• 제목/요약/키워드: all-ceramic

검색결과 1,132건 처리시간 0.026초

지르코니아 단일구조 전부도재관의 파절강도 (FRACTURE STRENGTH OF ZIRCONIA MONOLITHIC CROWNS)

  • 정희찬
    • 대한치과보철학회지
    • /
    • 제44권2호
    • /
    • pp.157-164
    • /
    • 2006
  • Purpose: The purpose of this study was to compare the fracture strength of the zirconia monolithic all-ceramic crowns according to the thickness(0.5 mm, 0.8 mm, 1.1 mm) and IPS Empress II ceramic crown of 1.5 mm thickness. Material and method: Eight crowns for each of 3 zirconia crown groups were fabricated using CAD/CAM system(Kavo, Germany) and eight Empress II crowns were made from silicone mold and wax pattern. Each crown group was finished in accordance with the specific manufacturer s instruction. All crowns were luted to the metal dies using resin cement and mounted on the testing jig in a universal testing machine. The load was directed at the center of crown with perpendicular to the long axis of each specimen until catastrophic failure occurred. Analysis of variance and Tukey multiple comparison test(p<.05) were applied to the data. Results and Conclusion: 1. The fracture strength of the zirconia monolithic all-ceramic crown was higher thickness increased(p<.05). 2 The fracture strength of 1.1 mm thickness zirconia monolithic all-ceramic crown was higher than the fracture strength of 1.5 mm thickness IPS Empress II crown(p<.05). 3. The fracture strength of 0.5 mm thickness zirconia monolithic all-ceramic crown exceeded maximum occlusal forces.

비금속 포스트 코어가 전부도재관에 미치는 광학적인 영향 (OPTICAL EFFECTS OF NONMETALLIC POST AND CORE SYSTEMS ON ALL-CERAMIC CROWNS)

  • 김성원;조인호;임주환;임헌송
    • 대한치과보철학회지
    • /
    • 제40권5호
    • /
    • pp.493-506
    • /
    • 2002
  • Recently as the esthetic concerns about dental prosthesis have been increased, the nonmetallic post and core systems have been introduced clinically to improve the color and the low optical transmittance of conventional casting metal post and core systems. The purpose of this study was to compare and analyze the optical transmittance and the shade changes of all-ceramic crowns with two nonmetallic post and core systems. The experimental groups were classified as follows : Total 27 specimens(9 samples in each group) were evaluated. Group I : Natural teeth as a control group Group II : CosmoPost and $Empress^{(R)}$ core (Ivoclar-Vivadent, Liechtenstein) Group III : $LIGHT-POST^{TM}$ and $LIGHT-CORE^{TM}$ (Bisco, U.S.A.) In all group, all-ceramic crowns were fabricated with the same shade of IPS $Empress^{(R)}$ II (Ivoclar-Vivadent, Liechtenstein) after abutment preparation, and then two kinds of spectrophotometers, UV 3101 PC (Shimadzu, Japan) and CM 503i (Minolta Co. Ltd. Japan), were used to measure the optical transmittance and the color value. The following results were obtained : 1. The optical transmittance of each group without all-ceramic crowns, was siginificantly decreased in order of Group III, I and II (p<0.05). 2. The optical transmittance of each group with all-ceramic crowns cemented, were siginificantly decreased in order of Group I, II and III (p<0.05). 3. In comparison with the shade of all-ceramic crowns, there were no significant differences between groups regardless of the cementation. 4. In comparison with the shade changes in each group after the cementation of all-ceramic crowns, there were no significant differences between groups. From the above results, it is thought that the selection among materials used in this study doesn't influence greatly the esthetic restoration, because the differences of optical transmittance were so small that those were clinically insignificant.

