• Title/Summary/Keyword: air pollutant concentration

Search Result 288, Processing Time 0.027 seconds

Planning of Apartment Units for Improving Natural Ventilation Performance based on the Analysis of Indoor Pollutant Concentrations (오염농도 분포 해석을 통한 공동주택의 자연환기성능 향상을 위한 평면계획)

  • Kim, Jiyoeng;Lee, Seung-Hee;Kim, Taeyeon
    • KIEAE Journal
    • /
    • v.5 no.3
    • /
    • pp.41-48
    • /
    • 2005
  • Before occupation of an apartment housing, the builders are required to inform the test result of IAQ to the public. However, there is no simplified method to predict IAQ before measurement of pollutant concentration. In this study, a simplified way of predicting IAQ based on the distribution of indoor pollutant concentration is proposed. 7 different cases of air change rate have been simulated through CFD analysis to get the distribution ratio of each pollutant material and then simplified functions were used with CRIAQ1 values derived from CFD simulation to evaluate by comparing the influence of each material in the indoor pollutant concentration. Again, a lot of efforts which can improve the indoor air quality have been performed. Materials used in indoor space are labeled with their pollutant emission level. Installation of ventilation system in residential buildings will be regulated by a building codes sooner or later. But it is important to understand the fact that layout of walls, location or size of openings will influence the indoor air flow and pollutant concentration. And location of emitting material influences to indoor air pollutants distribution. But until now there is few recognition and consideration of these factors. Therefore, in this paper the effects of these factors is proved and some kind of guideline is made for designers after a comparison of typical apartment floor plan and a new type plan with their average pollutant concentration and its distribution of each room. CFD(Computational Fluid Dynamics) program was used to show the indoor air flow and pollutant concentration distribution. For this purpose, a typical $100m^2$ apartment floor plan was chosen as a case study model and several alternatives were reviewed to improve the IAQ performance. The simulation took place in the condition of natural ventilation through windows.

Analysis of High Concentration Diffusion Pattern by Air Pollutions in Port Industry Interfaces

  • Je-Ho Hwang;Sang-Hyung Park;So-Hyun Yun;Si-Hyun Kim
    • Journal of Korea Trade
    • /
    • v.26 no.3
    • /
    • pp.117-136
    • /
    • 2022
  • Purpose - Port is vital for international trade accounting for approximately 80% of world cargo transportation in the global trade sector. Air pollutants emitted owing to the related industry interfaces developed around the port spread throughout the dense population region can have harmful effects on the nearby residents. This study aims to analyze high-concentration diffusion pattern by air pollutants, considering the main management periods by air pollutants. Design/methodology - Employing the concentration criteria per main air pollutant, the analyses of concentration change patterns per air pollutant, wind characteristics that directly affected the air pollutant diffusion, distribution types per air pollutant, and high-concentration diffusion patterns by season according to time changes were conducted. Findings - The substances that caused harmful levels of air pollution in the hinterland living zone of the Busan New Port were PM_10, PM_2.5, and NO_2. Furthermore, the intensive management periods were as follows: For PM_10, 24-h (spring), 12:00-16:00 (summer), 12:00-16:00 (summer), 20:00-12:00 (fall), and 24:00-20:00 (winter), and for PM_2.5, 24-h (all four seasons), and for NO_2, 23:00-04:00 (spring), 23:00-08:00 (summer), and 20:00-08:00 (fall), and 23:00-04:00 (winter). Originality/value - Research finding indicates that regular monitoring and countermeasures to reduce air pollution for each air pollutant makes it possible to achieve effective air quality control in the port and hinterland living zones.

The Ivestigation and Estimate of Influence on Air Quality by the Exhaust of Air Pollutant from Facility of the District Heating Located in Small City (중소도시에 위치한 집단 열 공급시설에서 배출되는 대기오염물에 의한 주변 대기질의 영향 조사 및 예측)

