• Title/Summary/Keyword: air monitoring

Search Result 1,512, Processing Time 0.026 seconds

QA/QC Techniques for the Automated Hydrocarbon Monitoring Natwork in the UK

  • Rod Robinson;Tony andrews;David Butterfield;Paul Quincey
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.E1
    • /
    • pp.25-33
    • /
    • 2001
  • This paper presents an overview of the UK Hydrocarbon Monitoring Network and summarises some of the lessons learnt from running and automated VOC monitoring network in th UK. The paper will describe the operation of the network and the Quality Control and Quality Assurance (QA/QC) procedures used to ensure that the data qality objectives are met. The provision of accurate measurements of ambient air pollutant concentrations is a valuable and high-profile service of Governments, assisting policy decisions and allowing members of the public to be well-informed. The need for such measurements has been increased in the UK by the National Air Quality Strategy and European Air Quality Directives, with the National Networks playing a central role in delivering the information. The Hydrocarbon Network provides measurements directly in support of monitoring requirements for benzene and 1,3-butadiene, and of 23 other hydrocarbon species important for their role in ozone and secondary particulate formation.

An Integrated Air Monitoring Approach for Assessment of Formaldehyde in the Workplace

  • Dugheri, Stefano;Bonari, Alessandro;Pompilio, Ilenia;Colpo, Marco;Mucci, Nicola;Arcangeli, Giulio
    • Safety and Health at Work
    • /
    • v.9 no.4
    • /
    • pp.479-485
    • /
    • 2018
  • The aim of this study is to validate an integrated air monitoring approach for assessing airborne formaldehyde (FA) in the workplace. An active sampling by silica gel impregnated with 2,4-dinitrophenylhydrazine, a passive solid phase microextraction technique using O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine as on-fiber derivatization reagent, an electrochemical direct-reading monitor, and an enzyme-based badge were evaluated and tested over a range of 0.020-5.12 ppm, using dynamically generated FA air concentrations. Simple linear regression analysis showed the four methods were suitable for evaluating airborne FA. Personal and area samplings in 12 anatomy pathology departments showed that the international occupational exposure limits in the GESTIS database were frequently exceeded. This monitoring approach would allow a fast, easy-to-use, and economical evaluation of both current work practices and eventual changes made to reduce FA vapor concentrations.

On the Recent Air Pollution Levels Observed in the Regional Air Monitoring Network -High Air Pollution Concentration Episodes and Their Meteorological Characteristics in 2002 (지역 대기질 측정망에 나타난 국내 대기오염도의 최근 동향 -2002년 고농도 사례 및 그 기상 특징)

  • Kim C.-H;Park I.-S;Lee S.-J;Kim J.-S;Jin H.-A;Sung H.-G
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.2
    • /
    • pp.215-224
    • /
    • 2004
  • We report the high concentration episodes for PM$_{10}$, SO$_2$, NO$_2$, and $O_3$ in many urban areas Korea during 2002. The high concentration episodes are identified based on the National Ambient Air Quality Standards and the observations obtained from the Regional Air Monitoring Network composed of approximately 160 air pollution monitoring stations located in a number of major or big cities in South Korea including Seoul, Pusan, Daegu, and Incheon cities. The results show that the twenty cases of high concentration episodes in 2002 consists of both ozone warning episodes (6 cases) and high PM$_{10}$ concentration cases (14 cases), and one half of the latter are found to occur in association with the Yellow Sand (Asian Dust) phenomena. The most outstanding characteristics of the reported episodes are the excessively high levels of maximum PM$_{10}$ concentrations during the Yellow Sand period (i.e., exceeding 3,000$\mu\textrm{g}$/㎥ in April, 2002) and their variable occurrence frequencies across seasons. The high ozone concentration episode days are mainly resulting from both the high photochemical reactions and poor ventilations. The high PM$_{10}$ concentration days during non Yellow Sand periods, however, mostly occurred under the influence of synoptic meteorological conditions such as stagnant or slowly passing high pressure centers, and consequently prevailing weak wind speeds over the Korean peninsula. The overall results of our study thus suggest the importance of both synoptic and local meteorological factors for high concentration levels in the major and/or big cities in Korea.n Korea.

