• Title/Summary/Keyword: air quality database

Search Result 44, Processing Time 0.024 seconds

Methodology of Application to Air Quality Model to Evaluate the Results of the Enforcement Plan in Seoul Metropolitan Area (수도권 지역의 대기환경관리 시행계획 추진결과 평가를 위한 대기질 모델링 적용 방법)

  • Yoo, Chul;Lee, Dae-Gyun;Lee, Yong-Mi;Lee, Mi-Hyang;Hong, Ji-Hyung;Lee, Seok-Jo
    • Journal of Environmental Science International
    • /
    • v.20 no.12
    • /
    • pp.1647-1661
    • /
    • 2011
  • The Government had devised legislation of Special Act and drew up guidelines for improving air quality in Seoul Metropolitan area. In 2007 local government of Seoul, Incheon and Gyeonggi conducted the results of application policy by reduced air pollutants emission for the first time. Although there was reduction of air pollutant emission in each local government, it was ineffective as expected using air pollution monitoring database. Therefore we worked out a way to prepare modeling input data using the results of enforcement plan. And we simulated surface $NO_2$ and PM10 before and after decrease in air pollutants emission and examine reduction effects of air pollution according to enforcement regulation except other influence, by using MM5-SMOKE-CMAQ system. Each local government calculated the amount of emission reduction under application policy, and we developed to prepare input data so as to apply to SMOKE system using emission reduction of enforcement plan. Distribution factor of emission reduction were classified into detailed source and fuel codes using code mapping method in order to allocate the decreased emission. The code mapping method also included a way to allocate spatial distribution by CAPSS distribution. According to predicted result using the reduction of NOx emission, $NO_2$ concentration was decreased from 19.1 ppb to 18.0 ppb in Seoul. In Gyeonggi and Incheon $NO^2$ concentrations were down to 0.65 ppb and 0.68 ppb after application of enforcement plan. PM10 concentration was reduced from 18.2 ${\mu}g/m^3$ to 17.5 ${\mu}g/m^3$ in Seoul. In Gyeonggi PM10 concentration was down to 0.51 ${\mu}g/m^3$ and in Incheon PM10 concentration was decreased about 0.47 ${\mu}g/m^3$ which was the lower concentration than any other cities.

Study to improvement of the interior comfort in the Tilting train (틸팅열차 실내 쾌적성 향상 연구)

  • Kim, Hyun-Shik;Jang, Chang-Yun;Jang, Jae-Seung
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1243-1248
    • /
    • 2009
  • This paper introduces the methode to improve the indoor air quality for Korea Tilting train express(TTX). TTX operates more than 80,000km in commercial line and in the near future service is expected. To improve air quality effective heat and cooling system is proposed. Also according to the ministry of environment guide line, major factor component are selected to Co2(carbon dioxide) and Pm10(particle matter). The database of the vital factor was accumulated by the various case of operation environment. Finally, optimal air condition controling device is developed and installed.

  • PDF

GIS-based PM10 Concentration Real-time Service (GIS기반 PM10 미세먼지농도 실시간 서비스)

  • Yoon, Hoon Joo;Han, Gwang In;Cho, Sung Ho;Jung, Byung hyuk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.6
    • /
    • pp.585-592
    • /
    • 2015
  • In this study, by applying mobile based GIS and image analysis of particulate matter ($PM_{10}$) concentration in Seoul and Ulsan in Korea, to identify the user's location and also implemented the application to information exchange. It strengthened citizens' access to air quality information through the application and derived the expanded environment information sharing through real-time user participation. Through atmospheric concentrations image analysis, it showed a new environmental information construction possibility. It had the effect of expanding the information collecting through the local user participation on the limited information collected area which place is not yet constructed atmospheric monitoring network. Location-based particulate matter information service application provides a user location's $PM_{10}$ information from the 25 urban air monitoring network real-time database of the Ministry of Environment. Furthermore, if the user sent a picture of the atmosphere to the server, should match the image density values of the database and express on Seoul's maps through the IDW interpolation. And then a $PM_{10}$ concentration result is transmitted to user in real time.

PM10 and PM2.5 Characterization based on Mass Concentration Long-term (1989 ~ 2012) Database in Yongin-Suwon Area (장기간 (1989 ~ 2012) 측정자료를 이용한 용인-수원지역에서의 PM10 및 PM2.5의 오염특성 분석 (질량농도 중심))

  • Lim, Hyoji;Lee, Tae-Jung;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.3
    • /
    • pp.209-222
    • /
    • 2015
  • Fine and coarse PM had been collected by LVCI (low volume cascade impactor) and HVAS (high volume air sampler) during January 1989 to April 2012 at Kyung Hee University, Global Campus located on the boarder of Yongin and Suwon. The database of PM mass concentration was constructed and then intensively and extensively investigated to understand monthly, seasonal, and annual patterns of each PM behavior. Especially the study separated all the PM data into the 5 Period Zones, which were classified on the basis of social, political, and environmental issues that might be influencing local ambient air quality during the monitoring period. The overall $PM_{10}$ level had been continuously decreased until 2005 and after then was staggering due to rapidly increasing $PM_{2.5}$ level in $PM_{10}$. The annual average of $PM_{2.5}$ concentration varied from $34.3{\mu}g/m^3$ to $59.0{\mu}g/m^3$, which were much higher than the 2015 ambient air quality standard. The $PM_{2.5}$ level was strongly associated with haze events, while both $PM_{10}$ and $PM_{2.5}$ levels were associated with Yellow storm events. Daily concentrations of $PM_{2.5}$ were ranged $13.1{\sim}212.9{\mu}g/m^3$ in haze days and $33.6{\sim}124.6{\mu}g/m^3$ in Asian dust days. The study also intensively investigated annual and seasonal patterns of $PM_{2.5}/PM_{10}$ ratios.

