• 제목/요약/키워드: alkali ion

검색결과 279건 처리시간 0.034초

고로슬래그의 지오폴리머 축중합반응에 미치는 양생온도의 영향 (Effect of Curing Temperature on Geopolymeric Polycondensation of Blast Furnace Slag)

  • 전창섭;송태웅
    • 한국세라믹학회지
    • /
    • 제48권6호
    • /
    • pp.610-616
    • /
    • 2011
  • The effect of curing temperature on basic geopolymeric reactivity and hardening behaviour of blast furnace slag were investigated using the mixture of pulverized slag and several alkaline solutions of relatively high concentration. For the pastes prepared at several different temperatures between 20$^{\circ}C$ and 90$^{\circ}C$, setting time and heat of reaction were examined while mineralogical and morphological examinations were performed for the hardened paste after curing period at same temperature. The geopolymeric reaction of slag was revealed to be accelerated strongly according to the curing temperature regardless of the sort and concentration of the alkaline solution. The increase of concentration of the alkaline solution within 9M and the existence of silicic ion in the solution also promoted the reaction severely. The mineral component and their ratio of the hardened paste were revealed to be influenced by the chemical species and silicic ion contained in alkaline solution rather than by the curing temperature. The higher temperature and longer period of curing stage were effective for the sustained formation of geopolymer and succeed improvement of density and uniformity of morphology of the final hardened body.

양이온 교환된 ZSM-5 촉매상에서 톨루엔의 선택적인 반응 (Selective Disproportionation of Toluene over Various Cation-exchanged ZSM-5 Catalysts)

  • 류종신;안병준;전학제
    • 대한화학회지
    • /
    • 제27권2호
    • /
    • pp.127-132
    • /
    • 1983
  • 톨루엔의 동종간 주고 받기 반응에 대한 ZSM-5 촉매의 활성은 양이온의 종류, 이온교환을 그리고 반응온도에 좌우된다. 활성은 알카리금속, 알카리토금속, 수소, 희토류 금속 이온이 교환되는 순서로 증가하며 이온 교환도가 증가함에 따라 감소한다. 이온 교환된 ZSM-5 촉매중에서 Cs-ZSM-5만이 p-크실렌에 대해 우세한 선택성을 나타내는데 p-크실렌에 대한 선택성은 세슘이온 교환율이 증가할 수록 반응온도가 감소 할수록 증가한다. 이러한 현상은 ZSM-5의 세공 교차점에 있는 세슘이온이 부분적으로 세공을 막아주는 형상 선택성으로 해석된다.

  • PDF

A Novel Iron(III) Selective Membrane Electrode Containing a Tripodal Polycatacholamine as Sensor

  • Bera, Rati Kanta;Sahoo, Suban K;Baral, Minati;Kanungo, B.K.
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권10호
    • /
    • pp.3592-3596
    • /
    • 2011
  • A novel poly(vinylchloride)-based membrane sensor using $N^1$,$N^3$,$N^5$-tris(2-(2,3-dihydroxybenzylamino)-ethyl)cyclohexane-1,3,5-tricarboxamide (CYCOENCAT, L) as ionophore has been prepared and explored as $Fe^{3+}$ selective electrode. The membrane electrode composed of ionophore, poly(vinylchloride) and o-nitropheyloctyl ether in the optimum ratio 4:33:63 gave excellent potentiometric response characteristics, and displayed a linear log[$Fe^{3+}$] versus EMF response over a wide concentration range of $1.0{\times}10^{-5}-1.0{\times}10^{-1}$ M with super nernstian slope of 28.0 mV/decade and the detection limit of $8.0{\times}10^{-6}$ M. The proposed ion selective electrode showed fast response time (< 15 s), wide pH range (3.0-7.0), high non-aqueous tolerance (up to 20%) and adequate long life time (120 days). It also exhibited very good selectivity for $Fe^{3+}$ relative to a wide variety of alkali, alkaline earth, transition and heavy metal ions. Further, the analytical applicability of the sensor was tested as an indicator electrode in the potentiometric titration of $Fe^{3+}$ with EDTA.

Novel Thallium(I)-Selective Membrane Electrode Based on a Podal Ligand

  • Ganjali, Mohammad Reza;Pourjavid, Mohammad Reza;Mouradzadegun, Arash;Hosseini, Morteza;Mizani, Farhang
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권11호
    • /
    • pp.1585-1589
    • /
    • 2003
  • A PVC-based membrane electrode for thallium(I) ions based on 1,21,23,25-tetramethyl-2,20: 3,19-dimetheno-[H, 2] H, 23H, 25H-bis-[1,3] dioxocino[5,4-i:5',4'-i] benzo [1,2-d: 5.4-d'] bis [1,3] benzodioxocin(II) has been prepared. The electrode displays a linear dynamic range of $1.0{\times}10^{-1}-1.0{\times}10^{-5}$ M, with a Nernstian slope of $59.8{\pm}0.2\;mV\;{decad^-1}$, and a detection limit $5.0{\times}10^{-6}$ M. It has a very fast response time of<10 s and can be used for at least ten weeks without a considerable divergence in potentials. This electrode revealed comparatively good selectivity with respect to alkali, alkaline earth, and some transition and heavy metal ions and was effective in a pH range of 2.0-10.0. It was used as an indicator electrode in potentiometric titration of thallium ion with sulfide ion.

