• 제목/요약/키워드: airborne exposure

검색결과 261건 처리시간 0.031초

중소도시, 대도시 및 산업지역에서 채취한 미세분진 ($PM_{2.5}$)과 입자상 다환방향족탄화수소의 계절적인 분포 특성 (Characteristics of Seasonal Distributions of Fine Particles ($PM_{2.5}$) and Particle-Associated Polycyclic Aromatic Hydrocarbons in Urban, Metropolitan and Industrial Complex Sites)

  • 김희갑;정경미;김태식
    • Environmental Analysis Health and Toxicology
    • /
    • 제21권1호
    • /
    • pp.45-56
    • /
    • 2006
  • This study was conducted to investigate seasonal distributions of fine particles ($PM_{2.5}$) and associated polycyclic aromatic hydrocarbons (PAHs) at three cities. $PM_{2.5}$ samples were collected on glass fiber filters at urban (Chuncheon), metropolitan (Seoul), and industrial complex sites (Ulsan) from September, 2002 to February, 2004 using the Andersen FH 95 Particulate Sampler. About five 24-hour samples were collected from each site per season. The filters were analyzed for mass and six selected PAHs concentrations. $PM_{2.5}$ concentrations were the highest either in winter or spring, which could be attributed to the increase of fossil fuel combustion in winter or the transport of yellow sand to the Korean peninsula from China in spring, respectively. Regional $PM_{2.5}$ concentrations were higher in the order of Seoul>Chuncheon>Ulsan without statistical difference among cities. The filters were extracted using dichloromethane in an ultrasonicator and analyzed for six PAHs (anthracene, fluoranthene, pyrene, benzo[a]anthracene, chrysene, and benzo[a]pyrene) with HPLC. Total PAHs concentrations were statistically different among seasons in each site, and the highest concentrations were observed in winter at each sampling site. For total samples collected, the median total PAHs concentrations in Chuncheon ($4.6ng/m^3$) and Seoul ($4.4ng/m^3$) were approximately two times higher than that in Ulsan ($2.1ng/m^3$). Chrysene was a component found in the highest proportion among total PAHs at each site. Carcinogenic risks calculated based on the BaP toxic equivalency factors (TEFs) over the whole sampling period were higher in the order of Chuncheon>Seoul>Ulsan. This study suggests that the atmosphere of Chuncheon is contaminated with particulate matter and PAHs at the levels equivalent to those of Seoul and that an appropriate measure needs to be taken to mitigate human health risks from inhalation exposure to airborne fine particles.

중수로원전 방사선작업종사자의 공기중 삼중수소 섭취 후 뇨시료 제출 시간이 체내 삼중수소 농도에 미치는 영향 분석 (An Internal Tritium Concentration Analysis in Urine Samples as a Function of Submission Time after Airborne Tritium Intake at Korean Pressurized Heavy Water Reactors)

  • 김희근;공태영;정우태;김석태
    • Journal of Radiation Protection and Research
    • /
    • 제34권4호
    • /
    • pp.184-189
    • /
    • 2009
  • 중수로원전의 방사선작업종사자는 방사선작업 종료 후에 뇨시료를 제출하여 공기중 삼중수소의 섭취에 따른 내부피폭 선량을 평가하고 있다. 이 경우 종사자가 제출한 뇨시료는 삼중수소가 체내에서 평형에 도달한 대표시료(Representative sample)라는 전제를 필요로 한다. 국제방사선방호위원회(ICRP)의 간행물과 삼중수소의 인체평형에 대한 캐나다의 실험결과에 의하면 체내로 유입된 삼중수소는 약 2-3시간 후에 평형에 도달한다고 기술하고 있다. 그런데 원전에서는 계획예방정비기간 동안 일시에 많은 작업이 진행되고 빈번한 종사자의 출입으로, 방사선작업 종료 후 제출하는 뇨시료는 섭취 후 평형에 도달하는 약 2시간 경과 이전에 제출하거나, 지연하여 제출하는 경우가 발생할 수 있다. 따라서 이 논문에서는 방사선작업 종료 후 종사자가 제출하는 시간대별 뇨시료 중의 삼중수소 농도를 측정하였고, 이를 근거로 체내 삼중수소의 농도에 대한 변화추이와 선량평가에 미치는 영향을 분석하였다. 그 결과 종사자의 뇨시료는 대부분 삼중수소 섭취 후 2시간 정도에 신체 내에서 평형에 도달하는 것으로 확인되었다.

