• Title/Summary/Keyword: air respiration

Search Result 185, Processing Time 0.028 seconds

Criterion for Operation of Fans to Reduce Heat Stress of Hanwoo (한우의 더위 스트레스를 경감하기 위한 송풍팬의 가동 기준)

  • Lee, Seung-Joo;Gutierrez, Winson M.;Chang, Hong-Hee
    • Journal of agriculture & life science
    • /
    • v.46 no.2
    • /
    • pp.101-106
    • /
    • 2012
  • Fans have been used to reduce heat stress of Hanwoo in summer, but a criterion to determine to operate or not operate them has not been developed yet. Therefore, this study was carried out to establish a criterion of fan operation to reduce heat stress of Hanwoo in summer. Respiration rate of Hanwoo, air temperature, wind speed and relative humidity were collected from Hanwoo farms in summer, 2010 and these data were used to analyze relationship between respiration rate and air temperature, relationship between respiration rate and wind speed, and relationship between respiration rate and relative humidity and so on. The results of this study that air temperature when is over $23^{\circ}C$ and wind speed is below 0.8 m/s affected the respiration rate of Hanwoo. On the other hand, relative humidity did not affect the respiration rate when is below 60%. The results of this study recommend that fans should be operated to reduce the heat stress of Hanwoo, when only air temperature in farm is over $23^{\circ}C$.

Design of Unconstrained Baby Monitoring System Based on a Doppler Radar and an Air Mattress (도플러 레이더와 에어 매트리스를 이용한 무구속 방식의 신생아 감시 장치 설계)

  • Yang, Seong-Soo;Cho, Sung-Pil;Park, Ho-Dong;Lee, Kyoung-Joung
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.6
    • /
    • pp.177-184
    • /
    • 2014
  • Continuous monitoring of heart rates and respiratory rates for newborns or infants is very important since the abnormal breathing and heart problems can threaten the life of newborns or infants. A noncontact baby monitoring system based on a Doppler radar and an air mattress was designed. The Doppler radar was used to acquire respiratory signals and the air mattress was employed to obtain heart rates. The performance of the designed system was evaluated using a commercialized infant simulator ($Simbaby^{TM}$) and a respiration belt transducer was used to measure respiration rates as a reference. Results for respiratory rates revealed that the correlation coefficients between I-and Q-channel and the respiration belt were 0.84 and 0.91 and the mean ${\pm}$ standard deviations of errors between them were $1.66{\pm}1.92$ (bpm) and $0.88{\pm}1.65$ (bpm). Heart rates showed that the correlation coefficient between air mattress and set value of the simulator was 0.73 and the mean ${\pm}$ standard deviation of errors between them was $1.09{\pm}3.45$ (bpm). These results indicate that the designed system holds the potential as an effective monitoring tool for continuous monitoring heart rates and respiratory rates of newborns or infants.

An Implementation of Mobile Respiration Detection Diagnostic System Using Ultrasound Sensing Method (초음파 센싱 방식의 이동형 호흡 측정 진단 시스템의 구현)

  • 김동학;김영길;정승호
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.514-517
    • /
    • 2003
  • Oxygen supply is one of the most basic things in human body. Breathing is controlled by the lungs' stationary function and the respiratory center which is in the mesulla oblongata. Nothing but, the external breathing that air movement between the lungs and atmosphere and the internal breathing that cellular air movement between the hemoglobin and a single cell. The adult's number of times of the respirations is about 15∼20 per 1 minute, but it depends ages, exercise, temperature, disease, etc. The important thing in detecting the respiration is that doing it in object person's resting time. Detecting the respiration have to be done without attracting any attention of object person. In present using method is detecting the pulse with catching an object person's wrist and observing the object person's movement. In this paper, we propose the mobile respiration detection diagnostic system using ultrasound sensing method that does not be influenced by the inertia error and the pressure error.