PVP 결합제를 이용한 수계용 세라믹테이프의 제조 (Fabrication of Water-based Ceramic Tapes Using PVP As Binder)

  • 박일석;조유정;이명현;최세영;이득용;김대준
    • 한국세라믹학회지
    • /
    • 제38권11호
    • /
    • pp.1060-1066
    • /
    • 2001
  • 세라믹 인공치관으로 응용을 위해 생체친화적이며 용매에 용해가 잘되고 연소 후 잔류물이 남지 않는 결합제인 PVP로 수계용 알루미나 테이프를 제조하였다. 알루미나 테이프의 인장강도는 결합제(b)와 가소제(p)의 비(b/b+p))에 의해, 그리고 소결체 수축과 밀도는 알루미나(a)와 유기물(o)의 비 (a/(a+o))에 의해 영향을 받았다. 소결된 가공성 알루미나 테이프에 유리를 침투시켜 강화된 세라믹 인공치관용 복합체의 강도는 소결밀도가 증가할수록 높은 값을 보였다.

  • PDF

완전 도재관의 선택 (Selection of all ceramic crown)

  • 이승규
    • 대한심미치과학회지
    • /
    • 제24권2호
    • /
    • pp.122-133
    • /
    • 2015
  • 성공적싱 완전도재관 치료를 위한 요구조건은 통상적 치료와 크게 다르지 않다. 적절한 치아삭제, 임시치아, 및 정확한 최종인상이 중요하다. 그럼에도 불구하고 차별점은 본딩에 있다. 수복물 내면과 지대치 외면에 레진시멘트를 도포하는 것 이외에도 본딩 술식은 비생활치의 포스트 코어 치료에도 적용할 수 있다. 생활치 지대치는 비생활치보다 심미와 기능 면에서 성공을 거두기가 더 쉽다. 포스트 코어 본딩 술식은 비생활치 지대치의 장기 성공에 중요한 역할을 한다. 본 논문에서 완전 도재관의 성공 전략 중에서 포스트 코어 축성 및 완전 도재관 본딩에 관하여 임상적 경험을 나누고자 한다.

전부도재수복물을 위한 유색 및 무색 지르코니아 세라믹의 굴곡강도 (Flexure Strength of Various Colored and Uncolored Zirconia Ceramics for All-Ceramic Restoration)

  • 오상천;이해형;신미란;이일권
    • 구강회복응용과학지
    • /
    • 제23권2호
    • /
    • pp.119-130
    • /
    • 2007
  • Purpose: This investigation was designed to estimate the flexure strength, density, and microstructure of the colored and uncolored zirconia oxide ceramics for fixed partial denture. Material and Methods: LAVATM All Ceramic(3M-ESPE, USA), Cercon Smart Ceramic(Dentsply, USA), and Z-match Ceramic(DentAim, Korea) were used for this study. All specimen was fabricated by ASTM C1161. After preparing $25{\times}2{\times}1.5mm$ of rectangular column and sitting rectangular column on universal test machine (UTM), external supporting point distance is 20.0 mm, internal supporting point distance is 10.0 mm. Specimen was loaded with 0.2 mm/min of cross head speed until fracture and at the time of broken of specimen, measuring loading value with PC software. Results: The results were obtained as follows: 1. Flexure strength of uncolored zirconia was higher than that of colored zirconia. 2. In uncolored zirconia, flexure strength of LAVATM Ceramic was more higher than the other ceramics, and it showed statistical difference between LAVATM Ceramic and Cercon Smart Ceramic (P<0.05). 3. In colored zirconia, flexure strength of LAVATM Ceramic was more higher than the other ceramics too, but they did not show statistical difference (p>0.05). 4. In Weibull analysis, Characterastic strength was showed highest value to uncolored LAVATM Ceramic and lowest value to Z-match ceramic, and Weibull modulus(m) of uncolored zirconia was higher than that of colored zirconia. 5. In XRD analysis, all group except Z-match showed high peak of t-ZrO2 but they did not show m-ZrO2. Colored zirconia group showed lower peak of t-ZrO2 than that of uncolored zirconia group.