휴대용 X-Ray 형광기기(XRF)를 이용한 공기중 납농도 평가 (Evaluation of Lead levels in Airborne by a portable X-Ray Fluorescence Instrument)

  • 안규동;이종천;조광성;김남수;김진호;이성수;이병국
    • 한국산업보건학회지
    • /
    • 제11권3호
    • /
    • pp.235-240
    • /
    • 2001
  • This study was performed to compare the lead levels of 20 quality control standard samples(KOSHA:18-2000) and 72 field samples in lead-acid battery manufacturing plant between ICP and portable-XRF methods. 1. While the proficiencies of 20 quality control standard samples by ICP were 100%, those of analytic result values by XRF were 75%. 2. The correlation coefficient(r) between the reference values for quality control (REF) and the analytic result values by ICP (ICP) was 1.0(p<0.05), and simple linear regression equation and the coefficient(R2) were REF = -0.0009 + 1.016 ICP and 0.9997, respectively. 3. The correlation coefficient(r) between the analytic result values of quality control standard samples by ICP (ICP) and by XRF (XRF) was 0.975(p<0.05), and simple linear regression equation and the coefficient(R2) were ICP = -0.0003 + 1.002 XRF and 0.950, respectively. 4. The correlation coefficient(r) between the analytic result values for lead samples of a lead-acid battery manufacturing plant by ICP (ICP) and by XRF (XRF) was 0.993(p<0.05), and simple linear regression equation and the coefficient(R2) were ICP = -2.058 + 0.996 XRF and 0.987, respectively. 5. While the frequency distributions of XRF /ICP(Ratio) for each ICP concentration levels in a lead-acid battery manufacturing plant revealed high proportion in ratio range of 0.876-1.125 than in ration range of 1.126-1.375. Also, ICP concentration level in ration range of 0.786-1.125 was increased with increase of frequency distribution of XRF/ICP. 6. The limit of detection of XRF on lead was determined to be $6.11{\mu}g$/filter The data presented in this study indicated that relationship for lead level of quality control samples and field samples in a lead -acid battery manufacturing plant by ICP and portable-XRF methods was proved. The practicing industrial hygienist can use portable-XRF to produce a rapid on-site determination of lead exposure that can immediately becommunicated to workers and help identify appropriate levels of personal protection.

  • PDF

국내 석탄연소 발전소에서 취급하는 천연방사성물질의 방사능 농도 분석 (Analysis of Radioactivity Concentration in Naturally Occurring Radioactive Materials Used in Coal-Fired Plants in Korea)

  • 김용건;김시영;지승우;박일;김민준;김광표
    • 방사선산업학회지
    • /
    • 제10권4호
    • /
    • pp.173-179
    • /
    • 2016
  • Coals and coal ashes, raw materials and by-products, in coal-fired power plants contain naturally occurring radioactive materials (NORM). They may give rise to internal exposure to workers due to inhalation of airborne particulates containing radioactive materials. It is necessary to characterize radioactivity concentrations of the materials for assessment of radiation dose to the workers. The objective of the present study was to analyze radioactivity concentrations of coals and by-products at four coal-fired plants in Korea. High purity germanium detector was employed for analysis of uranium series, thorium series, and potassium 40 in the materials. Radioactivity concentrations of $^{226}Ra$, $^{228}Ra$, and $^{40}K$ were $2{\sim}53Bq\;kg^{-1}$, $3{\sim}64Bq\;kg^{-1}$, and $14{\sim}431Bq\;kg^{-1}$ respectively in coal samples. For coal ashes, the radioactivity concentrations were $77{\sim}133Bq\;kg^{-1}$, $77{\sim}105Bq\;kg^{-1}$, and $252{\sim}372Bq\;kg^{-1}$ in fly ash samples and $54{\sim}91Bq\;kg^{-1}$, $46{\sim}83Bq\;kg^{-1}$, and $205{\sim}462Bq\;kg^{-1}$ in bottom ash samples. For flue gas desulfurization (FGD) gypsum, the radioactivity concentrations were $3{\sim}5Bq\;kg^{-1}$, $2{\sim}3Bq\;kg^{-1}$, and $22{\sim}47Bq\;kg^{-1}$. Radioactivity was enhanced in coal ash compared with coal due to combustion of organic matters in the coal. Radioactivity enhancement factors for $^{226}Ra$, $^{228}Ra$, and $^{40}K$ were 2.1~11.3, 2.0~13.1, and 1.4~7.4 for fly ash and 2.0~9.2, 2.0~10.0, 1.9~7.7 for bottom ash. The database established in this study can be used as basic data for internal dose assessment of workers at coal-fired power plants. In addition, the findings can be used as a basic data for development of safety standard and guide of Natural Radiation Safety Management Act.