  • PDF

Development of Novel Assistive Device for Improving Usability of BVM (인공호흡기 사용성 향상을 위한 새로운 보조기구 개발)

  • Jeon, Gang-Hyun;Park, Yong-Jai
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.420-426
    • /
    • 2020
  • In this study, an assistive device for BVM (Bag Valve Mask) was developed. When emergencies occur, rescuers must perform artificial respiration within four minutes utilizing suitable BVM. If not, the patient can suffer serious damage within their brain and body systems. The rescuer must execute artificial respiration until the patient arrives at the hospital. In the process of artificial respiration, the rescuer can feel fatigued in their forearm muscles, particularly those who may have smaller hands or weaker muscle strength. Many products have been developed to solve these problems, but these products are difficult to market and commercialize because of their volume, size, and difficulty of use. In this paper, the BVM assistive device that has been previously manufactured was improved, and an attempt was made to devise a new method that reduces the burden on the user. The BVM assistive device can be divided into three-parts: a head part for compressing the air bag, which can control the amount of air; the body part for coupling with BVM; and finally, the handle that can rotate for better use on various postures of patients. Throughout the experiment, the assistive device could inject an equal amount of air into the patients. As a result, the rescuer could feel less fatigue and inject a suitable amount of air to emergency patients during artificial respiration.

Soil Respiration in Pinus rigida and Larix leptolepis Plantations (리기다소나무와 낙엽송(落葉松) 인공조림지내(人工造林地內) 토양발생(土壤發生) 이산화탄소(二酸化炭素)에 관한 연구(硏究))

  • Son, Yowhan;Kim, Hyun-Woo
    • Journal of Korean Society of Forest Science
    • /
    • v.85 no.3
    • /
    • pp.496-505
    • /
    • 1996
  • Soil respiration was measured every two weeks from May through November 1995 using the soda lime method in 40-Year-old Pinus rigida and Larix leptolepis plantations on a similar soil in Yangpyeong, Kyonggi Province. Treatments included control and no-roots(plots trenched and root regrowth into plots prevented). Root respiration was evaluated by comparing no-roots sub-plots to control plots. Mean soil respiration showed highly significant species effects(p<0.01) and was highest at the Pinus rigida control plot($0.38g/m^2/hr$) and lowest at the Larix leptolepis no-roots plot($0.31g/m^2/hr$). High soil respiration in Pinus rigida may be related to aboveground litter production. The annual $CO_2$ fluxes ranged from 23 to 27t/ha/yr. We found significant correlations between temperatures(air : $R^2$=0.53, soil : $R^2$=0.55) and soil respiration(p<0.01), but no significant correlations between soil moisture and soil respiration(p>0.1). Root respiration was 3% of total soil respiration. We might underestimate rapt respiration because of shallow trenches and $CO_2$measurements right after trenching. Factors controlling soil respiration including belowground litterfall(especially fine roots) inputs, litter quality should be well understood to predict soil carbon fluxes and relative contributions to total soil respiration in forest ecosystems.

  • PDF

Development of a Classification Model for Driver's Drowsiness and Waking Status Using Heart Rate Variability and Respiratory Features

  • Kim, Sungho;Choi, Booyong;Cho, Taehwan;Lee, Yongkyun;Koo, Hyojin;Kim, Dongsoo
    • Journal of the Ergonomics Society of Korea
    • /
    • v.35 no.5
    • /
    • pp.371-381
    • /
    • 2016
  • Objective:This study aims to evaluate the features of heart rate variability (HRV) and respiratory signals as indices for a driver's drowsiness and waking status in order to develop the classification model for a driver's drowsiness and waking status using those features. Background: Driver's drowsiness is one of the major causal factors for traffic accidents. This study hypothesized that the application of combined bio-signals to monitor the alertness level of drivers would improve the effectiveness of the classification techniques of driver's drowsiness. Method: The features of three heart rate variability (HRV) measurements including low frequency (LF), high frequency (HF), and LF/HF ratio and two respiratory measurements including peak and rate were acquired by the monotonous car driving simulation experiments using the photoplethysmogram (PPG) and respiration sensors. The experiments were repeated a total of 50 times on five healthy male participants in their 20s to 50s. The classification model was developed by selecting the optimal measurements, applying a binary logistic regression method and performing 3-fold cross validation. Results: The power of LF, HF, and LF/HF ratio, and the respiration peak of drowsiness status were reduced by 38%, 22%, 31%, and 7%, compared to those of waking status, while respiration rate was increased by 3%. The classification sensitivity of the model using both HRV and respiratory features (91.4%) was improved, compared to that of the model using only HRV feature (89.8%) and that using only respiratory feature (83.6%). Conclusion: This study suggests that the classification of driver's drowsiness and waking status may be improved by utilizing a combination of HRV and respiratory features. Application: The results of this study can be applied to the development of driver's drowsiness prevention systems.