A Study on Environmental Micro-Dust Level Detection and Remote Monitoring of Outdoor Facilities

  • Kim, Seung Kyun;Mariappan, Vinayagam;Cha, Jae Sang
    • International journal of advanced smart convergence
    • /
    • v.9 no.1
    • /
    • pp.63-69
    • /
    • 2020
  • The rapid development in modern industrialization pollutant the water and atmospheric air across the globe that have a major impact on the human and livings health. In worldwide, every country government increasing the importance to improve the outdoor air pollution monitoring and control to provide quality of life and prevent the citizens and livings life from hazard disease. We proposed the environmental dust level detection method for outdoor facilities using sensor fusion technology to measure precise micro-dust level and monitor in realtime. In this proposed approach use the camera sensor and commercial dust level sensor data to predict the micro-dust level with data fusion method. The camera sensor based dust level detection uses the optical flow based machine learning method to detect the dust level and then fused with commercial dust level sensor data to predict the precise micro-dust level of the outdoor facilities and send the dust level informations to the outdoor air pollution monitoring system. The proposed method implemented on raspberry pi based open-source hardware with Internet-of-Things (IoT) framework and evaluated the performance of the system in realtime. The experimental results confirm that the proposed micro-dust level detection is precise and reliable in sensing the air dust and pollution, which helps to indicate the change in the air pollution more precisely than the commercial sensor based method in some extent.

Calculation Method for the Concentration of Persistent Organic Pollutants (POPs) Collected by Passive Air Samplers (수동대기채취기를 이용한 잔류성유기오염물질의 농도산정)

  • Choi, Sung-Deuk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.2
    • /
    • pp.217-227
    • /
    • 2013
  • Passive air samplers (PAS) have been developed since the early 2000s and widely used for the atmospheric monitoring of persistent organic pollutants (POPs). PAS are useful especially for the investigation of source-receptor relationship of POPs because they provide higher spatial resolution data. In Korea, however, only a few research groups have conducted POPs monitoring using PAS. One of the reasons for the limited application of PAS might be due to a complicated calculation method for air concentration. In this study, therefore, we introduced the principle of polyurethane foam (PUF)-PAS, which has been most widely used in the world, and provided an example of the calculation of air concentration of polycyclic aromatic hydrocarbons (PAHs). As all data tables and equations for this calculation were provided, this method can be used for the conversion of the amount of POPs (ng) in a PUF disk to air concentration ($ng/m^3$).

Chemical Characteristics of Ambient Aerosol during Asian Dusts and High PM Episodes at Seoul Intensive Monitoring Site in 2009 (2009년 서울지역 황사 및 고농도 미세먼지 사례 시 미세먼지의 화학성분 특성)

  • Park, Seung-Myung;Moon, Kwang-Joo;Park, Jong-Sung;Kim, Hyun-Jae;Ahn, Jun-Yong;Kim, Jeong-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.3
    • /
    • pp.282-293
    • /
    • 2012
  • This study aimed to show the chemical characteristics of $PM_{10}$ and $PM_{2.5}$ during Asian dust (AD) events and high PM episodes observed in Seoul. Time-resolved chemical composition of $PM_{10}$ or $PM_{2.5}$ was monitored in 1 hour interval using ambient ion monitor, semi-continuous carbon monitor, and on-line XRF spectrometer at Seoul intensive monitoring site in 2009. Considering that AD events were classified into three different cases according to the source area and pathway, the concentrations of ammonium-sulfate and trace metal components were relatively high when the AD were occurred in Gobi and inner-mongolia and transported across the Bohai bay. In addition, the influence of alkaline dust, which carried from saline land located in the northeastern China, was observed when the AD was originated from Gobi, inner-mongolia, and Manchuria. Except AD events, the high PM episodes observed in Seoul were impacted by various anthropogenic sources such as biomass burning, motor vehicle, oil combustion and road dust.

Design of Unconstrained Baby Monitoring System Based on a Doppler Radar and an Air Mattress (도플러 레이더와 에어 매트리스를 이용한 무구속 방식의 신생아 감시 장치 설계)

