• 제목/요약/키워드: air-water

검색결과 6,822건 처리시간 0.047초

고밀도 내부부하 중심 건물의 에너지 절약적 공조방식에 대한 연구 (Viability of HVAC System for Energy Conservation in High Density Internal-load Dominated Buildings)

  • 조진균;정차수;김병선
    • 설비공학논문집
    • /
    • 제22권8호
    • /
    • pp.530-537
    • /
    • 2010
  • With the advancement of technology, the density of IT equipment, heat load and power consumption continue to increase in high density internal-load dominated buildings as datacenters. To improve the HVAC system's energy performance and efficiency, there is a need to find methods of using outside air. Through cooling tower control that is based on outside wet-bulb temperature, the water-side economizer made it possible to achieve a maximum energy performance improvement of about 16.6% over the basic chilled water system, whereas the air-side economizer, through control based on outdoor air enthalpy, made it possible to achieve about 42.4% improvement.

연안해역 기온과 수온의 상관관계 및 이력현상 분석 (Correlation and Hysteresis Analysis between Air and Water Temperatures in the Coastal Zone - Masan Bay)

  • 조홍연;이길하;조경준;김준성
    • 한국해안해양공학회지
    • /
    • 제19권3호
    • /
    • pp.213-221
    • /
    • 2007
  • 전지구적으로 지구 온난화 문제가 대두되고 있는 현 상황에서, 기온변화에 수반되는 수온변화 반응을 파악하기 위하여 해양수산부에서 제공하는 마산만 연안해역의 기온 및 수온 관측자료를 이용하여 기온과 수온의 관계를 분석하였다. 수온과 기온의 무차원 자기상관함수와 교차상관함수 변화를 분석한 결과, 지체시간 10일 이내에서는 상관계수가 0.9 이상으로 매우 크게 나타났으며, 지점별로 수온의 상관계수보다 기온의 상관계수가 크게 나타나는 것으로 파악되었다. 마산만 기온 및 수온자료를 수온상승기, 수온하강기로 구분하여 분석한 결과, 수온상승기에는 MA1 지점, MA2 지점의 기울기가 각각 0.829, 0.774로 나타났으며, 수온하강기에는 MA1 지점, MA2 지점의 기울기가 각각 1.385, 1.444로 기온상승기에 비하여 기온하강기의 기울기가 약 1.75배 정도 크게 나타나고 있으며, 명확한 이력현상으로 파악되었다. 따라서, 마산만 연안해역의 기온-수온 상관관계를 보다 정확하게 결정하기 위해서는 기온-수온의 계절적인 이력현상을 포함하여야 하며, 이 경우 기온을 이용한 수온 추정결과의 정확도가 향상되는 것으로 파악되었다.

환경오염공정시험기준과 KS ISO규격의 일원화에 관한 연구 - 먹는 물 및 실내공기질 - (Study on the unification between KS I ISO standard and official test method enacted by Korean Ministry of Environment - drinking water and indoor air quality -)

  • 이정일;이주희;이정희;이준희;이원석;김지인;김보경;최성헌
    • 분석과학
    • /
    • 제25권2호
    • /
    • pp.102-113
    • /
    • 2012
  • 현행 환경오염공정시험기준 중 먹는 물 수질공정시험기준과 실내공기질 공정시험기준에 대해 국제규격에 부합화된 KS ISO규격과의 일원화에 관해 연구하였다. KS규격 23,000여종을 대상으로 먹는 물 및 실내공기질관련 KS 규격을 조사하였다. 환경분야관련 KS규격은 KS I로 분류되며, 총 653종으로 조사되었으며, 이중 국제규격에 부합화된 KS I 규격은 583종으로 조사되었다. 먹는 물 수질공정 시험기준은 총 100개 기준을 대상으로 ISO/TC 147 "Water Quality" 관련 KS 규격 총 232종을 비교 검토하였으며, 실내공기질 공정시험기준은 "ISO/TC 146 "Air Quality" 관련 KS 규격 총 95종 규격을 비교 검토하였다. 문헌검토와 비교시험을 통해 먹는 물 및 실내공기질 공정시험기준과 일원화 가능한 국제규격에 부합화된 KS규격 연구결과 먹는물수질공정시험 100개 기준 중 사전일원화 완료 23개 기준, 일원화 가능 29개 기준, 일원화 불가 12개 기준, 대응 규격 없는 기준이 36개로 평가되었으며, 실내공기질 공정시험기준 17개 기준 중 사전일원화 완료 1개 기준, 일원화 가능 3개 기준, 일원화 불가 3개 기준, 대응규격 없는 기준이 10개 기준으로 평가되었다.

