Survey of Airborne Fungi Levels in 24 Seasonal Divisions and Correlation Analysis with Meteorological Elements (24절기 야외 부유곰팡이 농도 조사 및 기상요소와의 상관성 분석)

  • Kim, Myoung Nam;Hong, Jin Young;Lee, Jeong Min;Park, Ji Hee
    • Journal of Conservation Science
    • /
    • v.35 no.6
    • /
    • pp.652-663
    • /
    • 2019
  • To identify daily and annual changes in outdoor airborne fungi, it is necessary to shorten the collection cycle and increase the number of measurements. In this study, measurements were performed by employing an air sampler and potato dextrose agar media on the rooftop of National Research Institute of Cultural Heritage during a period of one year (August 2018 to July 2019). The collection cycle spanned the twenty-four seasonal divisions and the collection time was 2 p.m. and 11 p.m.. Meteorological elements were collected at intervals of one hour. Furthermore, the concentration of airborne fungi was monitored and correlation analysis with meteorological elements was subsequently conducted. Obtained results indicate that the concentration of airborne fungi is found to be highest in November, autumn, night, followed by autumn, summer, winter, and spring. The concentration, type, and dominant species of airborne fungi can vary depending on factors such as rainfall, typhoons, and yellow dust (fine dust). The concentration of airborne fungi indicates a strong positive linear relationship between precipitation, number of precipitation days, and relative humidity. The concentration of airborne fungi was related to the period of increase of dead plants in terms of nutrition source, and to the high relative humidity conditions including rainfall in terms of meteorological elements.

Estimation of Occupational Health Standard by Relationship between Airborne Lead Concentration by Particle Size and Lead in Blood (공기중 납입자의 크기 특성과 혈액중 납농도와의 관계에 의한 허용농도 측정)

  • Park, Dong-Wook;Paik, Nam-Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.2
    • /
    • pp.265-271
    • /
    • 1996
  • This study was conducted to investigate distribution of lead particles by operation of industry, to evaluate the effect of particle size on the absorption to workers, and to recommend the Occupational Health Standard for lead. Total lead concentrations in the secondary smelting industry were higher than those in the battery and litharge manufacturing industry. Total lead concentrations in other industries except radiator manufacturing industry exceeded the standard of $50{\mu}g/m^3$. Only radiator manufacturing industry indicated lead concentrations significantly lower than those in other industries(p<0.05). Average blood lead level of workers was $85.1{\mu}g/dl$ in secondary smelting manufacturing, $51.3{\mu}g/dl$ in the battery manufacturing, and below $40{\mu}g/dl$ in the litharge and radiator manufacturing industry. Blood lead levels of workers by industry were significantly different(p<0.05). From relationship between airborne lead concentrations by size and lead in blood, confidence limits of airborne lead concentration equivalent to $40{\mu}g/dl$ of permissible limit in blood, was $147.9-489.8{\mu}g/m^3$ as total lead and $28.8-79.4{\mu}g/m^3$ as ACGIH-RPM. It is recommended that two separate occupational health standards for lead should be established by particle size. Airborne concentration of $150{\mu}g/m^3$ as fatal lead dust and $30{\mu}g/m^3$ as respirable lead dust was recommended.

  • PDF

Characteristics of Airborne and Deposited Dust in Expressway Toll Booths (고속도로 톨게이트 부스의 공기 중 분진 및 침착 분진 특성)

