• Title/Summary/Keyword: air-borne bacteria

Search Result 15, Processing Time 0.029 seconds

Optimization of monitoring methods for air-borne bacteria in the environmental conditions of pig facilities (무균 돈사 환경 모니터링을 위한 대기 중 미생물 탐지기법 확립)

  • Lee, Deok-Yong;Seo, Yeon-Soo;Kang, Sang-Gyun;Yoo, Han Sang
    • Korean Journal of Veterinary Research
    • /
    • v.46 no.3
    • /
    • pp.255-261
    • /
    • 2006
  • Experimental animals have been used to biological and medical purposes and the animals must be, for these purposes, healthy and clean to microbial infection. However, the animals can be easily exposed to pathogenic microorganism via several routes. Of the routes, environmental conditions are the most important factors to keep the animals healthy and clean, especially air condition. Monitoring of air-condition has been required to keep the animal healthy and clean. However, any guideline is not available for experimental conditions with pigs. Therefore, the sampling times and points were compared in different conditions to establish an optimal protocol for monitoring of air borne bacteria. Tryptic soy agar(TSA), blood agar containing 5% defibrinated sheep blood and Sabraud dextrose agar(SDA) were used as media to capture total bacteria, pathogenic bacteria and fungi, respectively. Two methods, compulsive capture using an air-sampler and capturing fall-down bacteria were used to capture the microorganisms in the air. The points and time of capturing were different at each experiment. Air borne microorganisms were captured at three and five points in the open and closed equipments, respectively. Air was collected using an air-sampler for 1 min and 5 min and the agar plates as open status were left from 30 min to 2hr. At first, we monitored an experimental laboratory which dealt with several pathogenic bacteria and then, a protocol obtained from the investigation was applied to open or close experimental conditions with pigs. Number of bacteria was high from 10:00 to 15:00, especially on 13:30-15:30 but sharply decreased after 17:00. The tendency of the number of bacteria was similar between two methods even though the absolute number was higher with air sampler. Critical difference in the number of cells was observed at 5 min with air sampler and 2 hr with fall-down capturing method. However, 1 min with air sampler and 1 hr with fall-down capturing were the best condition to identify bacterial species collected from the air. Number of bacteria were different depending on the sampling points in closed condition but not in opened condition. Based on our results, a guide-line was suggested for screening air-borne microorganism in the experimental conditions with pigs.

Study on Reducing Methods of Natural Food-borne Pathogenic Microorganisms Originated from Saengshik (생식 중 자연환경유래 위해미생물 저감화 방법에 관한 연구)

  • Chang, Tae-Eun;Han, Jeong-Su;Song, Ok-Ja;Chung, Dong-Hwa;Shin, Il-Shik
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.6
    • /
    • pp.1020-1025
    • /
    • 2004
  • In previous paper, contaminations of food-borne pathogenic bacteria of Saengshik was found to occur during processing, because detection rates of food-borne pathogenic bacteria in final products were higher than those of raw materials. In this study, methods to reduce food-borne pathogenic bacteria and improved manufacturing process were developed for microbial safety of Saengshik. Food-borne pathogenic bacteria in raw materials were reduced to about 0.5-2.0 log cfu/g when seven kinds of raw materials were washed with electrolyzed water and ozonated water, but food-borne pathogenic bacteria could not be removed completely. After improvement of manufacturing process, numbers of food-borne pathogenic bacteria were same or decreased to levels of raw materials. Gaseous ozone and Biocon could control air-borne bacteria under $1{\times}10^1$ cfu/1000 L of air in pulverization and mixing rooms.

The Study on the Performance Estimation of UVC Air Sterilizer for Preventing Transmission of Air Borne Contagion (공기감염 전파방지를 위한 UVC 공기살균기 성능평가에 관한 연구)

  • Choi Sang Gon;Hong Jin Kwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.6
    • /
    • pp.581-586
    • /
    • 2005
  • Recently, the use of UVGI system has been increasing in both medical and nonmedical buildings for the control of environmental microorganisms. In the present study, irradiance performance test of UVC lamp was carried out and indoor air sterilization effect of UV ray for preventing transimission of air borne contagion was investigated by using manufactured UVC air sterilizer. Experimental results show that the effective irradiance of UVC lamp is strongly dependent on air velocity and temperature in irradiance performance test. An individual microbiological killing effectiveness experiment also shows that the average kill rate of two microbiological samples such as bacteria and fungus is about $92\%$ by using manufactured UVC air sterilizer. Additionally irradiance performance experimental results also show that the ballast is very important factor to keep up irradiance performance of UVC lamp.

The study on the multizone modeling for preventing transmission of air borne contagion (실내 미생물오염 전파방지를 위한 멀티죤 모델링에 관한 연구)

  • Choi, Sang-Gon;Lee, Hyun-Woo;Hong, Jin-Kwan
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.429-435
    • /
    • 2006
  • In this study multi-zone modeling program CONTAM 2.4 which is developed by NIST is used for modeling the air disinfection system which is consist of dilution, filtration, ultra violet germicidal irradiation (UVGI) for removing the indoor microorganism such as bacteria and fungus. Developed models those protect occupants against indoor microorganism generated in our daily life are enable to use for immune building simulation tool. Also, results indicate that those models are enable to compute the real situation that is almost impossible of carrying out experiment and identify the disinfection rate with highly reliance. Results also suggest that engineers will use these models as a design tool for the immune building system.

