• Title/Summary/Keyword: air-blower

Search Result 239, Processing Time 0.031 seconds

A Study on Performance Evaluation for Oil Mist Removal using a High-speed Centrifugal Cyclone (고속원심분리 사이클론을 이용한 오일 미스트 제거 성능 연구)

  • Kim, SooYeon;Kim, Jin-Seon;Sung, Jin-Ho;Han, Bangwoo;Kim, Yong-Jin;Kim, Hak-Joon
    • Particle and aerosol research
    • /
    • v.15 no.4
    • /
    • pp.139-148
    • /
    • 2019
  • This study was performed for the application of a high-speed centrifugal cyclone to shale gas mining process. This device uses the centrifugal force to control particles similar to typical cyclones, and the disk located inside the cyclone is forced to rotate using a motor. The pressure difference occurred during the rotating of disk. Hence, inflow rate was generated without a blower fan. In addition, flow rate increased with elevating rpm of motor. The installing the disk in multiple stages on the inner rotor increased the instantaneous disk outlet flow. Hence, the control efficiency of oil particle increased from 1.05% to 31.2%. By modifying the structure of the disk so that the air flow to the opposite direction of the cyclone, the control efficiency of oil particles increased to 81.5%. By increasing the capacity of the motor and the size of the disk, the flow rate was increased to 2.5 ㎥/min because the rpm of motor and pressure difference increased. As rpm of motor increased, the cut-off diameter (dpc) became smaller. Unlike the Lapple's equation, dpc was inversely proportional to the effective number of rotations (Ne). The control efficiency was maintained even if the concentration of oil particles increased, for this reason, the higher the oil concentration, the more particles were accumulated and controlled.

Effects of Microwave Radiation on the Moisture Content and Subsequent Aerobic Composting of Pig Manure (돼지분뇨에 마이크로파 반응시간에 따른 호기성 퇴비화 과정에서 수분증발량 및 특성변화에 관한 연구)

  • Kwag, Jung-Hoon;Jeong, Kwang-Hwa;Choi, Dong-Yoon;Kim, Jung-Gon;Han, Duk-Woo;Han, Man-Hee;Yoo, Young-Hee;La, Chang-Six
    • Journal of Animal Environmental Science
    • /
    • v.19 no.2
    • /
    • pp.109-116
    • /
    • 2013
  • In this experiment, we hypothesized that pre-conditioning pig manure with microwave radiation can effectively eliminate moisture and consequently, cut down a need for expensive sawdust. For the experiment, pig manure/sawdust mixture of water content 79% was divided into 4 groups and each of them were treated with microwave for predetermined time periods, 5, 10, 15, 20 minutes. Subsequently, they were transferred to chambers (20 L) and aerobically composted. During the 2 weeks composting, air was supplied using blower (150 L per $1m^3$) and temperature and other variables were monitored continuously. When the data were analyzed, it was found, (1) moisture content was significantly decreased as radiation period extended. (2) weight reduction of compost after completion of composting was noticeably bigger in 15 min radiated group(31%), compared with 5 min (24.6%), 10 min (21.4%), 20 min (27.2%) radiated groups.

The Measurement of Airtightness Performance of Multi-Family Housing (다가구 및 다세대 원룸주택의 기밀성능 실측연구)

  • Baek, Nam-Choon;Han, Seung-Hyeon;Lee, Wang-Je;Yoon, Jong-Ho;Shin, U-Cheul
    • KIEAE Journal
    • /
    • v.14 no.5
    • /
    • pp.117-121
    • /
    • 2014
  • Even though a study of airtightness performance of apartment and detached house have been done constantly, there are few of studies of multi-family housing which increasing every year. Therefore, this study analyzed airtightness performance of 20 households of one room in Daejeon to investigate airtightness performance standard. All experiments were performed under the same conditions except sealing windows to investigate airtightness performance without sealing windows (natural condition) and airtightness performance with sealing windows of studio apartment. As results, (1) average ACH50 without sealing windows was 19.2/h for pressurization, and 12.8/h for depressurization and (2) average ACH50 with sealing windows was 16.0/h for pressurization, and 10.7/h for depressurization and ACH50 in both condition, ACH50 under pressurization was about 50% higher than that under depressurization. Throughout this experiment, we can figure out that about 16% of air infiltration rate is occurred in windows, and the other 84% is occurred in rest of places such as Junction structure, socket and ventilating opening.