The Change of Quality of Fresh Shiitake (Lentinus edodes) in Storage under Controlled Atmosphere Conditions

  • Pujantoro, Lilik;Tohru, Shiga;Kenmoku, Akitsugu
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.423-432
    • /
    • 1993
  • The changes of quality of Fresh Shiitake (Lentinus edodes) was studied in this research work by investigating the effect of low $O_2$ content and high $CO_2$ content, well known as CA Treatment in storage, on the respiration rate and PPO Activity that was the main factor in Shiitake quality decay. CA Condition was conducted in 3 research periods that combined the $O_2$content(1%, 5% and 10%) and $CO_2$ content (5%, 10%, 15% and 20%) and air treatment as the control. The lower $O_2$content was the lower respiration rte that was showed in combination the lower respiration rate that was showed in combination of 20% $CO_2$ and 1% $O_2$ (the lowest), and the control air treatment was the highest . Very low $O_2$ content, conversly, did not show a satisfying result to the product.

  • PDF

Studies on the Heat Transfer Characteristics of Citrus Fruits (I) On the Cooling Process of Packed Bed of Citrus Unshu (감귤의 열전달 특성에 관한 연구 - (I) 온주밀감충전층의 냉각과정에 대하여 -)

  • Hur Jong-Wha;Kim Suk-Hyun
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.7 no.2
    • /
    • pp.80-86
    • /
    • 1978
  • The distribution of temperature obtained by the solution of Schumann equation and that of experimentally obtained on tile cooling process of packed bed of citrus unshu show a good agreement, and the maximum deviation is only $1-2^{\circ}C$. The agreement means that it is possible to apply the Schumann model to the cooling process of packed bed of citrus unshu. In considering respiration heat, the numberical result by the solution of the equation is that in case of the velocity of gas $(3^{\circ}C)$ is above 1m/sec, becomes below 0.01 and effect of respiration heat is negligible and in case of below 1m/sec the velocity of gas $(3^{\circ}C)$ is above 0.01 and the effect of respiration heat must be consideied. We Present the Practically easily applicable figure of cooling characteristic line on the both . cases of short term cooling Process and long time storage of citrus unshu.

  • PDF

Development of Sleep-disordered Breathing Detection System using Air-mattress and Pulse Oximeter (에어 매트리스와 산소 포화도 측정기를 이용한 수면호흡장애 자동 검출 시스템 개발)

  • Jeong, Pil-Soo;Park, Jong-Uk;Joo, Eun-Youn;Lee, Kyoung-Joung
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.4
    • /
    • pp.153-162
    • /
    • 2017
  • The present study proposes a system that can detect sleep-disordered breathing automatically using an air mattress and oxygen saturation. A thin air mattress was fabricated to reduce discomfort during sleep, and respiration signals were acquired. The system was configured to be synchronized with a polysomnography to receive signals simultaneously with other bio-signals. The present study has been conducted with nine adult male and female patients with sleep-disordered breathing, and sleep-disordered breathing events have been detected by applying the signals acquired from the subjects to the rule-based detection algorithm. The sensitivity and positive predictive values were found to evaluate the performance of the system, which are 91.4% and 89.7% for all events, respectively. The comparison of apnea hypopnea index(AHI) between the polysomnography and the proposed method showed squared R-value of 0.9. This study presents the possibility of detecting sleep-disordered breathing at hospitals or homes using the proposed system.

The Effect of Air Injection Quantity on Stabilization of Screened Soil in Aerobic Bioreactor Landfill (호기성 Bioreactor 매립지에 있어서 공기주입량이 선별토사의 안정화에 미치는 영향)

  • Park, Jin-Kyu;Lee, Nam-Hoon;Kim, Nack-Joo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.12 no.1
    • /
    • pp.104-109
    • /
    • 2004
  • In this study, we stabilized the screened soil from landfills by using aerobic bioreactor and evaluated aerobic decomposition of it. Four lab-scale bioreactors (anaerobic and 1 PV/day aeration, 5 PV/day aeration, 10 PV/day aeration) filled with screened soil were operated to investigate the effect of air injection quantity on stabilization of screened soil. In case of aerobic bioreactors, the decomposition of organics in screened soil was higher than anaerobic bioreactor. According to the results of landfill gas and soil respiration test, the air injection quantity of 5 PV/day was most efficient in stabilization of screened soil.

  • PDF