다중이용시설별 실내공기 오염물질 농도분포 및 기준치 이상 값의 구성비 조사 (The Distribution of Indoor Air Pollutants by the Categories of Public-Use Facilities and Their Rate of Guideline Violation)

  • 전정인;이혜원;최현진;전형진;이철민
    • 한국환경보건학회지
    • /
    • 제47권5호
    • /
    • pp.398-409
    • /
    • 2021
  • Background: The types and effects of hazardous pollutants in indoor air may vary depending on the characteristics of the sources and pollutants caused by physical and chemical properties of buildings, the influence of outdoor air, and the exposure and use characteristics of residents. Objectives: This study was conducted to provide basic data on the establish of indoor air quality management for different classes of public-use facilities by presenting the characteristics of concentration distribution of hazardous pollutants by different public-use facilities and the status of the excess proportion of exceeding standards. Methods: This study analyzed self-measurement data from public-use facilities taken from 2017 to 2019 A total of 133,525 facilities were surveyed. A total of 10 types of pollutants that have maintenance and recommended standards stipulated in the Indoor Air Quality Control Act from the Ministry of Environment were investigated. The excess proportion and the substances exceeding the criteria for each type of public-use facilities for these pollutants were investigated. Results: As a result of the analysis of the proportion of exceeding the standard for each type of public-use facility, the facilities with the highest excess proportion of the standards for each hazardous pollutant were: PM10 in railway stations (8.93%), PM2.5 in daycare centers (7.36%), CO2 in bus terminals (2.37%), HCHO in postpartum care centers (4.11%), total airborne bacteria in daycare centers (0.69%), CO in museums (0.1%), NO2 in postpartum care centers (1.15%), Rn in museums (0.78%), total volatile organic compounds in postpartum care centers (7.20%) and mold in daycare centers (1.44%). Conclusions: Although uncertainty may arise because this study is a result of self-measurement, it is considered that this study has significance for providing basic data on the establishment in the future of indoor air quality management measures customized for each type of public-use facility.

실내환경의 환경성담배연기(ETS) 중 카드뮴에 관한 연구 (Cadmium Concentrations in Environmental Tobacco Smoke of Indoor Environments)

  • 하권철;박동욱;윤충식
    • 분석과학
    • /
    • 제16권4호
    • /
    • pp.299-308
    • /
    • 2003
  • 실내 사무환경에 대해 흡연환경에 따라 흡연실, 흡연 허용 사무실, 비흡연사무실, 흡연실 인접 지역 등을 대상으로 ETS 중 발암물질인 카드뮴을 포함한 금속류, 니코틴, 3-EP, 호흡성먼지등 지표물질의 농도분포와 이의 분포에 영향을 주는 흡연밀도, 흡연지수 등을 조사하여 그 상관성을 파악하였다. 공기교환횟수는 흡연실과 흡연허용사무실에서 각각 평균 11.1, 4.6 회/시간을 나타냈으며, 흡연밀도는 최고 $2.6cig/m^2{\cdot}hr$에서부터 최저 $0.2cig/m^2{\cdot}hr$로 나타났다. 금속류 중 카드뮴은 기하정규분포를 보였으며 흡연환경별 기하평균 농도가 흡연실에서 $0.045{\mu}g/m^3$, 흡연실 인근 지역에서 $0.018{\mu}g/m^3$, 흡연허용사무실에서 $0.021{\mu}g/m^3$, 비흡연사무실에서는 $0.017{\mu}g/m^3$의 분포를 보였으며 통계적으로는 유의한 차이를 나타냈다(p<0.05). 실내 흡연 환경에 따른 카드뮴의 농도 비를 조사한 결과 비흡연실 기준으로 흡연실에서 2.6배, 흡연허용사무실에서 1.2배의 농도 분포를 보였다. 카드뮴과 지표물질간 상관성을 조사한 결과 니코틴과의 상관계수가 0.53 (p<0.001)으로 가장 높게 나타났으며 호흡성먼지와는 0.43, 3-EP와는 가장 낮은 0.41의 상관계수 값을 보였으며, 흡연 밀도와는 0.54 (P<0.001), 흡연지수와는 0.63(p<0.001)의 상관계수 값을 보였다. 이러한 연구 결과를 토대로 ETS 중 중금속류에서는 카드뮴을 지표물질로 활용할 수 있다고 판단할 수 있다.

