• 제목/요약/키워드: air supply system

검색결과 880건 처리시간 0.024초

교환기실의 급배기방식에 따른 통신 시스템의 냉각 특성 (Cooling characteristics of the telecommunication system in a switching room for various air supply and return flow system)

  • 노홍구;이재헌;고철균
    • 설비공학논문집
    • /
    • 제11권5호
    • /
    • pp.669-683
    • /
    • 1999
  • Heat dissipation in the domestic switching room has been gradually increased. Therefore, numerical study on the cooling characteristics of the telecommunication system in a switching room for three kinds of the air supply and return flow system was investigated to develop effective flow system. As a result, the cooling performance of the under floor air supply and overhead return flow system was the best.

  • PDF

급배기 위치에 따른 바닥급기 공조시스템의 냉방 열환경 (Thermal Comfort of the Floor Supply Air Conditioning System for Different Supply-return Locations during Cooling)

  • 김요셉;김영일;유호선
    • 설비공학논문집
    • /
    • 제12권5호
    • /
    • pp.476-485
    • /
    • 2000
  • This study numerically investigates thermal comfort in a space cooled by the floor-supply air conditioning system, in which three different supply-return locations, one floor supply-ceiling return and two floor supply-floor returns, are treated. A complementary experiment is peformed to validate the present numerical analysis, and the prediction agrees favorably with the measured data. In the numerical procedure, a simplified model mimicking the inlet flow through the diffuser is developed for efficient simulations. The calculated results show that the ceiling return type is far better in thermal comfort than the floor return ones within the extent of this study, which seems to be caused by effective vertical penetration of the supply air against natural convection. It is also revealed that the arrangement of port locations in the floor supply-floor return system has insignificant effect on the cooling performance. For selecting a proper system, other characteristics including the heating performance should be accounted for simultaneously with the present estimation.

  • PDF

Thermal Characteristics of a Partition Supply System

  • Jeong, Ky-Bum
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권2호
    • /
    • pp.67-72
    • /
    • 2003
  • A partition integrated air supply system can provide highly personalized environmental control. The supply air is brought up through raised floors and supplied to outlets located on the partition panels. The purpose of this paper is to find out the best design of outlets for optimal occupant comfort within a personal task area. Real scale experiments were conducted to allow for comparisons of outlet designs within a personal task area. Experimental results indicate that the location of an outlet is the most critical factor in improving the efficiency of supply air distribution of a personal task area. Thermal characteristic comparisons were made between the under-floor and the partition supply systems. Experimental results suggest that the partition supply system is more efficient than the under-floor supply system in terms of cooling. Such a system allows occupants to personally control their immediate environment, resulting in higher productivity.

공동주택 적용을 위한 다분기챔버 환기 시스템의 성능평가에 관한 연구 (Performance Evaluation of Multidrop Chamber Ventilation System in Apartment)

  • 김성수;손장열
    • KIEAE Journal
    • /
    • 제9권4호
    • /
    • pp.17-22
    • /
    • 2009
  • It is common to design the duct branches where to supply the required air flow for individual room in residential apartment house. However it is difficult to adjust the air volume adequately in small air duct branches in residential ventilation system. The purpose of this study is to figure out the performance of Multidrop chamber coupling system for the residential ventilation system. The experiments were designed to simulate apartment of $84m^2$ and established multidrop chamber duct and general duct on the ceiling of the apartment. Distribution performance of air supply rate were evaluated in this experiments. As a result, distribution performance of air supply rate in the general duct is different from designed air supply rate by about 35% ~ 50% and about 10% in the multidrop chamber system. In additional the sound insulation performance of the multidrop chamber system decreased about 20% compared with general duct system. Therefore, the multidrop chamber system is considered to satisfy proper air supply rate of each room and to improve the sound insulation performance in apartment Houses.

사무실 공간의 냉방시 천장 및 바닥 급기 공조 방식에 따른 열환경 평가 실험 (Experimental Analysis of Thermal Comfort of an Office Space for Ceiling and Floor Supply Air Conditioning Systems)

  • 조용;권혁승;김성현;김영일
    • 설비공학논문집
    • /
    • 제12권9호
    • /
    • pp.810-816
    • /
    • 2000
  • Thermal comfort plays an important role in modern office buildings. Four major factors affecting thermal comfort are air temperature, velocity, humidity and radiation temperature. Distribution of these thermal factors in indoor space depends largely on the air flow which is related to the method of supplying and extracting air. In this study, an experimental analysis on indoor thermal comfort is conducted to study the difference between a ceiling supply cooling system and a floor supply one. The two cooling systems are applied to an office space during summer season and the distributions of temperature, velocity, radiation temperature and PMV are measured. Results show that the floor supply cooling system is superior in terms of thermal comfort and energy saving. Studies need to be done, however, to reduce the vertical temperature difference of a floor supply air conditioning system.