알칼리 활성화제 종류별 페로니켈슬래그를 사용한 3성분계 시멘트 경화체의 내구특성 (Durability Characteristics of Ternary Cement Matrix Using Ferronickel Slag According to the Alkali-Activators)

  • 조원정;박언상;정호섭;안기용
    • 한국건설순환자원학회논문집
    • /
    • 제8권2호
    • /
    • pp.190-197
    • /
    • 2020
  • 본 연구에서는 페로니켈의 제련과정에서 발생하는 산업부산물인 페로니켈슬래그 미분말과 광물질혼화재료를 사용한 시멘트 경화체의 역학적 특성 및 내구성능을 평가하였다. 3성분계 시멘트 경화체의 수화열, 공극구조, 압축강도, 길이변화, 급속염화물 침투시험(RCPT), 동결융해 저항성을 평가하여 보통포틀랜드 시멘트와 비교하였다. 그 결과 페로니켈 슬래그 미분말 및 광물질 혼화재료를 사용한 3성분계 시멘트 경화체의 압축강도는 기준콘크리트에 비하여 낮은 강도발현을 하였으나, 알칼리 활성화제를 사용함에 따라 어느 정도 회복되는 것을 알 수 있었다. 페로니켈 슬래그를 사용한 시멘트 모르타르의 길이변화는 기준 시편보다 수축이 덜 발생하는 것으로 나타났다. 또한 페로니켈 슬래그 미분말을 사용한 경우 알칼리활성화제 사용유무에 관계없이 모두 ASTM C 1202에서 제시한 '매우 낮은' 영역의 값을 나타내었으며, 동결융해저항성 평가에서도 기준콘크리트에 비하여 아주 우수한 결과를 나타내었다.

Comparative study of 82Sr separation/purification methods used at Brookhaven National Laboratory and ARRONAX

  • Ha, Yeong Su;Yoon, Sang-Pil;Kim, Han-Sung;Kim, Kye-Ryung
    • 대한방사성의약품학회지
    • /
    • 제5권2호
    • /
    • pp.71-78
    • /
    • 2019
  • Nuclear imaging is one of the most powerful measures for non-invasive diagnosis of myocardial vascular disease. Radionuclide such as 13N, 15O, 201Tl and 82Rb is used for the measurement of cardiac blood flow. 13N, 15O and 201Tl are produced in cyclotrons while 82Rb is obtained from generator. Rubidium (Rb), an alkali ion, behaves biologically like potassium, and accumulates in myocardial tissue. Rb has rapid blood clearance profile which allows the use of 82Rb with a short physical half-life of 75 s for non-invasive evaluation of regional myocardial perfusion. There are several advantages of 82Rb over other radioisotopes. An ultra-short half-life significantly reduces the exposure of patients to radiation and allows to repeat injections for studying the effects of medical intervention. As a positron emitter, 82Rb allows positron emission tomography (PET) imaging which have shown superior diagnostic performances. 82Rb can be produced from generator by decay of its parent 82Sr. However, the preparation of 82Sr is difficult, because appropriate purity is required to meet the specification of the product. Recently reported procedure from ARRONAX research institute showed that a Chelex-100 resin is sufficient for this purpose and additional column is not necessary. Whereas Brookhaven National Laboratory (BNL) procedure contains three ion exchange resin separation, including Chelex-100 resin. Currently, since 82Sr production site is non-existent in Korea, Korea Atomic Energy Research Institute (KAERI) has plan to produce 82Sr within specifications. We compared 82Sr purification procedures reported from ARRONAX and BNL to investigate the most suitable procedure for our conditions.

Beryllium(II) Recognition by Allosteric Effects in 1,2-Ethylenedioxybenzene Based Ditopic Receptors

  • Kim, Dong-Wan;Kim, Jung-Hwan;Hwang, Jae-Young;Choi, Myong-Yong;Kim, Jae-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권8호
    • /
    • pp.2643-2647
    • /
    • 2011
  • Efficient ditopic receptor, uranyl(II) N,N'-(ethylenedioxy)benzenebis(salicylideneimine) (3) for beryllium ion has been obtained upon functionalization of 1,2-ethylenedioxybenzene (1) with a uranyl-salphen (salphen = N,N'-phenylenebis(salicylideneimine)) unit. Binding affinities of the receptor, 3 in AN-DMSO (v/v 95:5) solution have been measured for alkali and alkaline earth metal ions by conductometry comparing 1. The results showed that both monotopic 1 and ditopic receptor 3 were selective for $Be^{2+}$ ions over other cations, while especially 3 that can complex both with cations (coordinated to basic oxygen of ethylenedioxybenzene) and anions (coordinated to the Lewis acidic uranyl center) results in an increase of the stability constants by a factor of $10^{2.42}$ with respect to 1. Furthermore, the $Be^{2+}$-3 interactions are demonstrated by $^1H$ NMR experiments in highly polar solvent medium, DMSO-$d_6$. Higher selectivities were also observed for $Be^{2+}$ when the ditopic receptor, 3 was incorporated into PVC membranes and tested as ion selective electrodes at neutral pH.

