• Title/Summary/Keyword: alternating

Search Result 1,354, Processing Time 0.035 seconds

Alternating Pressure Profile Characteristics of Powered Pressure Ulcer Preventing Devices (동력형 욕창예방제품의 교대부양 압력 프로파 특성)

  • Won, Byeong-Hee;Song, Chang-Seop
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.4
    • /
    • pp.639-646
    • /
    • 2010
  • The APAM's quantitative effectiveness and comparative study in preventing and treating pressure ulcer has not been sufficiently evaluated mainly because of uncertainty of pressure load input and lack of interpretation of dynamic perfusion recovery characteristics of soft tissue. The purpose of this paper was to quantify and analyze the alternating pressure characteristics of APAM as a preventive measure for pressure ulcers. To quantify the alternating load to human body, we introduced alternating pressure profile concept and developed parametric model of the profile. Regarding pressure level and cycle time, 3 global and 7 local periodic parameters were used to define the profile such as light, standard, typical and heavy duty profile shape. Pressure impulse ratio of light duty is the lowest but pressure fluctuation is significantly high. For the same duty shape, contact conditions are changed with alternating cycle time and more dramatically in shorter alternating cycle time conditions. We can conclude that if we use shorter alternating cycle time on APAM's operation we can get more positive effects regarding to inflated contact time condition. We proposed the quantitative methods on tissue viability study of external loading by simultaneous measurement of interface pressure and tissue perfusion with proper alternating pressure profile conditions.

Analysis on the alternating torque characteristics of capacitor motor with windings not in quadrature (비대칭축콘덴서 전동기의 진동토오크 특성의 해석)

  • 오경열
    • 전기의세계
    • /
    • v.26 no.4
    • /
    • pp.41-53
    • /
    • 1977
  • With the equivalent series circuit analyzed aby revolving field theory and drawn by using the equivalent circuit constant ratios in capacitor motor with windings not in quadrature having space harmonics in its magnetic field (the above ratios are the equivalent circuit constants for the fundamental flux to the magnetizing reactance of the circuit), the equation for the alternating torque with twice line freequency in the motor is directly derived, and the alternating torque is measured with the self-made stator vibration angle amplitude measuring apparatus that is composed of a pickup, filter, photoelectric pickoff etc. The measured values satisfactorily compared with computed values. The properties of the alternating torque characteristics for respective harmonic fluxes and the r5esultant alternating torque characteristic, the effects of the alternating torque characteristics for respective harmonic fluxes on the resultant alternating torque characteristic, the effects of the variation in the motor constants and the equivalent circuit constant ratios for the fundamental flux on the alternating torque characteristics for respective harmonic fluxes and the resultant alternating torque characteristic, are made clear, applying the equation. There exist the optimum values of the motor constants and the equivalent circuit constant ratios for the fundamental flux for decreasing the alternating torque, and the value could be determined in design by the method presented in this paper.

  • PDF

Solid Phase Crystallization of LPCVD Amorphous Silicon Thin Films by Alternating Magnetic Flux (교번자속인가에 의한 비정질 실리콘 박막의 결정화거동에 대한 연구)

  • 송아론;박상진;박성계;남승의;김형준
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.459-462
    • /
    • 2000
  • A new method for the fabrication of poly-Si films is reported using by alternating magnetic flux crystallization (AMFC) of LPCVD a-Si films. In this work we have studied the crystallization of LPCVD a-Si films by alternating magnetic flux. A-Si films were 1200$\AA$-thick deposited at 48$0^{\circ}C$ at a total pressure of 0.25Torr using Si$_2$H$_{6}$/H$_2$. After this step, these a-Si films were thermally annealed by Alternating Magnetic Flux at 43$0^{\circ}C$ for 1hours. The annealed films were characterized using X-ray diffraction (XRD), Raman Spectra, Atomic Force Microscopy(AFM). Both alternating magnetic flux crystallization and solid phase crystallization were investigated to compare enhanced crystallization a-Si. We have found that the low temperature crystallization method at 43$0^{\circ}C$ by alternating magnetic flux.x.

  • PDF

DUALITY OF WEIGHTED SUM FORMULAS OF ALTERNATING MULTIPLE T-VALUES

  • Xu, Ce
    • Bulletin of the Korean Mathematical Society
    • /
    • v.58 no.5
    • /
    • pp.1261-1278
    • /
    • 2021
  • Recently, a new kind of multiple zeta value of level two T(k) (which is called multiple T-value) was introduced and studied by Kaneko and Tsumura. In this paper, we define a kind of alternating version of multiple T-values, and study several duality formulas of weighted sum formulas about alternating multiple T-values by using the methods of iterated integral representations and series representations. Some special values of alternating multiple T-values can also be obtained.

