Development of On-Line Monitoring System for Pumped Storage Generator/Motor (양수발전소 발전-전동기 운전중 감시 시스템의 개발)

  • 김희동;주영호
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.3
    • /
    • pp.168-174
    • /
    • 2004
  • On-line monitoring system(OMS) has been developed for the pumped storage generator/motor The OMS is applied to diagnosis of the PD(partial discharge) activity of stator insulation, the shorted-turn of rotor winding and the variation of the air-gap between stator and rotor. The OMS consists of DAS(data acquisition system), main server system, gateway and display PC. The DAS measures the PD, the shorted-turn and air-gap from three sensors installed on the generator/motor. The gateway controls the data which sent by DAS. The main server system saves the data, analyzes the data and conducts the diagnostic algorithm. The display PC shows the diagnostic results of partial discharge, shorted-turn and air-gap. Field tests were conducted using PDA(partial discharge analyzer). The results of the OMS and PDA measurements can be directly correlated with normalized quantity number(NQN), PD magnitude(Qm) and PD pattern.

Current Status and Prospects of Standard Methods for the Measurements of Air Pollution in Korea (대기오염공정시험법의 체계구축과 개선방향)

  • Kim, Ki-Hyun;Bae, Min-Suk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.4
    • /
    • pp.439-446
    • /
    • 2013
  • In this research, the present standard analytical methods for the monitoring of air pollution levels established by the Korean Ministry of Environment (KMOE) were examined in reference to the recent outputs of several research projects conducted for their amendments. The evaluation of the two criterion methods between the main (the present guideline) and reference methods (the proposed alternate guideline) was made in terms of authenticity and reliability of the quality assurance (QA) and of compatibility of methods. The results of this comparative evaluation are presented for the analysis of both ambient air and source samples. Based on this analysis, we propose a new direction for the future amendment.

A Development of Remote Supervisory Controlling System of Air Compressor (공기 압축기의 원격 감시제어시스템 개발)

  • 최승현;강대규;이성근;김윤식;박영산
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1999.11a
    • /
    • pp.482-485
    • /
    • 1999
  • This paper proposes a remote supervisory controlling system of air compressor that is controlled by 80196KC microprocessor. In proposed monitoring system, air compressor located in long distance can be controlled In any condition by RS-232 serial communication. Change of data and abnormal signal of it can be also obtained. The validity of the proposed monitoring system is verified through digital simulations and experiments for air compressor driven by induction motor.

  • PDF

Study of Air Quality Monitoring based on Wireless Sensor Network (무선센서네트워크에 기반한 공기질 모니터링 연구)

  • Park, Duck-Shin;Cho, Young-Min;Kwon, Soon-Bark;Park, Eun-Young;Ok, Min-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1756-1760
    • /
    • 2008
  • In this study, it was suggested how to monitor the air quality with use of intelligent wireless sensor network in the subway station. When Zigbee-based ubiquitous sensor network was used, smaller budget was required in configuring the system compared to existing air-quality monitoring method and this system may easily be configured due to easy installation of communication cables. The study will be continued to supplement the network systems currently installed in subway stations and the completion of development of this system is expected to make a large contribution in improvement of indoor air quality.

  • PDF

Separation Performance of Zigzag Air Classifier

  • Hirajima, Tsuyoshi;Nishida, Takuji;Toshima, Ryutaro;Kataoka, Kenji;Tsunekawa, Masami;Asakura, Kuniomi
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.759-764
    • /
    • 2001
  • The separation performance of zigzag air classifier with angle of 90 degrees was studied using narrow size fractions of thin square samples and granular samples. The simulation results of air velocity inside the classifier indicated that the zigzag geometry induces a new pattern consisting of an upward flow and a circulation flow, Experimental results showed that overflow product recovery was described as an integral calculus of normal distribution as a function of dimensionless air velocity ( $V_{A}$ $V_{A50}$), where $V_{A}$ is superficial air velocity and $V_{A50}$ is the $V_{A}$ at the fifty percent recovery. The $V_{A}$ values were predicted using the equations derived from dynamics for a particle dropping in air. A monitoring system that utilizes changes in acoustic signals emitted during the process of air classification was developed to separate PET with desired recovery or grade. The technical feasibility of the on-line monitoring of the PET recovery and grade was demonstrated by measuring relative energy of the signals.signals.als.