지르코니아 단일구조 전부도재관과 금속도재관의 파절강도 비교 (FRACTURE STRENGTH OF ZIRCONIA MONOLITHIC CROWNS AND METAL-CERAMIC CROWNS AFTER CYCLIC LOADING AND THERMOCYCLING)

  • 이상민;정희찬;전영찬
    • 대한치과보철학회지
    • /
    • 제45권1호
    • /
    • pp.12-20
    • /
    • 2007
  • Purpose: The purpose of this study was to compare the fracture strength of the zirconia monolithic all-ceramic crowns according to the thickness (0.5mm, 0.8mm, 1.1mm) and metal-ceramic crowns (1.0mm, 1.5mm) Material and method: Twelve crowns for each of 3 zirconia crown groups were fabricated using CAD/CAM system (Kavo, Germany) and twelve crowns for each of 2 metal-ceramic crown groups were made by the conventional method. All crowns were luted to the metal dies using resin cement. Half of the specimens were exposed to thermocycling ($5-55^{\circ}C$, 1 Hz) and cyclic loading (300,000 cycles, 50N). Subsequently, all crowns were mounted on the testing jig in a universal testing machine. The load was directed at the center of crown with perpendicular to the long axis of each specimen until catastrophic failure occurred. Analysis of variance and Tukey multiple comparison test (P<.05) were used for statistical analysis of all groups, and paired t-test (P<.05) was followed for statistical comparison between each groups' fracture load before and after cyclic loading. Results: 1. The fracture strength of the zirconia monolithic crowns and the metal-ceramic crown increased as thickness increased (P<.05). 2. The cyclic loading and thermocycling significantly decreased the fracture strength of the zirconia monolithic crowns (P<.05). 3. The standard deviation of fracture strength of the zirconia monolithic crowns was very low. Conclusion: The fracture strength of the zirconia monolithic crowns for the posterior area tends to be higher with thickness increased and 0.8mm or over in thickness is recommended to have similar or over the fracture strength of metal-ceramic crowns.

CCD카메라를 이용한 수종 전부도재관의 변연적합도에 관한 연구 (A STUDY ON THE MARGINAL FIT OF ALL-CERAMIC CROWNS USING CCD CAMERA)

  • 문병화;양재호;이선형;정헌영
    • 대한치과보철학회지
    • /
    • 제36권2호
    • /
    • pp.273-292
    • /
    • 1998
  • The purpose of this study was to evaluate marginal fit of four all-ceramic crown systems 1) conventional In-Ceram, 2) copy-milled In-Ceram using Celay system, 3) IPS Empress, 4) OPC(Optimal Pressable Ceramic). All ceramic crowns were made on epoxy dies. The fabricated crowns were sandblasted, cleaned with ultrasonic cleansing, silanated, and cemented with Bistite composite resin cement. the selected marginal areas of the crowns were the labial, lingual, mesial, and distal surface. Each selected area of surface was $0.6{\times}1.6mm$ in dimension. The image of each marginal area was captured to computer files using DT-55 Frame Grabber and light microscope connected CCD camera. The marginal gaps were measured every $70{\mu}m$ using computer image analysis program. The results obtained were summarized as follows : 1. The marginal fit of four all-ceramic crowns were significantly different from each other(p<0.01), and mean marginal fit values obtained were $31.42{\pm}16.52{\mu}m$ in conventional In-Ceram, $55.45{\pm}27.90{\mu}m$ in copy-milled In-Ceram using Celay system, $44.36{\pm}24.59{\mu}m$ in IPS Empress, $47.21{\pm}20.42{\mu}m$ in OPC. 2. In the marginal fit of conventional In-Ceraw and copy-milled In-Ceram crowns using Celay system there was no significant difference between mesiodistal and buccolingual surface, but in the marginal fit of IPS Empress and OPC crowns, there was significant difference between mesiodistal and buccolingual surface(p<0.01). 3. The marginal fit of four kinds of all-ceramic crowns was clinically acceptable.

  • PDF

전부도재교의치의 코어재료에 따른 파절강도 관찰 (Observation of Fracture Strengths According to the Core Materials for All Ceramic Bridge)