  • Yeon, Ik-Jun;Kim, Kwang-Yul
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.3 s.49
    • /
    • pp.1-10
    • /
    • 2003
  • This study was aimed to investigate the influence on the vicinity by air pollutant generated from facility of the district heating located in local small town. We selected the seven areas arround the surroundings of facility of the district heating, compared the air quality evaluated before and after operations of the facility, and estimated the diffusion of air pollutant exhausted from the facility using a ISC model. The result was that the concentration of TSP before and after operations of the facility was 89${\sim}$94${\mu}$g/m$^3$,and 72${\sim}$81${\mu}$g/m$^3$, respectively and the latter showed a decline in concentration. Also, there was no relationship between straight distance from the facility of the district heating and the concentration of TSP. This result was applicable to cases of PM-10 and SO$_2$. We also investigated the influence on the air around the neighbored area by air pollutant produced from facility of the district heating using ISCLT3 model. The adding-concentrations of TSP, SO$_2$,NO$_2$, and CO were 0.0019${\sim}$0.00183${\mu}$g/m$^3$, 0.0029${\sim}$0.5648ppb, 0.2924${\sim}$l.9837ppb,and 0.0087${\sim}$0.0590ppb, respectively. It is predicted that each concentration is added to pollutant exhausted from facility of the district heating and is about 1/100${\sim}$1/180,000 of present air quality. This has a tiny influence on general air quality. According to this analysis, the concentration of air pollutant is less effected to pollutants expected by the facility of the district heating than other pollutants emitted from mobil source or industrial complex, and etc.

The Effects to Indoor Air Quality as Ventilation System Operation in Apartment House Using CFD Simulation (공동주택에서 환기장치류 가동특성에 따른 실내공기질 변화특성에 관한 연구)

  • Kim, Seok-Keun;Yee, Jurng-Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.2
    • /
    • pp.142-148
    • /
    • 2007
  • The purpose of this study is to suggest the effective ventilation strategies and control methods that can minimize energy cost maintaining acceptable IAQ level in apartment house. The effects of the air-cleaning and heat-recovery ventilation system on IAQ under various operating conditions are investigated based on the experimental and CFD analyzed results. The results can be summarized as follows. (1) When a ventilator is not operated, the concentration of several pollutants may highly show in the house even though environment-friendly building materials are applied. Therefore, a mechanical ventilation system is required to obtain proper ventilation. (2) The pollutant concentration is noticeably deceased under air-cleaning/ventilation mode of air-clinic system, however, pollutant of kitchen is stagnant, because fresh air is not carried into the kitchen. (3) When air-clinic system is only equipped at master bedroom and living room, the system does not effectively deliver fresh air throughout the whole house, and then high pollutant concentration is obtained in each room. In contrast the average pollutant concentration meets the guideline when air-clinic system is installed at each room. (4) The air-cleaning/ventilation mode significantly affects on room ventilation in comparison with ventilation mode only.

Evaluation of the Representativeness of Air Quality Monitoring Network in Seoul through Actual Measurement (대기오염도 실측에 의한 대기오염 자동측정망의 대표성 평가)

  • Jeon, Eui-Chan
    • Journal of Environmental Impact Assessment
    • /
    • v.5 no.1
    • /
    • pp.79-85
    • /
    • 1996
  • Simultaneous monitoring in many locations is necessary to evaluate the air quality and analyze future trend of a city, For this purpose, it is essential to install air pollution monitoring network. The first automatic air pollution monitoring network was introduced Seoul in 1973. As of 1995, 20 monitoring stations are now in operation. Concerning the management of the air pollution monitoring network, there was some argument among the relavant scholars, non-governmental organization(NGO) and the government organization. So far, there was no extensive evaluation and analysis about the network. The purpose of this study was to evaluate the representativeness of air quality monitoring network through actual measurement of the concentration of the air pollutant. The concentration of NOx was extensively measured widely in Seoul area three times using the TEA simple measuring technique. Even the judgement level for the area representativeness was lowered to 80%, Ssangmun-dong monitoring station tend to overestimate the pollutant concentration of the covered area. While, Sinlimdong monitoring station tend to underestimate the pollutant concentration of the covered area.

  • PDF

The Impact of Bake-Out Method on the Reduction of Pollutant Concentration in New Apartments (Bake-Out에 의한 신축 아파트의 실내 오염물질농도 저감효과 평가)

  • Pang Seung-Ki;Park Byung-Yoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.4
    • /
    • pp.335-343
    • /
    • 2006
  • Indoor air pollution has been significantly aggravated due to hazardous pollutants emitted from petrochemical finishing materials in new apartments. Pollutants emitted into indoor environment have significant effects on the health of occupants, causing undesirable symptoms related to sick building syndrome such as headache, dizziness, difficulty in concentration, etc. Therefore, this paper attempted to investigate the reduction effect of bake out on VOCs emission in new apartments. Experiments were carried out in three households, one of which was naturally ventilated. The naturally ventilated showed the lowest indoor pollutant concentration and also showed the highest reduction rate by the use of bake out. The most desirable result was observed when the household was naturally ventilated after bake out. More detailed experiments are expected to be carried out afterwards on the prediction of reduction rate of each pollutant.

