• 제목/요약/키워드: alpha curve

검색결과 315건 처리시간 0.032초

Observation of a 2016 Ganymede stellar occultation event with the SOAO 0.6m telescope

  • Hinse, Tobias Cornelius;D'Aversa, Emiliano;Oliva, Fabrizio;Sindoni, Giuseppe
    • 천문학회보
    • /
    • 제42권2호
    • /
    • pp.83.3-84
    • /
    • 2017
  • On 2016 April $13^{th}$ the Jovian satellite Ganymede occulted a $7^{th}$ magnitude star. The predicted occultation track (occultation shadow) crossed the Northern Pacific Ocean, Japan, and South Korea. Hence, it was a very favorable event due to the star brightness in order to be accessible for small-aperture telescopes as well. While no other similar event is expected for the next 10 years, only two occultation events are reported in the literature in the past, from Earth in 1972 and from Voyager, in large disagreement in respect to the atmospheric detection. However, evidence of an exosphere around Ganymede was inferred through H Lyman alpha emission detected by Galileo UVS, through HST/GHRS detection of far-UV atomic O airglow emissions, signature of dissociated molecular oxygen. We organized a short-notice international coordinated occultation monitoring network with the aim to search for a signature of Ganymede's exosphere in the occultation light-curve by using facilities on Mauna Kea (NASA-IRTF) and Sobaeksan Optical Astronomy Observatory (SOAO) in South Korea.

  • PDF

Ti-Al금속간화합물의고온변형거동및라멜라조직의결정방위분포 (High Temperature Deformation Behavior of Ti-Al Intermetallic Compound and Orientation Distribution of Lamellae Structure)

  • 박규섭;강창용;이근진;정한식;정영관;복부양지
    • 한국정밀공학회지
    • /
    • 제21권10호
    • /
    • pp.162-169
    • /
    • 2004
  • High temperature uniaxial compression tests in the alpha single phase region were carried out on the Ti -43mo1%Al intermetallic compound, in order to obtain oriented lamellar microstructure. The compression deformation temperatures and strain rates are from 1573k to 1623k and 1.0x10$^{-4}$ s to 5.0x10$^{-3}$ s, respectively. Fully lamellar microstructure was observed after the uniaxial compression deformation in a single phase region followed by cooling to room temperature. Lamellar colony diameter depended on strain rates and test temperatures. The diameter varied between 8601m and 300fm. Stress-strain curve showed a work softening and the size of lamellar colony diameter varied depending on peak stresses. This shows the occurrence of dynamic recrystallization. Texture measurements after the uniaxial compression deformation, showed the development of fiber during dynamic recrystallization. It is seen that the area for the maximum pole density existed in 35 degrees away from the compression plane. The texture sharpens with a decrease in strain rate

필터용 AIN 압전 박막의 제작 (Preparation of AIN piezoelectric thin film for filters)

  • 금민종;김영철;서화일;김경환
    • 반도체디스플레이기술학회지
    • /
    • 제5권1호
    • /
    • pp.13-16
    • /
    • 2006
  • AIN thin films were prepared on amorphous glass and $SiO_2(1{\mu}m)/Si(100)$ substrate by the facing targets sputtering (FTS) apparatus, which can provide high density plasma, a high deposition rate at a low working gas pressure. The AIN thin films were deposited at a different nitrogen gas flow rate ($1.0{\sim}0.3$) and other sputtering parameters were fixed such as sputtering power of 200w, working pressures of 1mTorr and AIN thin film thickness of 800 nm, respectively. The thickness and crystallographic characteristics of AIN thin films as a function of $N_2$ gas flow rate $[N_2/(N_2+Ar)]$ were measured by $\alpha$-step and an X-ray diffraction (XRD) instrument. And the c-axis preferred orientations were evaluated by rocking curve. In the results, we could prepared the AIN thin film with c-axis preferred orientation of about $5^{\circ}$ on substrate temperature R.T. at nitrogen gas flow rate 0.7.

  • PDF

고압 금형 주조용 Al-4%Mg-0.9%Si 합금의 주조특성에 미치는 Fe, Mn 함량의 영향 (Effect of Fe, Mn Content on the Castability of Al-4%Mg-0.9%Si Alloys for High Pressure Die Casting)

