• Title/Summary/Keyword: air replacement

Search Result 345, Processing Time 0.021 seconds

Bivalvation Valvuloplasty for Common Atrioventricular Valve Regurgitation in Functional Single Ventricle; Early and Mid-term Results (기능적 단심설에서 공통방실판 역류의 판막성형술; 판막 이분성형술(bivalvation)의 조기 및 중기 결과)

  • Chang, Yun-Hee;Sung, Si-Chan;Kim, Seon-Hee;Lee, Hyoung-Doo;Ban, Ji-Eun
    • Journal of Chest Surgery
    • /
    • v.42 no.5
    • /
    • pp.597-603
    • /
    • 2009
  • Background: Atrioventricular valve regurgitation in pediatric patients with a functional single ventricles (FSV) - has been known as one of the important risk factors for death and unfavorable long-term results after a Fontan operation. We evaluated early and mid-term results of bivalvation valvuloplasty in FSV patients. Material and Method: We retrospectively evaluated 11 patients with a functional single ventricle who underwent bivalvationvalvuloplasty between 1999 and 2007. The degree of common atrioventricular valve regurgitation (CAVVR) was determined by color Doppler echocardiography (regurgitation grade scoring, trivial; 1, mild; 2, moderate; 3, severe; 4). Mean age at valve surgery was $6.9{\pm}7.0$ months (median 4 months, 24 days$\sim$21 months)and mean body weight was $6.2{\pm}2.8\;kg$ ($3.1{\sim}11.3\;kg$). Nine patients had isomerism heart and two of them had TAPVC. The concomitant procedures were performed in all but one patient. Additional commissural closure was performed in 3 patients and commissural annuloplasty in another 3 patients. Result: There was one hospital death after. surgery. A 32-day old patient who had been preoperatively dependent on a ventilator died of air way and lung problems 4.3 months after pulmonary artery banding and bivalvation valvuloplasty. Mean follow-up duration was 40 months ($4.3{\sim}114$ months). Mean preoperative CAVVR score was $3.3{\pm}0.6$, which decreased to $1.9{\pm}0.7$ postoperatively (p<0.0001). This residual regurgitation slightly increased to $2.2{\pm}0.4$ (no statistical significance) after a mean follow-up of 1.4.3 months. Six patients (60%) required re-operations for residual regurgitation at a subsequent bidirectionalcavopulmonary shunt or Fontan operation. One patient with Ebsteinoid malformation of the right sided atrioventricular valve required valve replacement due to stenoinsufficiency. Another patient required edge-to-edge repair at the right sided AV valve (between the right mural leaflet and the bridging leaflets). The remaining 4 patients required additional suture placements between bridging leaflets with or without commissural annuloplasty. All survivor had trivial or mild CAVVR at the latest follow-up. Conclusion: Bivalvation valvuloplasty for CAVVR in FSV patients is. an effective and safe procedure. However, significant numbers of the patients have small residual regurgitation and require additional valve procedures at subsequent operations. Long-term observations to monitor progression of the CAVVR is mandatory.

Study on Amenity and Economical Efficiency of Multi-functionality on the Grassland (초지형 축산의 어메니티 및 경제성 평가에 관한 연구)

  • Cheon, D.W.;Lee, S.Y.;Park, M.S.;Park, H.S.;Hwang, K.J.;Yun, S.H.;Ko, M.S.
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.27 no.4
    • /
    • pp.297-312
    • /
    • 2007
  • This study is conducted to evaluate economical value of Jeju grassland and validity of its preservation, and draw up several measures to support. To measure its economical value, this study examined its environmental value and social and cultural value. For environmental value, this study used replacement method while it applied CVM method, a widely used method, to assess social and cultural value and two-level two-best choice selection method, which ask questions by assuming virtual circumstances to avoid reflecting some biased opinions. Jeju grassland has multiple functions-environmental functions such as preventing soil corrosion and flood, handling animal excrement, and purifying air, and social and cultural functions such as promoting physical and mental health and providing recreation places. From the results of the feasibility study, Jeju grassland's annual multiple functions are assessed to have a total $397,115{\sim}418,995$ million won worth. In addition, it is found that Jeju visitors recognize Jeju grassland for its functions to contribute to public interests. That is, they think it can provide attractive views and educational and recreational places and promote emotional development. Especially, many people presented their ideas that it be continuously preserved since it is worthwhile for us and our next generations. To preserve grassland's cultural resource, which create a huge economic value like this, the Government has to support a certain amount of financial aid for turning to a better grassland environment and its maintenance to realize environment-friendly livestock farming on Jeju Island and promote its tourism industry and consequently, add more value to Jeju.

