• Title/Summary/Keyword: airborne measurement

Search Result 158, Processing Time 0.026 seconds

A Study on the Efficient Measurement of Airborne Asbestos Concentrations at Demolition Sites of Asbestos Containing Buildings, etc. in Seoul (서울시내 석면함유 건축물 철거 현장 등에서의 효과적인 공기 중 석면농도 측정을 위한 연구)

  • Lee, Jinhyo;Lee, Suhyun;Kim, Jeongyeun;Kim, Jihui;Chung, Sooknye;Kim, Jina;Oh, Seokryul;Kim, Iksoo;Shin, Jinho;Eo, Soomi;Jung, Kweon;Lee, Jinsook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.2
    • /
    • pp.113-121
    • /
    • 2014
  • Objectives: This study is intended to seek credible and efficient measurements on airborne asbestos concentrations that allow immediate action by establishing complementary data through comparative analysis with existing PCM and KF-100 method real-time monitoring equipment in working areas in Seoul where asbestos-containing buildings are being demolished, including living environment surroundings. Materials: We measured airborne asbestos concentrations using PCM and KF-100 at research institutes, monitoring networks, subway stations and demolition sites of asbestos-containing buildings. Through this measurement data and KF-100 performance testing, we drew a conversion factor and applied it via KF-100. Finally we verified the relationship between PCM and KF-100 with statistical methods. Results: The airborne asbestos concentrations by PCM for the objects of study were less than the detection limit(7 fiber/$mm^2$) in three (20%) out of 15 samples. The highest concentration was 0.009 f/cc. The airborne asbestos concentrations by PCM in laboratories, monitoring networks, subway stations and demolition sites of asbestos-containing buildings were respectively $0.002{\pm}0.000$ f/cc, $0.004{\pm}0.001$ f/cc, $0.009{\pm}0.001$ f/cc, and $0.002{\pm}0.000$ f/cc. As a result of KF-100 performance testson rooftops, the conversion factor was 0.1958. Applying the conversion factor to KF-100 for laboratories, the airborne asbestos concentrations ratio of the two ways was nearly 1:1.5($R^2$=0.8852). Also,the airborne asbestos concentration ratio of the two ways was nearly 1:1($R^2$=0.9071) for monitoring networks, subway stations, and demolition sites of asbestos-containing buildings. As a result of independent sample t-tests, there was no distinction between airborne asbestos concentrations monitored in the two ways. Conclusions: In working areas where asbestos-containing buildings are being demolished, including living environment surroundings, quickly and accurately monitoring airborne asbestos scattered in the air around the working area is highly important. For this, we believea mutual interface of existing PCM and a real-time monitoring equipment method is possible.

A Study of Laboratory Measurement of EO GRD Resolution for Airborne EO/IR Sensor (항공용 EO/IR 센서의 EO GRD 분해능 실험실 측정 연구)

  • Huh, Joon;Kim, Chang-Woo;Kim, Sungsoo;Kim, Byoung-Wan
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.793-799
    • /
    • 2014
  • EO GRD(Ground Resolved Distance) resolution of airborne EO/IR(Electro-Optical/Infrared) sensor is a critical factor in test and evaluation for EO sensor performance. We propose the laboratory measurement set-up for EO GRD by constructing optical collimator which includes integrated sphere, blackbody, equivalent 3-bar target and 6 DOF motion simulator. GRD is measured in the photographic imagery of bar targets by 3 different distances for 3 EO/IR sensors and the measured results were analyzed statistically. We found that at least 7 sheets of imagery are needed in order to obtain meaningful EO GRD. The result of statistical analysis shows that the distribution of the measured GRD is nearly symmetric about the average GRD, and the better imagery ratio above the average GRD is about 40~70%. Also from the best GRD analysis, it is estimated that the design goal for EO GRD should be 30% superior to the required GRD.