The Impact of Ventilation Strategies on Indoor Air Pollution: A Comparative Study of HVAC Systems Using a Numerical Model (실내오염물질의 환기기술전략에 따른 영향평가 : 수치적 모델을 이용한 HVAC 시스템의 비교연구)

  • Park, Sung-Woo;Song, Dong-Woong;D.J. Moschandreas
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.E
    • /
    • pp.45-54
    • /
    • 1995
  • Indoor air quality models are useful to predict indoor air pollutant concentrations as a function of several indoor factors. Indoor air quality model was developed to evaluate the pollutant removal efficiency of variable-air-volume/bypass filtration system (VAV/BPFS) compared with the conventional variable-air-volume (VAV) system. This model provides relative pollutant removal effectiveness of VAV/BPFS by concentration ratio between the conventional VAV system and VAV/BPFS. The predictions agree closely, from 5 to 10 percent, with the measured values for each energy load. As a results, we recommend the VAV/BPFS is a promising alternative to conventional VAV system because it is capable of reducing indoor air pollutant concentration and maintaining good indoor air quality.

  • PDF

Simulation of Atmospheric Pollutants Concentration in the Urban Scale (도시 규모의 대기오염 농도 예측)

  • 이상득;정일현
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.2
    • /
    • pp.137-145
    • /
    • 1997
  • To predict the effects of air pollutant in the coastal region, we have developed the air pollutant model, the reaction model and the deposition of NO, $NO_2, and O_3$. And the numerical model of air pollutant concentration employed the nested technique to calculate with the higher resolution for the area. The nested technique used two grid systems, one for the large scale calculating region with the coarse mesh grid (CMG) and the other for the small scale region with the fine grid (FMG). In other to prove the validity of the simulation model the calculations were conducted for the present situation. The results of them reasonably agree with the observed data and proved the validity of the model.

  • PDF

A Numerical Simulation of Air Pollutant Concentration Considering Land and Sea Breeze in Ulsan Area (해륙풍을 고려한 울산지역 대기오염물질농도의 수치모의)

  • 이화운;원경미;정우식;오은주;김민선;도우곤
    • Journal of Environmental Science International
    • /
    • v.11 no.9
    • /
    • pp.933-943
    • /
    • 2002
  • The urban pollution if affected by local environmental, so it is necessary to consider area characteristics such as emission source and meteorological phenomena, in studying urban air pollution. Ulsan is laocated on south-east coast and has many industrial facilities, so many people have concerned about air pollution. This study contain conducting numerical simulation of air pollutant concentration considered land and sea breeze in Ulsan area with the numerical model.

Operating condition and air pollutant emission when do RPF co-combustion in coal fluid bed boiler (석탄유동층 보일러에 RPF 혼소시 운전조건 및 대기오염물질 배출 특성 변화)

  • Yoon, Kyoon-Duk;Park, In-Chul;park, Jong-Kyeong;Cho, Yeon-Haeng;Choi, Yeon-Seok;Shun, Do-Won;Park, Do-Hyun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.527-530
    • /
    • 2006
  • Because price of fossil fuel rises, necessity about alternative energy was risen. Studied co-combustion of RPF to coal fluid bed boiler by necessity of these althernative energy. Purpose of this study to coal fluid bed bioler RPF when did co-combustion, change operating condition and characteristic of air pollutant examine according to change of fuel characteristic, operating condition examined about combustion chamber temperature, oxygen content etc. and air pollutant examined about material that is included to allowable exhaust standard and dioxin. Co-combustion condition was 5%. It was no peculiar under test result operating condition. Concentration of Co and HCl rose according as do RPF co-combustion and the other pollutants had hardly changed. Dioxin is low concentration level more than $0.1ng-TEQ/Sm^3$. There was no pollutant that exceed akllowable exhaust standard for boiler but $SO_x,\;NO_x$ were exceeded about allowable exhaust standard for incinerating facility.

  • PDF