  • PDF

고분자 전해질 연료전지 시스템의 효율향상을 위한 공기공급 최적화 (Optimization of Air Supply for Increased Polymer Electrolyte Fuel Cell System Efficiency)

  • 주건엽;조기춘;선우명호;최서호
    • 한국자동차공학회논문집
    • /
    • 제19권3호
    • /
    • pp.44-51
    • /
    • 2011
  • Polymer Electrolyte Fuel Cells (PEFCs) operate in wide-range changes in temperature, humidity, and electric current for automotive applications. In order to operate automotive PEFC efficiently, optimal air supply is required to adjust to these changes. This paper presents an air-supply optimization process that consists of experiments, modeling of the PEFC system, and optimization. The objective is to establish an air supply suitable for the required power for PEFC system and optimized with a Lagrange multiplier. Our simplified PEFC system model is used as a constraint for optimization problem. The result of this paper presents that efficient operation of PEFC system can be achieved by air-supply optimization.

Analysis of Supply Airflow Control by a Stratified Thermal Model in a VAV System

  • Kim, Seo-Young;Moon, Jeong-Woo;Cho, Hyung-Hee
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권3호
    • /
    • pp.46-56
    • /
    • 2001
  • The present study concerns the numerical simulation of a supply airflow control in a variable air volume (VAY) system. A stratified thermal model (multi-zone model) is suggested to predict a local thermal response of an air-conditioned space. The effects of various thermal parameters such as the cooling system capacity, the thermal mass of an air-conditioned space, the time delay of thermal effect, and the building envelope heat transmission are investigated. Further, the influence of control parameters such as the supply air temperature, the PI control factor and the thermostat location on a VAV system is quantitatively delineated. The results obtained show that the previous homogeneous lumped thermal model (single zone model) may overestimate the time taken to the set point temperature. It is also found that there exist the appropriate ranges of the control parameters for the optimal airflow control of the VAV system.

  • PDF

초음속 지상추진시험설비의 공기 혼합시스템 설계 및 제작 (Design and Manufacture of the air mixing system for supersonic ground test facility)

  • 이양지;강상훈;양수석
    • 항공우주기술
    • /
    • 제7권1호
    • /
    • pp.40-48
    • /
    • 2008
  • 공기 혼합시스템은 초음속 지상추진시험설비의 축열식 가열기로부터 공급되는 $1000^{\circ}C$, 3.5MPa의 공기와 고압공기 공급원으로부터 공급되는 상온, 동일 압력의 공기를 혼합시켜서 시험부로 공급하기 위한 설비로 32MPa로 압축되어 있는 고압공기 공급원을 3.5MPa로 감압하는 고압/저온 유동제어부, 축열식 가열기의 고온밸브에서부터 공기 혼합기로 고온의 공기를 공급하기 위한 고온 배관, 축열식 가열기로부터 공급되는 고온 유동과 고압공기 공급원으로부터 공급되는 상온 유동을 혼합하기 위한 공기 혼합기로 구성된다. 공기 혼합 시스템을 통하여 완전히 혼합된 공기의 유량은 25kg/s, 온도는 약 $400^{\circ}C$로 이를 통하여 초음속 지상추진시험설비의 구동 영역을 저 마하수, 저 고도 영역까지 확장할 수 있다.

  • PDF

Effect of Supply and Return Locations of a Floor-Supply Cooling System on Thermal Comfort

  • Kim, Young-Il;Kim, Jo-Seph;Yoo, Ho-Seon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권4호
    • /
    • pp.37-46
    • /
    • 2001
  • This study numerically investigates thermal comfort of a space cooled by a floor-supply air-conditioning system, in which three different combinations of supply and return locations, one floor-supply/ceiling-return and two floor-supply/floor-return, are treated. A complementary experiment is performed to validate the present numerical analysis, and the prediction agrees favorably with the measured data. In the numerical procedure, a simplified model mimicking the inlet flow through a diffuser is developed for efficient simulations. The calculated results show that the ceiling-return type is far better in terms of thermal comfort than the floor-return ones within the extent of this study, which seems to be caused by effective vertical penetration of the supply air against natural convection. It is also revealed that the arrangement of port locations in the floor-supply/floor-return system has insignificant effect on the cooling performance. For selecting a proper system, other characteristics including the heating performance should be accounted for simultaneously with the present considerations.

  • PDF

실내 급.배기구 위치변화에 따른 실 공기유동에 관한 연구 (A Study on the Indoor Airflow Pattern by Changing the Location of Mechanical Terminal Unit)

  • 최정민;조성우
    • 설비공학논문집
    • /
    • 제21권3호
    • /
    • pp.193-200
    • /
    • 2009
  • The ventilation system of apartments can be divided by supply and exhaust fan, supply fan and exhaust free and supply free and exhaust fan. Recently, the individual ventilation system and central ventilation system which is combined cooling system with duct system are applied to apartment ventilation system. The airflow pattern is affected by location of supply unit and exhaust unit in indoor. This study is to investigate the proper distance between supply unit and exhaust unit using CFD. As a result of this study, the proper distance between supply unit and exhaust unit could be suggested at the interval of 3 m in supply and exhaust fan system and 2.5 m in supply fan and exhaust free.