Development of a building materials database; Volatile organic compounds, formaldehyde emission rates and chemical compositions (건축자재의 오염물질 방출 데이터베이스 개발; 휘발성유기화합물, 폼알데하이드 방출강도 및 화학조성)

  • Yu, Young-Jae;Lee, Chul-Won;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.57-64
    • /
    • 2009
  • A material database has been developed for VOCs and formaldehyde emitted from building materials in this study. New classification system has been made by correlating the classification methods used in Korean Air Cleaning and Environmental Protection Agency. The developed databases include emission rates of TVOC, 5VOC and formaldehyde emitted from each building material. In addition, the databases can be used as an input variable to estimate indoor air quality (IAQ) using computer simulation since they also contain chemical component and general imformation. Box plot was used to do statistical analysis for emission rates of formaldehyde and TVOCs from different types of building materials. Also we confirmed the building materials worsening IAQ by categorizing the emission characteristic of different types of pollutants.

A Study on the Application and Economical Efficiency of Electric Driven Cargo Pumping System (전동기 구동 카고펌프의 적용 및 경제성 연구)

  • Cho, Dong-Ju;Kim, Kyung-Bae;Park, Myung-Kyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.1
    • /
    • pp.85-89
    • /
    • 2012
  • This study has been conducted to compare two cargo handling systems on MR tanker and Panamax tanker. Submerged hydraulic cargo pumps with hydraulic power packs and frequency converter controlled electric deepwell pumps will be investigated and compared on all aspects of initial cost, installation, operation and maintenance. The result of investigation shows Electric Systems have less manufacturing costs, higher environmental friendliness and reliable operation compare to Hydraulic Systems. Furthermore, the present experimental data will provide important database for Electric Systems onboard new ships and practical and empirical guidelines are constructed for further determine the design of the Electric Systems.

A Study on the Environment Planning of Exhibition Space for Conservation of Collection in a Museum (박물관자료의 보존을 위한 전시공간 환경계획에 관한 연구)

  • Jung, Sung-Wook
    • Korean Institute of Interior Design Journal
    • /
    • v.17 no.2
    • /
    • pp.91-101
    • /
    • 2008
  • The purpose of this study is to suggest the design guidelines of exhibition space for conservation of collection in a museum. With the purpose of this study, examined the concept and a condition of conservation which is focused on deterioration in a exhibition space, investigated the actual condition of total 42 facilities and analyzed the specific instance which is excellent by factor of environment plan. Hereupon, the results of this study are as follows. First, exhibition space should be equipped with sufficient 'Filtering Space' before the outdoor and located central territory in a museum facility. Second, exhibition space should be partition off an area into the quality of collection, and then controlled by each of them. Third, in consideration of the annual air fluctuation of our country, the database which is adaptable for setting up the standard of temperature and RH must be prepared. Fourth, it is necessary to establish a 'Reference Exhibition Room' which is formed cellular type and a 'Garnering Exhibition Center'. Fifth, for the prevention of deterioration which is generated in exhibition space, the showcase must be high air-tight. Sixth, it is necessary to reduce a inside space of high air-tight showcase. Seventh, art-sorb is suitable for control the organic matter of collection and a except of fiber optics is not suitable for lighting of showcase. Eighth, wall-type showcase should be have air-chamber which is formed like museum storage and run over 8 hours a day.

Statistical Analysis of PM10 and Meteorological Data in Pohang, a Steel-Industrial City (철강 산업도시 포항의 미세먼지 농도 및 관련 기상자료에 대한 통계적 분석)

  • Choi, Min-Suk;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.3
    • /
    • pp.329-341
    • /
    • 2016
  • Pohang is a well-known industrial city in Korea with a large steel-industrial complexes. The biggest environmental issue in the city is associated with fine particulate matter (hereinafter, $PM_{10}$). The concentration of $PM_{10}$ is generally dependent on the local emission sources and meteorological conditions. Iron and steel industrial complexes are likely serious pollution sources of $PM_{10}$ in Pohang. In this study, daily $PM_{10}$ data from a large database from the year of 2000 to 2012 were statistically analyzed, together with meteorological data. The average concentrations of $PM_{10}$ were evaluated according to the frequency of Asian dust, haze, mist, and fog. The number of days exceeding short-term standard for $PM_{10}$ were also examined, taking into consideration of weather conditions. It was found that the concentration of $PM_{10}$ was reduced about 18% to 26% because of precipitation. In addition, the effects of wind direction and wind speed on the $PM_{10}$ concentrations were investigated.

Implement of Analysis system with Indoor Environment Monitoring Based on IoT (사물인터넷 기반 실내 환경 모니터링 분석 시스템 구현)

  • Nam, Jae-hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.12
    • /
    • pp.1687-1692
    • /
    • 2019
  • In the era of the fourth industrial revolution, advanced technologies such as the Internet of Things(IoT) and big data are emerging. However, the level of application of IoT to indoor environment is very weak. Therefore, it is necessary to develop a system for analyzing air pollutants or indoor air quality through real-time monitoring using the IoT. This paper implements a system that measures indoor environmental values using Arduino and various sensors, and stores the information obtained from various sensors into a database of server. The information stored in the server was built as a database and utilized in the ventilation system or air cleaner installed in the home or company's room. In the proposed system, it is possible to check the immediate indoor environmental condition through the LED status display of the monitoring sensor module while reducing the cost of the sensor used to implement IoT technology.