Progress of Composite Fabrication Technologies with the Use of Machinery

  • Choi, Byung-Keun;Kim, Yun-Hae;Ha, Jin-Cheol;Lee, Jin-Woo;Park, Jun-Mu;Park, Soo-Jeong;Moon, Kyung-Man;Chung, Won-Jee;Kim, Man-Soo
    • International Journal of Ocean System Engineering
    • /
    • 제2권3호
    • /
    • pp.185-194
    • /
    • 2012
  • A Macroscopic combination of two or more distinct materials is commonly referred to as a "Composite Material", having been designed mechanically and chemically superior in function and characteristic than its individual constituent materials. Composite materials are used not only for aerospace and military, but also heavily used in boat/ship building and general composite industries which we are seeing increasingly more. Regardless of the various applications for composite materials, the industry is still limited and requires better fabrication technology and methodology in order to expand and grow. An example of this is that the majority of fabrication facilities nearby still use an antiquated wet lay-up process where fabrication still requires manual hand labor in a 3D environment impeding productivity of composite product design advancement. As an expert in the advanced composites field, I have developed fabrication skills with the use of machinery based on my past composite experience. In autumn 2011, the Korea government confirmed to fund my project. It is the development of a composite sanding machine. I began development of this semi-robotic prototype beginning in 2009. It has possibilities of replacing or augmenting the exhaustive and difficult jobs performed by human hands, such as sanding, grinding, blasting, and polishing in most often, very awkward conditions, and is also will boost productivity, improve surface quality, cut abrasive costs, eliminate vibration injuries, and protect workers from exposure to dust and airborne contamination. Ease of control and operation of the equipment in or outside of the sanding room is a key benefit to end-users. It will prove to be much more economical than normal robotics and minimize errors that commonly occur in factories. The key components and their technologies are a 360 degree rotational shoulder and a wrist that is controlled under PLC controller and joystick manual mode. Development on both of the key modules is complete and are now operational. The Korean government fund boosted my development and I expect to complete full scale development no later than 3rd quarter 2012. Even with the advantages of composite materials, there is still the need to repair or to maintain composite products with a higher level of technology. I have learned many composite repair skills on composite airframe since many composite fabrication skills including repair, requires training for non aerospace applications. The wind energy market is now requiring much larger blades in order to generate more electrical energy for wind farms. One single blade is commonly 50 meters or longer now. When a wind blade becomes damaged from external forces, on-site repair is required on the columns even under strong wind and freezing temperature conditions. In order to correctly obtain polymerization, the repair must be performed on the damaged area within a very limited time. The use of pre-impregnated glass fabric and heating silicone pad and a hot bonder acting precise heating control are surely required.

