investigated by monitoring daily variation in water properties and phytoplankton size structure before and after the freshwater discharge events from 2013 to 2015. Freshwater discharge resulted in a sharp decrease in salinity and dissolved oxygen (DO) at surface water whereas it increased the turbidity of water column. However, salinity did not decrease sharply in 2014 when freshwater was discharged one day before the monitoring and salinity remained low prior to the monitoring. Levels of nutrients especially dissolved inorganic nitrogen (DIN) increased after the discharge and this contributed to potential limitation of nutrients such as P or Si rather than N in the estuary. Freshwater discharge also caused the changes in phytoplankton biomass (chlorophyll a) and size structure although their responses were different between years. The changes may affect growth of grazers and thus structure of marine food web by alternating food availability in the Yeongsan River estuary.

A Study on Site Application Techniques for Insulation Reliability of Rotating Machine (고압회전기 절연열화진단의 현장적용기술연구)

  • Kim, K.Y.;Jo, K.H.;Kim, T.S.;Han, S.O.;Lee, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.286-291
    • /
    • 1991
  • Most of the failures of rotating machine are stator coil insulation failures. The insulation diagnostic testing for high voltage motors and generators are only megger test and P. I Test which is applied DC voltage until now. But it was impossible to judge insulation deterioration status of high voltage rotating machinery by above testing. In other words, even though the megger measurement values are fairly high, they used to be failed from time to time. Therefore in order to excute reliable and detailed diagnosis of insulation deterioration for rotating machinery, the tangent delta test, the alternating current test and the partial discharge test shall be applied to the insulation diagnostic testing on site.

  • PDF

Measurement of Electron Temperature and Plasma Density in Coplanar AC Plasma Display Panels.

  • Cho, Il-Ryong;Moon, Min-Yook;Ryu, Chung-Gon;Choi, Myung-Chul;Choi, Eun-Ha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.748-751
    • /
    • 2003
  • The electron temperature and plasma density in coplanar alternating-current plasma display panels (AC-PDPs) have been experimentally investigated by a micro Langmuir probe and the high speed discharge images in this experiment.

  • PDF

A New Technology of Hardening Porous Materials of Titan Powders

  • Belyavin, K.E.;Minko, D.V.;Reshetnikov, N.V.
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.1012-1013
    • /
    • 2006
  • A technology of hardening porous materials of titan powders has been elaborated. The technology is based on passing alternating current with duration of ${\sim}10^{-1}{\ldots}10^1$ s through porous ($35{\ldots}40%$) blanks made by method of Sintering by Electric Discharge (SED) by passing a pulse of current with duration of ${\sim}10^{-5}{\ldots}10^{-3}$ s. The influence of technological regimes of porous blanks treatment on their structure and properties is investigated. Geometry and dimension of contact necks between powder particles of obtained samples are evaluated. Variations of porosity and strengths as well as microstructure of porous samples materials before and after treatment are investigated. Optimum range of treatment technological regimes is determined within which porosity of $30{\ldots}35%$ with maximum strength values.

  • PDF

Performance Analysis of an Orbiter Air Compressor (오비터 공기 압축기 성능해석)

  • Kim, Hyun-Jin;Cho, Kwang-Myoung;Ko, Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.8
    • /
    • pp.754-763
    • /
    • 2005
  • This paper introduces a new concept compressor in which piston orbits in the cylinder having an annular space formed between two concentric circular walls. In this configuration, two gas pockets are formed with $180^{\circ}$ phase difference: one between the wrap of the orbiting piston and the inner cylinder wall and the other between the piston wrap and the outer cylinder wall. This alternating feature of gas compression and discharge processes yields several advantages such as low torque variation and low gas pulsation. Computer simulation program has been developed to evaluate the compressor performance. The volumetric, adiabatic, and mechanical efficiencies of the orbiter compressor are calculated to be $85.6\%,\;97.2\%,\;and\;95.2\%$, respectively, when it is used as an air compressor.

A study on the Second-Harmonic Generation(SBG) Conversion Characteristics of Nd:YAG Laser adopted Differential Superposition Mesh (중첩회로를 적용한 펄스형 Nd:YAG 레이저의 2차 SHG 변환효율에 관한 특성연구)

  • 김휘영;박두열
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.215-218
    • /
    • 2001
  • A pulsed Nd:YAG laser is used widely for materials processing and medical instrument. It's very important to control the laser energy density in those fields using a pulsed Nd:YAG laser. A pulse repetition rate and a pulse width are regarded as the most dominant factors to control the energy density of laser beam. In this paper, the alternating charge and discharge system was designed to adjust a pulse repetition rate. This system is controlled by microprocessor and allows to frequence an expensive condenser for high frequency to cheap one for low frequency. In addtion, The microcontroller monitors the flow of cooling water, short circuit, and miss firing and so on. We designed Nd:YAG laser firmware with smart microcontroller, and want to explain general matters about the firmware from now.

  • PDF

High Performance and Low Cost Single Switch Current-fed Energy Recovery Circuits for AC Plasma Display Panels

  • Han Sang-Kyoo;Youn Myung-Joong
    • Journal of Power Electronics
    • /
    • v.6 no.3
    • /
    • pp.253-263
    • /
    • 2006
  • A high performance and low cost single switch current fed energy recovery circuit (ERC) for an alternating current (AC) plasma display panel (PDP) is proposed. Since it is composed of only one power switch compared with the conventional circuit consisting of four power switches and two large energy recovery capacitors, the ERC features a simpler structure and lower cost. Furthermore, since all power switches can be switched under soft switching operating conditions, the proposed circuit has desirable merits such as increased reliability and low switching loss. Specifically, there are no serious voltage notches across the PDP with the aid of gas discharge current compensation, which can greatly reduce the current stress of all inverter switches, and provide those switches with the turn on timing margin. To confirm the validity of proposed circuit, its operation and performance were verified on a prototype for 7-inch test PDP.