A Study on the Optimal Control Algorithms for the Advanced Wastewater Treatment Process with Variable Hydrodynamic Flow Patterns (유로 변경식 고도하수처리 공정의 최적 제어 알고리즘에 관한 연구)

  • Kang, Seong-Wook;Cho, Wook-Sang;Huh, Hyung-Woo
    • Applied Chemistry for Engineering
    • /
    • v.16 no.2
    • /
    • pp.217-225
    • /
    • 2005
  • Because of the limitation of controllable operation variables for the wastewater treatment process with variable hydrodynamic flow patterns, it may preclude the use of this type of nutrient removal activated sludge process. As the operation variables, only temperature and dissolved oxygen (DO) have been used to operate the process. This study made an effort to improve treatment efficiency and operability of the process by the following methodologies: 1) process and operation data analysis using process simulation, 2) determination of optimal control logic or algorithm using a pilot-scaled experimental apparatus and its operations, and 3) application of experimental and simulation results to find the optimal process operation modes. In this study, it was found that the optimal operation mode named 'save mode' in the basis of process variables, such as the ammonia-nitrogen concentration of inlet flow, temperature and flow rate, can reduce the operation cost comparing with the present normal operation mode. And the stable conditions in nitrification were also shown by the proportional control of DO with the inlet air flow rate of blower and the mixing rate of mechanical aeration.

Modeling of PEM Fuel Cell System-Sensitivity Analysis of System Efficiency with Different Main Operating Parameters of Automotive Fuel Cell System (PEM 연료전지 시스템 모델링-자동차용 연료전지 시스템의 주요 작동 변수 변경에 따른 시스템 효율 민감도 분석)

  • KIM, HAN-SANG;KANG, BYUNGGIL;WON, KWONSANG
    • Journal of Hydrogen and New Energy
    • /
    • v.30 no.5
    • /
    • pp.401-410
    • /
    • 2019
  • The operating conditions greatly impact the efficiency and performance of polymer electrolyte membrane (PEM) fuel cell systems and must be properly managed to ensure better performance and efficiency. In particular, small variations in operating conditions interact with each other and affect the performance and efficiency of PEM fuel cell systems. Thus, a systematic study is needed to understand how small changes in operating conditions affect the system performance and efficiency. In this paper, an automotive fuel cell system (including cell stack and balance of plant [BOP]) with a turbo-blower was modeled using MATLAB/Simulink platform and the sensitivity analyses of main operating parameters were performed using the developed system model. Effects of small variations in four main parameters (stack temperature, cathode air stoichiometry, cathode pressure, and cathode relative humidity) on the system efficiency were investigated. The results show that cathode pressure has the greatest potential impact on the sensitivity of fuel cell system efficiency. It is expected that this study can be used as a basic guidance to understand the importance of achieving accurate control of the fuel cell operating conditions for the robust operation of automotive PEM fuel cell systems.

Chlorophyll Fluorescence Analysis for the Assessment of High Temperature Stress in Citrus During the Coloration Period (엽록소 형광 분석을 활용한 착색기 감귤의 고온 스트레스 평가)

  • Tae Seon Eom;Seung Yeon Jang;Ye Bin Hwang;Sung Yung Yoo;Sung Ku Kang;Ji Su Park;Tae Wan Kim
    • Journal of Environmental Science International
    • /
    • v.33 no.9
    • /
    • pp.613-623
    • /
    • 2024
  • This study was conducted in the greenhouse of the Citrus Research Institute of the Rural Development Administration with the aim of analyzing electron transfer efficiency in citrus under high temperatures caused by climate change and selecting photophysiological indicators to identify high temperature resistant varieties. The "Shiranuhi" cultivar showed no change in maximum fluorescence or Origin-Jump transition stage due to the heat treatment. However, chlorophyll fluorescence parameters, such as RC/CS, ABS/CS, and ETo/CS, increased. Consequently, it was judged that there was no decrease in photosynthetic performance due to high temperature. However, compared to mandarin orange, "unshiu Marcow" was found to have damage to the photosynthetic apparatus due to a significant increase in chlorophyll fluorescence in the O-J transition stage. It was also evaluated as Group III, with the lowest level of high-temperature resistance even in the high-temperature stress index analysis using PI ABS, making it the most vulnerable to high temperatures among the five varieties tested. In conclusion, chlorophyll fluorescence reaction analysis can be used for heat cultivation technology by selecting resistant varieties and identifying the appropriate temperatures.