  • PDF

Toxin Gene Profiles and Toxin Production Ability of Food-borne Pathogens Isolated from Indoor Air from Lunchrooms at Child Care Centers (보육시설 급식실 실내공기에서 분리된 식중독 세균의 독소 유전자 및 독소 생산 특성)

  • Kim, Jung-Beom;Kim, Jong-Chan
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.6
    • /
    • pp.510-519
    • /
    • 2012
  • Objectives: This study was conducted in order to evaluate the microbiological contamination of the indoor air of the lunchrooms at child care centers and investigate the toxin genes and toxin production ability of food-borne pathogens. Methods: A total of 64 child care centers were sampled to test total aerobic bacteria, coliform bacteria, fungi, Staphylococcus aureus, Bacillus cereus and Salmonella spp. according to the Korea Food Code. All toxin genes of pathogens were detected using the Polymerase Chain Reaction method. The Sthaph. aureus enterotoxin was detected by a Staphylococcus aureus enterotoxin-reversed passive latex agglutination kit. The heamolysin BL (HBL) and non-heamolytic enterotoxin (NHE) produced by B. cereus were detected using a B. cereus enterotoxin-reversed passive latex agglutination kit and Bacillus diarrheal enterotoxin visual immunoassay kit, respectively. Results: The means of total aerobic bacteria and coliform bacteria were $1.91{\pm}1.84$ log CFU/plate and $0.47{\pm}0.62$ log CFU/plate, respectively. The mean of fungi also showed $0.59{\pm}0.71$ log CFU/plate. Among the pathogenic bacteria tested in this study, Staphy. aureus and B. cereus were detected in four (6.3%) and 21 (32.8%) out of 64 indoor air samples from lunchrooms in child care centers, respectively. All Staphy. aureus tested in this study possessed no toxin genes and did not produce enterotoxin. The detection rate of nheABC, hblCDA, entFM and ces toxin gene in B. cereus was 100, 57.1, 76.2 and 0%, respectively. B. cereus isolates were classified into four groups according to the presence or absence of toxin genes. The nheABC gene was the major toxin gene among B. cereus tested in this study. The HBL was detected in 11 out of 21 B. cereus isolates (52.4%) and three B. cereus isolates produced NHE (14.3%). Conclusion: The results indicated that the contamination by microorganisms in the indoor air of lunchrooms was unqualified to supply safe catering in child care centers. The ongoing control of indoor air quality is required.

Microflora of Manufacturing Process and Final Products of Saengshik (시판생식의 제조공정 및 최종제품의 미생물분포)

  • Chang, Tae-Eun;Moon, Sung-Yang;Lee, Kun-Wook;Park, Jang-Mi;Han, Jeong-Su;Song, Ok-Ja;Shin, Il-Shik
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.501-506
    • /
    • 2004
  • Microflora and contamination process of Saengshik products were investigated to ensure microbial safety of Saengshik. Food-borne pathogenic bacteria, such as Staphylococcus aureus, Bacillus cereus, and Clostridium perfringens detected mainly from grains were not removed by washing with tap water and freeze-drying. Contaminations of food-borne pathogenic bacteria occurred through raw material powder processed at other factories and during actual product manufacturing process, because detection rates of final products were higher than those of raw materials. Concentration of food-borne pathogenic bacteria increased with advancing of process after first pulverization. Dusts of powder and powder attached to machine were good media for air-borne microorganisms and caused to increase of food-borne pathogenic bacteria during process. Improvement of manufacturing process and sanitary control of machines arc necessary to ensure microbial safety of Saengshik.

A Study on the Multizone Modeling for Preventing Transmission of Air Borne Contagion (실내 미생물오염 전파방지를 위한 멀티존 모델링에 관한 연구)

  • Choi, Sang-Gon;Lee, Hyun-Woo;Hong, Jin-Kwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.11
    • /
    • pp.933-940
    • /
    • 2006
  • In this study multi-zone modeling program CONTAM 2.4 developed by NIST is used for estimating the air disinfection rate of the interior of a room which is set up the indoor air disinfection system with filter and ultra violet germicidal irradiation (UVGI). Developed models those enable to predict the transmission of air home contagion such as bacteria and fungus generated in our daily life are useful model for designning air cleaning & ventilation system of building. Also, results indicate that these models are enable to compute the real situation that is almost impossible of carrying out experiment in an actual condition due to biohazard problems and suggest that engineers will use these models as a design tool for the future immune building system.