  • 김헌주
    • 한국주조공학회지
    • /
    • 제33권2호
    • /
    • pp.55-62
    • /
    • 2013
  • Effect of Fe and Mn contents on the castability of Al-4wt%Mg-0.9wt%Si system alloy has been studied. According to the analysis of cooling curve for Al-4wt%Mg-0.9wt%Si-0.3wt%Fe-0.3/0.5wt%Mn alloy, ${\alpha}-Al_{15}(Fe,Mn)_3Si_2$ and ${\beta}-Al_5FeSi$ phases crystallized above eutectic temperature of $Mg_2Si$. Therefore, these phases affected both the fluidity and shrinkage behaviors of the alloy during solidification. As Fe and Mn contents of Al-4wt%Mg-0.9wt%Si system alloy increased from 0.1 wt% to 0.4 wt% and from 0.3 wt% to 0.5 wt% respectively, the fluidity of the alloy decreased by 26% and 33%. When Fe content of the alloy increased from 0.1 wt% to 0.4 wt%, 23% decrease of macro shrinkage and 19% increase of micro shrinkage appeared. Similarly, Mn content of the alloy increased from 0.3 wt% to 0.5 wt%, 11% decrease of macro shrinkage and 14% increase of micro shrinkage appeared. Judging from the castability of the alloy, Al-4wt%Mg-0.9wt%Si alloy with low content of Fe and Mn, 0.1 wt% Fe and 0.3 wt% Mn, is recommendable.

의학적 의사결정 지표의 고찰 및 해석에 기초한 품질통계기법의 적용 (Application of Quality Statistical Techniques Based on the Review and the Interpretation of Medical Decision Metrics)

  • 최성운
    • 대한안전경영과학회지
    • /
    • 제15권2호
    • /
    • pp.243-253
    • /
    • 2013
  • This research paper introduces the application and implementation of medical decision metrics that classifies medical decision-making into four different metrics using statistical diagnostic tools, such as confusion matrix, normal distribution, Bayesian prediction and Receiver Operating Curve(ROC). In this study, the metrics are developed based on cross-section study, cohort study and case-control study done by systematic literature review and reformulated the structure of type I error, type II error, confidence level and power of detection. The study proposed implementation strategies for 10 quality improvement activities via 14 medical decision metrics which consider specificity and sensitivity in terms of ${\alpha}$ and ${\beta}$. Examples of ROC implication are depicted in this paper with a useful guidelines to implement a continuous quality improvement, not only in a variable acceptance sampling in Quality Control(QC) but also in a supplier grading score chart in Supplier Chain Management(SCM) quality. This research paper is the first to apply and implement medical decision-making tools as quality improvement activities. These proposed models will help quality practitioners to enhance the process and product quality level.

Bioequivalence Study of Ranitidine Tablet

  • Shim, Chang-Koo;Hong, Jae-Sung;Lee, Chang-Ki;Han, Ik-Soo;Choi, Kwang-Sik
    • Archives of Pharmacal Research
    • /
    • 제13권2호
    • /
    • pp.180-186
    • /
    • 1990
  • A bioequivalence study of ranitidine tablets was conducted according to the Korean Guidine for the Bioequivalence Test using twelve healthy male subjects. The plasma concentration-timecurves of ranitidine from the test and reference tablets showed profound multiple peak phenomenon in each subject as reported earlier. However, the area under the plasma concentration-time curve (AUC) and the maximum ploasma concentration at the first peak ($C_{max1}$) of the two preparations was proven to be equal when analyzed satistically according to the criteria of the guidline;i. e., statistical power (1-$\beta$)was calculated to be over 0.8 under the condition of $\alpha$ = 5% and $\Delta$(minimum detectable difference) = 20%, and the confidence interval of the difference in AUC at 95% confidence level was in the range of $\pm$ 20%, which statisfied the criteria of bioequivalence. Equivalence of the peak concentration of ranitidine at the second peak ($C_{max2}$), and the time to reach the first ($T_{max1}$) and second verify the bioequivalence of $c_{max2}$ , $T_{max1}$ and $T_{max2}$ between the two tablets. However, we conclude that the test and reference tablets are bioequivalent taking the therapeutic characteristics of the ranitidine preparations into consideration.

  • PDF

Azomethine 기를 가지는 신소재 액정 에폭시 (LCE)와 지방족 아민의 경화반응 (Curing Reaction of Noble Liquid Crystalline Epoxy (LCE) with Azomethine/Aliphatic Amine)

  • 김상욱
    • 한국재료학회지
    • /
    • 제11권9호
    • /
    • pp.786-791
    • /
    • 2001
  • $\alpha$,$\omega$-Bis(4-glycidyloxybenzylidene-4-aminophenyl)methane (BGBAM) was synthesized from the initial materials, 4-hydroxylbenzaldehyde (HBA), 4,4'-methylenedianiline (MDA) and epichlorohydrin. The DSC trace for BGBAM shows two endotherms associated with the liquid crystalline phase transition around $104.2^{\circ}C$ and the isotropic transition around $171.2^{\circ}C$, and it also has a broad exotherm in the range of $178~300^{\circ}C$ due to the anionic homopolymerization of BGBAM. DSC curve for the curing of BGBAM with hexamethylene diamine (HMD) shows an endothermic peak around $93^{\circ}C$ attributed to the melting of BGBAM. It also has three exothermic peaks around $128.4^{\circ}C$ and $180.2^{\circ}C$ associated with the epoxide-amine reaction and weak peak in the range of $200~263^{\circ}C$ related to the anionic homopolymerization between the unreacted epoxide groups. The activation energy values of cure reaction by Kissinger method are 66.5, 67.3 and 90.6 kJ/mol for $T_{pl},\; T_{p2}\; and \;T_{p3},\; respectively$. The kinetic parameters by isoconverional method are similar value to those from Kissinger method.