공조설비의 필터차압 변화에 따른 에너지 소비성능 평가 (Evaluation of Energy Consumption of HVAC System for Air Filter Pressure Difference Change in Commercial Buildings)

  • 원근호;곽노열;허정호
    • 설비공학논문집
    • /
    • 제16권12호
    • /
    • pp.1227-1233
    • /
    • 2004
  • Air handling unit (AHU)'s air filter pressure difference is important for energy consumption and indoor air quality. Both energy Performance data and air filter differential pressure of AHU in real office buildings were monitored and analyzed to investigate quantitatively energy impact as dust buildup level on air filter grows. We also modeled and simulated CAV system using HVACSIM+ program to examine the energy effect of dust buildup on filters. Through analysis of time series pressure drop data, the filter pressure difference rate has been increased due to cumulative supply air flow rate increase. As filter pressure drop increased to 1 inch water column, it is found that the supply air flow rate was decreased by 10%, the chilled water flow rate was increased by 5.9% and the pump energy consumption was increased to 5.9%.

상수도관의 물 흐름 방향을 고려한 공기주입 세척 및 단방향 플러싱 공법의 세척 효과 비교 연구 (Comparative study on cleaning effects of air scouring and unidirectional flushing considering water flow direction of water pipes)

  • 서지원;이규상;김기범;형진석;김태현;구자용
    • 상하수도학회지
    • /
    • 제33권5호
    • /
    • pp.353-366
    • /
    • 2019
  • This research proposes an optimal flushing operation technique in an effort to prevent secondary water pollutions and accidents in aged pipes, and to improve the cleaning effect of unidirectional flushing. Water flow directions were analyzed using EPANET 2.0, while flushing and air scouring experiments in forward and reverse directions were performed in the field. In 42 experiments, average residual chlorine concentration and turbidity were improved after cleaning compared to before cleaning. It was found that even when the same cleaning method was used, further improvement of cleaning effect was possible by applying air injection and reverse direction cleaning techniques. By means of one-way ANOVA(Analysis of variance), it was also possible to statistically verify the need of actively utilizing air injection and reverse direction cleaning. Based on correlation between turbidity and TSS, the total amount of suspended solids removal was estimated for 874 flushing operations and 194 air scouring operations. The result showed that air scouring used more discharge water than flushing by an average of $4.9m^3$ yet with larger amounts of suspended solids removal by an average of 145.9 g. The result of analysis on turbidity values from 887 flushing operations showed low cleaning effect of unidirectional flushing for the pipes with diameters over 300 mm. In addition, the turbidity values measured during cleaning showed an increasing tendency as pipe age increased. The methodology and results of this research are expected to contribute to the efficient maintenance and improvement of water quality in water distribution networks. Follow-up research involving the measurement of water quality at regular time intervals during cleaning would allow a more accurate comparison of discharge water quality characteristics and cleaning effects between different cleaning methods. To this end, it is considered necessary to develop a standardized manual that can be used in the field and to provide relevant trainings.

평판관 열교환기 내 공기-물 2상류 분지 (Distribution of Air-Water Two-Phase Flow in a Flat Tube Heat Exchanger)

  • 김내현;박태균;한성필;신태룡
    • 설비공학논문집
    • /
    • 제18권9호
    • /
    • pp.687-697
    • /
    • 2006
  • The air and water flow distribution are experimentally studied for a heat exchanger composed of round headers and 10 flat tubes. The effects of tube protrusion depth as well as mass flux, and quality are investigated, and the results are compared with the previous 30 channel results. The flow at the header inlet is annular. For the downward flow configuration, the water flow distribution is significantly affected by the tube protrusion depth. For flush-mounted geometry, significant portion of the water flows through frontal part of the header. As the protrusion depth increases, more water is forced to the rear part of the header. The effect of mass flux or quality is qualitatively the same as that of the protrusion depth. Increase of the mass flux or quality forces the water to rear part of the header. For the upward flow configuration, different from the downward configuration, significant portion of the water flows through the rear part of the header. The effect of the protrusion depth is the same as that of the downward flow. As the protrusion depth increases, more water is forced to the rear part of the header. However, the effect of mass flux or quality is opposite to the downward flow case. As the mass flux or quality increases, more water flows through the frontal part of the header. Compared with the previous thirty channel configuration, the present ten channel configuration yields better flow distribution. Possible explanation is provided from the flow visualization results.

기후변화에 따른 미래 하천 수온 예측을 위한 비선형 기온-수온 상관관계 구축 (Building a Nonlinear Relationship between Air and Water Temperature for Climate-Induced Future Water Temperature Prediction)