The Need for QA/QC in the Measurements of Airborne Pollutants - Conduction of and Directions towards an Interlaboratory Comparison Test in 1998 by the Measurement and Analysis Division of KOSAE (대기오염측정에 대한 정도관리의 필요성 - 1998년도 한국대기환경학회 측정분석분과회의 실험실간 비교분석사업 시행과 전개방향)

  • 김기현;이강웅;김조천;서영화;이종해;허귀석
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.1
    • /
    • pp.63-69
    • /
    • 1999
  • To offer a general guideline for the quantitative analysis of airborne pollutants, we designed and conducted a comprehensive QA/QC test using two different strategic approaches, namely (1) field-based comparative measurement and (2) laboratory-based comparative analysis. The former task was performed to make meaningful comparison of combined errors occurring from both sampling and analytical techniques in the measurements of such components as: (1) criteria pollutants, (2) volatile organic compounds (VOCs), and (3) particulate matters with the associated metals and ions. The latter task was also conducted to compare various types of bias arising mainly from the laboratory analytical procedures of (1) gaseous standards of VOCs and (2) of aqueous standards of metals and ions. The concentration data derived from each of these two different types of major tasks were evaluated per chemical species categorized as above. While the very details of these studies are to be reported on an individual basis according to the above classification of the project, this paper is presented to provide an overview of the whole project - its aim and direction.

  • PDF

Airborne Fine Particle Measurement Data Analysis and Statistical Significance Analysis (공기중 미세입자 측정 데이터 분석 및 통계 유의차 분석)

  • Sung Jun An;Moon Suk Hwan
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.1
    • /
    • pp.1-5
    • /
    • 2023
  • Most of the production process is performed in a cleanroom in the case of facilities that produce semiconductor chips or display panels. Therefore, environmental management of cleanrooms is very important for product yield and quality control. Among them, airborne particles are a representative management item enough to be the standard for the actual cleanroom rating, and it is a part of the Fab or Facility monitoring system, and the sequential particle monitoring system is mainly used. However, this method has a problem in that measurement efficiency decreases as the length of the sampling tube increases. In addition, a statistically significant test of deterioration in efficiency has rarely been performed. Therefore, in this study, the statistically significant test between the number of particles measured by InSitu and the number of particles measured for each sampling tube ends(Remote). Through this, the efficiency degradation problem of the sequential particle monitoring system was confirmed by a statistical method.

  • PDF

Seasonal Variation of Airborne Chlorides in Coast by Sea Area and Region, South Korea (해역 및 지역에 따른 해안가 대기중 염분량의 계절적 변동)

  • Jung, Jahe;Lee, Jong-Suk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.5
    • /
    • pp.611-619
    • /
    • 2023
  • The first survey of the airborne chlorides along the nationwide coast of South Korea was conducted 18 years ago, and the area index of coastal airborne chlorides and salt attack environmental rating are being utilized in the design, construction, and maintenance of domestic structures. However, due to environmental changessuch as climate change and coastal topography changes, changes of airborne chlorides along the coast are expected to occurregionally and by sea area. Therefore, the second survey has been conducted since 2021. Inthis paper, we analyzed the seasonal variations of airborne chlorides along the coast by region and sea area for one year of the second survey. Additionally, we compared the results withthe survey results of Japan's coastal airborne chlorides, which islocated close to South Korea and has a similar climate, to increase the objectivityofthe analysis. The averageairborne chloridesin the second surveywas highest on the west coast, and the seasonal variation was also the largest on the west coast. Looking at the seasonal variations by sea area, the East Sea had highairborne chloridesinthe summer and autumn,theWestSea inthe autumnandwinter, and the SouthSea in the summer. In addition, compared to the firstsurvey, allsea areasshowed short periods ofsignificantly higher coastalsalinity and clearerseasonal variations.

POSSIBILITIES TO IMPROVE TRANSIENT GEAR SHIFT NOISE (SHIFT CLONK) IN A PASSENGER CAR

  • BIERMANN J. W.;REITZ A.
    • International Journal of Automotive Technology
    • /
    • v.6 no.1
    • /
    • pp.23-28
    • /
    • 2005
  • The presented investigation of shift clonk in a vehicle with front-wheel drive shows how a detailed analysis of the complete acoustic system with respect to excitation, transfer and radiation foremost enables possibilities of noise reduction to be worked out. One of the most important basics for the shift clonk analysis was a synchronous measurement of both, torsional vibrations in the drive train on the excitation side as well as airborne and structure-borne noise signals on the transfer and radiation side. Thus, root causes could be identified and improvement measures of the internal shift system could be worked out. An analysis of the transfer paths by means of airborne and structure borne noise measurements made evident that the side shafts were responsible for the disturbing frequencies in the transfer paths. With the help of the FE-simulation it was possible to develop measures of structure optimisation for the side shaft system. The realisation of these measures clearly reduced the shift-noises in the vehicle interior.