  • PDF

흰쥐에서의 해당작용(解糖作用) Adrenergic Receptor에 대(對)한 검토(檢討) (The Studies on Glycogenolytic Adrenergic Receptor in Rat)

  • 박찬웅;차인준
    • 대한약리학회지
    • /
    • 제16권1호
    • /
    • pp.9-14
    • /
    • 1980
  • To evaluate the adrenergic receptors for glycogenolytic responses to catecholamine, the blood glucose level, liver glycogen content and muscle glycogen level in rats were studied with treatment of epinephrine, norepinephrine and isoproterenol. In addition, to study the possibility of interconversion of adrenergic receptors, the effects of catecholamines in feeding animal were compared with those in fasting animal. The results are summarized as follow; 1) Epinephrine and norepinephine showed dose dependent increase of blood glucose level but the effect of isproterenol was not significant. 2) The prandial states of animal did not influence on effects of catecholamines on blood glucose level. 3) Liver glycogen contents were lowered by epinephrine or by norepinephrins but effect of isoproterenol was not significant. 4) Glycogen content of skeletal muscle was significantly lowered by isoproterenol and. epinephrine shifted the dose-response curve to right, but the effect of norepinephrine was not significant. 5) The effects of epinephrine and norepinephrine on blood glucose were significantly blocked by ergotamine but not by propranolol. These results indicate that the glycogenolytic response to adrenergic agents in rat is mediated by an alpha-receptor in liver and by a beta-receptor in skeletal muscle.

  • PDF

PHOTOMETRIC PROPERTIES OF THE BRIGHT LENTICULAR GALAXY NGC 5102

  • Sohn, Young-Jong;Chun, Mun-Suk;Byun, Yong-Ik
    • 천문학회지
    • /
    • 제24권2호
    • /
    • pp.151-159
    • /
    • 1991
  • Using the photographic imagery of the SO galaxy NGC 5102, the equivalent luminosity profile and the fractional integrated luminosity curve have been derived. Several photometric parameters of the galaxy, such as a total magnitude ($B_T$), equivalent radius ($r^*_e$), effective surface brightness (${\mu}^*_e$), and concentration indices ($C_{21}$, $C_{32}$) were derived from the luminosity profiles. According to the decomposition method from the nonlinear least squares fitting, photometric parameters of the bulge (${\mu}_e$, $r_e$) and the exponential disk (${\mu}(0)$, ${\alpha}^{-1}$), and the bulge to total luminosity ratio (B/T) were obtained. The derived central disk surface brightness (${\mu} (0)\;=\;22.06\;{\pm}\;0.18\;mag/\Box"$) and the evaluated B/T ratio (= 0.52) of the NGC 5102 are close to the mean values (${\mu} (0)\;=\;21.65\;{\pm}\;0.3\;mag/\Box"$, B/T=0.63) of the SO galaxies. Analysis showed that a lens-like hump is embedded in the equivalent luminosity profile of the NGC 5102.

  • PDF

PTC Behavior of Polymer Composites Containing Ionomers upon Electron Beam Irradiation

  • Kim, Jong-Hawk;Cho, Hyun-Nam;Kim, Seong-Hun;Kim, Jun-Young
    • Macromolecular Research
    • /
    • 제12권1호
    • /
    • pp.53-62
    • /
    • 2004
  • We have prepared polymer composites of low-density polyethylene (LDPE) and ionomers (Surlyn 8940) containing polar segments and metal ions by melt blending with carbon black (CB) as a conductive filler. The resistivity and positive temperature coefficient (PTC) of the ionomer/LDPE/CB composites were investigated with respect to the CB content. The ionomer content has an effect on the resistivity and percolation threshold of the polymer composites; the percolation curve exhibits a plateau at low CB content. The PTC intensity of the crosslinked ionomer/LDPE/CB composite decreased slightly at low ionomer content, and increased significantly above a critical concentration of the ionomer. Irradiation-induced crosslinking could increase the PTC intensity and decrease the NTC effect of the polymer composites. The minimum switching current (Ι$\sub$trip/) of the polymer composites decreased with temperature; the ratio of Ι$\sub$trip/ for the ionomer/LDPE/CB composite decreased to a greater extent than that of the LDPE/CB composite. The average temperature coefficient of resistance (${\alpha}$$\sub$T/) for the polymer composites increased in the low-temperature region.