A Study on the Safety Improvement in Incineration System from the Case Study of Acrylic acid manufacturing process Accident (아크릴산 제조공정 사고사례를 통한 소각 시스템의 안전성 향상 방안)

  • Ma, Byung-Chol;Lee, Keun-Won;Im, Ji-Pyo;Kim, Young-Chul
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.4
    • /
    • pp.52-58
    • /
    • 2012
  • Recently, waste gas incineration is increasing due to strong environmental regulatory system in Korea. These incinerating facilities are usually connected with the top of the storage tank through pipeline and incinerate off gas with the flame. Therefore, the flame originated from these facilities is likely to move back into pipeline and might cause an explosion of the storage tank. Accordingly, the purpose of this study is to suggest the preventive measures and the way to improve the safety of these incineration systems through the cause analysis of a major industrial accident occurred in a acrylic acid manufacturing process in Korea. As a result of the study, the preventive measures are suggested as follows. (1) Air or inert gas inflow facilities should be well designed to dilute flammable gases into air or inert gas sufficiently before the blower is restarted in order to prevent the explosion (2) It is needed for the detonation-type flame arresters to be installed on the top of the storage tanks. (3) In case of using the deflagration-type flame arresters, it is necessary to install a rupture disk before the arresters, or blow off the flame outside tanks by connecting the tank top and the incinerator with hood-type pipe. (4) TDR should be installed to be restarted automatically after the momentary power failure.

Tracer Experiment for the Investigation of Urban Scale Dispersion of Air Pollutants - An Improved Method for the Release and Determination of Perfluorocarbon Tracers in the Urban Atmosphere (추적자 확산 실험에 의한 서울 도심 확산 현상 연구 - 도시규모 대기확산 실험을 위한 PFCs 추적자 방출 및 분석 시스템의 개발 및 적용 연구)

  • Yoo, Eun-Jin;Lee, Chong-Bum;Ro, Chul-Un;Kim, Hye-Kyeong;Lee, Gang-Woong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.5
    • /
    • pp.547-556
    • /
    • 2007
  • The release, sampling and analytical methods have been developed and tested for perfluorocarbons (PFCs) atmospheric tracers in order to gain insight into the atmospheric transport and dispersion over the urban conditions of Seoul, Korea. Although PFCs tracer experiments provide unique opportunities to test local and urban scale of transport and dispersion, no previous experiment with PFCs has been conducted in Korea. PMCH and PDCH were chosen as targeted tracers in our study due to their extreme low ambient concentrations and great sensitivities among various PFCs. For PFCs release system, a set of micro-metering pump, electronic balance, vaporizing furnace and high speed blower was constructed for precise and accurate release of tracers. The precision of released rate by this system was estimated to be 1%. Samplings of PFCs were carried out by fabricated portable air samplers with micro pumps and rotameters into glass tubes packed with 150 mg of Carboxen-569. The uncertainty of these sampling system was maintained below 14%. PMCH and PDCH were quantified in GC/ECD with preconditioned injection system to eliminate the interference compounds using traps and subsequent catalytic conversion system prior to column separation. Three intensive field test were undertaken during the springtime of 2002 to 2004 in eastern part of Seoul. Daily background samples were collected to characterize the background levels of PMCH and PDCH prior to their release. The observed background concentrations of PMCH ranged from 3.5 to 10.1 fL/L and varied randomly in location and time in this study. Its mean and standard variation of background concentration ($6.8{\pm}1.9\;fL/L$) are higher than those ($3.2{\sim}5.8\;fL/L$) of other historic tracer studies. Identified uncertainty for background PMCH was $1.7{\sim}2.0\;fL/L$ using this analytical system. Combined relative uncertainty in determining the tracer's concentrations was estimated as 17%. However, its background concentrations and uncertainty in concentration determination were found to be low and stable enough for tracer study.