고분자막 pH 센서 제작 및 특성 (Preparation and characterization of polymeric membrane pH Sensors)

  • 조동회;정성숙;정구춘;이경호;박면용;김병수
    • 센서학회지
    • /
    • 제5권4호
    • /
    • pp.35-40
    • /
    • 1996
  • 수소이온운반체로 HDBA(hexyldibenzylamine)나 HDPA(hexyldiphenylamine)을 이용하여 고분자막 pH 센서를 제작하였고, 온도 및 막의 두께 변화에 대한 전기화학적 특성을 연구하였다. HDPA를 이용한 센서는 수소이온에 대하여 선택적으로 감응하지 않았으며, HDBA를 이용한 센서는 pH 2 - pH 10 범위에서 수소이온에 대하여 선형적이고, 응답시간도 30 - 50초로 매우 빠르며, Nernstian 기울기는 53.6mV/pH을 나타내었다. pH 센서는 유리전극과 비교하여 알칼리금속과 알칼리토 금속이온에 대하여 방해를 적게 받았고, 재현성 및 안정성에 대한 편차는 2 - 4mV(${\pm}0.1mV$)로 우수하게 나타내었다.

  • PDF

Tetramethylthiuram monosulfide를 ionophore로 이용한 납 이온 선택성 poly(aniline) 고체 접촉 전극 (Lead Ion Selective Solid Contact Electrode based on Tetramethylthiuram monosulfide ionophore)

  • 한원식;박운석;권혜영;이영훈;홍태기
    • 한국응용과학기술학회지
    • /
    • 제30권2호
    • /
    • pp.356-361
    • /
    • 2013
  • Lead (II) ion selective poly(aniline) solid contact electrode based on Tetramethylthiuram monosulfide ionophore as a sulfur containing sensing material is successfully developed. The electrode exhibits good linear response of 25.6 mV / decade (at $20{\pm}0.2^{\circ}C$, r2=0.995) within the concentration range of $1.0{\times}10^{-1}{\sim}4.0{\times}10^{-7}$ M Pb (II). The composition of this electrode was Ionophore : PVC : dioctylphthalate : potassiumtetrakis(4-chlorophenyl)borate : Oleic acid = 5.0 : 20.0 : 25.0 : 4.0 : 5.0. When we consider the results of using different composition electrodes based on only one potassiumtetrakis(4-chlorophenyl)borate or Oleic acid liphophlic additive, poly(aniline) solid contact electrode based on Tetramethylthiuram monosulfide ionophore with potassiumtetrakis(4-chlorophenyl)borate and Oleic acid liphophlic additive had the best result in response characteristics. The electrode shows good selectivity for lead (II) ion in comparison with alkali, alkaline earth, transition and heavy metal ions. This electrode is suitable for use with aqueous solutions of pH 3.0 ~ 7.0 and their standard deviation in the measured emf differences was ${\pm}2.94$ mV at Tris buffered lead sample solution of $1.0{\times}10^{-2}$ M and ${\pm}2.82$ mV at Tris buffered lead sample solution of $1.0{\times}10^{-3}$ M. Their stabilization time was less than 710 s. and response time was less than 16 s.

고전장하에서 제조된 PVA/Gelatin 블렌드막의 이온투과 특성 (Ion Permeation of PVA/Gelatin Blend Membrane Prepared Under High Electric Field)

  • 허양일;조정웅
    • 폴리머
    • /
    • 제30권6호
    • /
    • pp.568-571
    • /
    • 2006
  • Poly(vinyl alcohol) (PVA)/gelatin(GEL) 블렌드막을 고전장하에서 제조한 후, 팽윤거동 및 이온투과 특성을 연구하였다. 알칼리 금속염(LiCl, NaCl, KCl)에 대한 투과 실험 결과, 인가된 전장의 강도가 10 kV까지 증가하면 막의 곡로율이 감소하여 이온 투과도가 증가하지만, 10 kV이상이 되면 막의 결정화도의 증가 영향이 커져 투과도는 감소하였다. 완충용액에 대한 팽윤 실험에서 pH 6을 기점으로 산성영역 혹은 염기성 영역으로 갈수록 하전기간의 반발로 인하여 팽윤도가 증가함을 관찰하였다. 제조된 블렌드막의 KCl 투과도 계수는 pH 6에서 극대값을 보였고, 산성 혹은 염기성 영역으로 갈수록 급격히 감소되는 것을 확인하였다. 이러한 거동은 막내 존재하는 관능기들이 해리함에 따라 용해도 증가 영향보다는 Donnan 배제효과가 우세하게 작용하기 때문인 것으로 생각된다. 특히 온도에 따른 투과거동에서 $40^{\circ}C$를 기점으로 KCl 투과도 계수가 약 5배 정도 급격히 증가함을 보여주었다.