Seed-borne Pathogenic Bacterium Interact with Air-borne Plant Pathogenic Fungus in Rice Fields

  • Jung, Boknam;Park, Jungwook;Kim, Namgyu;Li, Taiying;Kim, Soyeon;Bartley, Laura E.;Kim, Jinnyun;Kim, Inyoung;Kang, Yoonhee;Yun, Ki-Hoon;Choi, Younghae;Lee, Hyun-Hee;Lee, Kwang Sik;Kim, Bo Yeon;Shon, Jong Cheol;Kim, Won Cheol;Liu, Kwang-Hyeon;Yoon, Dahye;Kim, Suhkman;Ji, Sungyeon;Seo, Young Su;Lee, Jungkwan
    • 한국균학회소식:학술대회논문집
    • /
    • 2018.05a
    • /
    • pp.33-33
    • /
    • 2018
  • Air-borne plant pathogenic fungus Fusarium graminearum and seed-borne plant pathogenic bacterium Burkholderia glumae are cause similar disease symptoms in rice heads. Here we showed that two pathogens frequently co-isolated in rice heads and F. graminearum is resistant to toxoflavin produced by B. glumae while other fungal genera are sensitive to the toxin. We have tried to clarify the resistant mechanism of F. graminearum against toxoflavin and the ecological reason of co-existence of the two pathogens in rice. We found that F. graminearum carries resistance to toxoflavin as accumulating lipid in fungal cells. Co-cultivation of two pathogens resulted in increased conidia and enhanced chemical attraction and attachment of the bacterial cells to the fungal conidia. Bacteria physically attached to fungal conidia, which protected bacterium cells from UV light and allowed disease dispersal. Chemotaxis analysis showed that bacterial cells moved toward the fungal exudation compared to a control. Even enhanced the production of phytotoxic trichothecene by the fungal under presence of toxoflavin and disease severity on rice heads was significantly increased by co-inoculation rather than single inoculation. This study suggested that the undisclosed potentiality of air-born infection of bacteria using the fungal spores for survival and dispersal.

  • PDF

UV Immune System of Personalized Space (개별공간의 자외선 살균 시스템)

  • Jeong, Ky-Bum;Choi, Sang-Gon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.1
    • /
    • pp.63-70
    • /
    • 2009
  • The air sterilization systems are investigated experimentally in this paper. The goal is to reduce bacteria, mold and viruses in office air by using a UV sterilizer installed inside a partition panel and wall-mounted unit. These systems allow occupants to turn the system on/off and to control the incoming air speed and direction. The partition air sterilization system conditions and sterilizes the air, and then delivers the clean air into the personal task area through the partition panels, which are connected to the pressurized under-floor plenum. Room air exits through the return grills mounted on the ceiling. The wall-mounted air sterilization system sterilizes the air, and then delivers the clean air to the personal task area from the wall. In this study a full-size experimental environment is established to investigate the immunization performance of these air sterilization systems. A typical office space scale is used in this study in order to find an optimal system to achieve a sterilized healthy micro-environment. Multiple system parameters, including volume flow rate and velocity of supplied air, were regulated during the experiments. The more air contact these air sterilization systems had, the better disinfection performance. Over 90% of eradication ratios were obtained by these two air sterilization systems. The results indicate that these systems can efficiently disinfect office air contamination.

Concentrations of Airborne Microorganisms and Endotoxins in Duck Houses (오리 사육장의 공기 중 부유 미생물 및 내독소 노출 농도)

  • Lee, Yun-Keun;Kim, Won;Kim, Hyo-Cher;Park, Dong-Uk
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.3
    • /
    • pp.191-198
    • /
    • 2010
  • The aim of this study was to determine the concentrations of air-borne microorganisms (bacteria, fungi, gram negative bacteria (GNB), endotoxins, and respirable suspended particles (RSPs), and their correlation with environmental parameters (temperature, humidity, and carbon dioxide levels) in duck houses. The mean concentrations of bacteria, fungi, and GNB were very high (> $10^6\;CFU/m^3$), and endotoxin levels exceeded $10^3\;EU/m^3$. Among the various work stages, in the task of receiving ducks, bacteria were $6.2{\times}10^6;CFU/m^3$, and GNB were $5.4{\times}10^6\;CFU/m^3$, while RSPs levels were $397.6\;{\mu}g/m^3$ and endotoxin levels were $47.2{\times}10^3\;EU/m^3$ in the task of dividing the ducks, and fungi were $4.9{\times}10^6\;CFU/m^3$ in the task of shipping the ducks. The concentrations of RSPs and endotoxins were significantly higher in tasks involving greater movement of ducks in the house, relative to tasks involving little movement of ducks (p<0.05). Further, with progression in growth of the ducks, the concentrations of bacteria, GNB, endotoxins, and RSPs were significantly increased. There was significant correlation between levels of GNB with bacteria (r=0.75) and fungi (r=0.86), endotoxins with RSPs (r=0.75), bacteria with fungi (r=0.39), and carbon dioxide with RSPs (r=0.38), bacteria (r=0.33), and endotoxins (r=0.31). These results suggest considerable respiratory hazard for farmers in these environments.