  • Yang, Seong-Soo;Cho, Sung-Pil;Park, Ho-Dong;Lee, Kyoung-Joung
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.6
    • /
    • pp.177-184
    • /
    • 2014
  • Continuous monitoring of heart rates and respiratory rates for newborns or infants is very important since the abnormal breathing and heart problems can threaten the life of newborns or infants. A noncontact baby monitoring system based on a Doppler radar and an air mattress was designed. The Doppler radar was used to acquire respiratory signals and the air mattress was employed to obtain heart rates. The performance of the designed system was evaluated using a commercialized infant simulator ($Simbaby^{TM}$) and a respiration belt transducer was used to measure respiration rates as a reference. Results for respiratory rates revealed that the correlation coefficients between I-and Q-channel and the respiration belt were 0.84 and 0.91 and the mean ${\pm}$ standard deviations of errors between them were $1.66{\pm}1.92$ (bpm) and $0.88{\pm}1.65$ (bpm). Heart rates showed that the correlation coefficient between air mattress and set value of the simulator was 0.73 and the mean ${\pm}$ standard deviation of errors between them was $1.09{\pm}3.45$ (bpm). These results indicate that the designed system holds the potential as an effective monitoring tool for continuous monitoring heart rates and respiratory rates of newborns or infants.

Application of MODIS Satellite Observation Data for Air Quality Forecast (MODIS 인공위성 관측 자료를 이용한 대기질 예측 응용)

  • Lee, Kwon-Ho;Lee, Dong-Ha;Kim, Young-Joon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.6
    • /
    • pp.851-862
    • /
    • 2006
  • Satellites have been valuable tool for global/regional scale atmospheric environment monitoring as well as emission source detection. In this study, we present the results of application of satellite remote sensing data for air quality forecast in Seoul metropolitan area. AOT (Aerosol Optical Thickness) data from TERRA/MODIS (Moderate Resolution Imaging Spectre-radiometer) satellite were compared to ground based $PM_{10}$ mass concentrations, and used to estimate the possibility of the aerosol forecasting in Seoul metropolitan area. Although correlation coefficient (${\sim}0.37$) between MODIS AOT products and surface $PM_{10}$ concentration data was relatively low, there was good correlation between MODIS AOT and surface PM concentration under certain atmospheric conditions, which supports the feasibility of using the high-resolution MODIS AOT for air quality forecasting. The MODIS AOT data with trajectory forecasts also can provide information on aerosol concentration trend. The success rate of the 24 hour aerosol concentration trend forecast result was about 75% in this study. Finally, application of satellite remote sensing data with ground-based air quality observations could provide promising results for air quality monitoring and more exact trend forecast methodology by high resolution satellite data and verification with long term measurement dataset.

Establishment of Safety Alert Systems for Urban Air Mobility Operations (도심항공교통(UAM) 운항을 위한 안전 경고 기능 구축)

  • Sang-il Choi;Seung-yeon Nam;Hui-yang Kim
    • Journal of Advanced Navigation Technology
    • /
    • v.28 no.2
    • /
    • pp.163-171
    • /
    • 2024
  • In the existing air traffic management (ATM) system, various types of safety alert features are provided based on trajectory data to ensure the safety of aircraft operations, along with aircraft position and detailed flight information. The urban air traffic management (UATM) system for urban air mobility (UAM) should also provide safety alert features to ensure the safety of UAM operations. Considering the operational environment of UAM, it is necessary that the safety alert features provided at least match or exceed those available in the existing ATM system. This study aims to present the safety alert features of the new UATM system that differ from those provided by the existing ATM system before introduction and commercialization of UAM. The study was conducted focusing on the safety alert features that should be provided in the event of a deviation from the UAM's path, and the establishment of the safety alert features was carried out in two parts: approach path monitor (APM), which is applied during the approach phase, and route adherence monitoring (RAM), which is applied during the cruise phase.

Wireless Sensors Module for Remote Room Environment Monitoring

  • Lee, Dae-Seok;Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.449-452
    • /
    • 2005
  • For home networking system with a function of air quality monitoring, a wireless sensor module with several air quality monitoring sensors was developed for indoor environment monitoring system in home networking. The module has various enlargements for various kinds of sensors such as humidity sensor, temperature sensor, CO2 sensor, flying dust sensor, and etc. The developed wireless module is very convenient to be installed on the wall of a room or office, and the sensors in the module can be easily replaced due to well designed module structure and RF connection method. To reduce the system cost, only one RF transmission block was used for sensors' signal transmission to 8051 microcontroller board in time sharing method. In this home networking system, various indoor environmental parameters could be monitored in real time from RF wireless sensor module. Indoor vision was transferred to client PC or PDA from surveillance camera installed indoor or desired site. Web server using Oracle DB was used for saving the visions by web-camera and various data from wireless sensor module.

  • PDF