Determination of Airborne Formaldehyde Using the Gas Chromatograph-Pulsed Discharge Electron Capture Detector (GC-PDECD를 이용한 공기 중 포름알데하이드의 분석)

  • 김희갑;박미진;김만구
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.2
    • /
    • pp.117-123
    • /
    • 2002
  • A gas chromatographic method for the determination of airborne formaldehyde was established. In order to be highly detectable with the electron capture detector, formaldehyde was derivatized to its pentafluorobenzyl oxime form by reacting with O- (2,3,4,5,6- pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA) at pH of 4.6 and temperature of 50$^{\circ}C$ for 1 hour. Air samples were collected into a Tedlar$\^$(R)/ bag followed by transferring into water contained in two impingers in series. Collection efficiency in the front trap was higher than 90%. Measurement of selected indoor and outdoor air samples showed higher formaldehyde concentrations in indoor air environments and the importance of ventilation for reducing indoor pollution.

A Study on the Airborne Noise of the Small Fishing Boats (소형어선의 소음에 관한 연구)

  • Yang, Yong-Su;Jung, Kong-Heun;Seo, Du-Ok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.28 no.4
    • /
    • pp.412-417
    • /
    • 1992
  • In full-speed cruising, the airborne sound pressure levels are measured from 11 small fishing boats operated around Cheju Island. In these measurement, 9 measuring positions are selected in each fishing boats. The results of measurements and analyses are as follows: 1. The sound pressure levels in FRP boats are higher than those in wooden boats. 2. The highest sound pressure level is 112dB(A) at the engine room in C boat, while the lowest one is 72dB(A) at the front deck in K boat. 3. The highest sound pressure level is shown to be in the frequency band less than 500Hz. 4. The highest sound pressure level is shown to be in the frequency band less than 500Hz. 5. Through all 9 positions, the sound pressure levels are higher in B and C boat and lower in E and K boats.

  • PDF

Reduction of airborne and structure-borne noise of naval ship pump (함정용 펌프의 공기음 및 고체음저감)

  • 김현실;김재승;강현주;김봉기;김상렬
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.942-947
    • /
    • 2002
  • In this study, reduction of airborne and structure-borne noise of naval ship pump is presented. Since piping system arrangement such as valve location, flexible joint, pipe diameter and elbow location, discharge basin affect greatly on the noise measurement, care must be taken to minimize the unnecessary noise from the piping system. It is shown that structure-borne noise of the motor with single resilient mount system exceeds criterion. Therefore, it is concluded that double resilient mount system is inevitable. Two kinds of mount is studied for upper mount; spring and rubber type. Although both mounts show good performance at low frequency including rpm frequency, 63Hz, spring mount is found to be inadequate at high frequency, because spring coil acts as a path for SBN.

  • PDF

Design and Performance Evaluation using Computational Fluid Dynamics (CFD) Analysis of Wetcyclones for the Collection of Airborne Bacteria (공기 중 박테리아 포집을 위한 습식 사이클론의 CFD 해석을 이용한 설계 및 성능 평가)

  • Hyun Sik Ko;Jungwoo Park;Jiwoo Jung;Jungho Hwang
    • Particle and aerosol research
    • /
    • v.19 no.3
    • /
    • pp.77-87
    • /
    • 2023
  • We present the development of a wetcyclone sampler designed for the sampling of airborne bacteria. The wetcyclone design involves a combination of two traditional cyclone shapes and computational fluid dynamics (CFD) analysis to validate its effectiveness in terms of pressure drop and collection efficiency. The wetcyclone exhibits a collection efficiency of over 90% for bacteria, specifically targeting Staphylococcus aureus. Additionally, the wetcyclone enables continuous bioaerosol sampling using a liquid medium (deionized water), demonstrating a concentration ratio exceeding >105 and a stable microbial recovery rate of 81.9%. The application of real-time quantitative polymerase chain reaction (qPCR) and the colony counting method ensures precise measurement of the concentration ratio and microbial recovery rate.