  • 이길하
    • 환경정책연구
    • /
    • 제13권2호
    • /
    • pp.21-38
    • /
    • 2014
  • 지구의 온난화로 인하여 기온이 상승하고 이에 대응하여 수온 증가가 감지되고 있다. 하천의 수온 변화는 수질과 생태계, 특히 용존산소변화와 생물체의 이동으로 이어진다. 기온 변화가 하천의 수질과 생태 환경에 미치는 영향을 추정하기 위해서 수온 상승의 시기와 하천 어종에 대한 이해가 필요한데 이를 위하여 미래의 수온을 예측할 필요가 있다. 환경부 산하 국립환경과학원에서 설치한 국가수질관측망 자료와 기상청 기상관측소의 기온 자료를 활용하여 기온-수온 비선형 상관관계모형을 구축하였다. 기온-수온 대표 관계인 비선형 로지스틱(Logistic) 함수에 포함된 4개의 매개변수를 결정하기 위하여 SCE최적화 기법을 이용하였다. 기온-수온 상관관계는 시간규모에 따른 최대 온도와 최소 온도에 차이가 있으나 수질 또는 생태 반응의 적당한 시간규모에 해당하는 주 평균 온도를 이용하여 분석하였다. 전반적으로 우리나라 하천의 기온-수온 관계는 선형보다는 비선형 모형에서 NSC와 RMSE가 더 우수하여 비선형 모형이 적합한 것으로 나타났다. 연구 결과는 미래의 기온 상승 변화에 반응하는 수질, 수문 및 생태반응에 대비하여 공학기술자 또는 정책입안자에게 적절한 기후변화 대책 방향을 설정하는 데 지침을 제공할 것이다.

  • PDF

공기구동 이젝터를 이용한 ABB (Air Bubble Barrier)의 기포거동 특성 연구 (II): 기포거동 특성의 비교 분석 (A Study on Bubble Behavior Generated by an Air-driven Ejector for ABB (Air Bubble Barrier) (II): Comparison of Bubble Behavior with and without Ejector)

  • 서현덕;알리유 무사 알리유;김효근;김경천
    • 한국가시화정보학회지
    • /
    • 제15권2호
    • /
    • pp.59-67
    • /
    • 2017
  • To verify floatability of ABB (Air bubble barrier), we compared bubble swarm behavior with and without the air-driven ejector. Experiment was conducted using the fabricated air-driven ejector with 5 mm nozzle on the bottom of 1 m3 water tank. Reynolds number of air in the nozzle was ranged 1766-13248. We analyzed data with statistical method using image processing, particle mage velocimetry (PIV) and proper orthogonal decomposition (POD) analysis. As a result of POD analysis, there was no significant eigenmode in bubbly flow generated from the ejector. It means that more complex turbulent flows were formed by the ejector, thereby (1) making bubbles finer, (2) promoting three-dimensional energy transfer between bubble and water, and (3) making evenly distributed velocity profile of water. It is concluded that the air-driven ejector could enhance the performance of ABB.

이유체노즐의 액체이송공기 공급방법에 따른 어뎁터 내부유동특성에 관한 해석적 연구 (Effects of Carrier Air Supplying Parameter on the Internal Flow Characteristics of an Adaptor in Two-Fluid Nozzle)

  • 박설혜;조민호;김덕진;이지근;노병준
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.65-70
    • /
    • 2008
  • The numerical simulation on the internal flow characteristics of the adaptor in a two-fluid nozzle has been performed to investigate the effects of carrier air supplying parameters using a commercial code. The four adaptor models with the different positions in the carrier air supplying port were considered at the fixed conditions of urea-water solution and carrier air supplying. As the results from the numerical analysis, the internal pressure of the adaptor was varied with the port position for carrier air supplying, and it shows lower pressure value than the atmospheric pressure. Consequently, the flowrate of urea-water solution issuing from the feeding injector with the adaptor varied up to 30% with the port positions for the carrier air supplying. When the carrier air is supplied from the side from the feeding injector axis and the upper part from the feeding injector tip, the flowrate of urea-water solution issuing from the feeding injector with the adaptor show higher value than other carrier air supplying conditions.

  • PDF

녹지 조건에 따른 최고기온의 비교연구 (Comparative Study of Maximum Temperature Condition in Green Space)

  • 윤용한
    • 아시안잔디학회지
    • /
    • 제15권4호
    • /
    • pp.181-186
    • /
    • 2001
  • 본 연구는 토지피복현황과 수림형태 등이 다양한 도시녹지를 대상으로 기온저감효과와의 관련성을 파악한 결과 아래와 같은 효과가 실증되었다. 그 결과를 바탕으로 녹지 내의 토지피복현황과 기온분포, 토지피복비율 및 녹적량과 기온 저감효과와의 관련성을 회귀분석 등에 의해 해석하였다. 그 결과, 포장면과 나지 주변에서는 고온역이, 수림지와 수면 주변에서는 저온역이 형성되었다. 특히, 교목+소교목층으로 피복되어 있는 구역과 수림으로 둘러싸인 수면, 소하천 주변에는 상대적으로 낮은 기온이었다. 또한, 저온을 형성하는 메커니즘은 토지피복비율(수림지, 초지, 수면)등이고, 그 토지피복의 종류와 비율에 따라 기온저감효과가 서로 달랐다. 더욱이 녹정량과 기온과의 관계는 부의 상관을 나타냈고, 그 효과는 교목, 소교목, 관목의 순이다.

  • PDF