  • Nam, Mi Ran;Jung, Jong-Hyoen;Phee, Young Gyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.1
    • /
    • pp.10-17
    • /
    • 2020
  • Objectives: This study was performed to evaluate the total dust, size-selective dust, and heavy metal concentrations generated inside and outside toll booths on an expressway and to identify the source through analysis of the components of the deposited dust. Methods: A total of 32 samples were collected from eight expressway toll booths. Each total dust sample was collected using a 37 mm PVC filter attached to a personal air sampler. Heavy metal samples were collected according to NIOSH method 7300. The size-selective dust concentrations were identified using a DustMate, and deposited dust was analyzed by WD-XRF and UHR-FE-SEM. Results: The geometric mean concentrations of the total dust inside and outside the toll booths were 337.5 ㎍/㎥ and 342.7 ㎍/㎥, respectively. The overall concentrations of TSP, PM10, PM2.5, and PM1 were higher on the outside of the toll booths, as the particle size of dust was larger, and higher in the underground passage as the dust size was smaller. The real-time analysis of the dust concentrations of TSP, PM10, PM2.5, and PM1 revealed to be higher at morning and evening times than other times because of heavy traffic. The element components of deposited dust in the toll booth were related to natural sources rather than artificial sources. Among the chemical components in the deposited dust analyzed by WD-XRF, SiO2 was the highest. For the elements analyzed by UHR-FE-SEM, C was the highest, followed by O, and Si. Conclusions: In order to reduce the dust concentrations around toll booths on an expressway, it is necessary to periodically clean surrounding areas such as underground passages, and it is also necessary to remove deposited dust inside the toll booth from time to time.

Optimization of Fugitive Dust Control System for Meteorological Conditions (기상조건별 비산먼지 관리체계 최적화 연구)

  • Kim Hyun-Goo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.6
    • /
    • pp.573-583
    • /
    • 2005
  • Fugitive dust, which is emitted in the ambient air without first passing through a stack or duct designed to control flow, is frequently generated by means of wind erosion from storage yards at Pohang Steel Wokrs. The size distribution of fugitive dust is mostly in the range of coarse particulate which is deposited as soon as emitted and less harm to human health; however $20\%$ of fugitive dust contains PM 10 known as one of most harmful airborne pollutant. Consequently, effective control and reduction of fugitive dust is strongly requested by the local society, but it is not easy so far because the generation and dispersion of fugitive dust highly depends on meteorological conditions, and it being occurred for irregularity. This research presented a fugitive dust control system for each meteorological condition by providing statistical prediction data obtained from a statistical analysis on the probability of generating the threshold velocity at which the fugitive dust begins to occur, and the frequency occurring by season and by time of the wind direction that can generate atmospheric pollution when the dispersed dust spreads to adjacent residential areas. The research also built a fugitive dust detection system which monitors the weather conditions surrounding storage yards and the changes in air quality on a real-time basis and issues a warning message by identifying a situation where the fugitive dust disperses outside the site boundary line so that appropriate measures can be taken on a timely basis. Furthermore, in respect to the spraying of water to prevent the generation of fugitive dust from the storage piles at the storage yard, an advanced statistical meteorological analysis on the weather conditions in Pohang area and a case study of fugitive dust dispersion toward outside of working field during $2002\∼2003$ were carried out in order to decide an optimal water-spraying time and the number of spraying that can prevent the origin of fugitive dust emission. The results of this research are expected to create extremely significant effects in improving surrounding environment through actual reduction of the fugitive dust produced from the storage yard of Pohang Steel Works by providing a high-tech warning system capable of constantly monitoring the leakage of fugitive dust and water-spray guidance that can maximize the water-spraying effects.

Exposure to Dust and Organic Gas during Chicken Entrance and Shipment Tasks in Poultry Farms (양계장에서 입식 및 출하작업시 분진과 가스상 물질의 노출 측정 조사)

  • Kim, Kyung-Ran;Kim, Hyocher;Lee, Kyungsuk;Chae, Hye-Seon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.4
    • /
    • pp.471-477
    • /
    • 2014
  • Objectives: This study was conducted to evaluate area exposure of airborne dust and organic gas during entrance and shipment of chicken in poultry farms Methods: Total dust was measured with NIOSH method 0500. The volume of distributed dust and organic gas(Ammonia, TVOC, Hydrogen Sulfide) were measured using direct reading instrument. Results: The range of concentrations of total dust in area sample was $0.07{\sim}4.91mg/m^3$ during the entrance of chicks and $4.37{\sim}9.4mg/m^3$ during shipment respectively. Concentration of ammonia reached approximately 9 ppm during shipment. There was a difference of concentration of total dust in the area sample between shipment and entrance tasks. Conclusions: It was found that the development of a special intervention program by type of task should be considered for reducing respiratory health effects among poultry farmers.