Thermal Flow Characteristics of a Hybrid Plant Factory with Multi-layer Cultivation Shelves (다층 재배선반을 갖는 하이브리드 식물공장의 열유동 특성)

  • Yoon, Ji-Hwan;Ryu, Bong-Jo;Kim, Youngshik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.11
    • /
    • pp.7990-8000
    • /
    • 2015
  • Plant factories are plant cultivation systems which produce farm products uniformly under the controlled environmental condition regardless of seasons and places. Thermal flow in the plant factory is an important parameter in cultivating plants. In this research, we study thermal flow characteristics for a hybrid plant factory with multi-layer cultivation shelves using computer simulation techniques. In order to obtain numerical solutions for thermal flow characteristics, a finite volume method was applied. We consider a low-Reynolds-number ${\kappa}-{\epsilon}$ turbulence model, incompressible viscous flows, and pressure boundary conditions for numerical simulation. Commercial software Solid Works Flow Simulation is then used to investigate characteristics of thermal flows in the plant factory applying several different inflow air velocities and arrangements of cultivation shelves. From numerical analysis results, we found that temperatures in cultivation shelves were uniformly distributed for Case 3 when the inflow air velocity was 1.6 m/s by using a blower in the plant factory. However in Case 1 lower temperature distributions were observed in test beds, TB2 and TB3, which indicated that additional temperature control efforts would be required. Average shelf temperature increased by $3^{\circ}C$ using artificial light source (DYLED47) with 50% blue and 50% red LED ratios. Korea Academia-Industrial cooperation Society.

Stabilizing Soil Moisture and Indoor Air Quality Purification in a Wall-typed Botanical Biofiltration System Controlled by Humidifying Cycle (가습 주기에 따른 벽면형 식물바이오필터의 토양 수분 안정화 및 실내공기질 정화)

  • Lee, Chang Hee;Choi, Bom;Chun, Man Young
    • Horticultural Science & Technology
    • /
    • v.33 no.4
    • /
    • pp.605-617
    • /
    • 2015
  • The ultimate goal of this research is to develop a botanical biofiltration system that combines a green interior, biofiltering, and automatic irrigation to purify indoor air pollutants according to indoor space and the size of biofilter. This study was performed to compare the stability of air flow characteristics and removal efficiency (RE) of fine dust within a wall-typed (vertical) botanical biofilter depending on humidifying cycle and to investigate RE of volatile organic compounds (VOCs) by the biofilter. The biofilter used in this experiment was designed as an integral form of water metering pump, water tank, blower, humidifier, and multi-level planting space in order to be suitable for indoor space utilization. As a result, relative humidity, air temperature, and soil moisture content (SMC) within the biofilter showed stable values regardless of three different humidifying cycles operated by the metering pump. In particular, SMCs were consistently maintained in the range of 27.1-29.7% during all humidifying cycles; moreover, a humidifying cycle of operating for 15 min and pausing for 45 min showed the best horizontal linear regression (y = 0.0008x + 29.09) on SMC ($29.0{\pm}0.2%$) during 120 hour. REs for number of fine dust (PM10) and ultra-fine dust (PM2.5) particles passed through the biofilter were in the range of 82.7-89.7% and 65.4-73.0%, respectively. RE for weight of PM10 passed through the biofilter was in the range of 58.1-78.9%, depending on humidifying cycle. REs of xylene, ethyl benzene, total VOCs (TVOCs), and toluene passed through the biofilter were in the range of 71.3-75.5%, while REs of benzene and formaldehyde (HCHO) passed through the biofilter were 39.7% and 44.9%, respectively. Hence, it was confirmed that the wall-typed botanical biofilter suitable for indoor plants was very effective for indoor air purification.