  • 정인성;김치영
    • 대한치과기공학회지
    • /
    • 제32권4호
    • /
    • pp.351-356
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate the fracture strength between the core and veneering ceramic according to 2 core materials, In-Ceram Alumina and In-Ceram Zirconia, fabricated by electro ceramic layering technique. 2 different fixed partial denture cores of three units were veneered by veneering ceramic(Ceranion, Noritake) (n=10). Methods: The fracture strengths between the core and veneering ceramic were measured through the 3 point bending test. The interfaces between the core and veneering ceramic were observed with the X-ray dot mapping of EPMA. Results: The result of fracture strength was observed that IZP group, In-Ceram Zirconia core, had higher fracture strength. IPA group, In-Ceram Alumina core, had fracture strength of 359.9(${\pm}$86.2) N. IZP group, In-Ceram Zirconia core, had fracture strength of 823.2(${\pm}$243.0) N. X-ray dot mapping observation showed that a major element in the core and veneering ceramic of IPA group was alumina and silica, respectively. No binder was observed in interfaces between the core and veneering ceramic, and no ion diffusion or transition was observed between the core and veneering ceramic. However, apparent ion diffusion or transition was observed between the core and veneering ceramic of IZP group.

Optimization of Surface Treatment for Bonding S trength between Zirconia and Veneering Porcelain

  • Won, H.Y.;Kim, H.S.L.;Yun, C.H.;Son, M.K.;Cho, H.C.
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2012년도 춘계학술발표회 논문집
    • /
    • pp.332-332
    • /
    • 2012
  • All-ceramic prostheses are widely used to fulfill the high esthetic demand. However, bonding failure between zirconia and porcelain is one of the all-ceramic prostheses failures. In order to improve clinical sucess of all-ceramic prostheses, laboratory or in-office surface conditioning techniques on zirconia have been studied.

  • PDF

치과 CAD/CAM용 Nano Hybrid Ceranic 소재를 이용한 심미 치과보철물의 제작 (A Making of Aesthetic Dental restorations with Nano Hybrid Ceramic material by CAD/CAM System)

  • 최범진
    • 대한심미치과학회지
    • /
    • 제25권2호
    • /
    • pp.98-108
    • /
    • 2016
  • 전통적인 Metal-ceramic 보철 제작 방식으로부터 All-ceramic 보철에 이르기까지 최근 신소재 개발에 영향을 주는 가장 큰 요인은 심미적인 욕구일 것이다. 우리가 사용하는 각각의 치과용 수복 재료는 재료 별로 강도, 인성, 기계 가공의 효율성 및 사용에 필요한 다양한 과정을 기반으로 임상에서 다양하게 사용되고 있다. 예를 들어 Glass ceramic과 같은 단일 소재의 경우 약한 물성을 고려하여 주로 싱글 크라운과 같은 간단한 보철에 사용하고 있으며 상대적으로 높은 파괴 인성을 가진 지르코니아 재료의 경우 싱글 크라운은 물론 브릿지의 제작에도 널리 사용하고 있다. 하지만 지르코니아 재료는 제작 과정에서 긴 Sintering 시간을 필요로 하므로 Chair side에서 빠른 보철물 제작에 쉽지 않은 부분이 있으며 주로 Lab. side에서 사용하고 있다. CAD / CAM 시스템을 이용하여 보철물을 제작하는 용도로 개발 된 Hybrid ceramic 소재는 Resin Nano Hybrid Ceramic이라고도 하며, 개선 된 물성을 포함한 나노 세라믹 요소를 기반으로 하고 있다. 이러한 특징들은 심미적이며 기능적인 보철물의 제작이 용이한 과정과 결과를 보이고 있으며 동시에 향상된 내구성을 바탕으로 보철물의 제작 과정에 유리한 조건들을 가지고 있다. 새로운 Nano Hybrid Ceramic 재료는 Composite Resin과 Glass ceramic과 같은 단일 소재들이 가진 장점들을 이용하여 술자들의 요구사항을 바탕으로 오랜 연구를 통해 개발된 치과 수복 아이템이며 Nano ceramic filler가 혼합된 구조로 되어있어 치과 수복용 복합소재로서 널리 사용하고 있다. 또한 Nano Hybrid Ceramic소재는 Composite resin의 가공 과정에서 쉽게 파절되지 않는 개선된 물성과 Glass ceramic이 가진 심미성 동시에 포함하고 있는 것이 특징이다. 따라서 Chair side와 Lab. side에서 CAD/CAM 시스템을 이용하여 보철물을 제작할 때 임상적용이 쉽고 유용한 장점을 가지고 있어 추가적인 연구가 필요하다.