Development and Evaluation of a Dust Generator Using Soil Samples (토양 분진발생장치의 개발과 평가)

  • Lee, Ji-Yeon;Lee, Ki-Young
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.5
    • /
    • pp.383-390
    • /
    • 2010
  • Exposure to fugitive dust can contribute to several respiratory health problems, and proper sampling of fugitive dust is necessary to assess exposure. However, field sampling of soil dust encounters problems from spatial and temporal differences in soil properties, field operations, and meteorological conditions. To minimize these problems, we designed a dust generator that simulates dust generation from soil. The dust generator consisted of a rotating chamber where soil samples were loaded and tumbled, and a settling chamber, where airborne soil dust samples were collected. As standard operating conditions, we decided on 2 g soil mass, 10 min sampling time, and 20 rpm rotating speed, with a flow rate of 30 l/min, based on three common soil textures of loam, sandy loam and silt loam. To evaluate optimal operating conditions, we used mixtures of Joomoonjin silica sand and clay. Although the average $PM_{10}$ concentration of Joomoonjin silica sand was low, dust concentrations were increased by an increased content of clay. The dust concentrations were consistent across repeated experiments, and showed similar concentration profiles during the sampling time with mixtures of clay and sand (coefficient of variation was $13.6{\pm}w;7.1%$). The results demonstrated that these standard operating conditions were suitable for the dust generator, which can be used to investigate variations in soil properties that affect dust production and potential potency of fugitive dust exposure.

Density Distributions of Metallic Compounds in Particulate Matters (粒子狀 物質中 金屬成分의 密度分布)

  • 허문영;김형춘;손동헌
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.2 no.2
    • /
    • pp.9-18
    • /
    • 1986
  • For identification and apportionment of sources emitting particulate matters in environment, the multi-elemental characterization of size-density fractionated particulate matters was carried out. Eight types of samples were tested; soil, flyash released from burning of bunker-Coil, diesel oil, coal, and soft coal, urban road-way dust, urban dust fall, and airborne particulate matter. The fractions of particulate matters obtained by heavy liquid separation methos with a series of dichloromethane-bromoform were then analyzed using atomic absorption spectrophotometry for Ni, Cr, Cu, An, Fe, Al, and Mg. Each sample showed a different concentration profile as a function of density, and a number of useful conclusions concerning characterization of elemental distribution were obtained. From the density distributions of elements in soil, the maximum value was found for all elements in the density range of 2.2 $\sim 2.9g.cm^{-3}$, including the density of $SiO_2$. However, the distribution of metallic compounds with the density lower than $2.2g.cm^{-3}$ was prevalent in urban roadway dust, urban dust fall, and airborne particulate matter. And the density distribution curves of these urban dusts also have the higher distribution at the density of 2.2 - 2.9g.cm^{-3}$, including the density of wind-blown silica. This tendency generally was prevalent in the natural source elements, such as Al, Fe, Mn, and Mg. The maximum values were found in the density ranges of 1.3 $\sim 2.2g.cm^{-3}$ from the density distribution of elements in oil fired flyash. These distributions of anthropogenic source elements, such as Zn, Ni, Cu, and Cr were higher predominately than those of natural source elements. And the higher distribution was found in the density range of $2.2 \sim 2.9g.cm^{-3}$ from the density distribution of elements in coal and soft-coal fired flyash. These distributions showed similar patterns to soil. But anthropogenic source elements somewhat predominated at the density ranges of $1.3 \sim 2.2g.cm{-3} and 2.9g.cm^{-3}$ to soil. Therefore the higher distribution of anthropogenic source elements in the density ranges of $1.3 \sim 2.2g.cm^{-3} and 2.9g.cm^{-3}$ was considered as anthropogenic origin.