Preliminary Report of Observed Urban - Rural Gradient of Carbon Dioxide Concentration across Seoul, Suwon, and Icheon in South Korea (도시 - 전원간 이산화탄소(CO2) 농도구배 예비관측 결과)

  • Chung, U-Ran;Lee, Kyu-Jong;Lee, Byun-Woo
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.9 no.4
    • /
    • pp.268-276
    • /
    • 2007
  • Urban atmosphere may play as a harbinger for the future climate change with respect to temperature and $CO_2$ concentration. The Seoul metropolitan area is unique in rapid urbanization and industrialization during the last several decades, providing a natural $CO_2$ dome with increased temperature. This study was carried out to evaluate the feasibility of using the urban-rural environmental gradient in replacement of the IPCC mid-term scenario (after 30-50 years). For this, we measured atmospheric $CO_2$ concentration and air temperature at three sites with different degree of urbanization (Seoul, Suwon, and Icheon). Results from 11-month measurement can be summarized as follows: (1) The annual mean $CO_2$ concentration across 3 sites was in the order of Seoul (439 ppm) > Suwon (419 ppm) > Icheon (416 ppm), showing a substantial urban-rural environmental gradient. (2) The diurnal fluctuation in $CO_2$ concentration was greater in summer than in winter, showing the effect of photosynthesis on local $CO_2$ concentration. (3) The daily maximum $CO_2$ concentration was observed at 0500 LST in spring and summer, 0800 LST in autumn, and 0900 LST in winter, showing the sunrise-time dependence. (4) The observed hourly maximum $CO_2$ concentration averaged for the whole period was 446 ppm in Seoul at 0700 LST, while the minimum was 407 ppm in Suwon at 1500 LST. (5) Compared with the background atmospheric concentration of $CO_2$ in Anmyeon-do (377.4 ppm annual mean), $CO_2$ concentration of the study sites was higher by 14% in Seoul, by 10% in Suwon, and by 9% in Icheon. The observed $CO_2$ concentration in Seoul reached already 98% of the 2030-2040 projection (450 ppm) and 80% of the 2040-2050 projection (550 ppm) under the IPCC BAU scenario, showing a feasibility of using the $CO_2$ dome of Seoul as a natural experimental setting for the mid-term climate change impact assessment.

Recovery of $SF_6$ gas from Gaseous Mixture ($SF_6/N_2/O_2/CF_4$) through Polymeric Membranes (고분자 분리막을 이용한 혼합가스($SF_6/N_2/O_2/CF_4$)로부터 $SF_6$의 회수)

  • Lee, Hyun-Jung;Lee, Min-Woo;Lee, Hyun-Kyung;Choi, Ho-Sang;Lee, Sang-Hyup
    • Membrane Journal
    • /
    • v.21 no.1
    • /
    • pp.22-29
    • /
    • 2011
  • During the maintenance, repair and replacement process of circuit breaker, $SF_6$ reacted with input air in arc discharge, which led to the production of by-product gases (eg, $N_2$, $O_2$, $CF_4$, $SO_2$, $H_2O$, HF, $SOF_2$, $CuF_2$, $WO_3$). Among these various by-product gases, $N_2$, $O_2$, $CF_4$ is major component. Therefore, the effective separation process is necessary to recycle the $SF_6$ gas from the mixture gas containing $N_2$, $O_2$, $CF_4$. In this study, the membrane separation process was applied to recycle the $SF_6$ gas from the mixture gas containing $N_2$, $O_2$, $CF_4$. The concentration of $SF_6$ gas in gas produced from the electric power industry is over than 90 vol%. Therefore, we made the simulated gas containing $N_2$, $O_2$, $CF_4$, $SF_6$ which the concentration of $SF_6$ gas is minimum 90 vol%. From the results of membrane separation process of $SF_6$ gas from $N_2$, $O_2$, $CF_4$ $SF_6$ mixture gases, PSF membrane shown the highest recovery efficiency 92.7%, in $25^{\circ}C$ and 150 cc/min of retentate flow rate. On the other hand, PC membrane shown the highest recovery efficiency 74.8%, in $45^{\circ}C$ and 150 cc/min of retentate flow rate. Also, the highest rejection rate of $N_2$, $O_2$, $CF_4$ is 80, 74 and 58.9% seperately in the same operation condition of highest recovery efficiency. From the results, we supposed the membrane separation process as the effective $SF_6$ separation and recycle process from the mixture gas containing $N_2$, $O_2$, $CF_4$, $SF_6$.

A Basis Study on the Optimal Design of the Integrated PM/NOx Reduction Device (일체형 PM/NOx 동시저감장치의 최적 설계에 대한 기초 연구)

  • Choe, Su-Jeong;Pham, Van Chien;Lee, Won-Ju;Kim, Jun-Soo;Kim, Jeong-Kuk;Park, Hoyong;Lim, In Gweon;Choi, Jae-Hyuk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.6
    • /
    • pp.1092-1099
    • /
    • 2022
  • Research on exhaust aftertreatment devices to reduce air pollutants and greenhouse gas emissions is being actively conducted. However, in the case of the particulate matters/nitrogen oxides (PM/NOx) simultaneous reduction device for ships, the problem of back pressure on the diesel engine and replacement of the filter carrier is occurring. In this study, for the optimal design of the integrated device that can simultaneously reduce PM/NOx, an appropriate standard was presented by studying the flow inside the device and change in back pressure through the inlet/outlet pressure. Ansys Fluent was used to apply porous media conditions to a diesel particulate filter (DPF) and selective catalytic reduction (SCR) by setting porosity to 30%, 40%, 50%, 60%, and 70%. In addition, the ef ect on back pressure was analyzed by applying the inlet velocity according to the engine load to 7.4 m/s, 10.3 m/s, 13.1 m/s, and 26.2 m/s as boundary conditions. As a result of a computational fluid dynamics analysis, the rate of change for back pressure by changing the inlet velocity was greater than when inlet temperature was changed, and the maximum rate of change was 27.4 mbar. This was evaluated as a suitable device for ships of 1800kW because the back pressure in all boundary conditions did not exceed the classification standard of 68mbar.