Microbe Hunting: A Curious Case of Cryptococcus

  • Bartlett, Karen H.;Kidd, Sarah;Duncan, Colleen;Chow, Yat;Bach, Paxton;Mak, Sunny;MacDougall, Laura;Fyfe, Murray
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2005년도 국제학술대회
    • /
    • pp.45-72
    • /
    • 2005
  • C. neoformans-associated cryptococcosis is primarily a disease of immunocompromised persons, has a world-wide distribution, and is often spread by pigeons in the urban environment. In contrast, C. gattii causes infection in normal hosts, has only been described in tropical and semi-tropical areas of the world, and has a unique niche in river gum Eucalyptus trees. Cryptococcosis is acquired through inhalation of the yeast propagules from the environment. C. gattii has been identified as the cause of an emerging infectious disease centered on Vancouver Island, British Columbia, Canada. No cases of C. gattii-disease were diagnosed prior to 1999; the current incidence rate is 36 cases per million population. A search was initiated in 2001 to find the ecological niche of this basidiomycetous yeast. C. gaftii was found in the environment in treed areas of Vancouver Island. The highest percentage of colonized-tree clusters were found around central Vancouver Island, with decreasing rates of colonization to the north and south. Climate, soil and vegetation cover of this area, called the Coastal Douglas fir biogeoclimatic zone, is unique to British Columbia and Canada. The concentration of airborne C. gattii was highest in the dry summer months, and lowest during late fall, winter, and early spring, months which have heavy rainfall. The study of the emerging colonization of this organism and subsequent cases of environmentally acquired disease will be informative in planning public health management of new routes of exposure to exotic agents in areas impacted by changing climate and land use patterns. Cryptococcosis is an infection associated with an encapsulated, basidiomycetous yeast Cryptococcus neoformans. The route of entry for this organism is through the lungs, with possible systemic spread via the circulatory system to the brain and meninges. There are four cryptococcal serogroups associated with disease in humans and animals, distinguished by capsular polysaccharide antigens. Cryptococcus neoformans: variety grubii (serotype A), variety neoformans (serotype D), and variety gattii (serotypes B and C) (Franzot et at. 1999). C. neoformans variety gattii has recently been elevated to species status, C. gattii. C. neoformans val. grubii and var. neoformans have a world-wide distribution, and are particularly associated with soil and weathered bird droppings. In contrast, C. gattii (CG) is not associated with bird excrement, is primarily found in tropical and subtropical climates, and has a restricted environmental niche associated with specific tree species. (Ellis & Pfiffer 1990) Ellis and Pfeiffer theorize that, as a basidiomycete, CG requires an association with a tree in order to become pathogenic to mammals. In Australia, CG has been found to be associated with five species of Eucalypts, Eucalyptus camaldulensis, E. tereticornis, E. blakelyi, E. gomphocephala, and E. rudis. Eucalypts, although originally native to Australia, now have a world-wide distribution. CG has been found associated with imported eucalypts in India, California, Brazil, and Egypt. In addition, in Brazil and Columbia, where eucalypts have been naturalized, native trees have been shown to harbour CG (Callejas et al. 1998; Montenegro et al. 2000). In British Columbia, Canada, since the beginning of 1999, there have been 120 confirmed cases of cryptococcal mycoses associated with CG in humans, including 4 fatalities (data from British Columbia Centre for Disease Control), and over 200 cases in animal pets in BC (data from Central Laboratory for Veterinarians). What is remarkable about the BC outbreak of C. gattii-cryptococcosis is that all of the cases have been residents of, or visitors to, a narrow area along the eastern coast of Vancouver Island, BC, from the tip of the island in the south (Victoria) to Courtenay on the north-central island as illustrated in Figure 1. Of the first 38 human cases, 58% were male with a mean age of 59.7 years (range 20 - 82): 36 cases (95%) were Caucasian. Ten cases (26%) presented with meningitis, the remainder presented with respiratory symptoms. Cultures recovered from cases of cryptococcosis associated with the outbreak were typed as serogroup B, which is specific to CG (Bartlett et al. 2003). This was the first reported outbreak of CVG in Canada, or indeed, the world. Where infection with CG is endemic, for example, Australia, the incidence of cryptococcosis ranges from 1.8 - 4.7 per million between the southern and northern states (Sorrell 2001). However, the overall incidence of cryptococcosis in immunocompenent individuals has been estimated at 0.2 per million population per year (Kwon-Chung et al. 1984). The population of Vancouver Island is approximately 720,000,consequently, even if the organism were endemic, one would expect a maximum of 0.15 cases of cryptococcal disease annually.