Frequency Response Characteristics of Fluorescent OLED with Alternating Current Driving Method (교류구동방식에 의한 형광 OLED의 주파수 응답 특성)

  • Seo, Jung-Hyun;Ju, Sung-Hoo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.1
    • /
    • pp.40-46
    • /
    • 2019
  • To study the frequency response characteristics of alternating-current-driven organic light-emitting diodes (OLEDs), we fabricated blue-fluorescent OLEDs and analyzed their electroluminescent characteristics according to the alternating current voltage and frequency. The luminance-frequency characteristics of alternating-current-driven OLED was similar to that of a low-pass filter, and the luminance of high-voltage OLED decreased at higher frequency than low-voltage OLED. The luminance characteristics of the OLED according to the frequency is due to the capacitive reactance in the OLED, generated during the alternating current driving. The frequency response characteristics of the OLED according to the voltage is due to the decrease in internal resistance of the organic layer. In addition, the negative voltage component of the alternating current did not affect the frequency response of the OLED. Therefore, the electroluminescent characteristics of OLED with an alternating current power of 60 Hz are not influenced by the frequency.

The Effects of Alternating Set Pressure Changes on Dynamic Tissue Perfusion Characteristics (교대부양 설정압력 변화가 인체조직의 동적인 관류특성에 미치는 영향)

  • Won, Byeong-Hee;Song, Chang-Seop
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.6
    • /
    • pp.875-887
    • /
    • 2010
  • The quantitative effectiveness of powered support surfaces such as APAM in preventing and treating pressure ulcers has not been sufficiently evaluated because of uncertainty of alternating pressure load input and lack of interpretation of dynamic perfusion characteristics of soft tissue. The aim was to verify the dynamic loading effects to sacral tissue perfusion characteristics from alternating set pressure changes. We developed integrated experiment system to supply alternating load to supinely positioned sacrum and concurrently measured $TcPO_2$, $TcPCO_2$ and air cell pressure. Ten aged subjects (5 female, 5 male) were tested with alternating set pressure 20, 30, 40, 50 and 60mmHg. From the dynamic perfusion response eight characteristic parameters were proposed such as average, minimum, maximum and perfusion range regarding to $TcPO_2$ and $TcPCO_2$. A one-way ANOVA was carried out to determine whether the manipulation of alternating set pressure had any effect on $TcPO_2$ and $TcPCO_2$. From the dynamic tissue perfusion response we found mean $TcPO_2$ decreased exponentially as alternating pressure load increased and perfusion range varied mainly because of minimum level change of $TcPO_2$. And perfusion range of $TcPCO_2$ affected by increase of maximum value of $TcPCO_2$. From the results we can get more strict insights about actual physiological dynamic tissue perfusion mechanism under alternating pressure load.

Effect of Microstructure on Alternating Current-induced Damage in Cu Lines

  • Park Young-Bae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.12 no.1 s.34
    • /
    • pp.27-33
    • /
    • 2005
  • The effect of microstructure on alternating current-induced damage in 200 and 300 nm thick polycrystalline sputtered Cu lines on Si substrates has been investigated. Alternating currents were used to generate temperature cycles (with ranges from 100 to $300^{\circ}C$) and thermal strains (with ranges from 0.14 to $0.42\%$) in the Cu lines at a frequency of 10 kHz. Fatigue loading caused the development of severe surface roughness that was localized within individual grains which depends severely on grain orientations.

  • PDF

ON AUGMENTED LAGRANGIAN METHODS OF MULTIPLIERS AND ALTERNATING DIRECTION METHODS OF MULTIPLIERS FOR MATRIX OPTIMIZATION PROBLEMS

  • Gue Myung, Lee;Jae Hyoung, Lee
    • Nonlinear Functional Analysis and Applications
    • /
    • v.27 no.4
    • /
    • pp.869-879
    • /
    • 2022
  • In this paper, we consider matrix optimization problems. We investigate augmented Lagrangian methods of multipliers and alternating direction methods of multipliers for the problems. Following the proofs of Eckstein [3], and Eckstein and Yao [5], we prove convergence theorems for augmented Lagrangian methods of multipliers and alternating direction methods of multipliers for the problems.