  • PDF

A Study on TSP and Pb Concentration in Atmosphere in Seoul (서울 일부지역의 도로변 대기중 분진 및 납 농도에 대한 조사연구)

  • 김지선;박석환;정문식
    • Journal of Environmental Health Sciences
    • /
    • v.18 no.1
    • /
    • pp.12-21
    • /
    • 1992
  • This study was performed to determine the concentrations of airborne TSP, Pb and street dust Pb in Kuro, Chongro, Namsan Tollgate and kwachun from August 15 to September 15, 1990.The results of this study are as follows. 1. Average airborne TSP concentrations in chongro and Kuro were 460$\mu$g/m$^{3}$ and 440$\mu$g/m$^}3}$, respectively, and exceeded the Korean air quality standards of 300$\mu$g/m$^{3}$. Average airborne TSP concentrations in Namsan Tollgate and Kwachun were 270$\mu$g/m$^{3}$ and 80$\mu$g/m$^{3}$, respectively, and didn't exceeded the Korean air quality standards of 300$\mu$g/m$^{3}$. The airborne TSP concentrations between Seoul area(Kuro, Chongro and Namsan Tollgate) and Kwachun area were significantly different (p < 0.01). 2. Average airborne Pb concentrations in Chongro, Kuro, Namsan Tollgate and Kwachun were 1.07, 0.55, 0.84 and 0.16$\mu$g/m$^{3}$, respectively. All the airborne Pb concentration at four area were below the Korean air quality standards of 1.5$\mu$g/m$^{3}$. The airborne Pb concentrations between Seoul area (Kuro, Chongro and Narnsan Tollgate) and Kwachun area were significantly different (p < 0.01). 3. Pb contents in street dusts in Kuro, Chongro, Namsan Tollgate and Kwachun were 9.30, 15.25, 18.17 and 3.16$\mu$g/g, respectively. The Pb contents in street dusts between Seoul area(Kuro, Chongro and Namsan Tollgate) and Kwachun area were significantly different (p < 0.01). 4. The airborne TSP and Pb concentrations were highly correlated(r=0.68), but the Pb concentrations in street dusts and atmosphere were poorly correlated(r=0.22).

  • PDF

Determination of Airborne Fiber Size and Concentration in RCF Manufacturing and Processing Factories (세라믹 섬유 제조 및 가공 공정에서 발생된 공기중 섬유의 농도 및 크기 분포)

  • 신용철
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.4
    • /
    • pp.21-28
    • /
    • 2000
  • Various man-made mineral fibers(MMMF) including refractory ceramic fiber(RCF) have been used widely in industries as insulation materials. The effect of fibrous dust on human health depends on fiber size, concentration (exposure level), and durability in biological system. Therefore, these parameters should be determined to evaluate accurately the potential risk of fibers on human health. The purpose of this study was to characterize the size of airborne fiber and the workers' exposure to airborne fibers in refractory ceramic fiber manufacturing and processing factories. Airborne fibers were collected on 25-mm mixed cellulose ester membrane filters at personal breathing zones, and analyzed by A and B counting rules of the National Institute for Occupational Safety and Health(NIOSH) Method # 7400. The average ratios of the fiber density by B rule to the fiber density by A rule was 0.84. This result indicates that the proportion of respirable fibers (<3 ${\mu}{\textrm}{m}$ diameter) in air samples was high. The average diameter and length of airborne fibers were 1.05${\mu}{\textrm}{m}$ and 35${\mu}{\textrm}{m}$, respectively. The average fiber concentrations (GM) of all personal samples was 0.26f/cc, and the average concentration was highest at blanket cutting and packing processes. The fifty seven percent of personal air samples was exceeded the proposed American Conference of Governmental Industrial Hygienists(ACGIH) Threshold Limit Value(TLV), i.e. 0.2 f/cc. It was concluded that the RCF industrial workers had the higher potential health risk due to small fiber diameter, long fiber length, and high exposure level to the airborne fibers.

  • PDF