  • PDF

The Occupant Perception and Investigation of Indoor Air Quality at Home in Seoul

  • Sohn, Jong-Ryeul;Kim, Young-Whan;Byeon, Sang-Hoon
    • 환경위생공학
    • /
    • 제18권1호
    • /
    • pp.51-57
    • /
    • 2003
  • 최근 산업장 뿐만아니라 주택에서의 실내환경오염은 대단히 중요한 관심사이다. 특히 미국 EPA에서는 성인이 하루에 약 80 % 이상을 실내 공간에서 생활하고 있는 것으로 보고하고 있으며, 이러한 생환 방식의 변화에 인한 최근 도시화 지역에서의 실내 공기질(indoor air quality)의 문제가 새로운 환경 이슈로 부각되고 있고, 일본을 비롯한 구미 각 국에서도 21세기 환경문제 중 실내환경(indoor environment) 문제를 최우선으로 다루고 있다. 그러므로 본 연구에서는 주택에서의 실내공기질을 평가하기 위하여 설문지를 통하여 인식도를 조사하고 그를 토대로 6개의 다른 주거환경을 가진 주택을 대상으로 실내공기오염도를 측정하였다. 본 연구에서 평가한 측정항목은 온도, 습도, CO, $CO_2$, 호흡성분진, 포름알데히드, 총부유세균(TBC)이었으며, 주택의 지역 및 계절별로 나누어 측정하였는데, 측정결과 호흡성분진은 주택 5,6 에서 국내의 기준을 초과하였으며, 총부유세균은 흥콩과 싱가폴의 실내기준 권고치인 $500{\;}CFU/m^3$을 초과였고, HCHO는 모든 대상 주택에서 초과하였다. 또한 통계적으로 분석한 결과 주택의 건축년도와 CO, TBC가 0.01 수준에서 유의성 관계를 나타냈으며, 습도는0.05 수준에서 유의성을 나타냈다. 또한 주택의 거주자 500인을 대상으로 조사한 설문지 결과에서는 대부분 응답자가 실내공기오염에 대하여 인식하고있으며, 실내오염으로 인해 피로>두통>눈 아픔>기침 등을 호소하고 있으며, 실내공기정화장치가 필요하다고 응답하였다. 결론적으로 본 연구의 목적은 주택에서의 실내공기질을 평가하여 실내공기질의 중요성을 인식시키고, 그에 대한 구체적인 대책방안을 제시하여 관련 기준을 준비하는데 기초적인 자료를 마련하고 주민들이 쾌적한 삶을 유지하는데 기여하고자 한다.

해저 콘크리트 구조물의 신뢰성 이론에 의한 시간 의존적 내구수명 평가 (Time Dependent Evaluation of Corrosion Free Life of Concrete Tunnel Structures Based on the Reliability Theory)

  • 백승우;정민선
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권3호
    • /
    • pp.142-154
    • /
    • 2011
  • 본 연구에서는 철근 콘크리트 터널 구조물을 해상 대기중 비래염분이 침투하는 터널 내벽과 해수에 항시 접촉하는 터널 외벽으로 구분하여, 몬테카를로 시뮬레이션에 의해 철근 부식 개시 확률을 예측하였다. 염해관련 변수의 변동성을 평가하기 위하여 염소이온 확산계수, 표면 염소이온농도, 피복두께, 임계 염소이온농도를 실제 실험 및 문헌 조사를 통해 확률특성을 구하였다. 그 결과 염소이온 확산계수의 평균치는 $3.77{\times}10^{-12}m^2/s$ 이었으며, 대상 부재인 터널 내벽과 외벽의 피복두께는 각각 45.5mm, 94.7mm으로 조사되었고, 임계 염소이온농도의 평균은 결합재 단위중량당 0.69%이었다. 각 변수의 확률적 특성에 근거하여 노출기간에 따른 철근위치에서의 염소이온 농도 분포를 구하였다. 재령이 증가할수록 침투 염소이온 농도의 평균값은 증가하며, 변동계수는 감소하게 됨을 알 수 있었다. 또한 확률론적 염해 해석기법을 적용하여 콘크리트 터널 내벽과 외벽에 대해 내구수명 및 부식개시 확률을 평가하였다. 염소이온 침투의 시간의존성을 고려하지 않은 경우 터널 내벽과 외벽에 대해 각각 8년, 12년의 내구수명이 도출되었으나, 시간의존적 모델에서는 178년, 283년의 내구수명이 계산되어 구조물의 설계내구수명(100년)을 만족하고 있음을 보였다. 또한, 시간의존성을 고려하지 않은 경우 100년에서의 부식 개시 확률은 터널 내벽과 외벽에 대해 각각 59.5, 95.5%였으며, 시간의존성 모델에서는 2.9, 0.2%로 계산되었다. 따라서 구조물의 과다설계를 방지하고 보다 합리적인 내구수명 설계 및 평가를 위해서는 염소이온 확산의 시간의존성을 고려하여야 한다. 마지막으로 본 연구에서 문헌 조사를 통해 구한 부식 발생 임계 농도를 현재 콘크리트 관련 기준에 제시한 값과 비교하여 분석하였다.